Miniature High Capacity Relays with SPST-NO 0A and SPST-NO + SPST-NC A SPST-NO 0A and SPST-NO + SPST-NC A for power switching and output that satisfy the needs for space-saving. Small High-capacity Relays Compact: 0 0 mm (L W H). Low power consumption: mw. Ultrasonically cleanable models is available. Exclusive P model for sockets is now available. RoHS Compliant Number Legend -@-@@@@@-@-@-@-@ 6 7 9. Relay Function None: Single-side stable U : Single-winding latching K : Double-winding latching. Contact Form : SPST-NO (a) : SPST-NO (a) + SPST-NC (b). Contact Type : Single. Enclosure rating : Fully sealed 7: Flux protection. Terminal Shape P: PCB terminals Socket mounting Terminals C: Self-clinching PCB 6. Contact Material None: Standard (Ag-alloy (Cd free)) FD : AgSnIn Contacts (Suitable for DC inductive load with high inrush current) 7. Approved Standards US: UL/CSA. Washability None: Standard model (not compatible with ultrasonically cleanable models) U : For ultrasonically cleanable 9. Mounting None: Mounted directly to PCB P : Mounted to Socket Application Examples Ideal for output applications of control equipments
Ordering Information Standard s (UL, CSA certified) Relay Function Single-side stable Single-winding latching Double-winding latching Minimun Enclosure Rated coil Rated coil Rated coil packing rating Contact form Terminals unit Flux protection SPST-NO (a) SPST-NO (a) + SPST-NC (b) Straight PCB Self-clinching PCB Straight PCB Self-clinching PCB -7P-US -7P-FD-US -7C-US -7P-US -7P-FD-US -7C-US 6 VDC U-7P-US K-7P-US 6 VDC VDC VDC VDC VDC VDC VDC VDC U-7P-FD-US VDC K-7P-FD-US VDC VDC VDC K-7C-US VDC VDC VDC VDC 6 VDC U-7P-US 6 VDC K-7P-US 6 VDC VDC VDC VDC VDC VDC VDC VDC U-7P-FD-US VDC K-7P-FD-US VDC VDC VDC 6 VDC U-7C-US K-7C-US VDC VDC VDC VDC VDC 00 pcs/ tray Relay Function Single-side stable Single-winding latching Double-winding latching Minimun Enclosure Rated coil Rated coil Rated coil packing rating Contact form Terminals unit Fully sealed SPST-NO (a) SPST-NO (a) + SPST-NC (b) Straight PCB Self-clinching PCB Straight PCB Self-clinching PCB -P-US -P-FD-US -C-US -P-US -P-FD-US -C-US 6 VDC U-P-US 6 VDC K-P-US 6 VDC VDC VDC VDC VDC VDC VDC VDC U-P-FD-US VDC K-P-FD-US VDC VDC VDC VDC U-C-US K-C-US VDC VDC VDC VDC VDC 6 VDC U-P-US 6 VDC K-P-US 6 VDC VDC VDC VDC VDC VDC VDC VDC U-P-FD-US VDC K-P-FD-US VDC VDC VDC 6 VDC U-C-US K-C-US 6 VDC VDC VDC VDC VDC Note. When ordering, add the rated coil to the model number. Example: -7P-US DC Rated coil However, the notation of the coil on the product case as well as on the packing will be marked as @@ VDC. 00 pcs/ tray
Ultrasonically Cleanable s (UL, CSA certified) Relay Function Single-side stable Single-winding latching Double-winding latching Minimun Enclosure Rated coil Rated coil Rated coil packing rating Contact form Terminals unit Fully sealed SPST-NO (a) SPST-NO (a) + SPST-NC (b) Straight PCB Self-clinching PCB Straight PCB Self-clinching PCB -P-US-U -C-US-U -P-US-U -C-US-U 6 VDC U-P-US-U K-P-US-U VDC VDC VDC VDC VDC VDC VDC VDC K-P-US-U VDC VDC VDC VDC Note. When ordering, add the rated coil to the model number. Example: -P-US-U DC Rated coil However, the notation of the coil on the product case as well as on the packing will be marked as @@ VDC. 00 pcs/ tray Connecting Sockets (Sold Separately) Applicable relays Minimun packing unit -P-US-P -7P-US-P -P-US-P -7P-US-P U-P-US-P P-06P U-7P-US-P U-P-US-P U-7P-US-P 0 pcs/tube K-P-US-P K-7P-US-P K-P-US-P K-7P-US-P Removal Tool Hold-down Clips P-0P P6B-Y P6B-C Note. Use the -@@@@P-US-P to mount to a P Socket.. When using by combining sockets, the rated current will be A due to its rated switching current.
