VOF XX - XXX - X

Similar documents
VMS-300A - XX - XXX - X

For more information, please visit the product page. output. output current max (A)

For more information, please visit the product page If your application requires forced air, view our Dc Fans. output. output current max (ma)

PDAM500 Series 500W Power Supply

300W AC-DC Power Supply with PFC CFM300M Series APPLICATION NOTE

For more information, please visit the product page. input voltage 1 range. output voltage

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

C B. Models. Models 2MOPP

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

General. Environmental. EMC & Safety

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

AC-DC Switching Power Module CFM61S Series APPLICATION NOTE

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

HEC-45LTN-45PFAS Rev A

Metal Case Power Supplies

1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W

Watts HCP Series

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

HEC-30/35LTA-33TDAA Rev A

HEC-35LTA-XXTSAA Rev A

Model Number Output V1/V2/V3 Output I1/I2/I3 max. Ripple & Noise Efficiency(min/nom) Capacitive Load

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

V78 XX X SERIES: V DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR MODEL PART NUMBER KEY. RoHS

1500W Single Output Power Supply AK V 100A 0~100A 1500W. 150mVp-p. Adjustment of output current is between 40 ~ 105% of rated output

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

800W Single Output Power Supply

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

TRC ELECTRONICS, INC AC/DC Power Supply Built-In Fan PFC 3000W MEAN WELL RSP-3000 Series

3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p

SYNRAD PS DC Power Supply (Meanwell RSP )

150 Watt Industrial (WLT)

HEC-40LTN-XXPSCA Rev A

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

RSP-2400 series. 2400W Power Supply with Single Output. File Name:RSP-2400-SPEC Sicherheit ID

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

TRC ELECTRONICS, INC AC/DC Power Supply Built-In Fan PFC 2400W MEAN WELL RSP-2400 Series

RSP-3000 series. 3000W Power Supply with Single Output. File Name:RSP-3000-SPEC Sicherheit ID

LFWLP W 12V 15.00A 25.00A 92%

Electrical Specifications

Ripple & Max. capacitive Output Current

HRPG-1000 series. 1000W Single Output with PFC Function. File Name:HRPG-1000-SPEC Sicherheit ID

3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

RSP-1500 series. 1500W Single Output Power Supply

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

General. Environmental. EMC & Safety

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

1. Output Power vs. Ambient temperature a. 3.3 and 5 V models b. All other models. Load factor Convection

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

RSP-1000 series. 1000W Power Supply with Single Output. File Name:RSP-1000-SPEC Sicherheit ID

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

IEC/EN/UL60950 & CE certified, EN55032 Class B

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

Line Reg Load Reg Ripple Efficiency *Model Number Output V Output I (nom/max) (nom/max) & Noise (min/nom)

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

RSP-1000 series. 1000W Power Supply with Single Output. File Name:RSP-1000-SPEC Sicherheit ID

LB115S 115W Single Output

HEC-70LCN-350TDAF Rev B

Electrical Specifications

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

AC-DC ITE & Medical Switching Power Supply

VFB400W - QXX - SXXX

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

Electrical Specifications

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

1000W Single Output Medical Type. MSP-1000 series. File Name:MSP-1000-SPEC

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

RSP-1500 series. 1500W Single Output Power Supply. File Name:RSP-1500-SPEC Sicherheit ID

Transcription:

date 01/31/018 page 1 of 10 SERIES: VOF-300 DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 300W continuous power universal input voltage range industry standard 3 x 5 footprint power factor correction remote voltage sense remote on/off control fan & 5 Vdc aux outputs covered and open-frame configurations over voltage, over current, over temperature, and short circuit protections UL/cUL & TUV safety approvals efficiency up to 94 MODEL output voltage (Vdc) output current max (A) output power 1 max (W) ripple and noise efficiency 3 max (mvp-p) VOF-300-1 1 5 300 10 9.5 VOF-300-4 4 1.5 300 150 93.5 VOF-300-36 36 8.34 300 150 93.5 VOF-300-48 48 6.5 300 150 94 Vstb 4 5 1 5 -- Notes: 1. Maximum output power of 300 W (5 W for Vstb) with 10 CFM forced air, 00 W (3 W for Vstb) with convection cooling.. At full load, nominal input, 0 MHz bandwidth oscilloscope, output terminated with 10 μf electrolytic and 0.1 μf ceramic capacitors. 3. At full load, 5 C, 30 Vac input. 4. Standby output voltage. Present on all models. 5. All specifications are measured at Ta=5 C, 30 Vac input voltage, and 60 rated output load unless otherwise specified. PART NUMBER KEY typ () VOF-300 - XX - XXX - X Base Number Output Voltage Chassis: blank = open-frame CNF = covered Input Connector: blank = TAIWAN KING TERMINAL PVHI series 1 = LONG CHU P3060 series

