Pendant control stations 6

Similar documents
Pendant control stations 6

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Pendant control stations 6

Control stations and enclosures 0

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

Components for safety applications

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Characteristics 5 TeSys k contactors and reversing contactors

Modular equipment. Presentation, standards. Standard contactors TeSys GC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Electromechanical pressure and vacuum switches 0

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

Complete units: Push-buttons ø 22mm

Complete units: Mushroom heads ø 22mm

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Control Stations ø 22

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

3 - Protection components Circuit-breakers

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Operator Heads: ø 22mm

Complete units: Selector switches ø 22mm

Operator Heads: ø 22mm

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Separate units: Blocks

Safety switches with slotted hole lever

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

FM series position switches

Local control stations for Zone 1 and Zone 21. Features. Description

Motor starters. TeSys E. Designed for the essential

Position switches FM series

LR Position Switches TECHNICAL DATASHEET

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Charlie. Pendant control station. Industrial lifting. Construction lifting. Stage technology. Industrial automation

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Controls Contactors and Contactor Assemblies Special Applications

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

Wireless and batteryless pushbuttons

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

Protection components

DISCONNECT SWITCHES. UL Listed CSA Certified

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

Protection components

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Type CP-S, CP-C & CP-A Switch mode

Control module CP-A CM

Components for safety applications Preventa safety modules

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

NS..S contactor relays - with spring terminals AC operated

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Increased safety - Group IIC XAWP series. Glass-reinforced polyester (GRP) -20 C C INERIS03ATEX0122X

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

Snap Action Switches Technical Guide

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Harmony Double and Triple- Headed Push Buttons. Catalog

Electronic timer CT-SDS.22

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

RE17LLBM asymmetrical flashing relay s V AC - solid state output

Three-phase monitoring relay CM-PFS

Detecting Devices. 8/2 Introduction

Actuators Series 8602/3

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

References 1 for asynchronous motors 1

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Safety detection solutions Preventa

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Wireless, Batteryless Push Buttons

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

Accessories. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

02/11/2015

Specifications. Safety Ratings. Standards. Safety Classification

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

02/11/2015

Electronic timer CT-TGD.22

Custom "Compact" range with display CD20 Custom Part number

Electronic timer CT-SDD.22

Transcription:

Characteristics 6 For control circuits Environment Conformity to standards EN/IEC 6097-5-1, CSA C22-2 n Product certifications XAC B Standard version: CSA 300 V type XAC M Standard version: CSA 300 V type Protective treatment XAC B Standard version: TH XAC M Standard version: TC, ( TH on request) Ambient air temperature For storage C - 0 + 70 For operation C - 25 + 70 Vibration resistance 15 gn (10 500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Electric shock protection XAC B Class II XAC M Class I conforming to IEC 610 Degree of protection IP 65 conforming to IEC 60529; IK 08 conforming to IEC 50102 Mechanical durability 1 (in millions of operating cycles) Enclosure XAC B Double insulated glass-reinforced polyester (colour: yellow) XAC M Aluminium enclosure. Painted yellow Cable entry Rubber sleeve with stepped entry diameter for cable Ø 7 mm, Ø 10 22 mm or Ø 22 35 mm Contact block characteristics Rated operational characteristics a AC-15: A300 or Ue = 0 V, le = 3 A c DC-: Q300 or Ue = 250 V, le = 0.27 A conforming to EN/IEC 6097-5-1 Appendix A Thermal current (lthe) A 10 Rated insulation voltage (Ui) XEN Cpppp, XEN D3ppp, V 500, degree of pollution 3, conforming to EN/IEC 6097-1 XEN Dppp, XES B20, XAC S, XES D81, XES D81 XEN Bpppp, XEN D1ppp, XEN D2ppp 00, degree of pollution 3, conforming to EN/IEC 6097-1 Rated impulse withstand voltage (U imp) kv 6, conforming to EN/IEC 6097-1 Positive operation Contact operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 6097-5-1 Appendix K Slow break or snap action Resistance across terminals MΩ y 25 Operating force With booted operator N XAC Sppp: 10 (N/O), 8 (N/C); XEN Cpppp: 6 (N/O), (N/C); XEN Bpppp, XEN D1ppp, XEN D2ppp: Single-speed: 9; 2-speed: 20 (1 st speed), 30 (2 nd speed); XEN D3ppp, XEN Dppp: 25; XES B20: 7; XES D81, XES D8: 15 (1 st speed), 25 (2 nd speed) With spring return mushroom head operator N 10 With latching mushroom head N 0 operator Terminal referencing By numbers conforming to EN 500 Short-circuit protection 10 A cartridge fuse type gg (gl) Connection mm 2 Screw and captive cable clamp terminals. Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Operational power conforming to EN/IEC 6097-5-1 Appendix C Utilisation categories AC-15 and DC- For 1 million operating cycles Operating rate: 3600 operating cycles/hour Load factor: 0.5 o Inductive circuit Contact blocks XEN Cpppp, XEN D3ppp, XEN Dppp, XAC Sppp a.c. supply a 50/60 Hz d.c. supply c Voltage V 8 7 0 Voltage V 8 0 o VA 0 385 525 55 o W 60 5 2 Contact blocks XEN Bpppp, XEN D1ppp, XEN D2ppp a.c. supply a 50/60 Hz d.c. supply c Voltage V 8 7 0 Voltage V 8 0 o VA 0 210 60 680 o W 8 31 35 References: page 30076/3 Dimensions: page 30076/ Contact blocks XES B20, XES D81, XES D81 a.c. supply a 50/60 Hz d.c. supply c Voltage V 8 7 0 Voltage V 8 0 o VA 50 100 50 750 o W 0 0 95 Application schemes: page 30076/ 2 version: 9.3 30076-EN.indd

