THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12STGN500 THHN 12 STR Green 500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

SIMpull THHN, it slips and slides - all with NoLube.

THHN2BK2500 THHN 2 STR Black 2500

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

SECTION BUILDING WIRE AND CABLE

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Instrumentation Cables

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

CIR (Crush & Impact Resistant) VFD Power Cable

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

BX /2 Solid Ac/BX Aluminum Cable

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)

Shielded Fire Alarm Cables

DataTwist 5 ScTP Cable

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Detailed Specifications & Technical Data

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

14 AWG 2 AWG: 600 Volt

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

DLO Flexible Power Cable

GEXOL WORLD CLASS OIL & GAS CABLES

SUBMITTAL COVER SHEET

Communication, Control, and Industrial Cable

Detailed Specifications & Technical Data

WIRE&CABLE FILS&CÂBLES S I N C E

Industrial Data Solutions Industrial Ethernet Cables Category 5e DataTuff Twisted Pair Cables Heavy Duty Sunlight- and Oil-Resistant Jackets

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

WIRE AND CABLE SECTION M WIRE AND CABLE. TEW / TEWN and TR-64 Wire. SPT1 / SPT2 / SEW1 AND SEW2 Wire. SVT / SJT / SO AND SOOW Cords

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Industrial Automation & Control Cables

Creating. There is one basic question every customer needs to address when creating custom

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

TIGER BRAND MINING CABLES

Standard Lengths of. Code Ft. m

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Detailed Specifications & Technical Data

Drop Cable Product Catalog

Four Cat 5e 24 AW G Bonded-Pairs solid bare copper conductors, polyolefin insulation, PVC jacket.

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

For tough, seaworthy wire

Multi-Paired Cable Product Finder

Nexans Industrial Solutions PRODUCT CATALOG

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU

IMSA TRAFFIC SIGNAL CABLE

SECTION Q WIRE AND CABLE Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:

Communication and Control Cable Pro Audio and Intercom Systems Unshielded

SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection

A. Product Description: Stranded conductor insulated wire.

AEE. Canada. Australia

Cable Solutions FOR THE INDUSTRIAL AUTOMATION MARKET

MachFlex Industrial Cables

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

Information technology. Generic cabling systems, General requirements

Analog Multi-Pair Snake Cable

High Temperature Flexible Control Cable

Composite Data, Audio, Video, Security and Control Cables Banana Peel Jacketless Cables Category 5e

Speaker Audio System Cables

MHR-2 Two Conductor Mini High Resolution S-Video Cable

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

HOOK-UP WIRE A STYLE TO SUIT ANY NEED

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

Product Bulletin. Belden DataTwist 4800 Cables

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

Section 4. Multi-Conductor

TABLE OF CONTENTS. ANALOG AUDIO CABLES pages NETWORK CABLES pages DIGITAL AUDIO CABLES pages APPENDIX pages

Journeyman's Practice Exam

Power-limited Circuit Cable. Features & Applications: Specification. Power-limited Circuit Cable


WELCOME On-Line Catalog Features

Content. - DDF Frame Pair Screen Cable Pair Screen Cable

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Industrial Data. Conductor (stranding) Diameter Nom. DCR. Shielding Materials Nom. DCR. Color Code. (2)18 AWG TC Data Pair:

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG

HELUKABEL UL-LISTED CABLES

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Continuous Flex Data Cable


2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

ADVANCED FLAT CABLE SOLUTIONS

Transcription:

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT

SouThWire the PeoPLe Southwire started as a small operation in Carrollton, Georgia with 12 employees in 1950. Today, the company employs more than 3,500 people at sales offices, customer service centers and manufacturing facilities throughout North America. Southwire s employees are dedicated to the company s founding principles of developing quality products matched with quality service. While others have come and gone, and come again, Southwire has remained a constant and reliable manufacturer and supplier of wire and cable products for more than 60 years. SouThWire the SerVice With customer service centers strategically located across the country, Southwire can fill all of your HVAC product needs where you need them, when you need them, resulting in savings of time and money. The broad product range, combined with these customer service centers mean you get more products in fewer deliveries. SouThWire the ProductS Southwire provides a full line of products, in both copper and aluminum, for a wide range of applications. The company leads the industry in new and innovative products that help you save time and money. In addition to its standard product line, Southwire can also manufacture custom products offering its customers the most complete line of products for almost any requirement or situation. No matter what the commercial or industrial application requires, you need look no farther. Southwire has just the right HVAC product offering you re looking for. SouthWire company offers ProductS that offer SoLutionS. SouThWire The company SINCe 1950, SouTHWIre HAS been on THe move, GroWING ANd evolving INTo NorTH AmerICA S largest WIre ANd CAble producer ANd SupplIer. WITH INNoVATIoN backed by experience, SouTHWIre leads THe INduSTry WITH THe broadest line of WIre ANd CAble products.

TABLE OF CONTENTS SOUTHWIRE-THE COMMITMENT Solid company. Dedicated people. Quality products. Dependable service. Product innovation. Made in the USA. SOUTHWIRE COMPANY OFFERS PRODUCTS THAT OFFER SOLUTIONS. HVAC CABLE SIMpull THERMOSTAT WIRE... 2 THERMOSTAT WIRE RISER RATED... 4 THERMOSTAT WIRE RISER RATED SHIELDED... 6 THERMOSTAT WIRE PLENUM RATED... 8 THERMOSTAT WIRE PLENUM RATED SHIELDED... 10 MINI-SPLIT WIRE 300 VOLT SHIELDED... 12 MINI-SPLIT TRAY CABLE 600 VOLT... 13 ULTRA-WHIP PRE-ASSEMBLED NON-METALLIC HOOK-UP WHIPS... 14 THHN/THWN/TWN75/T90... 16 TFFN/TFN/TEWN... 18 ROMEX SIMpull TYPE NM-B... 20 QUANTUM TPE TYPE SJEOOW 105 C 300 VOLT UL/CSA TPE PORTABLE CORD... 22 QUANTUM TPE TYPE SEOOW 105 C 600 VOLT UL/CSA TPE PORTABLE CORD... 24 ULTRATITE TYPE NM LIQUIDTIGHT FLEXIBLE NON-METALLIC CONDUIT... 26 ARMORLITE TYPE MC... 28 COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E RISER RATED - CMR... 30 COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E PLENUM RATED - CMP... 32 TEMPERATURE CONTROL CABLE PLENUM RATED / NON-PLENUM RATED... 34 PIGTAILS POWER SUPPLY CORDS SPT-3 STRAIGHT AND RIGHT ANGLE... 36 1

SIMpull THERMOSTAT WIRE APPLICATIONS Suitable for use as follows: SIMpull Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications STANDARDS & REFERENCES 150 Voltage rating per NEC Article 725 ETL listed to UL 13 Meets UL 1581 Vertical Tray Flame Test (FT-1) Type CL2 CONSTRUCTION Solid copper conductors with 6 mils of PVC insulation Conductors are covered with a brown PVC jacket using SIM (SLIKQWIK Infused Membrane) for easier pulling resulting in easier installation Ripcord Rated 150 Volt Sunlight-Resistant -20 C to +60 C 18 and 20 Gauge Copper Conductors SIM Jacket Designed for Easier Pulling 2

