Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Similar documents
Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR31, miniature design

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Analogue Temperature Transmitter

Resistance thermometer Model TR30, compact design

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

Field indicator for current loops with HART communication Models DIH50, DIH52

HART field temperature transmitter Models TIF50, TIF52, TIF62

Temperature transmitter itemp PCP DIN rail TMT 121

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Field indicator for current loops with HART communication Models DIH50, DIH52

Hand-held temperature calibrator Model CEP3000

Temperature Transmitter itemp RTD DIN rail TMT 127

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Temperature transmitter itemp RTD DIN rail TMT 127

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Temperature head transmitter itemp PCP TMT 181

itemp HART DIN rail TMT112

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Resistance Thermometers Model Series TR7X0, Sheathed Design

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Temperature Input Module for Zone 1 Series 9482/32

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Submersible pressure sensor For water and wastewater Model LW-1

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Temperature head transmitter itemp TC TMT 188

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

SINEAX TI 807 Passive DC signal isolator

Indicator for panel mounting Model

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Submersible pressure sensor For oils and fuels Model LF-1

Temperature head transmitter itemp PCP TMT 181

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Flush pressure transmitter For viscous and solids-containing media Model S-11

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

itemp PA TMT184 Technical information

OPTITEMP TT 10 C/R Technical Datasheet

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Submersible pressure sensor For superior applications Model LF-1

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Positioner with HART Communication Type 3780

RMA42. Technical Information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Head mounted Temperature Transmitter TF02/TF02-Ex

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

OEM pressure transmitter For mobile working machines Model MH-3

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Rail mounted Temperature Transmitter TH102/TH102-Ex

Technical Information Barrier RB223

Isolators A3/1.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

SALES SERVICE +358 (0)

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

High-precision process calibrator Model CED7000

Analog Universal Module HART for Zone 2 Series 9468/33

Screw-in resistance thermometers with plug connector

Isolators A3/1.

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Pressure transmitter for general industrial applications Model A-10

OPTITEMP TT 20 Technical Datasheet

In-Line Resistance Thermometers Model TR25

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Pressure transmitter for general industrial applications Model A-10

Binary Output without Power Supply Series 9176

Technical Information itemp TMT180

Temperature Transmitters TMT 136, TMT 137

Digital indicator for panel mounting With multi-function input Model DI25

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Technical Data. General specifications. Rated operating distance s n 3 mm

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Transcription:

Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry Special Features T Analogue signal processing, ideal for multiplex-systems T Configuration via Windows-PC, simulation of the sensor not necessary T Sensor burnout signalling according to NAMUR NE 43 T Configuration Software WIKA_TT current 6-language version T Compact design Analogue Temperature Transmitter Model T24.10 Description Temperature transmitter for Pt100 in 2- or 3-wire connection with 4... 20 ma analogue output (loop powered 2 wire technique) The T24 temperature transmitter combines the known quick response of an analogue transmitter with the flexibility of configuration by means of Windows PC. The quick stabilisation of the output current after excitation voltage has been applied enables the use of this transmitter in multiplex systems. Setting of the measuring range, type of sensor and sensor burnout behaviour takes only a matter of seconds thanks to the easy-to-use Windows configuration software. Timeconsuming adjustment and sensor simulation are not required for this transmitter. The T24 can be remotely configured from the control room via the current loop. Possible measuring errors which might for example, result from poor thermometer position, can be compensated by means of the function Adaption. Write protection and an increased ambient temperature range complete the spectrum of features offered by the temperature transmitter. Due to its flexibility and reliability the temperature transmitter T24 is suited for a wide range of applications in the machine industry and plant construction. Versions with explosion protection approval in accordance with ATEX are available for applications in the process industry. As a result of its extremely compact design this WIKA temperature transmitter can be fitted into any DIN connection head of form B. The transmitters are delivered with a basic configuration (see ordering information). Alternatively, upon request, transmitters can be delivered with a customized configuration within the given limits. Page 1 of 8