References 6 For control circuits Complete stations ready for use (with snap action contact blocks) DF56556 DF565565 For control of single-speed motors Functions Number of operators 2 without mechanical interlocking Contact blocks and scheme Reference Weight Per direction 1 C/O snap action XAC B281 0.850 XES B20 2 1 3 XAC B281 without mechanical interlocking 1 C/O snap action XES B20 2 1 3 XAC B81 1.100 DF565566 XAC B81 6 without mechanical interlocking 1 C/O snap action XES B20 2 1 3 XAC B681 1.300 DF565567 XAC B681 I 8 without mechanical interlocking 1 C/O snap action XES B20 2 1 3 XAC B881 1.550 O XAC B881 30076-EN.indd version: 9.3 3

Characteristics 6 For power circuits (direct switching) Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 6020-32, UL 508, CSA C22-2 n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop EN/IEC 6097-3 Product certifications Standard version CSA type Protective treatment Standard version TH Ambient air temperature For storage C - 0 + 70 For operation C - 25 + 70 Vibration resistance 15 gn (10 500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Electric shock protection Class II conforming to IEC 610 Degree of protection IP 65 conforming to IEC 60529 Mechanical durability (in millions of operating cycles) Enclosure Cable entry 1 except for XAC B91p and XAC CB92p: 0. Double insulated glass-reinforced polyester (colour: yellow) Rubber sleeve with stepped entry diameter for cable Ø 10 Ø 22 mm Contact block characteristics Thermal current (lthe) XES D91, XES D91 A XES D2201, XES D21, A 20 XES D2251 Rated insulation voltage (Ui) XES Dpppp V 500, degree of pollution 3, conforming to IEC 6097-1 XAC Sp99 V 00, degree of pollution 3, conforming to IEC 6097-1 XES D1ppp V 600, conforming to CSA XES D2ppp V 300, conforming to CSA Rated impulse withstand voltage (U imp) kv 6, conforming to IEC 6097-1 Contact operation Snap action Operating force XES D1ppp N 17 XES D2ppp N 32 Terminal referencing By numbers conforming to CENELEC EN 50005 Short-circuit protection XES D1ppp 10 A maximum cartridge fuse type am XES D2ppp A maximum cartridge fuse type am Connection mm 2 Captive screw clamp terminals Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Operational power 3 phases, 2 poles Utilisation categories AC-3 and AC- conforming to EN/IEC 6097-3 Appendix A XES D1ppp 2.2 kw-0 V 2.2 kw-00 V Mechanical durability (in millions of operating cycles) Utilisation categories AC-3 and AC- conforming to EN/IEC 6097-3 Appendix A Duty cycle comprising 75% AC-3, 25% AC- Operating rate: 600 operating cycles per hour Load factor: 0. 3 phases, 3 poles XES D2ppp 3 phases, 3 poles, isolating block XAC Sp99 3 kw-0 V 3 kw-00 V Utilisation category AC-B 3 kw-00 V 3 phases, 2 poles CSA certifi cation XES D1ppp 2 hp-0 V 5 hp-00 V 3 hp-600 V 3 phases, 3 poles XES D2ppp 3 hp-0 V 3 phases, 2 poles XES D1ppp 1.5 kw-0 V = 0.5 2.2 kw-0 V = 0.3 1.5 kw-00 V = 0.8 2.2 kw-00 V = 0.3 3 phases, 3 poles XES D2ppp 3 kw-0 V = 0.7 3 kw-00 V = 1 References: page 30076/5 Dimensions: page 30076/ Application schemes: page 30076/25 version: 9.3 30076-EN.indd

References 6 For power circuits (direct switching) Complete stations ready for use DF565568 DF565569 For control of single-speed motors Functions Number of operators 2 mechanically interlocked Contact blocks Per direction 2-pole XES D91(1) For Emergency stop Maximum operational power/00 V Reference Weight 2.2 kw XAC B219 0.355 XAC B219 XAC B220 XAC B3195 XAC B3205 3-pole XES D2201(1) 3 kw XAC B220 0.355 DF565570 DF565571 2 mechanically interlocked + 1 trigger action latching Emergency stop Ø 0 mm operator ZA2 BS8 2-pole XES D91(1) 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S99 1 N/C + N/C + N/C XAC S99 2.2 kw XAC B3195 r 0.90 3 kw XAC B3205 r 1.000 mechanically interlocked between pairs 2-pole XES D91(1) 2.2 kw XAC B91 1.200 3-pole XES D2201(1) 3 kw XAC B93 1.0 DF565572 XAC B91 XAC B93 XAC B916 XAC B936 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 0 mm operator ZA2 BS8 2-pole XES D91(1) 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S99 1 N/C + N/C + N/C XAC S99 2.2 kw XAC B916 r 1.260 3 kw XAC B936 r 1.390 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 0 mm operator ZA2 BS8 mounted in base 2-pole XES D91(1) 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S3991 1 N/C + N/C + N/C XAC S3991 2.2 kw XAC B915 r 1.350 3 kw XAC B935 r 1.80 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 6020-32, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC 6097-5-5. XAC B915 XAC B935 r Available 3 rd quarter of 20 30076-EN.indd version: 9.3 5