HVAC WEIGHTS, MEASUREMENTS AND PACKAGING SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS 18 GAUGE THERMOSTAT WIRE JACKET THICKNESS NOM. (mils) APPROX. OVERALL CABLE DIAMETER (mils) APPROX. NET WEIGHT (lbs/1000 ft) 18/2 Red, White 14 132 16 18/3 Red, White, Green 14 140 22 18/4 Red, White, Green, Blue 14 154 28 18/5 18/6 18/7 18/8 18/9 18/10 18/12 Red, White, Green, Blue, Yellow Red, White, Green, Blue, Yellow, Brown Yellow, Brown, Orange Yellow, Brown, Orange, Black Yellow, Brown, Orange, Black, Pink Yellow, Brown, Orange, Black, Pink, Gray Yellow, Brown, Orange, Black, Pink, Gray, Tan, Purple 15 170 34 15 186 44 15 186 45 15 202 52 15 218 57 15 246 65 15 245 74 All SIMpull Thermostat Wire is constructed with solid conductors, PVC insulation (6 mils), parallel conductors, PVC jacket, 25 pf/ft capacitance between conductors @ 1 KHz (nom.), and 6.32 Ohms/1000 foot DC resistance per conductor @ 20 C (nom.). 20 GAUGE THERMOSTAT WIRE SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS JACKET THICKNESS NOM. (mils) APPROX. OVERALL CABLE DIAMETER (mils) APPROX. NET WEIGHT (lbs/1000 ft) SIMpull THERMOSTAT WIRE 20/2 Red, White 14 114 11 20/3 Red, White, Green 14 121 15 20/4 Red, White, Green, Blue 14 132 18 20/5 20/6 20/7 20/8 20/9 20/10 20/12 Red, White, Green, Blue, Yellow Red, White, Green, Blue, Yellow, Brown Yellow, Brown, Orange Yellow, Brown, Orange, Black Yellow, Brown, Orange, Black, Pink Yellow, Brown, Orange, Black, Pink, Gray Yellow, Brown, Orange, Black, Pink, Gray, Tan, Purple 15 147 22 15 160 26 15 160 29 15 173 33 15 185 37 15 202 40 15 209 47 All SIMpull Thermostat Wire is constructed with solid conductors, PVC insulation (6 mils), parallel conductors, PVC jacket, 22 pf/ft capacitance between conductors @ 1 KHz (nom.), and 10.73 Ohms/1000 foot DC resistance per conductor @ 20 C (nom.). 3

THERMOSTAT WIRE RISER RATED APPLICATIONS Suitable for use as follows: Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications from floor to floor and up access shafts without conduit STANDARDS & REFERENCES 150 Voltage rating per NEC Article 725 ETL listed to UL 13 Meets UL 1581 Vertical Tray Flame Test (FT-1) Type CL2R CONSTRUCTION Solid copper conductors with 6 mils of PVC insulation Conductors are covered with a brown PVC jacket Ripcord Rated 150 Volt Sunlight-Resistant -20 C to +60 C 18 and 20 Gauge Copper Conductors 4

HVAC WEIGHTS, MEASUREMENTS AND PACKAGING SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS 18 GAUGE THERMOSTAT WIRE JACKET THICKNESS NOM. (mils) APPROX. OVERALL CABLE DIAMETER (mils) APPROX. NET WEIGHT (lbs/1000 ft) 18/2 Red, White 15 144 16 18/3 Red, White, Green 15 153 22 18/4 Red, White, Green, Blue 15 167 28 18/5 18/6 18/7 18/8 18/9 18/10 18/12 Red, White, Green, Blue, Yellow Red, White, Green, Blue, Yellow, Brown Yellow, Brown, Orange Yellow, Brown, Orange, Black Yellow, Brown, Orange, Black, Pink Yellow, Brown, Orange, Black, Pink, Gray Yellow, Brown, Orange, Black, Pink, Gray, Tan, Purple 15 182 34 15 190 44 15 199 46 15 215 52 15 232 59 15 253 65 15 262 77 All Thermostat Wire is constructed with solid conductors, PVC insulation (6 mils), parallel conductors, PVC jacket, 25 pf/ft capacitance between conductors @ 1 KHz (nom.), and 6.32 Ohms/1000 foot DC resistance per conductor @ 20 C (nom.). 20 GAUGE THERMOSTAT WIRE SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS JACKET THICKNESS NOM. (mils) APPROX. OVERALL CABLE DIAMETER (mils) APPROX. NET WEIGHT (lbs/1000 ft) THERMOSTAT WIRE RISER RATED 20/2 Red, White 14 128 11 20/3 Red, White, Green 14 133 15 20/4 Red, White, Green, Blue 14 147 19 20/5 20/6 20/7 20/8 20/9 20/10 20/12 Red, White, Green, Blue, Yellow Red, White, Green, Blue, Yellow, Brown Yellow, Brown, Orange Yellow, Brown, Orange, Black Yellow, Brown, Orange, Black, Pink Yellow, Brown, Orange, Black, Pink, Gray Yellow, Brown, Orange, Black, Pink, Gray, Tan, Purple 15 160 24 15 174 28 15 174 32 15 188 36 15 202 40 15 220 44 15 227 51 All Thermostat Wire is constructed with solid conductors, PVC insulation (6 mils), parallel conductors, PVC jacket, 22 pf/ft capacitance between conductors @ 1 KHz (nom.), and 10.73 Ohms/1000 foot DC resistance per conductor @ 20 C (nom.). 5

THERMOSTAT WIRE RISER RATED SHIELDED APPLICATIONS Suitable for use as follows: Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications STANDARDS & REFERENCES 150 Voltage rating per NEC Article 725 ETL listed to UL 13 Meets UL 1581 Vertical Tray Flame Test (FT-1) Type CL2R CONSTRUCTION Solid or stranded copper conductors with 6 mils of PVC insulation Conductors are paralleled and covered with a brown PVC jacket Ripcord Rated 150 Volt Sunlight-Resistant -20 C to +60 C 18 Gauge Copper Conductors 6

HVAC WEIGHTS, MEASUREMENTS AND PACKAGING SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS 18 GAUGE SOLID JACKET THICKNESS NOM. (mils) APPROX. OVERALL CABLE DIAMETER (mils) APPROX. NET WEIGHT (lbs/1000 ft) 18/2 Red, White 15 148 17 18/3 Red, White, Green 15 157 23 18/4 Red, White, Green, Blue 15 171 29 18/5 18/6 18/8 Red, White, Green, Blue, Yellow Red, White, Green, Blue, Yellow, Brown Yellow, Brown, Orange, Black 15 186 35 15 202 41 15 219 53 All Thermostat Wire is constructed with solid conductors, PVC insulation (6 mils), parallel conductors, PVC jacket, 25 pf/ft capacitance between conductors @ 1 KHz (nom.), and 6.32 Ohms/1000 foot DC resistance per conductor @ 20 C (nom.). 18 GAUGE STRANDED SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS JACKET THICKNESS NOM. (mils) APPROX. OVERALL CABLE DIAMETER (mils) APPROX. NET WEIGHT (lbs/1000 ft) 18/2 Red, White 15 157 17 18/3 Red, White, Green 15 167 24 18/4 Red, White, Green, Blue 15 181 30 18/5 18/6 18/8 Red, White, Green, Blue, Yellow Red, White, Green, Blue, Yellow, Brown Yellow, Brown, Orange, Black 15 197 36 15 214 43 15 237 55 All Thermostat Wire is constructed with solid conductors, PVC insulation (6 mils), parallel conductors, PVC jacket, 22 pf/ft capacitance between conductors @ 1 KHz (nom.), and 10.73 Ohms/1000 foot DC resistance per conductor @ 20 C (nom.). THERMOSTAT WIRE RISER RATED SHIELDED 7

THERMOSTAT WIRE PLENUM RATED APPLICATIONS Suitable for use as follows: Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications STANDARDS & REFERENCES 300 Voltage rating per NEC Article 725 ETL listed to UL 13 Meets UL 1581 Vertical Tray Flame Test (FT-1) Type CL2P CONSTRUCTION Solid copper conductors with 9 mils of low smoke PVC insulation Conductors are paralleled and covered with a beige PVC jacket Ripcord Rated 300 Volt Sunlight-Resistant -20 C to +60 C 18 Gauge Copper Conductors 8