Ratings Coil: -Pole, Single-side Stable Type (Including models for ultrasonically cleanable) Coil: Single-winding Latching Type (Including models for ultrasonically cleanable) Coil: Double-winding Latching Type (Including models for ultrasonically cleanable) Note. The rated current and coil resistance are measured at a coil temperature of C with a tolerance of ±0%..The operating characteristics are measured at a coil temperature of C..The Max. is the maximum that can be applied to the relay coil. Contact Item Rated current (ma) Coil resistance (Ω) Rated 67 0 6 VDC. 0 VDC 6.7 70 VDC.,0 Item Rated current (ma) Coil resistance (Ω) Rated 67 0 6 VDC. 0 VDC 6.7 70 VDC.,0 Must operate Must release % of rated 70% max. 0% min. Must set Must reset % of rated 70% max. 70% max. Max. 60% (at C) Max. 60% (at C) Power consumption (mw) Approx. Power consumption Set coil (mw) Reset coil (mw) Item Rated current (ma) Coil resistance (Ω) Must set Set coil Reset coil Set coil Reset coil Rated 9 9.. 6.0 6.0 9. 9. 6 VDC 6.7 6.7 9 9 VDC.. VDC.7.7,06,06 Contact Form Rated load Resistive load SPST-NO (a) Inductive load (cosφ = 0.; L/R = 7 ms) Must reset % of rated 70% max. 70% max. Resistive load Max. 0% (at C) Power consumption Set coil (mw) SPST-NO (a) + SPST-NC (b) Reset coil (mw) 0 0 Inductive load (cosφ = 0.; L/R = 7 ms) 0 A ( A) at 0 VAC A ( A) at 0 VAC A ( A) at 0 VAC A ( A) at 0 VAC Item 0 A (0 A) at 0 VDC A ( A) at 0 VDC A ( A) at 0 VDC A ( A) at 0 VDC Contact type Single Contact material Ag-Alloy (Cd free) Rated carry current 0 A (0 A) A ( A) Max. switching 0 VAC, Max. switching current 0 A (0 A) A ( A) Note. The values shown in parentheses ( ) are for -FD models only.
Characteristics (Including models for ultrasonically cleanable) Item Classification Single-side Stable Single-winding Latching Double-winding Latching Contact resistance * 0 mω max. Operate (set) time 0 ms max. Release (reset) time 0 ms max. Min. set pulse width 0 ms (at C) Min. reset pulse width 0 ms (at C) Between coil and contacts,000 MΩ min. Between contacts of the Insulation same polarity,000 MΩ min. resistance * Between contacts of different polarity,000 MΩ min. (SPST-NO, SPST-NC) Between set and reset coils,000 MΩ min. Between coil and contacts,000 VAC 0/60Hz for min Between contacts of the Dielectric same polarity,000 VAC 0/60Hz for min strength Between contacts of different polarity,000 VAC 0/60Hz for min (SPST-NO, SPST-NC) Between set and reset 0 VAC 0/60Hz for coils min Vibration Destruction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) resistance Malfunction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) Shock Destruction,000 m/s resistance Malfunction 00 m/s Durability Mechanical 0,000,000 operations min. (at,000 operations/hr) Electrical 00,000 operation min. (at,00 operations/hr under rated load) Failure rate (P level) (reference value) * 0 ma at Ambient operating temperature - C to 70 C (with no icing or condensation) Ambient operating humidity % to % Weight Approx..6 g Note. The given values are initial values. *. Measurement conditions:, A, drop method. *. Testing conditions: measured with a 00 VDC megohmmeter (at 0 VDC between set/reset coil). *. This value was measured at a switching frequency of 0 operations/min. Engineering Data Maximum Switching Capacity -@-US -7@-US Switching current (A) 0 0 0 7 0.7 0. 