References (continued) 6 For power circuits (direct switching) Complete stations ready for use DF565573 For control of single-speed motors (continued) Functions Number of operators 6 mechanically interlocked between pairs Contact blocks Per direction 2-pole XES D91(1) For Emergency stop Maximum operational power/00 V Reference Weight 2.2 kw XAC B691 1.350 3-pole XES D2201(1) 3 kw XAC B693 1.550 6 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 0 mm operator ZA2 BS8 2-pole XES D91(1) 3-pole XES D2201(1) 1 N/C + N/C + N/C XAC S99 1 N/C + N/C + N/C XAC S99 2.2 kw XAC B6916 r 1.10 3 kw XAC B6936 r 1.610 DF56557 XAC B691 XAC B693 DF565575 6 mechanically interlocked between pairs + 1 trigger action latching Emergency stop Ø 0 mm operator ZA2 BS8 mounted in base 2-pole XES D91(1) 3-pole XES D2201(1) For control of 2-speed motors Functions Number of operators 2 mechanically interlocked Contact blocks Per direction 2-pole XES D91(1) 1 N/C + N/C + N/C XAC S3991 1 N/C + N/C + N/C XAC S3991 For Emergency stop 2.2 kw XAC B6915 r 1.500 3 kw XAC B6935 r 1.700 Maximum operational power/00 V Reference Weight 2.2 kw XAC B229 0.05 DF565576 XAC B6916 XAC B6936 DF565577 XAC B6915 XAC B6935 2 mechanically interlocked + 1 trigger action latching Emergency stop Ø 0 mm operator ZA2 BS8 2-pole XES D91(1) 1 N/C + N/C + N/C XAC S99 2.2 kw XAC B3295 r 0.990 (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 6020-32, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC 6097-5-5. XAC B229 XAC B3295 r Available 3 rd quarter of 20 Characteristics: page 30076/ Dimensions: page 30076/ Application schemes: page 30076/25 6 version: 9.3 30076-EN.indd

References 6 Empty enclosures DF565578 DF565579 Empty enclosures for control circuits or power circuits (1) Description Protective cable sleeve Empty enclosures (1) For cable Double insulated for Ø 7 mm Small hoist applications Operator cut-out centres: 0 mm Number of cut-outs Cut-out in base of enclosure Reference Weight 2 Without XAC B020 0.760 3 Without XAC B030 0.760 XAC B020 XAC B030 DF565580 DF565581 Empty enclosures (1) Double insulated for General purpose applications Operator cut-out centres: 0 mm For cable Ø 10 22 mm 2 Without XAC B02 0.760 With XAC B021 0.760 Without XAC B0 1.000 XAC B02p XAC B0p With XAC B01 1.000 DF565582 DF565583 6 Without XAC B06 1.160 With XAC B061 1.160 8 Without XAC B08 1.0 XAC B06p With XAC B081 1.0 DF56558 in 2 rows of 6 Without XAC B 1.60 XAC B08p With XAC B1 1.60 (1) Enclosure comprising: - the enclosure, - protective cable sleeve, - cable tie (for tightening sleeve onto cable), - internal cable clamp, - suspension ring, - bezel tightening key. XAC Bp 30076-EN.indd version: 9.3 7

References (continued) 6 Empty enclosures DF565580 DF565581 Empty enclosures for control circuits or power circuits (1) (continued) Description Empty enclosures (1) Double insulated for General purpose applications Operator cut-out centres: 0 mm Protective cable sleeve For cable Ø 22 35 mm Number of cut-outs Cut-out in base of enclosure Reference Weight 2 Without XAC B025 0.960 With XAC B0215 0.960 Without XAC B05 1.200 XAC B02pp XAC B0pp With XAC B015 1.200 DF565582 DF565583 6 Without XAC B065 1.360 With XAC B0615 1.360 8 Without XAC B085 1.530 XAC B06pp With XAC B0815 1.530 DF56558 in 2 rows of 6 Without XAC B5 1.660 XAC B08pp With XAC B15 1.660 (1) Enclosure comprising: - the enclosure, - protective cable sleeve, - cable tie (for tightening sleeve onto cable), - internal cable clamp, - suspension ring, - bezel tightening key. XAC Bpp Characteristics: pages 30076/2 and 30076/ Dimensions: page 30076/ Application schemes: page 30076/ Presentation: page 30076/26 8 version: 9.3 30076-EN.indd

References 6 For control circuits Empty enclosures (XAC M: products for maintenance purposes only) DF565585 Empty enclosures for control circuits (1) Description Empty enclosures (1) Double insulated for General purpose applications Operator cut-out centres: 30 mm Protective cable sleeve For cable Ø 10 22 mm Number of cut-outs Cut-out in base of enclosure Reference Weight in 1 row Without XAC B0 1.0 With XAC B01 1.0 For cable Ø 22 35 mm in 1 row Without XAC B05 1.530 With XAC B015 1.530 XAC B0 Empty enclosures (1) Metal for General purpose applications Operator cut-out centres: 0 mm For cable Ø 10 22 mm Without XAC M0 1.50 With XAC M01 1.50 DF565587 8 Without XAC M08 2.210 DF565586 With XAC M081 2.210 For cable Ø 22 35 mm Without XAC M05 1.70 With XAC M015 1.70 8 Without XAC M085 2.10 XAC M0p XAC M08p With XAC M0815 2.10 Variable composition stations, factory assembled Use the order form on page 30076-EN/27 to defi ne the required confi guration Equipment: contact blocks, operating heads (control and signalling), complementary accessories See separate components, pages 30076/10 to 30076/22 (1) Enclosure comprising: - the enclosure, - protective cable sleeve for cable Ø 10 22 mm or Ø 22 35 mm, - cable tie (for tightening sleeve onto cable), - internal cable clamp, - suspension ring, - bezel tightening key. 30076-EN.indd version: 9.3 9