HVAC WEIGHTS, MEASUREMENTS AND PACKAGING SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS 18 GAUGE THERMOSTAT WIRE JACKET THICKNESS NOM. (mils) APPROX. OVERALL CABLE DIAMETER (mils) APPROX. NET WEIGHT (lbs/1000 ft) 18/2 Red, White 14 145 16 18/3 Red, White, Green 14 155 22 18/4 Red, White, Green, Blue 14 169 29 18/5 18/6 18/7 18/8 18/10 Red, White, Green, Blue, Yellow Red, White, Green, Blue, Yellow, Brown Yellow, Brown, Orange Yellow, Brown, Orange, Black Yellow, Brown, Orange, Black, Pink, Gray 15 178 35 15 192 41 15 203 48 15 223 54 15 240 67 All Thermostat Wire is constructed with solid conductors, PVC insulation (9 mils), parallel conductors, PVC jacket, 25 pf/ft capacitance between conductors @ 1 KHz (nom.), and 6.32 Ohms/1000 foot DC resistance per conductor @ 20 C (nom.). THERMOSTAT WIRE PLENUM RATED 9

THERMOSTAT WIRE PLENUM RATED SHIELDED APPLICATIONS Suitable for use as follows: Thermostat Wire is a class 2 power-limited circuit cable for use in thermostat control applications STANDARDS & REFERENCES 300 Voltage rating per NEC Article 725 ETL listed as per UL 13 Meets UL 1581 Vertical Tray Flame Test (FT-1) Type CL2P CONSTRUCTION Solid copper conductors with 9 mils of low smoke PVC insulation Conductors are paralleled and covered with a beige low smoke PVC jacket Ripcord Rated 300 Volt Sunlight-Resistant -20 C to +60 C 18 Gauge Copper Conductors Overall Aluminum Mylar Shield with 22 AWG tinned Copper Drain Wire 10

HVAC WEIGHTS, MEASUREMENTS AND PACKAGING SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS 18 GAUGE THERMOSTAT WIRE - SOLID JACKET THICKNESS NOM. (mils) APPROX. OVERALL CABLE DIAMETER (mils) APPROX. NET WEIGHT (lbs/1000 ft) 18/2 Red, White 14 146 16 18/3 Red, White, Green 14 155 24 18/4 Red, White, Green, Blue 14 169 31 18/5 18/6 Red, White, Green, Blue, Yellow Red, White, Green, Blue, Yellow, Brown 15 178 37 15 192 43 All Thermostat Wire is constructed with solid conductors, low smoke PVC insulation (9 mils), parallel conductors, PVC jacket, 25 pf/ft capacitance between conductors @ 1 KHz (nom.), and 6.32 Ohms/1000 foot DC resistance per conductor @ 20 C (nom.). SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS 18 GAUGE THERMOSTAT WIRE - STRANDED JACKET THICKNESS NOM. (mils) APPROX. OVERALL CABLE DIAMETER (mils) APPROX. NET WEIGHT (lbs/1000 ft) 18/2 Red, White 14 146 16 18/3 Red, White, Green 14 155 25 18/4 Red, White, Green, Blue 14 169 32 18/5 18/6 18/8 Red, White, Green, Blue, Yellow Red, White, Green, Blue, Yellow, Brown Yellow, Brown, Orange, Black 15 178 38 15 192 45 15 223 58 All Thermostat Wire is constructed with stranded conductors, low smoke PVC insulation (9 mils), parallel conductors, PVC jacket, 22 pf/ft capacitance between conductors @ 1 KHz (nom.), and 10.73 Ohms/1000 foot DC resistance per conductor @ 20 C (nom.). THERMOSTAT WIRE PLENUM RATED SHIELDED 11

MINI-SPLIT WIRE 300 VOLT SHIELDED APPLICATIONS Suitable for use as follows: Mini-Split Wire is a class 3 power-limited circuit cable used with HVAC Mini-Split systems Also can be used in security and audio applications STANDARDS & REFERENCES 300 Voltage rating per NEC Article 725 Riser Rated UL listed as per UL 13 Meets UL 1581 Vertical Tray Flame Test Type CL3R CONSTRUCTION Stranded copper conductors with 10 mils of PVC insulation The overall jacket is heat, moisture and sunlight resistant PVC Overall Aluminium mylar shield with 24 AWG tinned Copper drain wire 300 Volt CL3R PVC Jacket Rip Cord WEIGHTS, MEASUREMENTS AND PACKAGING SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS JACKET THICKNESS NOM. (mils) / COLOR APPROX. OD (mils) APPROX. NET WT. / MFT 18/2 Black, Red 15 / Gray 159 18 18/4 Black, Red, Green, White 15 / Gray 278 33 16/2 Black, Red 15 / Green 183 25 16/4 Black, Red, Green, White 15 / Green 326 47 14/4 Black, Red, Green, White 15 / White 379 69 12

MINI-SPLIT TRAY CABLE 600 VOLT APPLICATIONS Suitable for use as follows: Tray Cable is a multi-conductor control, signal or power cable rated for 600 volts May be installed in raceways, conduit, cable trays, and outdoor locations where supported by a messenger wire Also suitable for direct burial Temperature rating at 75 C wet locations / 90 C dry locations STANDARDS & REFERENCES UL listed as per UL 1277 Conforms to applicable sections of UL 1581 and 1685 RoHS Compliant Type TC CONSTRUCTION Stranded copper conductors Type THHN or THWN The overall jacket is heat, moisture and sunlight resistant PVC MINI-SPLIT WIRE 300 VOLT SHIELDED /MINI-SPLIT TRAY CABLE 600 VOLT 600 Volt WEIGHTS, MEASUREMENTS AND PACKAGING SIZE (AWG) NUMBER OF CONDUCTORS CONDUCTOR COLORS JACKET THICKNESS NOM. (mils) / COLOR APPROX. OD (mils) APPROX. NET WT. / MFT 14/4 Black, Red, Blue, Orange 45 / Black 350 93 14/7 Black, Red, Blue, Orange, Yellow, Brown, Red with Black Stripe 45 / Black 413 145 Operating Temperature +75 C Wet / +90 C Dry PVC Jacket 13

ULTRA-WHIP PRE-ASSEMBLED NON-METALLIC HOOK-UP WHIPS APPLICATIONS Suitable for use as follows: Complete assembly delivered from the factory ready to install. Includes 12" wire leads at each end and LFNC-B Fittings for easy and hassle-free hook-ups Resistant to rust, cracks, and separation Non-metallic raceway is non-conducting Commonly used for connecting air conditioners, pumps, motors, compressors, swimming pool equipment and similar equipment STANDARDS & REFERENCES Ultra-Whip is UL Listed under the Wiring Assemblies (QQYZ) category. Ultra-Whip complies with NEC Article 356, UL Standard 1660, and CSA Standard C22.2 No 227.2 for Liquidtight Flexible Non-metallic Conduit. The fittings meet UL Standard 514B, CSA Standard C22.2 No.18, and NEMA FB-1. CONSTRUCTION 600 Volt Stranded Copper THHN/THWN Insulated Singles Ultra-Whip is a listed wiring assembly comprised of Listed or Recognized components intended for field installation in accordance with the National Electrical Code. Ultra-Whip is a non-metallic conduit constructed with two different PVC materials that are extruded to form a highly flexible product designed especially for electrical applications. A rigid material forms the stiff helical spring, which is completely encapsulated by a second flexible compound. Stranded Copper THHN/THWN conductors and UL Listed LFNC-B Fittings are installed at the factory. Twelve-inch wire leads are left exposed at each end for hassle-free hook-ups. Green Insulated Copper Grounding Conductor Highly Flexible Non-metallic Conduit with Factory Installed Conductors Liquidtight Flexible Non-metallic Conduit Type B (LFNC-B) Fittings 12" Conductor Leads with 1/2" Insulation Stripped Intended for 208/240/480 Volt Single Phase Circuits 14