0. DC resistive load DC inductive load AC resistive load AC inductive load (cosφ = 0.) -@-FD-US -7@-FD-US Switching current (A) 0 0 0 0.7 0. 0. DC resistive load DC inductive load AC resistive load AC inductive load (cosφ = 0.) 0. 7 0 0 0 00 0 0,000 Switching 0. 7 0 0 0 00 0 0,000 Switching -@-US -7@-US -@-FD-US -7@-FD-US Switching current (A) 0 0 0 AC resistive load Switching current (A) 0 0 0 AC resistive load 0.7 DC resistive load DC inductive load AC inductive load (cosφ = 0.) 0.7 DC resistive load DC inductive load AC inductive load (cosφ = 0.) 0. 0. 0. 0. 0. 7 0 0 0 00 0 0,000 Switching 0. 7 0 0 0 00 0 0,000 Switching
Durability -@-US, -@-US -7@-US, -7@-US Durability ( 0 operations) 00 00 00 0 0 0 -@-US -7@-US 0 VAC inductive (cosφ = 0.) 0 VDC inductive -@-US -7@-US 0 VAC resistive 0 VDC resistive -@-US -7@-US 0 VAC inductive (cosφ = 0.) 0 VDC inductive -@-US -7@-US 0 VAC resistive 0 VDC resistive 0 6 7 9 0 -@-FD-US, -@-FD-US -7@-FD-US, -7@-FD-US Durability (x 0 operations) 00 00 00 0 0 0 -@-FD-US -7@-FD-US 0 VAC resistive 0 VDC resistive -@-FD-US -7@-FD-US 0 VAC resistive -@ -FD-US -7@ -FD-US 0 VDC resistive -@-FD-US -@-FD-US -7@-FD-US -7@-FD-US 0 VAC inductive 0 VAC inductive (cosφ = 0.) (cosφ = 0.) 0 VDC inductive 0 VDC inductive 0 6 7 9 0 Ambient Temperature vs. Maximum Coil Voltage Maximum coil (%) 0 60 0 0 0 00 0 Switching current (A) Switching current (A) Ambient Temperature vs Must Operate and Must Release s Must Operate and Must Release s (%) 00 0 60 0 0 Sample: -P-US Number of Relays: pcs Must operate Must release max. X min. max. X min. 60 0 0 0 0 0 60 70 0 90 Ambient temperature ( C) Note. The maximum coil refers to the maximum value in a varying range of operating power, not a continuous. Shock Malfunction Energized (a contact) X Z' Y Y' Z Unit: m/s 00 X' Sample: -P-US DCV Number of Relays: 6 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with without energizing the Relays to check the number of malfunctions. Requirement: 00 m/s De-energized (b contact) X Z' 0-0 -0 0 0 0 60 0 Y Y' Unit: m/s Z X' Y Y' Ambient temperature ( C) Shock direction X X' (coil) Z Z' Magnetic Interference (between Relays) Change rate on the basis of rated value (OV) (%) 0 - - - Initial l=a l=.0a l l=.0a l=a l max. X min. Sample (Mounting pitch) l=a l=0.6a 6
Dimensions Flux Protection (Straight PCB) -@7P (-FD) -US Flux Protection (Self-clinching PCB) -@7C-US 0.6<0.7> (9.9)* <.0> <.0> max. (.9)* <0.> 0.6. 0.6 Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P). (9.9)* max. (.9)* 0. 0 max. (9.9)* 0 max. 0. (9.9)* PCB Mounting Holes Tolerance: ±0. -pole 0.6 (.) Four,.-dia. holes Six,.-dia. holes Terminal Arrangement/ Internal Connections -pole +. 0.6 0.6 (0.)*. 0.6 (.0)* 0.6 (.) + 6 Note: Check carefully the coil polarity of the Relay. Fully Sealed (Straight PCB) -@P (-FD) -US Fully Sealed (Self-clinching PCB) -@C-US 0.6<0.7> (9.9)* <.0> (9.9)* <.0> 0.6. max. (.9)* <0.> 0.6 Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P). max. (.9)* 0 max. 0. (9.9)* 0 max. 0. (9.9)* PCB Mounting Holes Terminal Arrangement/ -pole Internal Connections Tolerance: ±0. Four,.-dia. holes -pole 0.6 (.) Six,.-dia. holes +. 0.6 0.6 (0.)*. 0.6 (.0)* 0.6 (.) + 6 Note: Check carefully the coil polarity of the Relay. Note: Orientation marks are indicated as follows: 7