References 6 For control circuits Separate components and spare parts DF565588 Contact blocks for front mounting, slow break Description Application Function Scheme Operator centres Spring return Single block 1 spring return operator mm Reference Weight Single-speed N/O 30 or 0 XEN C 0.020 XEN C N/C 30 or 0 XEN C21 0.020 N/O + N/O 30 or 0 XEN C 0.020 N/C + N/C 30 or 0 XEN C 0.020 21 22 N/C + N/O 30 or 0 XEN C51 0.020 DF565589 C/O + N/O 30 or 0 XEN B91 0.050 32 31 XEN B81 2-speed 2 step N/O + N/O staggered 3 30 or 0 XEN B81 0.050 2 step C/O + N/O staggered 32 31 30 or 0 XEN B91 0.050 DF565590 Double block 2 spring return operators mechanically interlocked Single-speed N/O + N/O simultaneous 30 XEN D16 0.0 0 (1) XEN D26 0.0 3 XEN D26 2-speed 2 step N/O + N/O staggered 30 XEN D1621 0.0 0 (1) XEN D2621 0.0 3 (1) These contact blocks cannot be mounted in enclosures XAC B0p ( operators in 1 row). Characteristics: pages 30076/2 and 30076/ Dimensions: page 30076/ Application schemes: page 30076/ Presentation: page 30076/26 10 version: 9.3 30076-EN.indd

References (continued) 6 For control circuits Separate components and spare parts DF565593 Contact blocks for front mounting, slow break (continued) Description Application Function Scheme Operator Reference Weight centres mm Spring return (continued) Double block 2 spring return operators mechanically interlocked Single-speed C/O + N/O 30 XEN D1631 0.0 32 31 62 61 53 5 0 (1) XEN D2631 0.0 XEN D261 2-speed 2 step C/O + N/O staggered 32 31 30 XEN D161 0.0 DF565592 62 61 53 5 0 (1) XEN D261 0.0 Latching Double block 1 latching operator released by 1 spring return operator Single-speed N/C + N/O 30 XEN D3801 0.170 XEN D3801 0 (1) XEN D801 0.170 Double block 2 latching operators Single-speed N/C + N/O 30 XEN D38 0.170 DF565591 0 (1) XEN D8 0.170 XES B20 Contact blocks for front mounting, snap action Description Application Function Scheme Operator centres Spring return Single block 1 spring return operator (2) mm Reference Weight Single-speed C/O 0 (1) XES B20 0.030 2 1 3 DF56559 Double block 2 spring return operators mechanically interlocked Single-speed C/O 0 (1) XES D81 0.0 22 21 XES D81 2-speed C/O + N/O staggered 3 0 (1) XES D81 0.190 22 21 (1) These contact blocks cannot be mounted in enclosures XAC B0p ( operators in 1 row). (2) Only for mounting with operators XAC B91pp. 30076-EN.indd version: 9.3

References (continued) 6 For control circuits Separate components and spare parts 5300 Contact blocks for front mounting (1) Description Function Scheme Reference Weight Spring return Slow break Operator centres 30 or 0 mm N/O XAC S 0.070 XAC S1p N/C XAC S 0.070 N/O + N/O XAC S 0.070 N/C + N/C XAC S 0.070 21 22 N/C + N/O XAC S15 0.070 5300 Contact blocks for base mounting (1) Description Function Scheme Reference Weight Spring return Slow break N/O XAC S1 0.100 N/C XAC S1 0.100 XAC S1 N/O + N/O XAC S1 0.100 N/C + N/C XAC S1 0.100 21 22 N/C + N/O XAC S151 0.100 DF565595 Pilot light bodies for front mounting Description Supply voltage Scheme Reference Weight Direct supply Bulb not included (2) y 00 V X1 XAC V06 0.050 X2 XAC V06 Direct supply, through resistor Incandescent BA 9s base fi tting 0 V bulb included 0 V X1 XAC V07 0.055 X2 (1) Mounting with operating heads ZA2 Bppp (see page 30076/15). (2) Bulb type for use with direct supply units: BA 9s base fi tting incandescent bulb U y 0 V or neon bulb 0 V y U y 00 V. Maximum power: 2.6 W, maximum Ø: mm, maximum length: 26 mm. See page 30076/18. Characteristics: pages 30076/2 and 30076/ Dimensions: page 30076/ Application schemes: page 30076/ Presentation: page 30076/26 version: 9.3 30076-EN.indd

References 6 For power circuits (direct switching) Separate components and spare parts DF56559 Contact blocks, snap action Description Application Function Max. power/ Scheme Reference Weight 00 V Double block 2-pole 2 spring return operators mechanically interlocked (operator centres: 0 mm) Singlespeed N/O + N/O 2.2 kw XES D91 0.0 3 XES D91 2-speed N/O + N/O + 1 C/O staggered auxiliary contact (1) 2.2 kw XES D91 0.190 3 51 52 61 62 5 6 530368 Double block Singlespeed 3-pole 2 spring return operators mechanically interlocked (operator centres: 0 mm) N/O + N/O + N/O 3 kw XES D2201 0.200 53 5 6 7 63 3 73 XES D2201 N/O + N/O 3 kw XES D21 0.210 + N/O + 1 N/O simultaneous auxiliary contact (1) 5 53 6 7 63 3 73 8 N/O + N/O 3 kw XEN D2251 0.210 + N/O + 1 N/O staggered auxiliary contact (1) 53 5 6 63 7 3 73 8 530391 530369 XAC S399 Isolating block, slow break In the interests of safety, it is imperative that these isolating blocks only be used with a stay put or latching type operating head to ensure complete isolation when the pendant station is not in use. Mounting position Application Function Max. power/ 00 V On front 0 mm centres (2) Emergency stop N/C + N/C + N/C with positive opening operation Scheme Reference Weight 3 kw XAC S399 0.100 21 22 31 32 530366 XAC S99 On front 30 mm centres (2) In base (3) Emergency stop Emergency stop N/C + N/C + N/C with positive opening operation N/C + N/C + N/C with positive opening operation 3 kw XAC S99 0.100 21 22 31 32 3 kw XAC S3991 0.0 21 22 31 32 XAC S3991 (1) Auxiliary contacts are slow break. (2) Mounting with operating heads ZA2 Bppp, except ZA2 BDp and ZA2 BGp (see page 30076/15). (3) Mounting with operating head ZA2 BS9 (see page 30076/15). 30076-EN.indd version: 9.3