HVAC # OF CONDUCTORS WEIGHTS, MEASUREMENTS AND PACKAGING PART NUMBER TRADE SIZE (inches) CONDUIT LENGTH (feet) WIRE SIZE # OF COND./ SIZE AMPERE RATING (AMPS) MASTER CARTON QUANTITY (# OF PIECES) MASTER CARTON WEIGHT (lbs) R124 1/2 4 3/#10 AWG 30 6 12 R126 1/2 6 3/#10 AWG 30 6 13 R344 3/4 4 R346 3/4 6 COLOR SEQUENCE 2 black, red Grounding Conductor COLOR CODING 120/208Y green *Optional 277/480Y Volt Colors are available subject to economic quality. 2/#8 AWG 1/#10 AWG Ground 2/#8 AWG 1/#10 AWG Ground # OF CONDUCTORS 40 6 14 40 6 15 2 brown, grey COLOR SEQUENCE 2 orange, grey 2 yellow, grey 2 purple, grey COLOR CODING 277/480Y HIGH VOLTAGE 3 brown, yellow, grey 3 brown, orange, grey 4 brown, orange, yellow, grey 4 brown, yellow, purple, grey ULTRA WHIP PRE-ASSEMBLED NON-METALLIC HOOK-UP WHIPS 15

THHN/THWN/TWN75/T90 ANNEALED (SOFT) COPPER HEAT AND MOISTURE RESISTANT POLYVINYL CHLORIDE (PVC) NYLON (POLYAMIDE) OR UL-LISTED EQUAL JACKET APPLICATIONS Suitable for use as follows: Southwire Type THHN or THWN-2* conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code 2 When used as Type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90 C When used as Type THWN-2*, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C when exposed to oil or coolant When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 C or dry locations at temperatures not to exceed 90 C (with ampacity limited to that for 75 C conductor temperature per NFPA 79) Conductor temperatures not to exceed 105 C in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts STANDARDS & REFERENCES Southwire Type THHN or THWN-2* or MTW (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code. 600 Volt Copper Conductor Thermoplastic Insulation/Nylon Sheath Heat, Moisture, Gasoline, and Oil Resistant 1 Sizes 8 AWG and Larger Rated THWN-2 All Stranded Sizes Rated MTW and THWN Sizes 14 through 6 AWG Rated AWM (105 C) Sizes 14 through 1 AWG Rated VW-1 CONSTRUCTION Southwire Type THHN or THWN-2* or MTW copper conductors are annealed (soft) copper, insulated with a tough heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) or UL-listed equal jacket is applied Available in black, white, red, blue, green, yellow, brown, orange, and grey; some colors standard, some subject to economic order quantity SPECIFICATIONS MTW or THHN or THWN-2: Conductors shall be UL-listed Type MTW or THHN or THWN-2* gasoline and oil resistant II, suitable for operations at 600 volts as specified in the National Electrical Code. Sizes 14 through 6 AWG shall be rated VW-1. Conductors shall be annealed copper, insulated with high-heat and moisture resistant PVC, jacketed with abrasion, moisture, gasoline, and oil resistant nylon or listed equivalent, as manufactured by Southwire Company or approved equal. AWM: Conductors shall be UL-listed Type THHN or THWN-2* or MTW or AWM, suitable for operation at 600 volts at conductor temperatures not to exceed 105 C. *rated -2 for 8 AWG and larger only 1 Oil and gasoline resistant ll as defined by Underwriters Laboratories 2 2005 Edition 16

HVAC SIZE (AWG or kcmil) WEIGHTS, MEASUREMENTS AND PACKAGING CONDUCTOR NUMBER OF STRANDS INSULATION THICKNESS (mils) JACKET THICKNESS (mils) NOMINAL O.D. (mils) APPROX. NET WEIGHT PER (lbs/1000 ft) ALLOWABLE AMPACITIES SOL. STR. SOL. STR. 60 C 75 C 90 C STANDARD PACKAGE 14 19 15 4 102 109 15 16 15 15 15 DNFP 12 19 15 4 119 128 23 24 20 20 20 DNFP 10 19 20 4 150 161 37 38 30 30 30 DQFP 8 19 30 5-213 - 62 40 50 55 FP 6 19 30 5-249 - 95 55 65 75 EP Solid construction available in sizes 14 through 10 AWG as Types THHN or THWN or AWM only. Sizes 14 through 6 AWG also suitable for 105 C appliance wiring material (AWM). Sizes 14 and 12 AWG contain four 500 ft. spools per carton. Size 10 AWG contains two 500' spools per carton. Allowable ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition, section 310.15 unless the equipment is marked for use at higher temperatures the conductor ampacity shall be limited to the following: 60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for size 14 through 6 AWG conductors. MTW wet locations or when exposed to oil or coolant. 90 C - THHN dry locations. THWN-2 wet or dry locations. For ampacity derating purpose STANDARD PACKAGE CODES B 1000 ft. reel C 500 ft. reel D 2500 ft. spool E 1000 ft. spool F 500 ft. spool N 2000 ft. carton Q 350 ft. carton P Drum THHN/THWN/TWN75/T90 17

TFFN/TFN/TEWN ANNEALED (SOFT) COPPER HEAT AND MOISTURE RESISTANT POLYVINYL CHLORIDE (PVC) NYLON (POLYAMIDE) JACKET APPLICATIONS Suitable for use as follows: Southwire Type TFFN or MTW or AWM may be used as fixture wire, machine tool wiring, or appliance wiring material as specified in the National Electrical Code 2 When used as Type TFFN, conductor is suitable for use at temperatures not to exceed 90 C When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60 C or dry locations at temperatures not to exceed 90 C (with ampacity limited to that for 75 C conductor temperature per NFPA 79) Conductor temperatures not to exceed 105 C in dry locations when rated AWM and used as appliance wiring material Voltage for all applications is 600 volts STANDARDS & REFERENCES Southwire Type TFFN or MTW or AWM meets or exceeds UL Standard 66 and requirements of the National Electrical Code. CONSTRUCTION Southwire Type TFFN or MTW or AWM copper conductors are annealed (soft) copper, 600 Volt Copper Conductor Thermoplastic Insulation/Nylon Sheath Heat, Moisture, Oil, and Gasoline Resistant 1 Also Rated MTW and 105 C AWM Also Available, TFN insulated with a tough, heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) jacket is applied Available in black, white, red, blue, green, yellow, orange, brown, purple, grey, and pink; some colors standard, some subject to economic order quantity SPECIFICATIONS TFFN: Conductors shall be UL-listed Type TFFN or MTW or AWM gasoline and oil resistant II, suitable for operation at 600 volts as specified in the National Electrical Code. Conductors shall be annealed copper, insulated with high-heat and moisture resistant PVC, jacketed with abrasion, moisture, gasoline, and oil resistant nylon, as manufactured by Southwire Company or approved equal. TFN: Southwire Type TFN conductors may be used as fixture wire and as permitted for fire protective signal circuits as specified in the National Electrical Code at conductor temperatures not to exceed 90 C or 105 C when used as AWM. Voltage rating for all applications is 600 volts. * rated -2 for 8 AWG and larger only 1 Oil and gasoline resistant ll as defined by Underwriters Laboratories 2 2005 Edition 18

HVAC SIZE (AWG) WEIGHTS, MEASUREMENTS AND PACKAGING NUMBER OF STRANDS VINYL THICKNESS (mils) NYLON JACKET (mils) NOMINAL O.D. (mils) APPROX. NET WEIGHT PER (lbs/1000 ft) ALLOWABLE AMPACITIES TFFN MTW STANDARD PACKAGE* 18 16 15 4 85 7 6 7 DNFP 16 26 15 4 99 11 8 10 DNFP *Four 500' spools per carton. Ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition. TFFN as specified by section 402.5 and MTW as specified by NFPA 79. STANDARD PACKAGE CODES F 500 ft. spool N 2000 ft. carton D 2500 ft. spool P Drum TFFN/TFN/TEWN SIZE (AWG) WEIGHTS, MEASUREMENTS AND PACKAGING NUMBER OF STRANDS VINYL THICKNESS (mils) NYLON JACKET (mils) NOMINAL O.D. (mils) APPROX. NET WEIGHT PER (lbs/1000 ft) ALLOWABLE AMPACITIES STANDARD PACKAGE TFN* 18 1 15 4 78 7 6 DNFP 18 7 15 4 82 7 6 DNFP 16 1 15 4 89 10 8 DNFP 16 7 15 4 94 11 8 DNFP *Four 500' spools per carton. Ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition. TFN as specified by section 402.5. STANDARD PACKAGE CODES F 500 ft. spool N 2000 ft. carton D 2500 ft. spool P Drum 19