Specification Model T24.10 Input Measuring range configurable with Windows PC Model T24.10.1Px / T24.10.2Px Pt 100 DIN EN 60 751 2 wire, 3 wire Measuring range maximum T24.10.1Px: -150 C... +850 C T24.10.2Px: -200 C... +850 C Measuring span T24.10.1Px: minimum 20 K T24.10.2Px: minimum 50 K Initial value of measuring range, configurable T24.10.1Px: -150 C... +150 C T24.10.2Px: -200 C... +200 C End of measuring range, configurable Dependent from initial value of measuring range, see diagram page 4 Basic configuration 3 wire 0... 150 C Sensor current approx. 0.5 ma Connection leads effect ± 0.2 K / 10 Ω each wire 1) permissible load resistance 30 Ω each wire, 3 wire symmetric Analogue output 4 20 ma 2 wire design Measuring deviation per DIN EN 60TT0, 23 øc œ 5 K ± 0.2 % 2) iinearization Linear to temperature per DIN EN 60751 Linearity error ± 0.1 % 3) Temperature coefficient TK zero ± 0.1 % / 10 KTa or 4) ± 0.15 K / 10 KTa span ± 0.15 % / 10 KTa Rising time t90 < 1 ms Switch-on delay, electric < 10 ms Signalling sensor burnout Configurable: NAMUR downscale < 3.6 ma (typical 3 ma) NAMUR up scale > 21.0 ma (typical 23 ma) sensor short circuit Not configurable, in general NAMUR downscale < 3.6 ma (typical 3 ma) 5) Load RA RA (UB - 10 V ) / 0.022 A with RA in Ω and UB in V Load effect ± 0.05 % / 100 Ω Power supply effect ± 0.025 % / V Power supply By the 4... 20 ma-loop Model T24.10.xx0 (without Ex-protection) DC 10 36 V Model T24.10.xx2 (with Ex-protection, intrinsic safe ia) DC 10 30 V Model T24.10.xx6 (with Ex-protection, CSA Class I) DC 10 30 V Model T24.10.xx8 (with Ex-protection, FM Class I) DC 10 30 V Model T24.10.xx9 (with Ex-protection, EEx nl/na) DC 10 36 V Input power supply protection Reverse polarity Max. permissible ripple 10 % with 24 V / maximum load 300 Ω Ex-protection per Directive 94/9/EC ATEX Intrinsic Safety per EN 50 020 EC Type Test DMT 02 ATEX E 025 X Model T24.10.xx2 II 1G EEx ia IIB / IIC T4 / T5 / T6 Permissible ambient temperature -40 C +85 C with T4-40 C +75 C with T5-40 C +60 C with T6 Maximum values for connection of the U i = DC 30 V I i = 120 ma P i = 800 mw current loop circuit (connections + and -) C i = 6.2 nf L i = 110 µh Maximum values for connection of the U o = DC 6.4 V I o = 42.6 ma P o = 37.1 mw sensor circuit (connections 1 up to 3) Group II B: C o = 500 µf L o = 50 mh Group II C: C o = 20 µf L o = 10 mh Load diagram The permissible load is dependent upon the loop power supply voltage. 1) For 3 wire sensor connection, with 2 wire connection a total lead resistance up to 20 Ω is compensatable, otherwise the lead resistance causes additional error 2) For measuring span lower than 50 K additional: 0.1 K, For measuring span higher than 550 K additional: 0.1 % 3) œ 0.2 % with measuring ranges with initial value lower than 0 øc or measuring span higher than 800 K 4) Whichever is greater; between the standard range of ambient temperature -40 øc Ta +85 øc, with option "extended range of ambient temperature" the double value is valid outside the standard range 5) Temperature value, in case of short between wire no. 2 and no. 3 (operation of sensor in 2 wire connection) load RA in Ω voltage U B in V 2363156.01 wire number: 13T5890.01 Specifications in % refers to the measuring span R A load T a ambient temperature T C temperature coefficient U B loop power supply voltage, see power supply Page 2 of 8