References 6 Separate components and spare parts DF565596 XAC B9p Booted operators For use with contact block XEN Bpppp XEN Cpppp XEN Dpppp XES B20 XES D2201 XES D21 XES D2251 Travel Operating temperature mm - 25 + 70 C (1) Colour of insert Sold in lots of Unit reference Weight White 10 XAC B91 0.005 Black 10 XAC B92 0.005 Green 10 XAC B91 0.005 Red 10 XAC B91 0.005 Yellow 10 XAC B95 0.005 Blue 10 XAC B96 0.005 Brown 10 XAC B99 0.005-0 + 70 C (2) White 10 XAC B91 0.005 Black 10 XAC B92 0.005 Green 10 XAC B91 0.005 Red 10 XAC B91 0.005 Yellow 10 XAC B95 0.005 Blue 10 XAC B96 0.005 Brown 10 XAC B99 0.005 DF565597 XES D81 XES D91 XES D81 XES D91 16 mm - 25 + 70 C (1) White 10 XAC B92 0.005 Black 10 XAC B92 0.005 Green 10 XAC B92 0.005 Red 10 XAC B92 0.005 XAC B921p Yellow 10 XAC B9215 0.005 Blue 10 XAC B9216 0.005 Brown 10 XAC B9219 0.005-0 + 70 C (2) White 10 XAC B9221 0.005 Black 10 XAC B9222 0.005 Green 10 XAC B92 0.005 Red 10 XAC B92 0.005 Yellow 10 XAC B9225 0.005 Blue 10 XAC B9226 0.005 DF565598 Booted operators (silicone boot) For use with contact block Operating temperature Brown 10 XAC B9229 0.005 Colour of boot Reference Weight XAC S1p - 25 + 70 C Black ZA2 BP2 0.015 Green ZA2 BP3 0.015 ZA2 BPp Red ZA2 BP 0.015 Yellow ZA2 BP5 0.015 Blue ZA2 BP6 0.015 (1) Polychloroprene boots. (2) Silicone boots. Characteristics: pages 30076/2 and 30076/ Dimensions: page 30076/ Application schemes: page 30076/ Presentation: page 30076/26 version: 9.3 30076-EN.indd

References 6 Separate components and spare parts DF53893 DF53892 530382 530381 530383 530390 ZA2 BS8 ZA2 BS9 ZA2 BDp ZA2 BGp ZA2 BBp ZA2 BV0p Operating heads for front or base mounting (1) Description Colour Type Reference Weight Trigger action latching Emergency stop (2) Turn to release (Emergency stop function) Trigger action latching Emergency stop (2) (3) Key release (n 55) Key withdrawal in rest (unactuated) position (Emergency stop function) Selector switches, standard handle () Key switches (key n 55) (3) Key withdrawal in left and right-hand positions Key switches (key n 55) (3) Key withdrawal in left-hand position Red Ø 30 mm ZA2 BS83 0.028 Ø 0 mm ZA2 BS8 0.0 Red Ø 30 mm ZA2 BS93 0.060 Ø 0 mm ZA2 BS9 0.065 Black 2 position, stay put ZA2 BD2 0.018 3 position, stay put (5) ZA2 BD3 0.018 2 position, stay put ZA2 BG 0.02 3 position, stay put (5) ZA2 BG5 0.02 2 position, stay put ZA2 BG2 0.02 Key switches 2 position ZA2 BG6 0.02 (key n 55) (3) Spring return from right to left Key withdrawal in left-hand position Key switches (key n 55) () (3) Key withdrawal in centre position 3 position, stay put (5) ZA2 BG3 0.02 Wobblesticks (6) Operates in all directions for fast stop Black ZA2 BB2 0.060 Red ZA2 BB 0.060 Operating head for isolating block Description Colour Type Reference Weight Mushroom head, latching Key release (n 55) Key withdrawal in rest (unactuated) position (Emergency stop function) Red Ø 0 mm ZA2 BS 0.065 Pilot light heads Description Colour Reference Weight For use with incandescent bulbs Lens cap with fi xing bezel White ZA2 BV01 0.015 Green ZA2 BV03 0.015 Red ZA2 BV0 0.015 Yellow ZA2 BV05 0.015 Blue ZA2 BV06 0.015 Clear ZA2 BV07 0.015 For use with neon bulbs Lens cap with fi xing bezel Green ZA2 BV0 0.015 Red ZA2 BV0 0.015 Yellow ZA2 BV053 0.015 Clear ZA2 BV073 0.015 (1) The technical characteristics of pendant control stations XAC B and XAC M can only be guaranteed by using the operating heads ZA2 Bpp listed above. (2) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 6020-32, EN/ISO 850, Machinery directive 98/37/EC and standard EN/IEC 6097-5-5. (3) Other key numbers available on request, please consult your Customer Care Centre. () Selector switches or key switches with other mechanical functions: please consult your Customer Care Centre. (5) Only suitable for front mounting. (6) Base mounting recommended. 30076-EN.indd version: 9.3 15