ROMEX SIMpull TYPE NM-B ANNEALED (SOFT) COPPER NYLON (POLYAMIDE) OR UL-LISTED EQUAL JACKET HEAT AND MOISTURE RESISTANT POLYVINYL CHLORIDE (PVC) PATENT PENDING SIM JACKET CONSTRUCTION APPLICATIONS Suitable for use as follows: Southwire s Romex SIMpull Type NM-B (non-metallic sheathed cable) may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified in the National Electrical Code 1 NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads NM-B cable may be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness Voltage rating for NM-B cable is 600 volts STANDARDS & REFERENCES Southwire s Romex SIMpull Type NM-B cable meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. CONSTRUCTION Non-metallic Sheathed Cable 600 Volt Copper Conductors Color-Coded Jacket SIM Jacket Construction Designed for Easier Pulling Four Conductor Available With Two Neutrals Pulls Faster Southwire s Romex SIMpull Type NM-B cable is manufactured as 2 conductor cable, with a ground wire Copper conductors are annealed (soft) copper Stranded conductors are compressed stranded Conductor insulation is 90 C-rated polyvinyl chloride (PVC), nylon jacketed The cable jacket is color-coded for quick size identification; White - 14 AWG, Yellow - 12 AWG, Orange - 10 AWG, and Black - 8 AWG and 6 AWG Unique SIM (SlikQuik Infused Membrane) Jacket construction allows for 50% reduction in pulling force resulting in easier installation, easier stripping, reduced burn-thru, and tear resistance SPECIFICATIONS Conductors shall be UL-listed Type NM-B, suitable for operation at 600 volts in all installations as specified in the National Electrical Code. Conductors shall be annealed copper as manufactured by Southwire Company or approved equal. 1 2005 Edition Strips Easier Reduced Burn-Thru Tear Resistant 20

HVAC SIZE (AWG) WEIGHTS, MEASUREMENTS AND PACKAGING CONDUCTOR GROUND WIRE APPROX. NUMBER OF NUMBER OF INSULATION CABLE CONDUCTORS STRANDS IN THICKNESS SIZE NUMBER OF DIMENSIONS IN CABLE CONDUCTORS (mils) (AWG) STRANDS (mils) 2 CONDUCTOR APPROX. NET WEIGHT PER (lbs/1000 ft) ALLOWABLE AMPACITIES 14 2 1 19 14 1 360 162 58 15 EH 12 2 1 19 12 1 410 179 83 20 EH 10 2 1 24 10 1 494 210 126 30 EH STANDARD PACKAGE 8 2 7 35 10 1 612 269 187 40 BK 6 2 7 35 10 1 683 304 256 55 BK STANDARD PACKAGE CODES B 1000 ft. reel Ampacity per 310.15 and 334.80, National Electrical Code, 2005 Edition. NOTE: Jacket thickness for all NM-B cable is 30 mils. C 500 ft. reel E 1000 ft. spool H 250 ft. coil K 125 ft. coil ROMEX SIMpull TYPE NM-B 21

QUANTUM TPE TYPE SJEOOW 105 C 300 VOLT UL/CSA TPE PORTABLE CORD BARE COPPER CONDUCTORS POLYPROPYLENE FILLERS TPE CONDUCTORS BLACK TPE JACKET APPLICATIONS Suitable for use as follows: Permitted for use as specified by Article 400 and related articles of the National Electrical Code Some typical applications include wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors, and temporary electrical power and lighting installations for construction sites Suitable for use in (i) dry locations not to exceed minimum -50 C or maximum +105 C; or (ii) wet locations or other applicable locations may be completely immersed in water when exposed to oil or coolant at temperatures not to exceed 60 C Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential STANDARDS & REFERENCES Quantum TPE 105 C TPE Cord 300 Volt Extra Flexible Copper Conductors and Thermoplastic- Elastomer (TPE) Insulation and Jacket Rated -50 C to +105 C Rated as Hard-Usage Service Cord CSA Approved as Type SJTOOW (TPE) at -50 C to +105 C and Meets CSA FT-2 Approved for Outdoor Use Provides Premium Oil Resistance, Water Resistance and Flexibility UL Standard 62 for Flexible Cords CSA Standard 22.2 No. 49 for Flexible Cords Mine Safety and Health Administration (MSHA) Flame Resistance for Mining Applications RoHS Compliant Federal and Military Specification JC-580B NEC Article 400 OSHA CONSTRUCTION Conductors: 18 AWG - 10 AWG fully annealed stranded Class K copper per ASTM B-174 Insulation: Premium-grade, oil-resistant 105 C color-coded TPE Jacket: Premium-grade, oil-resistant Quantum TPE, black Temperature range: -50 C to +105 C Sample Jacket Marking: SOUTHWIRE QUANTUM TPE E46194 12 AWG (3.30 mm 2 ) 3/C SJEOOW (UL) 600V -50 C TO +105 C CSA 224650 SJTOOW (TPE) -50 C TO +105 C FT 2 WATER RESISTANT P-241-3-MSHA MADE IN USA PACKAGING 250' (76.2 m), 500' (152.4 m), 1000' (304.8 m) Some put-ups may be subject to special order 22

HVAC # OF CONDUCTORS WEIGHTS, MEASUREMENTS AND PACKAGING CONDUCTOR SIZE (AWG) COLOR SEQUENCE CONDUCTOR STRANDING (#/AWG) COLOR CODING 2 white, black 3 white, black, green 4 white, black, red, green NOMINAL INSULATION THICKNESS (mils) NOMINAL OVERALL DIAMETER (mils) WEIGHT (lbs/1000 ft) AMPACITY* 18/2 16/30 30 290 44 10 18/3 16/30 30 310 55 10 18/4 16/30 30 335 66 7 16/2 26/30 30 315 54 13 16/3 26/30 30 330 67 13 16/4 26/30 30 360 78 10 14/2 41/30 45 345 68 18 14/3 41/30 45 370 84 18 14/4 41/30 45 400 104 15 12/2 65/30 45 415 97 25 12/3 65/30 45 430 123 25 12/4 65/30 45 475 157 20 10/2 104/30 45 549 166 30 10/3 104/30 45 580 216 30 10/4 104/30 45 640 276 25 *Ampacity values are based on NEC Table 400-5(A) for sizes 18 AWG through 10 AWG. QUANTUM TPE TYPE SJEOOW 105 C 300 VOLT UL/CSA TPE PORTABLE CORD 23

