State of the Art Film Dosimetry

Similar documents
A Guide to Radiochromic Film Dosimetry with EBT2 and EBT3

GafChromic EBT2 and EBT3 Films for Ball Cube II Phantom

Using Radiochromic Film Tips and Techniques

- Water resistant. - Large size.

The most Comprehensive, Reliable, Economical and Easy to use GAFCHROMIC film based RT QA system Updated Feb 08 BUSINESS UNIT OF ISP

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

IV. 4. An Optical Common-mode Rejection for Improving the Sensitivity Limit of a Radiochromic Imaging Film

ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

GAFCHROMIC. Therapy Dosimetry Media Models to

AN ABSTRACT OF THE THESIS OF

Analysis of Post-exposure Density Growth in Radiochromic Film with Respect to the Radiation Dose

GAFCHROMIC HD-810 Radiochromic Dosimetry Film Configuration, Specifications and Performance Data

Homogeneity of GAFCHROMIC EBT2 film among different lot numbers

A study of GafChromic XR Type R film response with reflective-type densitometers and economical flatbed scanners

Effective energy measurement using radiochromic film: application of a mobile scanner

Post-irradiation colouration of Gafchromic EBT radiochromic film

Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry

NOT FOR DISTRIBUTION JINST_083P_0914 v1

Grid patterns, spatial inter-scan variations and scanning reading repeatability in radiochromic film dosimetry

QA Considerations. QA for LGK Perfexion : : Follow NRC licensing guidelines (10( CFR ) Leksell Gamma Knife Perfexion

Development of new dosimeter for measuring dose distribution in CT

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

A Study of Slanted-Edge MTF Stability and Repeatability

When small things matter. Small Field Dosimetry Application Guide

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Comparison of measured Varian Clinac 21EX and TrueBeam accelerator electron field characteristics

Comparing three UV wavelengths for pre-exposing Gafchromic EBT2 and EBT3 films

Energy dependence of radiochromic dosimetry films for use in radiotherapy verification

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

CBT-120-UV LEDs. CBT-120-UV Product Datasheet. Features: Table of Contents. Applications

Use of XR-QA2 radiochromic films for quantitative imaging of a synchrotron radiation beam

Commissioning. Basic machine performance MLC Dose rate control Gantry speed control End-to-end tests

Monte Carlo study on a new concept of a scanning photon beam system for IMRT

Nathan Childress, Ph.D., DABR

Characterisation of gafchromic EBT2 film for use in radiation therapy dosimetry

KODAK Panchromatic Separation Film 2238

Color Management User Guide

CBT-120-UV LEDs. CBT-120-UV Product Datasheet. Features: Table of Contents. Applications

PHYSICS QUESTIONNAIRE FORM

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Isocenter and Field of View Accuracy Measurement Software for Linear Accelerator

CBT-90-UV-405 LEDs. CBT-90-UV-405 CBT-120 Product Datasheet. Features: Table of Contents. Applications

Digital Imaging Performance Report for Indus International, Inc. October 27, by Don Williams Image Science Associates.

Photomultiplier Tube

Parameters of Image Quality

A Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images

Cylindrical Ion Chambers

Monitoring Process RA-4 for Silver-Halide Digital Printers

CBT-90-UV LEDs. CBT-90-UV CBT-120 Product Datasheet Preliminary. Features: Table of Contents. Applications

Film Replacement in Radiographic Weld Inspection The New ISO Standard

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

HANDBOOK ON INDUSTRIAL PROPERTY INFORMATION AND DOCUMENTATION

The future of the broadloom inspection

Investigation of the film Kodak MX 125 in Agfa NDT S eco processing

Characterization, Commissioning and Evaluation of Delta 4 IMRT QA System. Ram Sadagopan 1 UTMD Anderson Cancer Center Houston, TX.

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

Cylindrical Ion Chambers Victoreen Model 550 Series

TECHNICAL DATA. benefits

SCINTILLATING FIBER DOSIMETER ARRAY

KODAK PRIMETIME 640T Teleproduction Film / 5620,7620

Commercial Scanners and Science

A. Trianni 1, D. Gasparini 2 and R. Padovani 1

Digital Radiography : Flat Panel

Introduction of a Single Chip TLD System for Patient Dosimetry

) was derived from 50% of the central axis dose created by nominal light field using geometry and mathematical methods. Leaf position (X mlc.