Characteristics 6 For control circuits Separate components: pushbuttons with analogue output (1) Environment Conformity to standards EN/IEC 6097-5-1 Ambient air temperature For storage C - 0 + 70 For operation C - 25 + 70 Degree of protection IP 65 conforming to IEC 60529 Pushbutton operator travel mm Operating force N (start of travel) 9 (end of travel) Mechanical durability 1 (in millions of operating cycles) Connection mm 2 Terminal connectors, maximum clamping capacity: 2 x 1.5 mm 2 or 1 x 2.5 mm 2 Contact block characteristics Thermal current (lthe) A 6 Rated insulation voltage (Ui) V 250, degree of pollution 3, conforming to IEC 6097-1 Rated operational characteristics conforming to 97-5-1 Appendix C Utilisation categories AC-15 and DC- a.c. supply a 50/60 Hz Power broken in VA for 1 million operating cycles d.c. supply c Power broken in W for 1 million operating cycles o Inductive circuit Voltage V 8 0 0 Voltage V 8 0 o VA 30 30 30 o W 8 Analogue circuit characteristics Type of current d.c. Rated supply voltage V 15 Voltage limits V 18 Current consumption ma < 15 Analogue signal output curves and schemes Analogue signal output curves Equivalent output schemes with 15 V supply voltage XEA p15361 XEA p25361 10 5 Travel on pushbutton operator (mm) 1 kω 0 10 V 15 V S 10 kω 0 10 V 1 kω 0 V S 10 kω XEA 15631 XEA 25361 3 0 V 3 + 15 V - 10 V 0 + 10 V Note: supply voltage = 15 V, output voltage = 10 V (if supply voltage < 15 V, output voltage < 10 V) Contact state 0,5 mm - - - 3 0 0, mm,5 mm contact closed contact open (1) Pushbuttons providing an analogue output signal proportional to the distance travelled by the pushbutton operator. References: page 30076/17 Dimensions: page 30076/17 16 version: 9.3 30076-EN.indd

References, dimensions 6 For control circuits Separate components: pushbuttons with analogue output (1) 530386 References Complete pushbuttons (body + operating head), non booted (2) Supply voltage Contact block Reference Weight 0-15 V N/C + N/O at start of travel N/O at end of travel XEA C15361 0.065 XEA Cp5361 0 + 15 V N/C + N/O at start of travel N/O at end of travel XEA C25361 0.065 530392 Complete pushbuttons (body + operating head), booted (2) Supply voltage Contact block Reference Weight 0-15 V N/C + N/O at start of travel N/O at end of travel XEA B15361 0.065 0 + 15 V N/C + N/O at start of travel N/O at end of travel XEA B25361 0.065 530306 XEA Bp5361 Mounting accessories Description For use with Reference Weight Tightening key for fi xing nut XEA Cp5361 ZA2 BZ905 0.060 ZA2 BZ905 XEA Bp5361 XAC X1 0.010 530305 XAC X1 Separate components and spare parts Description Colour of insert Unit reference Weight Booted operator (Sold in lots of 10) White XAC B91 0.005 Black XAC B92 0.005 DF565601 (1) Pushbuttons providing an analogue output signal proportional to the distance travelled by the pushbutton operator. (2) Pushbutton supplied with 1 white insert and 1 black insert. XAC B92 Dimensions XEA Bp5361 XEA Cp5361 Panel cut-out Ø22,3 +0, 0 30 (1) E 17 E 18 = = 30 26 55 = = 30 26 55 E = support panel thickness, 1 to 3.5 mm. (1) Minimum fi xing centres between 2 operators. 30076-EN.indd version: 9.3 17

References 6 Separate components and spare parts 530307 DL1 Cpppp Bulbs Description Voltage Sold in lots of Incandescent BA 9s base fi tting Maximum power: 2.6 W Maximum Ø: mm Maximum length: 28 mm Unit reference Weight 6 V 10 DL1 CB006 0.002 V 10 DL1 CE0 0.002 V 10 DL1 CE0 0.002 8 V 10 DL1 CE08 0.002 0 V 10 DL1 CE0 0.002 530308 DL1 CFppp Neon BA 9s base fi tting Maximum power: 2.6 W Maximum Ø: mm Maximum length: 28 mm 0 V 10 DL1 CF0 0.002 0 V 10 DL1 CF220 0.002 00 V 10 DL1 CF380 0.002 5303 Accessories for booted operators Description Travel Material/ Colour Boots with circlip, without coloured insert Operating temperature Sold in lots of Unit reference Weight mm Polychloroprene - 25 + 70 C 10 XAC B9 0.002 Silicone - 0 + 70 C 10 XAC B9 0.002 16 mm Polychloroprene - 25 + 70 C 10 XAC B921 0.002 XAC B91p Silicone - 0 + 70 C 10 XAC B922 0.002 530310 Coloured inserts for booted operators ( and 16 mm travel) White 10 XAC B901 0.001 Black 10 XAC B902 0.001 Green 10 XAC B903 0.001 XAC B92p Red 10 XAC B90 0.001 Yellow 10 XAC B905 0.001 530309 Blue 10 XAC B906 0.001 XAC B90p Brown 10 XAC B909 0.001 Characteristics: pages 30076/2 and 30076/ Dimensions: page 30076/ Application schemes: page 30076/ Presentation: page 30076/26 18 version: 9.3 30076-EN.indd

References (continued) 6 Separate components and spare parts 5303 5303 Complementary accessories Description For use with Reference Weight Protective cable sleeve with cable tie (for tightening sleeve onto cable) Enclosures XAC B219 and XAC B220 (2 operators) For cable Ø 7 mm XAC B9 0.065 XAC B9 Enclosures XAC Bppp with to operators and XAC Mppp with and 8 operators For cable Ø 10 22 mm XAC B960 0.0 For cable Ø 22 35 mm XAC B965 0.160 Blanking plug with seal and fi xing nut ZB2 SZ3 0.005 XAC B960 Adaptor for use with protective cable sleeve for cable Ø 10 22 mm Self-supporting cable type BBAP XAC B961 0.025 5303 Lower support ring Single row enclosures XAC B and XAC M XAC B971 0.015 XAC B971 2 row enclosures XAC B XAC B972 0.020 DF565602 Protective guards for base mounted units Emergency stop pushbutton XAC B982 0.050 DF56560 XAC B972 Tools Description For use with Reference Weight Tightening key Bezels XAC X1 0.010 Units mounted in base of enclosure XAC X905 0.015 XAC B982 530318 530319 Bulb extractor BA 9s base fi tting bulbs XBF X 0.003 XAC X1 XAC X905 30076-EN.indd version: 9.3 19