Specification, continued Model T24.10 Ex-protection, Intrinsic Safety per CSA CSA File No. LR 105000-6 Model T24.10.xx6 Class I, Division 1, Groups A, B, C and D Permissible ambient temperature max. +85 C with T4 max. +75 C with T5 max. +60 C with T6 Maximum values for connection of the U max = DC 30 V I max = 120 ma P max = 800 mw current loop circuit (connections + und -) C i = 6.2 nf L i = 110 µh Maximum values for connection of the U oc = DC 6.4 V I sc = 42.6 ma P max = 37.1 mw sensor circuit (connections 1 up to 3) C a = 20 µf L a = 10 mh Ex-protection, Intrinsic Safety per FM Installation Drawing No. 2475796 Model T24.10.xx8 Class I, Division 1, Groups A, B, C and D Permissible ambient temperature -40 C +85 C with T4-40 C +75 C with T5-40 C +60 C with T6 Maximum values for connection of the U max = DC 30 V I max = 120 ma P i = 800 mw current loop circuit (connections + und -) C i = 6.2 nf L i = 110 µh Maximum values for connection of the U oc = DC 6.4 V I sc = 21.1 ma P o = 34 mw sensor circuit (connections 1 up to 3) C a = 20 µf L a = 10 mh Ex-protection per Directive 94/9/EC energy-limited resp. non sparking equipment per EN 50 021 EC Type Test DMT 99 E 088 X Model T24.10.xx9 II 3G EEx nl/na IIC T4 / T5 / T6 Permissible ambient temperature -40 C +85 C with T4-40 C +65 C with T5-40 C +50 C with T6 Maximum values for connection of the U i = DC 36 V current loop circuit (connections + und -) C i = 6.2 nf L i = 110 µh Maximum values for connection of the U o = DC 5.4 V I o = 0.5 ma sensor circuit (connections 1 up to 3) C o = 200 µf L o = 1000 mh Approval Germanischer Lloyd Approval certificate no. 47183-03 HH Model T24.10.xxx-G Environmental category D, F, H, EMC1 Approval Gosstandart Approval certificate DE.C.32.001.A no. 15279 Electromagnetic compatibility (EMC) per EMC Directive 89/336/EWG DIN EN 61 326:2002 Ambient conditions Ambient and storage temperature Standard range: -40 +85 C Extended range (option): -40 +105 C 1) Climate class Cx (-40 +85 C, 5 % up to 95 % relative humidity) DIN EN 60 654-1 Maximum permissible humidity 100 % relative humidity, moisture condensation permissible DIN EN 60068-2-30 Var. 2 Vibration 10 2000 Hz 10 g DIN EN 60 068-2-6 Shock DIN EN 60 068-2-27 Salt fog DIN EN 60 068-2-11 Special features Temperature units Configurable: C, F, K Resistance-sensor Linear resistance-sensors are connectable Sensor connection Configurable: 3 wire or 2 wire configurable compensation of lead resistance with 2 wire connection Info data TAG-No., Descriptor and Message via configuration storeable into transmitter Configuration and calibration data Permanently stored in EEPROM Case Head mounting design, incl. spring-loaded mounting screws Material Plastic, PBT, glass fibre reinforced Ingress protection case IP 66/67 IEC 529 / EN 60 529 terminal connections IP 00 IEC 529 / EN 60 529 Cross section of terminal connectors 0.14 1.5 mm² Weight Approx. 0.04 kg Dimensions See drawings 1) -40... +105 øc only without Ex-protection Page 3 of 8