Appearance Match between Soft Copy and Hard Copy under Mixed Chromatic Adaptation

STEREOTACTIC BREAST BIOPSY EQUIPMENT SURVEYS

Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

This is the author s version of a work that was submitted/accepted for publication in the following source:

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

ABSORBED DOSE DISTRIBUTIONS USING THE ISODENSITOMETRIC METHOD FOR EXPOSURES WITH FILTER EMPLOYED FOR MAMMOGRAPHIES

8/3/2016. The EPID Strikes Back. Novel Applications for Current EPID Technology. Joerg Rottmann, PhD. Disclosures and acknowledgements

Image Display and Perception

Migration from Contrast Transfer Function to ISO Spatial Frequency Response

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

KODAK VISION Expression 500T Color Negative Film / 5284, 7284

CRISATEL High Resolution Multispectral System

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

EASTMAN EXR 200T Film / 5293, 7293

A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering

EASTMAN EXR 200T Film 5287, 7287

Commissioning and Calibrating a Linear Accelerator State-of-the-Art in 2010

Digital Hardcopy Xenon Light Stability. Test Report for. Mohawk Fine Papers, Inc.

Computer Output Microfilm Data Sheet

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

SUSPENSION CRITERIA FOR IMAGE MONITORS AND VIEWING BOXES.

CERTIFIED PROFESSIONAL PHOTOGRAPHER (CPP) TEST SPECIFICATIONS CAMERA, LENSES AND ATTACHMENTS (12%)

High Luminous Efficacy Red LED Emitter LZ1-00R100. Key Features. Typical Applications. Description

DISC QC/QA Program for Digital Imaging Systems using the DR Radchex Plus Meter

High Luminous Efficacy RGB LED Emitter LZ4-00MC00. Key Features. Typical Applications. Description

How interference filters can outperform colored glass filters in automated vision applications

ISO INTERNATIONAL STANDARD. Photography Electronic scanners for photographic images Dynamic range measurements

Nuclear Associates

Investigation of the film FUJIFILM IX 80 in TETENAL machine processing


Computed Radiography

Overview of Safety Code 35

7/23/2014. Acknowledgements. Implementing a new digital medical accelerator. New Generation of Medical Accelerators

Transcription:

State of the Art Film Dosimetry Micke A., Lewis D. Advanced Materials Ashland proprietary technology, patents pending

Film Dosimetry Radiochromic Film EBT2/EBT3 One-Scan Protocol Multi-channel Film Dosimetry FilmQA Pro software

Radiochromic Film A film that changes color on exposure to ionizing radiation Color change instantly No chemical or physical processing

Films for Dose Measurement Radiotherapy MV photons, electrons, protons EBT2/EBT3-1 cgy to >40 Gy MD-55-V2-2 Gy to 100 Gy HD-810-10 Gy to 400 Gy Radiology kv photons XR-RV3-5 cgy to 15 Gy XRQA2-1 mgy to 20 cgy

EBT2 and EBT3 - Configuration EBT2 EBT3

Radiochromic Film Trends Trends in conformal therapy Less fractions Higher doses per fraction Tighter conformity Arc therapy Trends place high value on radiochromic film High spatial resolution Wide dynamic range Angular independence

EBT2/3 - Dose Range Dynamic range ~2 cgy to >>40 Gy

EBT2/3 Spatial Resolution Measure, recognize reality 5 dpi vs. 1000 dpi

EBT2/3 Benefits at a Glance High spatial resolution Shoot from any angle Near water-equivalent Nearly energy independent Handle in light Cut to size, bend to shape Immerse in water Wide dynamic range Highly valuable for new conformal therapies

Measuring Gafchromic Film Color reference chart Densitometer Scanner Flatbed 16 bit/channel Preferably RGB (enables multi-channel) Epson flatbed scanners 10000XL + transparency adapter area 12.2 x 17.2 V700, V750, 1680 and 4990 area 8 x 10

Measuring Color Correction Disable color correction options! Epson: Check No Color Correction

Measuring Color Correction Off On

Response, red channel Measuring Scan Orientation 50000 Orientation Dependence EBT3 A101711; 10000XL scanner 45000 40000 Landscape Portrait 35000 30000 25000 20000 0 50 100 150 200 250 300 350 Dose, cgy Both deliver similar results choose and be consistent!