References 6 Legends 30 x 0 mm (with symbols conforming to NF E 52-1) DF565666 Symbol Reference Symbol Reference Weight Symbol Reference Symbol Reference Weight Vertical mounting 0 mm centres Horizontal mounting 30 mm centres Vertical mounting 0 mm centres Horizontal mounting 30 mm centres Raise, slow Lower, slow ZB2 BY951 ZB2 BY901 0.001 ZB2 BY295 ZB2 BY290 0.001 30 Raise, fast Lower, fast ZB2 BY952 ZB2 BY902 0.001 ZB2 BY2955 ZB2 BY2905 0.001 0 Raise, slow-fast Lower, slow-fast ZB2 BY953 ZB2 BY903 0.001 ZB2 BY2956 ZB2 BY2906 0.001 Right, slow Left, slow ZB2 BY901 ZB2 BY907 0.001 ZB2 BY290 ZB2 BY2910 0.001 Right, fast Left, fast ZB2 BY902 ZB2 BY908 0.001 ZB2 BY2905 ZB2 BY29 0.001 Vertical mounting 0 mm centres Horizontal mounting Right, slow-fast Left, slow-fast 30 mm centres ZB2 BY903 ZB2 BY909 0.001 ZB2 BY2906 ZB2 BY29 0.001 DF565665 Forward, slow Reverse, slow ZB2 BY963 ZB2 BY9 0.001 ZB2 BY2966 ZB2 BY2916 0.001 White bacround, black symbol Forward, fast Reverse, fast ZB2 BY96 ZB2 BY9 0.001 ZB2 BY2967 ZB2 BY2917 0.001 Forward, slow-fast Reverse, slow-fast ZB2 BY965 ZB2 BY915 0.001 ZB2 BY2968 ZB2 BY2918 0.001 Black bacround, white symbol Slew right, slow Slew left, slow ZB2 BY919 ZB2 BY919 0.001 ZB2 BY2922 ZB2 BY2922 0.001 Red bacround, white symbol Slew right, fast Slew left, fast ZB2 BY920 ZB2 BY920 0.001 ZB2 BY29 ZB2 BY29 0.001 Slew right, slow-fast Slew left, slow-fast ZB2 BY921 ZB2 BY921 0.001 ZB2 BY29 ZB2 BY29 0.001 Slow Fast ZB2 BY9 ZB2 BY9 0.001 ZB2 BY93 ZB2 BY93 0.001 Klaxon Start-Klaxon ZB2 BY982 ZB2 BY932 0.001 ZB2 BY985 ZB2 BY935 0.001 Start Stop ZB2 BY980 ZB2 BY930 0.001 ZB2 BY2931 ZB2 BY2931 0.001 Characteristics: pages 30076/2 and 30076/ Dimensions: page 30076/ Application schemes: page 30076/ Presentation: page 30076/26 20 version: 9.3 30076-EN.indd

References 6 Legends 30 x 0 mm DF565667 White Black Red Text Reference Weight b Start functions: white characters on black bacround b Stop functions: white characters on red bacround Text Reference Weight ZB2 BY2101 Blank Black or red bacround ZB2 BY2101 0.001 White or yellow bacround ZB2 BY101 0.001 DF565668 Black White Yellow With French text With English text For pushbuttons For pushbuttons Marche ZB2 BY2103 0.001 Start ZB2 BY03 0.001 Arrêt ZB2 BY210 0.001 Stop ZB2 BY0 0.001 Avant ZB2 BY2105 0.001 Forward ZB2 BY05 0.001 Arrière ZB2 BY2106 0.001 Reverse ZB2 BY06 0.001 ZB2 BY101 Montée ZB2 BY2107 0.001 Up ZB2 BY07 0.001 Descente ZB2 BY2108 0.001 Down ZB2 BY08 0.001 Droite ZB2 BY2109 0.001 Right ZB2 BY09 0.001 Gauche ZB2 BY20 0.001 Left ZB2 BY10 0.001 En service ZB2 BY21 0.001 On ZB2 BY 0.001 Hors service ZB2 BY22 0.001 Off ZB2 BY 0.001 Sous tension ZB2 BY26 0.001 Power on ZB2 BY26 0.001 Lent ZB2 BY27 0.001 Slow ZB2 BY27 0.001 Vite ZB2 BY28 0.001 Fast ZB2 BY28 0.001 Klaxon ZB2 BY25 0.001 For selector switches For selector switches Arrêt-Marche ZB2 BY2166 0.001 Hors-En ZB2 BY2167 0.001 Off-On ZB2 BY67 0.001 With special texts b Specify text when ordering, b 2 lines maximum, characters per line. White characters on black bacround White characters on red bacround Other versions ZB2 BY2002 0.001 Black characters on white bacround ZB2 BY200 0.001 Black characters on yellow bacround Legends with texts in other languages. Please consult your Customer Care Centre. ZB2 BY001 0.001 ZB2 BY005 0.001 30076-EN.indd version: 9.3 21

References 6 Twin legends for tower cranes Legends with white symbols on black bacround Function Symbol Reference Weight Function Symbol Reference Weight 0 mm operator centres (for enclosures with 2 to 8 operators and operators in 2 rows) Hoist Raise Lower XAC Y970 0.002 Long travel Forward Reverse XAC Y972 0.002 Slew Right Left XAC Y971 0.002 Trolley Forward Reverse XAC Y973 0.002 30 mm operator centres (for enclosures with operators in 1 row) Hoist Raise Lower XAC Y3970 0.002 Long travel Forward Reverse XAC Y3972 0.002 Slew Right Left XAC Y3971 0.002 Trolley Forward Reverse XAC Y3973 0.002 Characteristics: pages 30076/2 and 30076/ Dimensions: page 30076/ Application schemes: page 30076/ Presentation: page 30076/26 22 version: 9.3 30076-EN.indd