Flux Protective Single-winding Latching (Straight PCB) U-@7P (-FD) -US 0.6<0.7> Flux Protective Single-winding Latching (Self-clinching PCB) U-@7C-US (9.9)* <.0> (9.9)* <.0> 0.6. max. (.9)* <0.> 0.6 Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P). max. (.9)* 0. 0. 0 max. (9.9)* 0max. (9.9)* -pole PCB Mounting Holes Tolerance: ±0. 0.6 (.) Four,.-dia. holes -pole Six,.-dia. holes Terminal Arrangement/ Internal Connections + SR + S: Set coil R: Reset coil SR +. 0.6 0.6 (0.)*. 0.6 (.0)* 0.6 (.) + 6 Note: Check carefully the coil polarity of the Relay. Fully Sealed Single Latching s (Straight PCB) U-@P (-FD) -US 0.6<0.7> (9.9)* <.0> <.0> max. (.9)* <0.> 0.6. 0.6 Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P). 0 max. 0. (9.9)* -pole PCB Mounting Holes Tolerance: ±0. 0.6 (.) Four,.-dia. holes Terminal Arrangement/ Internal Connections -pole + SR + S: Set coil R: Reset coil Fully Sealed Single Latching s (Self-clinching PCB) U-@C-US (9.9)* max. (.9)* 0 max. 0. (9.9)* Six,.-dia. holes + SR. 0.6 0.6 (0.)*. 0.6 (.0)* 0.6 (.) + 6 Note: Check carefully the coil polarity of the Relay. Note: Orientation marks are indicated as follows:
Flux Protective Double-winding Latching (Straight PCB) K-@7P (-FD) -US 0.6<0.7> 0 max. (9.9)* <.0> <.0> <.0> max. (.9)* <0.> 0.6. 0.6 Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P). 0 max. 0. (9.9)* PCB Mounting Holes Terminal Arrangement/ Internal Connections Tolerance: ±0. -pole Six,.-dia. holes -pole (.) S R + + 7 S: Set coil R: Reset coil Flux Protective Double-winding Latching (Self-clinching PCB) K-@7C-US (9.9)* max. (.9)* Eight,.-dia. holes. 0.6 0.6. (0.)* 0.6 (.0)* 0 max. 0. (9.9)* (.) S R + + 7 6 Note: Check carefully the coil polarity of the Relay. Fully Sealed Double-winding Latching (Straight PCB) K-@P (-FD) -US (9.9)* max. (.9)* PCB Mounting Holes Tolerance: ±0. Terminal Arrangement/ Internal Connections 0.6<0.7> Fully Sealed Double-winding Latching (Self-clinching PCB) K-@C-US <.0> <.0> <.0> <0.> 0.6. 0.6 Dimensions in pointed brackets < > are for the Relay mounted to Socket (-P). (9.9)* max. (.9)* 0 max. 0. (9.9)* 0 max. 0. (9.9)* -pole (.) Six,.-dia. holes Eight,.-dia. holes -pole S + + 7 S R S: Set coil R: Reset coil R. 0.6 0.6 (0.)*. 0.6 (.0)* (.) + + 7 6 Note: Check carefully the coil polarity of the Relay. Note: Orientation marks are indicated as follows: 9
Connecting Sockets Dimensions Socket for single-winding latching/single-side a table s P-06P.max. ()* PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0. mm max. (.9)*. Six,.-dia. holes 0.max. (0.6)* 7. 0.6 0. 0.6±0. 0. (.6) 0.6 Socket for double-winding latching s P-0P.max. ()* PCB Mounting Holes (BOTTOM VIEW) Tolerance: ±0. mm max. (.9)*. Eight,.-dia. holes 0.max. (0.6)* 7. 0. 0.6±0. 0. (.6) Note: Orientation marks are indicated as follows: 0