Scanner response Measuring Scan Orientation 35000 Angular Dependence of EBT2 Red Channel Blue Channel 30000 25000 20000 15000 Portrai Landscap 0 30 60 90 120 150 180 Rotation Angle 5 misalignment on scanner Response error is ~0.05% per degree Dose error ~0.05 0.2% per degree (0-300 cgy)

Measuring Lateral Effect Menegotti et al. 2008 Med. Phys., 35, 3078-84, Epson 1680, Red channel Color value depends on lateral scanner position Scanner specific, strong in R, weaker in G + B

Response Realive response Measuring Lateral Effect Lateral Position Dependence Lateral Position Dependence 48000 45000 42000 39000 36000 Red, center Green, center Blue, center Red, side Green, side Blue, side 1.10 1.00 0.90 0.80 33000 30000 27000 24000 21000 0.70 0.60 0.50 Red, center Green, center Blue, center Red, side Green, side Blue, side 18000 0 100 200 300 400 Dose, cgy 0.40 0 100 200 300 400 Dose, cgy Color value depends on lateral scanner position Dependence is Scanner specific, strong in R, weaker in G + B

Calibration Lateral Effect Lateral center position Random lateral positions Calibration Regions - Not Films - must be in lateral center!

Dose, Gy Single Channel Lateral Effect 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 0 50 100 150 200 250 300 350 Position, x 0.353 mm Dose map profile Red (single channel method) Dose at lateral scanner edges overstated!

Relative response Measuring Scanner Variation Typical scan-to-scan variation 1.010 1.005 1.000 0.995 0.990 0 2 4 6 8 10 12 Scan # <0.2% color variation 0.2 1.0% dose variation (dose range 0-500cGy)

Response relative to average Measuring Scanner Variation 1.010 Accidental Scan-to-scan RGB Variation Red channel 1.005 Green channel Blue channel 1.000 0.995 0.990 0 2 4 6 8 10 12 Scan # >0.5% color variation 0.5 2.5% dose variation (dose range 0-500cGy)

Response relative to average Measuring Scanner Variation 1.010 Accidental Scan-to-scan Variation vs Dose 331 cgy, red channel 110 cgy, red channel 1.005 Unexposed, red channel 1.000 0.995 0.990 0 2 4 6 8 10 12 Scan # Synchronic change with dose (Red channel)

Relative response Measuring Film Flatness Scanner Glass 1.00 Film flatness (Curl) and response 0.90 0.80 0.70 0.60 0.50 0.40 Film raised - red Film raised - green Film raised - blue Film on glass - red Film on glass - green Film on glass - blue 0 50 100 150 200 250 300 350 Dose, cgy Callier effect - Light change from collimated to diffused Avoidable!

Relative response Measuring Film Flatness Scanner Glass Glass/plastic sheet 1.00 Flat film and response 0.90 0.80 0.70 0.60 0.50 0.40 Side 1 - red Side 1 - green Side 1 - blue Side 2 - red Side 2 - green Side 2 - blue 0 50 100 150 200 250 300 350 Dose, cgy Rescan solves the problem Multi-channel dosimetry recognizes such disturbances!

Measuring Scanner effect Transmission vs. Reflection Transmission Flatter calibration curves wider dose range Reflection Steeper calibration curves smaller dose range

Measuring Scanner effect Transmission vs. Reflection Transmission Gamma function 2%/2mm: R: 98.3%; G: 97.8%; B: 98.1% Reflection Gamma function 2%/2mm: R: 98.3%; G: 98.9%; B: 98.7% Both deliver similar results choose and be consistent!

Measuring Scanner effect Transmission vs. Reflection Property Transmission Reflection Low dose response ++ Dynamic range ++ Lateral response artifact + Scan-to-scan consistency = = Film flatness + Humidity dependence +

Optical density Measuring Post Exposure Time GAFCHROMIC EBT2: Post-Exposure Changes 0.6 0.5 0.4 0.3 0.2 0.1 0.5Gy 1Gy 1.5Gy 0.0 2.5Gy 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Log10(time, minutes) Logarithmic growth approaching asymptotic value

Measuring Post Exposure Time ΔD t Absolute aging Compensate by waiting t = 24 h ΔD(t) < 0.5%

Measuring - Other Factors Limit exposure to light don t expose to UV Results temperature dependent reversible Don t expose to high temperature >60 C non-reversible Results humidity dependent reversible, watch gradients!