Dimensions 6 (XAC M: products for maintenance purposes only) Pendant control stations XAC Bppp (2 and 3-way) XAC Bppp (2 to -way, 1 row) XAC Mppp ( to 8-way, 1 row) XAC Bppp (-way, 2 rows) 0 0 200 265 60 7,5 85 b1 b1 d b d b 76 100 (1) c 76 100 (1) c Protective cable sleeves internal Ø Ø7 Ø9 Ø Ø internal Ø Ø10 Ø 16 Ø16 19 Ø19 22 internal Ø Ø22 26 Ø26 29 Ø29 32 Ø32 35 (1) With mushroom head operator. Number of operators 2 6 8 (1 row) (2 rows) b 09 99 589 679 679 593 b1 220 310 00 90 90 0 c 98 98 98 98 98 158 d 0 0 0 0 30 0 Protective guards XAC B982 Lower support rings XAC B971, B972 8 30076-EN.indd version: 9.3

Application schemes (typical examples) 6 Control circuits For control of single-speed reversing motor Contact block XES D81 For control of 2-speed reversing motor Contact block XES D81 S1 A2 22 3 S2 21 22 KM2 A1 KM1 A2 A2 21 S1 A1 S2 KM1 A1 A1 KM A1 KM2 A2 A2 Power circuits For control of single-speed reversing motor. 2-phase switching Contact block XES D91 KM: high speed contactor Application example: Combined with 3-pole isolating block XAC S399 or XAC S3991, shown in the unoperated position (pendant station supplied ), fi tted with key release trigger action latching Emergency stop operator (ZA2 BS9). L1 L2 L3 S1 S2 U L1 L2 L3 3 V W Q S1 S2 U V 3 W 21 22 31 32 Characteristics: pages 30076/2 and 30076/ Dimensions: page 30076/ Application schemes: page 30076/ Presentation: page 30076/26 version: 9.3 30076-EN.indd

Application schemes (typical examples) (continued) 6 Power circuits (continued) For control of 2-speed reversing motor (motors with separate windings only). 2-phase switching Contact block XES D91 Application example: Combined with 3-pole isolating block XAC S399 or XAC S3991, shown in the unoperated position (pendant station supplied ), fi tted with key release trigger action latching Emergency stop operator (ZA2 BS9). L1 L2 L3 S1 5 22 21 Q 52 51 S2 3 62 6 61 32 31 L1 L2 L3 S1 52 51 S2 3 62 6 61 5 Y Y U1 U2 U1 U2 V1 V2 V1 V2 W1 W2 W1 W2 For control of single-speed reversing motor. 3-phase switching, reversing by 2-phase inversion Contact block XES D2201 Contact block XES D21 with line contactor L1 L2 L3 1 F1 2 L1 L2 L3 5 6 7 53 63 73 3 S1 S2 U V W 5 A1 6 7 53 63 73 3 A1 1 2 3 KM1 2 6 S1 S2 U V W 8 Y Y 30076-EN.indd version: 9.3 25

Presentation 6 XEA B p5361 XEN C XEN D26 XEA Cp 5361 XAC B9p XES B20 XES D1pp 1 XAC B921p ZA2 BS83 XEN D3801 ZB2 BYpppp ZA2 BS9 XEN B81 ZB2 BY pppp ZA2 BS8 XAC S99 XES D22p 1 ZA2 BS93 ZB2 BYpppp XAC S399 ZA2 BDp XAC S1p ZA2 BGp XAC V0 p XAC S1p1 XAC B982 ZA2 BBp XAC S3991 ZA2 BV0 p ZA2 BS8 ZA2 BS9 ZB2 SZ3 26 version: 9.3 30076-EN.indd

Order form (specimen suitable for photocopying) 6 (XAC M: products for maintenance purposes only) Variable composition stations, factory assembled 5303 Customer Schneider Electric Industries Company Order N Delivery date Sales offi ce - Subsidiary Co. Order N Enter the order with XAC B09 reference (for enclosures XAC B) or XAC M09 reference (for enclosures XAC M) 1 2 3 5 6 7 8 9 10 cut-outs, centres: 0 mm 16 1 Unit reference of empty enclosure see page 30076/7 XAC Legends see page 30076/20 Contact blocks or pilot light bodies see page 30076/10 Number of identical stations Enclosure price (1) Operating heads or pilot light heads or blanking plug see page 30076/15 Reference Unit price Reference Unit price Reference Unit price Total price 2 52568 3 5 6 1 2 3 5 6 7 8 2 to 8 cut-outs, centres: 0 mm 15 7 8 9 10 Unit mounted in base of enclosure (if required) 525685 Factory assembled: Number of heads or blanking plugs to be fi tted X Additional cost XAC 9VA for fi tting of 1 head or 1 blanking plug 1 2 3 5 6 7 8 9 10 cut-outs, centres: 30 mm 15 Complementary accessories, see page 30076/19 (cross the appropriate box or boxes) Description Reference Unit price Adaptor for self-supporting cable type BBAP for XAC B961 use with cable entry sleeve Ø 10 to 22 mm 15 Lower support ring for single row enclosures XAC B971 15 Lower support ring for 2 row enclosures XAC B972 16 Protective guard for key release latching mushroom head pushbutton, mounted in base Total price of assembled pendant station (1) Obtain the empty enclosure price. XAC B982 30076-EN.indd version: 9.3 27