Removal Tool P6B-Y Hold-down Clips P6B-C Approved Standards The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. UL Recognized (File No. E6) CSA Certified (File No. LR9) Number of poles Coil ratings Contact ratings Number of test operations 0 A, 0 VAC (eneral use) 0 C 0 A, 0 VDC (Resistive) 0 C /6 HP VAC, / HP, VAC 0 C / HP 0 VAC, / HP, 0 VAC 0 C W, 0 VAC, (Tungsten) 0 C (excluding -FD s) 0 VA, 0 to 6 VAC Max A (Pilot Duty) 0 C. VA, 0 VDC (Pilot Duty) 0 C 6,000 6,000 ( ) to VDC LRA,. FLA, 0 VDC 0 C A, 0 VAC (eneral use) 0 C A, 0 VDC (Resistive) 0 C /6 HP VAC, / HP, VAC 0 C / HP 0 VAC, / HP, 0 VAC 0 C W, 0 VAC, (Tungsten) 0 C (excluding -FD s) 0 VA, 0 to 6 VAC Max A (Pilot Duty) 0 C. VA, 0 VDC (Pilot Duty) 0 C 0,000,000 (-FD s) 6,000 6,000 LRA,. FLA, 0 VDC 0 C 0,000,000 (-FD s) EN/IEC, VDE Certified (Certificate No. 9) ( ) Number of poles Coil ratings,, 6,, VDC Single-stable:,, 6,, VDC EN/IEC, TÜV Certified (Registration No. R09) ( ) Number of poles Coil ratings Single-stable:,, 6,, VDC Latching:,, 6,, VDC Contact ratings 0 A, 0 VAC (cosφ = ) 0 C A, 0 VAC (cosφ = 0.) 0 C 7 A, 0 VAC (cosφ = ) 0 C A, 0 VAC (cosφ = 0.) 0 C Contact ratings 0 A, 0 VAC (cosφ = ) 0 C A, 0 VAC (cosφ = 0.) 0 C 0 A, 0 VDC (L/R = 0 ms) 0 C A, 0 VAC (cosφ = ) 0 C A, 0 VAC (cosφ = 0.) 0 C A, 0 VDC (L/R = 0 ms) 0 C Approved switching operations 0,000 Approved switching operations 0,000
Precautions Please refer to PCB Relays Common Precautions for correct use. Correct Use Mounting Do not reverse the polarity of the coil (+, ). When mounting more than two relays side by side, keep the gap between Relays as shown below to ensure a good heat dissipation. It may result in malfunction if heat is not dissipated smoothly from the Relay. mm pitch min. between terminals mm pitch min. between terminals Sockets 7 mm max. for sockets 7. mm When mounting the Relay, make sure to insert the Relay terminals perpendicularly and correctly into the socket contact pin. Hold-down clips (for mounting and removal) are also available. The P model has a flux-resistant construction. Do not wash it down with water. The max. carry current of sockets is A. Not applicable to the self-clinching type. Double-winding Latching Circuit It is recommended to perform wiring of No. and No. of the negative (-) terminal as COM wiring, in order to improve the operation stability for Double-winding Latching. Using SPDT contact of the SPST-NO+SPST-NC Relay Do not construct a circuit so that overcurrent and burning occur if the NO, NC and SPDT contacts are shortcircuited with the SPST-NO+SPST-NC Relay. Arcing may generate shortcircuiting between contacts if there is short-circuiting because of conversion to the MBB contact caused by asynchronous operation of the NO and NC contacts, the interval between the NO and NC contacts is small, or a large current is left open. Other precautions This Relay is a Power Relay which is suitable for power load switching. Do not use the for signal purposes such as micro load switching under 0 ma. (+) + + 7 S R COM Please check each region's Terms & Conditions by region website. OMRON Corporation Electronic and Mechanical Components Company Regional Contact Americas https://www.components.omron.com/ Asia-Pacific https://ecb.omron.com.sg/ Korea https://www.omron-ecb.co.kr/ Europe http://components.omron.eu/ China https://www.ecb.omron.com.cn/ Japan https://www.omron.co.jp/ecb/ OMRON Corporation 7-0 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Cat. No. K0-E- 0(007)(O)