QUANTUM TPE TYPE SEOOW 105 C 600 VOLT UL/CSA TPE PORTABLE CORD BARE COPPER CONDUCTORS POLYPROPYLENE FILLERS TPE CONDUCTORS BLACK TPE JACKET APPLICATIONS Suitable for use as follows: Permitted for use as specified by Article 400 and related articles of the National Electrical Code Typical applications include wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites Suitable for use in (i) dry locations not to exceed minimum -50 C or maximum +105 C; or (ii) wet locations or other applicable locations may be completely immersed in water when exposed to oil or coolant at temperatures not to exceed 60 C Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential STANDARDS & REFERENCES Quantum TPE 105 C TPE Cord 600 Volt Extra Flexible Copper Conductors and Thermoplastic- Elastomer (TPE) Insulation and Jacket Rated -50 C to +105 C Rated as Extra Hard- Usage Service Cord Sizes 18 AWG through 10 AWG CSA Approved as Type STOOW (TPE) and Meet CSA FT-2 Sizes 8 through 2 AWG are Non-UL and Non-CSA Listed Approved for Outdoor Use Provides Premium Oil Resistance, Water Resistance and Flexibility Sizes 18 AWG - 10 AWG: UL Standard 62 for Flexible Cords and CSA Standard 22.2 No. 49 for Flexible Cords Sizes 8 AWG - 2 AWG are non-ul and non-csa Listed, but meet industry-accepted standards for insulation and jacket thickness All sizes meet the Mine Safety and Health Administration (MSHA) Flame Resistance for Mining Applications All sizes are RoHS Compliant All sizes comply with Federal and Military Specification JC-580B NEC Article 400 OSHA CONSTRUCTION Conductors: 18 AWG - 10 AWG fully annealed stranded Class K copper per ASTM B-174 8 AWG - 2 AWG fully annealed stranded copper Insulation: Premium-grade, oil-resistant 105 C color-coded TPE Jacket: Premium-grade, oil-resistant Quantum TPE, black Temperature range: -50 C to +105 C Sample Jacket Marking: SOUTHWIRE QUANTUM TPE E46194 12 AWG (3.30 mm 2 ) 3/C SEOOW (UL) 600V -50 C TO +105 C CSA 224650 STOOW (TPE) -50 C TO +105 C FT 2 WATER RESISTANT P-241-3-MSHA MADE IN USA PACKAGING 250' (76.2 m), 500' (152.4 m), 1000' (304.8 m) Some put-ups may be subject to special order 24

HVAC # OF CONDUCTORS WEIGHTS, MEASUREMENTS AND PACKAGING CONDUCTOR SIZE (AWG) COLOR SEQUENCE CONDUCTOR STRANDING (#/AWG) COLOR CODING 2 white, black 3 white, black, green 4 white, black, red, green 5 white, black, red, orange, green NOMINAL INSULATION THICKNESS (mils) NOMINAL OVERALL DIAMETER (mils) WEIGHT (lbs/1000 ft) AMPACITY* 18/2 16/30 30 345 59 10 18/3 16/30 30 365 69 10 18/4 16/30 30 395 81 7 16/2 26/30 30 370 71 13 16/3 26/30 30 390 81 13 16/4 26/30 30 420 99 10 16/5 26/30 30 495 135 8 14/2 41/30 45 505 126 18 14/3 41/30 45 525 149 18 14/4 41/30 45 575 183 15 14/5 41/30 45 652 219 12 12/2 65/30 45 570 163 25 12/3 65/30 45 595 199 25 12/4 65/30 45 645 242 20 10/2 104/30 45 626 207 30 10/3 104/30 45 665 259 30 10/4 104/30 45 705 316 25 8/2 96/28 60 662 242 40 8/3 96/28 60 701 332 40 8/4 96/28 60 783 425 35 8/5 96/28 60 851 509 28 6/3 96/26 60 818 473 45 6/4 96/26 60 892 594 45 4/3 96/24 60 982 677 70 4/4 96/24 60 1104 886 60 2/3 7/17/0.0223 60 1158 1074 95 2/4 7/17/0.0223 60 1267 1332 80 *Ampacity values are based on NEC Table 400-5(A) for sizes 18 AWG through 10 AWG and Table 400-5(B) for sizes 8 AWG through 2 AWG. QUANTUM TPE TYPE SEOOW 105 C 600 VOLT UL/CSA TPE PORTABLE CORD 25

ULTRATITE TYPE NM LIQUIDTIGHT FLEXIBLE NON-METALLIC CONDUIT APPLICATIONS Suitable for use as follows: For the installation and protection of electrical conductors in circuits of 600 volts nominal, or less Motor circuits - for conductors of motor feeders, branch and control circuits Where the conditions of installation, operation, or maintenance require flexibility or protection from liquids, vapors, solids, or weather Agricultural buildings per NEC 547.5 Used in industrial and commercial applications for conveyors, blowers, cranes, air conditioners, machine tooling and lubrication equipment Exposed or concealed installations Applications requiring movement, crossover connections, or tight bends For direct burial and encased in concrete For flexible connections to swimming pool, spa, and hot tub motors per NEC 680.21(A)(3) & 680.42(A)(1) Electric signs and outline lighting supply and secondary-circuit conductors per NEC 600.7, 600.31 (1000 volts or less) & 600.32 (over 1000 volts) Hazardous Locations - see Additional Applications Section on the following page for more details Liquidtight Flexible Non-Metallic Conduit UL/CSA Listed Oil-Resistant Sunlight-Resistant Crush-Resistant Temperature Rated -30 C to +80 C STANDARDS & REFERENCES NEC Type designation - Type LFNC-B (Liquidtight Flexible Non-Metallic Conduit) ANSI / NFPA-70, NEC Article 356 UL Listed to Underwriters Laboratories Standard UL 1660 Approved by Canadian Standards Association CONSTRUCTION Ultratite Type NM is manufactured with a spiral of rigid PVC reinforcement imbedded within a flexible PVC wall. The construction provides excellent impact and crush strength while remaining highly flexible. The conduit resists oils, mild acids and exposure to sunlight. FEATURES A protective combination of thermoplastic materials formed into a conduit/raceway which seals out water, liquids, abrasives, alcohol, coolants, corrosive fumes and gases, dirt, grease, mineral acids, non-concentrated fixed alkalines, petroleum oils, salt air and spray, and weather Smooth interior for easy wire pulling UV sunlight-resistant jacket Rated for temperature range of -30 C to +80 C, 60 C Oil (-22 F to +176 F, 140 F Oil) Accepts standard Liquidtight fittings for use with LFNC-B 26

HVAC WEIGHTS, MEASUREMENTS AND PACKAGING TRADE SIZE (inches) APPROX. WEIGHT (lbs/100 ft) INNER DIAMETER MIN./MAX. (inches) OUTER DIAMETER MIN./MAX. (inches) ADDITIONAL APPLICATIONS MINIMUM BENDING RADIUS (inches) Hazardous Locations - where necessary for flexible connections within hazardous locations per the following: - Class 1, Div. 2-2005 NEC 501.10(B)(2) - Class 2, Div. 1-2005 NEC 502.10(A)(2) - Class 2, Div. 2-2005 NEC 502.10(B)(2) - Class 3, Div. 1-2005 NEC 503.10(A)(2) - Class 3, Div. 2-2005 NEC 503.10(B) Floating building feeders and services per NEC 553.7 Boatyards and Marinas in accordance with NEC 555.13 Cranes and Hoists in accordance with NEC 610.11(C) For Elevator, Dumbwaiters, Escalators, Moving Walks, Wheel Chair Lifts and Stairway Chair Lifts in accordance with NEC 620.21 (where expressly permitted) Under raised floors in information technology equipment conductors and cables in accordance with NEC 645.5(D) & 645.5(D)(2) Service entrance in lengths up to six feet per NEC 230.43(15) For containment of 600 Volt and lower potential circuits Approved for use in lengths longer than 6 feet per NEC 356.10(5) Motor leads per NEC 430.145(B) STANDARD COIL LENGTH (feet) STANDARD REEL LENGTH (feet) 3/8 10.5 0.484 0.504 0.690 0.710 4 100 600 1/2 13 0.622 0.642 0.820 0.840 4 100 1000 3/4 18 0.820 0.840 1.030 1.050 5 100 1000 ULTRATITE TYPE NM LIQUIDTIGHT FLEXIBLE NON-METALLIC CONDUIT 27