Conclusion? Film is a hassle! Advantages, but Post-exposure waiting Film artifacts Scanner artifacts Many constant conditions

Basic Idea One-scan Protocol All data measured in a single scan Do calibration + evaluation with same scan = same conditions Using reference strips with same post exposure age Problem How to fit everything into One Scan (many calibration points)? How to calibrate (single exposure)?

One-Scan - Post Exposure Age ΔD t ΔD t Δt Absolute aging wait t = 24 h ΔD(t) < 0.5% Relative aging wait t = 4 Δt ΔD(t) < 0.5%

One-Scan Post Exposure Age Expose application and reference films in a narrow time window Wait before scanning, min. Exposure window, min. Dose error 10 5 <1% 20 5 <0.5% 40 5 <0.25%

Response Response Calibration Post Exposure Age Post-Exposure Changes, Absolute, red channel - EBT3 A101711 50000 45000 40000 48500 48300 48100 47900 47700 65 min 120 min 255 min 490 min 1440 min 4800 min 65 min 120 min 255 min 490 min 35000 47500 0 5 10 Dose, cgy 1440 min 4800 min 30000 25000 20000 0 100 200 300 400 500 600 Dose, cgy Curves look similar convertible?

Relative response Calibration Post Exposure Age Scaled relative responses 1.10 1.00 0.90 0.80 0.70 Red, 65 min. Green, 65 min. Blue, 65 min. Red, 24 hr. Green, 24 hr. Blue, 24 hr. Color scaling Color( 0 ) = const Color(D max ) = const 0.60 0.50 0.40 0 50 100 150 200 250 300 350 400 450 500 Dose, cgy All calibration curves have same Shape! Can be converted by shifting + stretching

Calibration Curve Shape Experimental comparisons: Different scanners Epson 10000XL, V700, 1680 Different scan temperatures Different humidity levels Different photon energies Different orientations landscape and portrait Calibration curves are Shape invariant! Curves can be converted by 2 point rescaling

Normalized/scaled Response, red channel Calibration Curve Shape 1.000 0.900 0.800 EBT3 A071111 EBT2 A072511 EBT3 A101711 EBT3 A121411-1 0.700 0.600 0.500 0.400 0 100 200 300 400 500 Dose, cgy Calibration curves of different EBT lots are NOT Shape invariant!

Procedure One-scan Protocol Set up and expose treatment plan Expose reference film (same lot) with flat field ~80-100% D max Single scan of patient film, reference and unexposed strip Use reference films to re-scale calibration Lewis, Micke, Yu, Chan Med. Physics, 39 (2012) 10, pp. 6339.

Compensates One-scan Protocol Any scan to scan variation Ambient conditions temperature, humidity Mitigates Energy dependence Does Not compensate Local disturbances Film non-uniformities, curl, Newton ring pattern, noise Lateral scanner effect Calibration errors (curve shape)

One-Scan Protocol - EBT3 Plus Configuration same as EBT3 Attached reference strip Strip properties same as patient film as close as possible Perforated Sheet easy to detach reference strip Saves film cutting Standardized strip size EBT3+ available November 2012

Conclusion Film is a hassle! Advantages, but Post-exposure waiting Film artifacts Scanner artifacts Many constant conditions

Single Channel Film Dosimetry Calibration Curve X=R R ave = R ave (D) D R = D R (R ave ) Color channels X=RGB D X = D( X ave ) correlates (measures) average system response linac+film+scanner+protocol Unique mapping between X value and dose D X (X)

Single Channel Film Dosimetry Rational function X( D ) = A + B / (D C) use to fit calibration data Correct asymptotic lim X D = A D Easily invertible D( X ) = C + B / (X A) Only 3 parameters reduces calibration to 2 exposures + blank film

Single Channel Film Dosimetry D=D X Robust explicit (simple) calculation method any X value delivers dose D X (X) Calibration data easy to correlate But, receptive to disturbances

Single Channel Film Dosimetry Problem: Specific pixel does not behaves like average Disturbance ΔX generates ΔD X X + ΔX D( X ) + ΔD X Film uniformity variations Scanner non-linearities Newton rings, noise, finger prints curling, Any X value delivers dose D X (X) Each channel specific ΔD X No indication of big ΔD X What dose D X is best?