date 01/31/018 page of 10 INPUT voltage 90 64 Vac frequency 47 63 Hz current at Vac at 40 Vac inrush current at 40 Vac, 5 C, cold start 30 A leakage current 3.5 ma power factor correction meets EN 60-3- no load power consumption measured with the PS-ON signal configured to OFF 0.3 W OUTPUT output capacitance initial set point accuracy line regulation load regulation at 115/30 Vac, full load 1 Vdc output models 4 Vdc output models 36 Vdc output models 48 Vdc output models at full load, 5 C Vo Vstb high line to low line at full load Vo Vstb from full to 10 load Vo Vstb ±1 ±3 4.0 1.8 5,000 1,500 5,000 3,750 hold-up time at 115 Vac 16 ms adjustability built in trim pot (VR) ±5 switching frequency at full load 60 80 khz temperature coefficient ±0.05 / C PS-ON signal 1 power good (PG) standby output voltage fan output Notes: power on power off ±0.5 ±1 PS-ON 0 Vdc PS-ON = 0V 4.5 ma PS-ON = NC (internal circuit will drive PS-On to 11~16 Vdc) PS-ON = NC 0 ma TTL goes high 50~50 ms after powered on TTL goes low 5~0 ms before 90 Vo 5 Vdc / 1 A 1 Vdc / 500 ma 1. When not used, short PS-ON & signal GND. PROTECTIONS over voltage protection latch mode 1 Vdc output models 4 Vdc output models 36 Vdc output models 48 Vdc output models over current protection hiccup, auto recovery 130 150 180 short circuit protection auto recovery over temperature protection auto recovery (temperature of C37) 110 C ±1 ±5 15 30 43 56 A A μf μf μf μf Vdc Vdc Vdc Vdc

date 01/31/018 page 3 of 10 SAFETY & COMPLIANCE isolation voltage input to output for 1 minute input to earth for 1 minute output to earth for 1 minute 3,000 1,500 500 isolation resistance MΩ safety approvals safety class conducted emissions radiated emissions harmonic current emissions IEC60950-1, EN60950-1, UL60950-1 (nd edition) class I EN5503:01+AC:013, EN550:010+AC:011, Class B, FCC CFR 47 Part 15 Subpart B EN5503:01+AC:013, EN550:010+AC:011, Class B, FCC CFR 47 Part 15 Subpart B IEC 60-3-:014, Class C & D voltage fluctuations & flicker IEC 60-3-3:013 ESD radio-frequency, Continuous radiated disturbance EFT/burst surge conducted immunity power frequency magnetic field voltage dips voltage interruptions IEC 60-4-:008, ±kv, ±4kV, Class A IEC 60-4-3:010, Class A IEC 60-4-4:01, ±0.5kV, ±1kV, ±kv, Class A IEC 60-4-5:005, L-N: ±0.5kV, ±1kV, L-PE, N-PE: ±0.5kV, ±1kV, ±kv, Class A IEC 60-4-6:013, Class A IEC 60-4-8:009, Class A IEC 60-4-11:004, Dip: 30 reduction, Dip: 70 reduction, Class A IEC 60-4-11:004, >95 reduction, Class B MTBF as per MIL-HDBK-17F, at 115 Vac, 5 C, GB 160,000 hours RoHS 011/65/EU Vac Vac Vac Notes: 1. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. ENVIRONMENTAL operating temperature see derating curves -40 80 C storage temperature -40 85 C operating humidity non-condensing 93 operating altitude 5000 m vibration as per MIL-STD-810F Table 514.5C-VIII; 15~000 Hz for 1 hour on each axis for 3 hours shock as per MIL-STD-810F Table 516.5, Table 516.5-1; for 10 ms on each axis 3 times 4 G 75 G Notes:. See Installation Instructions for mounting requirements. DERATING CURVES VOF-300 Output Power vs. Input Voltage (Natural Convection) VOF-300-CNF Output Power vs. Input Voltage (Natural Convection) 300 300 50 50 Load (W) 00 150 Load (W) 00 150 50 50 90 110 130 150 170 190 10 30 50 64 90 110 130 150 170 190 10 30 50 64 Input Voltage (Vac) Input Voltage (Vac)

date 01/31/018 page 4 of 10 DERATING CURVES (CONTINUED) VOF-300 Output Power vs. Ambient Temperature (Natural Convention) Load (W) 300 50 00 150 Input voltage 0~64 Vac Input voltage 90~00 Vac VOF-300-CNF Output Power vs. Ambient Temperature (Natural Convection) Load (W) 300 Input voltage 0~64 Vac 50 00 150 Input voltage ~00 Vac 50 50-40 -30-0 -10 0 10 0 30 40 50 60 70 80 Ambient Temperature ( C) VOF-300 Output Power vs. Ambient Temperature (with 10 CFM airflow) -40-30 -0-10 0 10 0 30 40 50 60 70 80 Ambient Temperature ( C) VOF-300-CNF Output Power vs. Ambient Temperature (with 10 CFM airflow) Load () 80 60 40 Load () 80 60 40 0 0-40 EFFICIENCY CURVES -30-0 -10 0 10 0 30 40 50 60 70 80 Ambient Temperature ( C) 1 Vdc Output Efficiency Curve (at 5 C) -40-30 -0-10 0 10 0 30 40 50 60 70 80 Ambient Temperature ( C) 4 Vdc Output Efficiency Curve (at 5 C) 36 Vdc Output Efficiency Curve (at 5 C) 48 Vdc Output Efficiency Curve (at 5 C)