Possible combinations of initial value of measuring range / end of measuring range The end of measuring range is dependent upon the respective initial value of measuring range. This is shown in the diagram below. The configuration software checks the desired measuring range. Only permissible values are accepted. Intermediate values are configurable, the smallest resolution is 0.1 C. Diagram for measuring ranges Model T24.10.1Px Range of possible end of measuring range in C -200-100 0 +100 +200 +300 +400 +500 +600 +700 +800 Measuring range in C minimum maximum -150 C -100 C -50 C -40 C 0 C +10 C +20 C +50 C +100 C +150 C initial value of measuring range -150... +380-150... +850-100... +180-100... +850-50... -20-50... +850-40... -20-40... +850 0... +20 0... +850 +10... +30 +10... +850 +20... +50 +20... +850 +50... +230 +50... +850 +100... +530 +100... +850 +150... +830 +150... +850 Diagram for measuring ranges Model T24.10.2Px Range of possible end of measuring range in C -200-100 0 +100 +200 +300 +400 +500 +600 +700 +800 Measuring range in C minimum maximum -200 C -150 C -100 C -50 C 0 C +50 C +100 C +150 C +200 C initial value of measuring range -200... +350-200... +850-150... +150-150... +850-100... -50-100... +850-50... 0-50... +850 0... +50 0... +850 +50... +100 +50... +850 +100... +150 +100... +850 +150... +450 +150... +850 +200... +750 +200... +850 Page 4 of 8

Dimensions in mm 2363092.01 Designation of terminal connectors RTD / resistance-sensor input 4 20 ma - loop 2363122.01 3 wire 2 wire Connection of Programming Unit Power supply unit Disconnect 2363114.01 Input yellow * green * red black Transmitter Yellow* and green* are connected only if configuration of the transmitter is to be made when the transmitter is on-line. When configuring in the workshop, an external power supply is not required as the Programming Unit provides the power. Page 5 of 8

Accessory Configuration-Set B @? C A B? Programming Unit for the connection to a Windows PC, incl. 9 V battery @ Connection cable, RS 232-C (9 - pin sub - D - plug) A Plug adapter (9 - pin / 25 - pin plug) B Two additional connection cables Programming Unit Transmitter C Configuration Software WIKA_TT (3.5 " disk, multi-lingual, Online Help) (free of charge download from the WIKA Homepage www.wika.de) Starter Kit Accessory (please order separately) Order No. Configuration-Set for T12 and T24 36 34842 Configuration Software T24 on 3.5" disk 1) 23 75385 Starter Kit, consisting of T24 + Configuration-Set 24 10813 1) Free of charge download from the WIKA Homepage www. wika.de Page 6 of 8

Assembly accessories Field case Adapter, plastic/stainless steel 3224741.01 3301732.01 Adapter, steel tin galvanized Adapter, steel zinc galvanized 3222438.01 2385789.01 Accessory (please order separately) Order No. Field case, plastic (ABS), IP 65, for mounting of a head mounting transmitter, permissible ambient temperature: -40 C... +80 C, 82x80x55 mm (WxLxH), with two cable glands M16x1.5 33 01732 Adapter for mounting on a DIN rail, plastic/stainless steel 35 93789 Adapter for mounting on a DIN rail, steel tin galvanized 36 19851 Adapter for mounting on a DIN rail, steel zinc galvanized 23 73633 Page 7 of 8

Ordering information Field No. Code Features Input 1P resistance thermometer Pt 100, small measuring ranges (minimum span 20 K) 1 2P resistance thermometer Pt 100, large measuring ranges (minimum span 50 K) Explosion protection 0 without 2 II 1G EEx ia IIC T4/T5/T6 acc. Directive 94/9/EG (ATEX) 6 CSA Class I, Division 1, Group A, B, C, D 8 FM Class I, Division 1, Group A, B, C, D 2 9 II 3G EEx nl/na IIC T4/T5/T6 Approvals Z without 3 G GL-Approval Ambient temperature F -40... +85 C (-40... +185 F) 4 H extended range: -40 C... +105 C not with explosion protection Measuring range GK basic configuration (3 wire, 0...150 C, signalling down scale < 3.6 ma) 5 KL customer s specification 1) Additional order info YES NO 6 T Z additional text Please state as clearly understandable text! 1) Please use sheet " Help to Order " of the price list, when ordering temperature transmitter configured to customer s specification. Order code: 1 2 3 4 5 6 T24.10 - - - - Additional text: Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. Page 8 of 8 9078029 10/2005 GB WIKA Alexander Wiegand GmbH & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Phone (+49) 93 72/132-0 Fax (+49) 93 72/132-406 E-Mail info@wika.de www.wika.de