Multi-Channel Film Dosimetry RGB Calibration Curves Dose induced color C C(D) = {R(D),G(D),B(D)} Dose exposure generates only certain colors C Not all C deliver dose value Observed color C scan is superposed with disturbance ΔC C scan = C(D) + ΔC Solution: Optimize dose D value, i.e. minimize ΔC C scan - C(D) min D

Triple Channel Film Dosimetry Model: Scanned optical density d X,scan d X,scan ( D ) = d X,D ( D ) * Δd d X = -log( X ) for X = RGB d X,D is calibration function (average behavior)! disturbance Δd independent of dose + X (wave length)! but Δd = Δd( thickness, scanner, noise, artifacts ) Solution: Minimized function vs. disturbance Δd: (Δd) = ( D R - D B ) 2 + ( D B - D G ) 2 + ( D G - D R ) 2 min Δd

Triple Channel Film Dosimetry Example Signal split into dose dependent and dose independent part D RGB + Δd Dose map (dose dependent part) Disturbance Δd map (dose independent part) includes film uniformity variations, noise etc.

Triple Channel Dosimetry Film Consistency Film consistent with Calibration Patches Film has same dose response for X=RGB i.e. same dose values D X are calculable Offset between D X measures calibration consistency Example: Profiles original calibration patch and 90 rotated scan

Triple Channel Dosimetry Consistency Map Dose map measurement result Disturbance map removed error Consistency map remaining dose error ideal case: noise only Film Dose Map Disturbance Map Consistency Map (dark = +, light = -, contrast maximized) Example: dominated by scanner cogging

Multi Channel Calibration Optimize Calibration Lower consistency = better calibration Offset in calibration points is not a quality criterion Calibration goal Correlate calibration parameter for best (perfect) consistency Calibration function C( D ) = { R( D ), G( D ), B( D) } matches film dose spectrum Perfect consistency 0

Multi Channel Calibration Single channel calibration average system response x = x( D ) x = RGB each channel fitted separately Multi-channel calibration X( D ) = A + B x( a + b D ) X = RGB rescales calibration x a, b dose scaling, A, B color scaling Correlation D R ( R ref ) = D G ( G ref ) = D B ( B ref ) optimize consistency at reference points Compensates calibration patch distortions if multi channel dose is used to rescale dose

Multi Channel Calibration Two point recalibration 1 unexposed + 1 exposed film Minim cost possible Dose scaling (A=0, B=1) X( D ) = x( a + b D ), X = RGB Color scaling (a=0, b=1) X( D ) = A + B x( D ), X = RGB Assumption Calibration functions keep shape Shape(x) = Shape(X), x, X=RGB Single scan Evaluation compensates for Ambient conditions: temperature, humidity Inter-scan scanner variations, Post exposure time, film aging

Consistency Comparison Single Channel 10.2 cgy Single Channel Recalibrated 3.6 cgy Multi Channel 1.3 cgy Multi Channel Recalibrated 1.2 cgy Consistency measured across frame D max = 243 cgy, D ave = 139 cgy

Triple Channel Dosimetry Dose Map Consistency Dose map error estimation known before comparison Detect abnormal scans 90 rotation, curling, Newton rings, top sheets anomaly Example dose consistency map (iso-map) peak error ~2%

Dose, Gy Triple Channel Dosimetry Lateral Scanner Non-Linearity Scanner signal changes with lateral position (sensor direction) EBT film polarization causes lateral effect Non-dose-dependent part of lateral effect is compensated Mitigation only (partial compensation) 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 Red channel dosimetry Triple channel dosimetry 0 50 100 150 200 250 300 350 Position, x 0.353 mm