date 01/31/018 page 5 of 10 MECHANICAL dimensions weight cooling CN1 input connector CN1 input connector (optional) CN4 output connector CN5 output connector output terminals MECHANICAL DRAWING VOF-300 models: 5.00 x 3.00 x 1.38 (17 x 76. x 35.1 mm) VOF-300-CNF models: 5.35 x 3.46 x 1.59 (136 x 88 x 40.4 mm) VOF-300 models VOF-300-CNF models external fan CN1 mates with JST housing VHR series or equivalent CN1 mates with MOLEX housing 5195 series or equivalent CN4 mates with JST housing PH series or equivalent CN5 mates with JST housing PH series or equivalent +Vo & -Vo terminals are M3 screws that mate with round or Y terminals with max OD of 6.75 mm and max ID of 3.9 mm 40 550 inch inch g g Open-frame units: inch [mm] tolerance: X.XXX = ±0.00 [±0.50] 5.000 [17.00] 4.551 [115.60] CN1 1 ACL - 0.4 [5.70] FAN 5mm Air flow direction 10CFM 3 ACN CN4 1 -FAN +FAN 3 GND 4 +5 VSB 5 GND 6 PS-ON CN1 ACL 1 ACN 3 VR 4 3 1 CN5 +Vo -Vo 0.4 [5.70].551 [64.80] 3.000 [76.0] 4 3 1 CN5 cross sectional view A Scale 1:1 CN5 CN4 1 3 4 56 1 GND PG 3 -Sense 4 +Sense 4-M4*0.7 0.197 [5.00]max 0.063 [1.60] 1.13 [8.5]max

date 01/31/018 page 6 of 10 MECHANICAL DRAWING (CONTINUED) Covered units: inch [mm] tolerance: X.XXX = ±0.00 [±0.50] CN1 5.35 [136.00] FAN 5mm Air flow direction 10CFM 1 ACL - 3 ACN CN4 1 -FAN +FAN CN1 ACL 1 ACN 3 +Vo -Vo 3.43 [87.00] 3.46 [88.00] 4 3 1 CN5 3 GND 4 +5 VSB 5 GND 6 PS-ON CN5 1 GND VR 1.591 [40.40] cross sectional view A Scale 1:1 CN4 1 3 4 56 PG 3 -Sense 4 +Sense 0.437 [11.10].55 [64.80] 0.40 [10.0] 4.55 [115.60]

date 01/31/018 page 7 of 10 INSTALLATION INSRUCTIONS The VOF-300 series has (4) 4 mm diameter mounting holes that can be used in (3) types of installations. Type 1 Mounting from top with spacers (required to meet vibration specifications) Spacer: 4 mm diameter max, 8 mm high minimum Screw Size: (4) M3X0.5 Mounting torque: 3 kgf-cm Type Mounting from top without spacers Screw Size: (4) M3X0.5 Mounting torque: 3 kgf-cm Type 3 Mounting from bottom Screw Size: (4) M4X0.7 Mounting torque: 7 kgf-cm Mounting Torque VOF-300 VOF-300-CNF

date 01/31/018 page 8 of 10 INSTALLATION INSRUCTIONS (CONTINUED) Output Terminals Mate with round or Y terminals with max OD of 6.75 mm and max ID of 3.9 mm Terminal Size: () M3 Torque: 3 kgf-cm Mounting Clearance Allow at least 4 mm side clearance and 5 mm height clearance. If clearances aren t met, the isolation and withstand specifications may not be met. Field Ground Should be connected to the earth (ground) terminal of the apparatus otherwise conducted noise and output noise will increase.

date 01/31/018 page 9 of 10 APPLICATION NOTES On/off Remote Control A PS On/Off remote control is provided in CN4. See Figure 1 for the PS-ON diagram and control function. Figure 1 VOF-300 Note: Power on: V PS-ON V, I PS-ON ma (PS-ON and GND short, I PS-ON = 4.5 ma typical) Power off: Open circuit, V PS-ON = 11~16 V When the PS On/off remote control function is not used, connect a short circuit between the PS-ON control & the signal GND. Output Remote Sensing The VOF-300 series can remotely sense both lines of the output. The feature moves the effective voltage regulation point from the output of the unit to the point of connection of the remote sense pins. This feature automatically adjusts the real output in order to compensate for voltage drops in distribution and maintain a regulated voltage at the point of load. The remote sense voltage range is as follows: [(+Vout) (-Vout)] [(+Sense) (-Sense)] 10 Vo_nominal If the remote sense is not used, the sense pins should be connected locally to the respective Vout pins. The remote sense pins are located on CN4. Figure AC_L AC_N PE VOF-300 Series +Vo +Sense -Sense -Vo Load

date 01/31/018 page 10 of 10 REVISION HISTORY rev. description date 1.0 initial release 1/06/016 1.01 updated datasheet 01/31/018 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 0050 SW 11th Ave. Tualatin, OR 9706 800.75.4899 Fax 503.61.383 techsupport@ CUI offers a two () year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.