ARMORLITE TYPE MC COPPER TYPE THHN/THWN BINDER TAPE LIGHTWEIGHT ALUMINUM INTERLOCKED ARMOR APPLICATIONS Suitable for use as follows: Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings Power, lighting, control, and signal circuits Fished or embedded in plaster Concealed or exposed installations Environmental air-handling spaces per NEC 300.22(C) Places of Assembly per NEC 518.4 and theaters per NEC 520.5 As aerial cable on a messenger Installation in cable tray and approved raceways Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2) Class I Div. 2, Class II Div. 2, & Class III Div. 1 Hazardous Locations STANDARDS & REFERENCES Lightweight Aluminum Interlocked Armor 600 Volt Copper Power Conductors THHN/THWN Insulated Singles Green Insulated Grounding Conductor Sizes 14 AWG through 2 AWG Rated VW-1 Southwire Armorlite Type MC Cable meets or exceeds the requirements of UL Standard 83, UL Standard 1063, UL Standard 1569 for Type MC, Federal Specification A-A59544 (formerly J-C-30B), IEEE 1202 (70,000 BTU/hr) Vertical Cable Tray Flame Test, and the National Electrical Code Southwire Armorlite Type MC Cable is listed for use in UL 1, 2, and 3 Hour Through- Penetration Firestop Systems CONSTRUCTION Southwire Armorlite Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90 C dry/ 75 C wet, available in sizes 14 AWG through 750 kcmil, and a green insulated grounding conductor (sizes 1/0 AWG and larger furnished with bare grounding conductor) The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly Aluminum interlocked armor is applied over the assembly. Refer to color chart for conductor color sequence FEATURES Reduces installation costs up to 50% over pipe and wire Lightweight aluminum armor as much as 45% lighter than steel MC Cable UL Classified 1, 2, and 3 Hour Through-Penetration Firestop Systems: W-J-3037, W-L- 3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038 Cable reverse wound on reel for ease of pulling and installation; when pulling from coils, pull from inside to ensure ease of installation 1 2005 Edition 28

HVAC CONDUCTOR SIZE* (AWG) WEIGHTS, MEASUREMENTS AND PACKAGING CONDUCTOR TYPE GROUNDING CONDUCTOR SIZE (AWG)** OVERALL DIAMETER (inches) WEIGHT (lbs/1000 ft) ALLOWABLE AMPACITIES STANDARD PACKAGE 60 C 75 C 90 C COIL (feet) REEL (feet) 14/2 Solid 14 0.439 78 15 15 15 250 1000 14/3 Solid 14 0.464 96 15 15 15 250 1000 14/4 Solid 14 0.494 114 15 15 15 250 1000 12/2 Stranded 12 0.494 110 20 20 20 250 1000 12/2 Solid 12 0.475 105 20 20 20 250 1000 12/3 Stranded 12 0.527 137 20 20 20 250 1000 12/3 Solid 12 0.505 131 20 20 20 250 1000 ARMORLITE TYPE MC Note: Ampacities are based on Table 310.16 of the NEC, 2005 Edition. Allowable ampacities shown are for general use as specified by the National Electrical Code, 2005 Edition, Section 310.15. If the equipment is marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C): 60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for size 14 through 1 AWG conductors. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C - For ampacity derating purposes. Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of 0.80 when the neutral is considered a current-carrying conductor. *Available in sizes up to 750 kcmil. **All grounding conductors 8 AWG and larger will be stranded. # OF CONDUCTORS COLOR SEQUENCE 2 white, black COLOR CODING 120/208Y 3 white, black, red 4 white, black, red, blue Grounding Conductor green Other special colors are available subject to economic order quantity. # OF CONDUCTORS 2 brown, grey 2 orange, grey COLOR SEQUENCE 2 yellow, grey 2 purple, grey COLOR CODING 277/480Y 3 brown, yellow, grey 3 brown, orange, grey 4 brown, orange, yellow, grey 4 brown, yellow, purple, grey Grounding Conductor green 29

COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E RISER RATED - CMR APPLICATIONS Suitable for use as follows: 1000 base-t (Gigabit Ethernet); 100 base-t (Fast Ethernet); 10 base-t (IEEE 802.3); 4/16 Mbps token ring (IEEE 802.5); 100 VG-Any LAN; 100 Mbps TP-PMD (ANSI X3T9.5); 55/155 Mbps ATM; voice, ISDN, video to desktop, multimedia STANDARDS & REFERENCES ETL verified ANSI TIA/EIA-568B.2, UL subject 444, (UL) c(ul) type CMR/CMG, type CM/CMH, ICEA-S-90-661, NEC article 800 type CMR or CM, ISO/TEC 11801 CONSTRUCTION 24 AWG solid bare copper, 4 unshielded twisted pairs, FRPE insulation, rip cord, FRPVC jacket, operating temperature 75 C, 300 volts Sample Jacket Marking: E118871 (T) 4PR 24AWG CMR (UL) c(ul) 75C CSA CMG ETL VERIFIED TO ANSI TIA/EIA-568-B.2 CATEGORY 5E 350 MHZ. SEQUENTIAL FOOTAGE MARKING PACKAGE Rated 300 Volt Operating Temperature 75 C Available in 1000 ft. boxes or reels. Reel-in-a-box upon request. Jacket colors other than listed below, consult factory. Color code (Orange & White/Orange, Green & White/Green, Blue & White/Blue, Brown & White/Brown) FRPE Insulation Rip Cord FRPVC Jacket 30

HVAC AWG FREQUENCY (MHz) NO PAIRS WEIGHTS, MEASUREMENTS AND PACKAGING ATTENUATION (db/100m) NEXT (db) IMP. (OHMS) ACR (db) CABLE TYPE PSNEXT (db) NOMINAL OD PSACR (db) LBS/MFT 24 4 100 ± 15 UTP.200 22 Jacket Color,.X 1 = gray, 3 = blue, 4 = white, 5 = yellow, 7 = red, 9 = green ELFEXT (db) PS.ELFEXT (db) RETURN LOSS (db) CHARACTERISTIC IMPEDANCE 1-350 MHz (OHM S) 1 2 74.3 72.3 72.3 70.3 67.8 64.8 20 100 ± 15 4 3.8 65.5 61.5 63.3 59.5 55.7 52.7 23 100 ± 15 8 5.4 60.8 55.4 58.8 53.4 49.7 46.7 24.5 100 ± 15 10 6 59.3 53.3 57.3 51.3 47.8 44.8 25 100 ± 15 16 7.6 56.3 48.7 54.3 46.7 43.7 40.7 25 100 ± 15 20 8.5 54.8 46.3 52.8 44.3 41.7 38.7 25 100 ± 15 25 9.6 53.3 43.7 51.3 41.7 39.8 36.8 24.3 100 ± 15 31.25 10.7 51 41.2 49.9 39.2 37.9 34.9 23.6 100 ± 15 62.5 15.5 47.4 31.9 45.1 29.9 31.8 28.8 21.5 100 ± 15 100 19.9 44.3 24.4 42.3 22.4 27.8 24.8 20.1 100 ± 15 155 25.3 41.5 16.2 39.5 14.2 23.9 20.9 18.8 100 ± 15 200 29.2 39.8 10.6 37.8 8.6 21.7 18.7 18 100 ± 15 240 36 32.6-30.6-16.2 13.2 17.4 100 ± 15 300 41 31.2-29.2-14.2 11.2 16.8 100 ± 15 350 44.9 30.1-28.1-12.9 9.9 16.3 100 ± 15 COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E RISER RATED - CMR 31

COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E PLENUM RATED - CMP APPLICATIONS Suitable for use as follows: 1000 base-t (Gigabit Ethernet); 100 base-t (Fast Ethernet); 10 base-t (IEEE 802.3); 4/16 Mbps token ring (IEEE 802.5); 100 VG-Any LAN; 100 Mbps TP-PMD (ANSI X3T9.5); 55/155 Mbps ATM; voice, ISDN, video to desktop, multimedia STANDARDS & REFERENCES ETL verified ANSI TIA/EIA-568B.2, Category 5e, ISO/IEC 11801 Ed 2.0. (Class D) Approved for plenum use without conduit per NEC Article 800 by passing UL-910 Steiner Tunnel test and CSA CMP UL Listed CMP c(ul) CONSTRUCTION 24 AWG solid bare copper, 4 unshielded twisted pairs, FEP insulation, rip cord, FRPVC jacket, operating temperature 75 C, 300 volts Sample Jacket Marking: E118871 4PR 24AWG CMP (UL) c(ul) ETL VERIFIED TO ANSI TIA/EIA-568-B.2 Category 5E 350 MHZ. Sequential footage markings 300 Volt Operating Temperature 75 C PACKAGE Available in 1000 ft. boxes or reels. Reel-in-a-box upon request. Jacket colors other than listed below, consult factory. Color code (Orange & White/Orange, Green & White/Green, Blue & White/Blue, Brown & White/Brown) FEP Insulation Rip Cord FRPVC Jacket 32