Lateral Scanner Non-Linearity Single vs. Triple Channel Passing rate Gamma map Criterion Calibration Composite Single Channel Triple Channel 90% 96% Calibration Calibration 2% / 2mm 87% 96% 98% 98% 94% 97% 1% / 1mm 58% 71% 64% 69% 81% 85% 73% 78% = centered = right edge absolute dosimetry (no dose re-scaling), <5% (<12cG) lowest dose ignored, Composite 1.00 0.98 0.96 0.94 0.92 0.90 0.88 0.86 0 500 Composite

scan direction Lateral Scanner Non-Linearity Normalized Blank Scan Lateral effect increases with dose Compensates only weakest occurrence of lateral effect Adding disturbances Non-uniformity of blank film Noise of blank scan Worsens consistency for exposed areas 1.00 0.98 0.96 0.94 0.92 0.90 0.88 0.86 0 500 Calibration patch consistency comparison dose <cgy> Consistency <cgy> Consistency <%> None Blank scan None Blank scan 202.0 8.8 11.1 4.3 5.5 151.5 6.8 8.9 4.5 5.9! DO NOT USE! 101.0 5.9 8.4 5.9 8.3 50.5 5.9 7.9 11.6 15.6 0.0 4.8 0.4 Infinity Infinity

Lateral Scanner Non-Linearity Normalized Blank Scan Dose cgy Usable Scanner Width Triple Channel Dosimetry Usable Scanner Width Green + Blue Channel Dosimetry 250 full (26 cm) 500 24 cm 1000 18 cm 2000 14 cm full (26 cm) 3000 6 cm 20 cm 4000 5 cm 20 cm Dose error < 1%

Triple Channel Film Dosimetry Dose to Plan Comparison Triple Channel Passing rate R 97.15 % Single Channel Passing rate R - 87.48 % Gamma Map 2%/2mm - IMRT example (part of FilmQA Pro installation)

Triple Channel Film Dosimetry Dose to Plan Comparison Dose map error can dominate comparison 1% achievable (vs. 3% with single channel method) Comparison Criteria 3%/3mm, 2%/2mm Triple channel: 1% << 3%/2%, i.e. majority < tolerance Single channel: 3% ~ 3% test, i.e. 50% > tolerance Passing rates improves more than dose accuracy

Gamma Map Comparison plan pixel and overlaid pixels of registered dose map same standard deviation low sample number fails, high sample number passes Use dose average across plan pixel e.g. Projection of dose map to plan coordinate system Filtering cannot fix this problem!

Single vs. Triple Channel Noise Dependence Triple Channel Passing rate Single Channel Passing rate Criterion 0% noise 0.5% noise 1% noise 2% noise Criterion 0% noise 0.5% noise 1% noise 2% noise 3% / 3mm 97% 96% 95% 95% 2% / 2mm 94% 96% 94% 87% 1% / 1mm 68% 70% 58% 41% 3% / 3mm 94% 95% 95% 94% 2% / 2mm 89% 92% 94% 91% 1% / 1mm 57% 65% 61% 48% 2% / 2 mm Gamma map comparison at 0%, 2% noise White noise with various standard deviation added to EBT3 film scan, Gamma map with projection

Triple Channel Film Dosimetry Dynamic Dose Range Same dose mapping method for all channels Range adaptation as needed Enables EBT s full dynamic range - Factor >1000 Lateral effect increases substantially! Example - Brachytherapy: Calibration range 0 40 Gy, Dose map 22 Gy peak, Reference 9 Gy

Triple Channel, Single Scan Film Dosimetry Separate Dose and Dose-independent effects Compensates for film thickness variation Noise reduction without dose change Mitigates scanner distortions Background compensation, double exposure unnecessary Enables entire film dose range Ebt2 dynamic range ratio >1000 (1 cgy - >40 Gy) Significant improvement of dose map accuracy <1% achievable (vs. 3% with single channel method) Optimized calibration per specific scan Indication of inconsistency between film and calibration, calibration inconsistencies

Conclusion! Film is a hassle! Fast results after minutes Accurate results <1% Simple operation

Micke, Lewis, Yu - Multi-channel Film Dosimetry with Non-Uniformity Correction, Medical Physics, 38 (2011) 5, pp. 2523. Lewis, Micke, Yu, Chan - An Efficient Protocol for Radiochromic Film Dosimetry combining Calibration and Measurement in a Single Scan, Medical Physics, 39 (2012) 10, pp. 6339.