HVAC AWG FREQUENCY (MHz) NO PAIRS WEIGHTS, MEASUREMENTS AND PACKAGING ATTENUATION (db/100m) NEXT (db) IMP. (OHMS) ACR (db) CABLE TYPE PSNEXT (db) NOMINAL OD PSACR (db) LBS/MFT 24 4 100 ± 15 UTP.190 24 Jacket Color,.X 1 = white, 2 = blue, 3 = gray, 4 = red, 5 = yellow, 6 = green ELFEXT (db) PS.ELFEXT (db) RETURN LOSS (db) CHARACTERISTIC IMPEDANCE 1-350 MHz (OHM S) 1 2 74.3 72.3 72.3 70.3 67.8 64.8 20 100 ± 15 4 3.8 65.5 61.5 63.3 59.5 55.7 52.7 23 100 ± 15 8 5.4 60.8 55.4 58.8 53.4 49.7 46.7 24.5 100 ± 15 10 6 59.3 53.3 57.3 51.3 47.8 44.8 25 100 ± 15 16 7.6 56.3 48.7 54.3 46.7 43.7 40.7 25 100 ± 15 20 8.5 54.8 46.3 52.8 44.3 41.7 38.7 25 100 ± 15 25 9.6 53.3 43.7 51.3 41.7 39.8 36.8 24.3 100 ± 15 31.25 10.7 51 41.2 49.9 39.2 37.9 34.9 23.6 100 ± 15 62.5 15.5 47.4 31.9 45.1 29.9 31.8 28.8 21.5 100 ± 15 100 19.9 44.3 24.4 42.3 22.4 27.8 24.8 20.1 100 ± 15 155 25.3 41.5 16.2 39.5 14.2 23.9 20.9 18.8 100 ± 15 200 29.2 39.8 10.6 37.8 8.6 21.7 18.7 18 100 ± 15 240 36 32.6-30.6-16.2 13.2 17.4 100 ± 15 300 41 31.2-29.2-14.2 11.2 16.8 100 ± 15 350 44.9 30.1-28.1-12.9 9.9 16.3 100 ± 15 COMMUNICATION CIRCUITS ENHANCED CATEGORY 5E PLENUM RATED - CMP 33

TEMPERATURE CONTROL CABLES PLENUM AND NON-PLENUM RATED APPLICATIONS Building automation systems Commercial Controls Network and Automation Control Systems INDUSTRY APPROVALS NEC Article 725 Type CL3 or CL3P (UL: 75 C, 150 V) NEC Article 800 Type CM or CMP (UL: 75 C, 300 V) CONSTRUCTION CL3, CL3P - 150 V CM, CMP - 300 V Operating Temperature + 75 C Premium Grade Insulation Aluminum Foil or Foil Plus TC Braid PVC, LS-PVC or FEP Jacket Conductor: Stranded or solid copper Insulation: Premium grade color suitable for application Non-Plenum - PVC, PP, PE or FPE Plenum - LS-PVC, FEP or FOM FEP Shield: Overall aluminum foil or foil plus tinned copper braid Jacket: PVC, LS-PVC or FEP Sequential footage marking to facilitate installation Suitable for use from 0 C to + 75 C Ripcord available 34

HVAC WEIGHTS AND MEASUREMENTS NON-PLENUM CABLES APPLICATION CONSTRUCTION SHIELD JACKET COLOR NOM. CAP. NOM. IMP O.D. INCHES WEIGHT (lbs) CANopen 1 pr 24 1 pr 24 TC 120 Ohm CM Foil + Br Gray 12.5 120 0.236 34.4 lbs. CANopen 2 pr 24 2 pr 24 TC 120 Ohm CM Foil + Br Gray 12.5 120 0.353 58.0 lbs. CANopen 1 pr 22 1 pr 22 TC 120 Ohm PLTC Foil + Br Black 10.6 120 0.286 50.0 lbs. CANopen 2 pr 22 2 pr 22 TC 120 Ohm PLTC Foil + Br Black 10.6 120 0.403 80.0 lbs. LonWorks Office Gr. Cat 5e 4 pr 24 BC CMR N/S Blue* 15.0 100 0.200 22.0 lbs. LonWorks 1 pr L4 NS 1 pr 22 BC CM N/S Gray* 15.0 100 0.146 11.0 lbs. LonWorks 2 pr L4 NS 2 pr 22 BC CM N/S Gray 12.5 120 0.226 20.0 lbs. LonWorks 1 pr L4 shld 1 pr 22 BC CM Foil Gray* 12.9 100 0.226 22.0 lbs. LonWorks 2 pr L4 shld 2 pr 22 BC CM Foil Gray 12.9 100 0.261 25.0 lbs. LonWorks Std. N/S 2 C 16 TC AWM 2598 CMR N/S Gray 33.0 70 0.266 39.0 lbs. LonWorks Std. Shld 2 C 16 TC AWM 20253 CM Foil Gray 19.5 80 0.298 48.0 lbs. BACNet Microset II 1 triad 22 TC AWM 2093 CM Foil Gray 19.5 80 0.198 24.0 lbs. TRANE systems 2C 18 TC AWM 2092 CM Foil Gray 25.0 65 0.218 28.0 lbs. Aerial / Burial Non-UL 2C 18 TC (non UL) Foil Black 25.0 65 0.234 27.0 lbs. *Other jacket colors also available. Jacket color may vary for specific system type per application. PLENUM CABLES APPLICATION CONSTRUCTION SHIELD JACKET COLOR NOM. CAP. NOM. IMP O.D. INCHES WEIGHT (lbs) CANopen 1 pr 24 1 pr 24 120 Ohm CMP Foil + Br White 11.0 120 0.174 24.0 CANopen 2 pr 24 2 pr 24 120 Ohm CMP Foil + Br White 11.0 120 0.208 34.0 LonWorks Office Gr. Cat 5e 4 pr 24 CMP N/S White* 15.0 100 0.190 24.0 LonWorks 1 pr L4 NS 1 pr 22 CMP N/S White* 15.0 100 0.122 10.0 LonWorks 2 pr L4 NS 2 pr 22 CMP N/S White* 15.0 100 0.179 17.0 LonWorks 1 pr L4 shld 1 pr 22 CMP Foil White* 12.2 100 0.162 15.0 LonWorks 2 pr L4 shld 2 pr 22 CMP Foil White* 12.2 100 0.263 24.0 LonWorks Std. N/S 2C 16 FEP/FEP CMP N/S Clear 25.0 60 0.170 27.0 BACNet applications 1 pr 22 TC CMP Foil White* 40.0 47 0.118 11.0 ARC 156 1 pr 22 TC CMP Foil Green 15.0 100 0.146 14.0 TRANE systems 2C 18 TC CMP Foil Purple 25.0 60 0.178 24.0 U-LINE PLENUM 1 pr shld 22 TC shld Foil (1pr) 14.1 87 White + 2C 14 BC N/S CL3P N/S 32.9 56 0.393 55.0 TCS Basys Plenum 1 triad 20 BC Shld Foil (1tr) 44.0 42 White + 2C 18 BC N/S CMP N/S 47.0 40 0.318 36.5 *Other jacket colors also available. Jacket color may vary for specific system type per application. TEMPERATURE CONTROL CABLES PLENUM AND NON-PLENUM RATED 35