Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

Similar documents
Differential Amplifier : input. resistance. Differential amplifiers are widely used in engineering instrumentation

Instrumentation amplifier

Electrocardiogram (ECG)

Used to overcome ventricular fibrillation may be due to coronary occlusion, shock, or abnormalities in blood chemistry

BIOMEDICAL INSTRUMENTATION PROBLEM SHEET 1

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences

Lecture 4 Biopotential Amplifiers

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.

AN4995 Application note

TRANSDUCER INTERFACE APPLICATIONS

Massachusetts Institute of Technology MIT

Special-Purpose Operational Amplifier Circuits

*Notebook is excluded

Dimensions in inches (mm) .268 (6.81).255 (6.48) .390 (9.91).379 (9.63) .045 (1.14).030 (.76) 4 Typ. Figure 1. Typical application circuit.

EE 230 Experiment 10 ECG Measurements Spring 2010

LINEAR IC APPLICATIONS

Bio-Potential Amplifiers

Dimensions in inches (mm) .021 (0.527).035 (0.889) .016 (.406).020 (.508 ) .280 (7.112).330 (8.382) Figure 1. Typical application circuit.

EECS 145L Final Examination Solutions (Fall 2013)

Biomedical Instrumentation (BME420 ) Chapter 6: Biopotential Amplifiers John G. Webster 4 th Edition

Biomedical. Measurement and Design ELEC4623. Lectures 9 and 10 Practical biopotential amplifier design and multilead ECG systems

Homework Assignment 03

Lab E5: Filters and Complex Impedance

SIGNAL RECOVERY: Sensors, Signals, Noise and Information Recovery

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Chapter 4. Pulse Echo Imaging. where: d = distance v = velocity t = time

Concepts to be Reviewed

Kanchan S. Shrikhande. Department of Instrumentation Engineering, Vivekanand Education Society s Institute of.

* Notebook is excluded. Features KL-720 contains nine modules, including Electrocardiogram Measurement, E lectromyogram Measurement,

MECE 3320 Measurements & Instrumentation. Data Acquisition

SGM MHz, 48μA, Rail-to-Rail I/O CMOS Operational Amplifier

Ballistocardiograph 1

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13

AD8232 EVALUATION BOARD DOCUMENTATION

Interface Electronic Circuits

Biomedical. Measurement and Design ELEC4623/ELEC9734. Electrical Safety and Performance Standards

Florida Atlantic University Biomedical Signal Processing Lab Experiment 2 Signal Transduction: Building an analog Electrocardiogram (ECG)

LMC6081 Precision CMOS Single Operational Amplifier

ELG3336 Design of Mechatronics System

3. Ultrasound Imaging(2)

Electrical noise in the OR

6 db Differential Line Receiver

Laboratory Activities Handbook

E40M. Instrumentation Amps and Noise. M. Horowitz, J. Plummer, R. Howe 1

12/26/2017. Alberto Ardon M.D.

EE 3305 Lab I Revised July 18, 2003

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

STRAIN, FORCE, PRESSURE, AND FLOW MEASUREMENTS

Lecture Notes Unit-III

OBSOLETE. High Performance, BiFET Operational Amplifiers AD542/AD544/AD547 REV. B

Op-Amp Simulation Part II

NeuVision 500. Abundant and friendly display interface, multifold ECG display screen:

EPAD OPERATIONAL AMPLIFIER

Ultra-Low Bias Current Difet OPERATIONAL AMPLIFIER

Integrated Dual-Axis Gyro IDG-1215

NE/SA5234 Matched quad high-performance low-voltage operational amplifier

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

DUAL ULTRA MICROPOWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER

Analog Circuits Part 3 Operational Amplifiers

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument

Advanced Measurements

High Common-Mode Rejection. Differential Line Receiver SSM2141 REV. B FUNCTIONAL BLOCK DIAGRAM FEATURES. High Common-Mode Rejection

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล

Low Cost, General Purpose High Speed JFET Amplifier AD825

ECE 480 Design Team 6 Electrocardiography and Design

CHAPTER 3. Instrumentation Amplifier (IA) Background. 3.1 Introduction. 3.2 Instrumentation Amplifier Architecture and Configurations

IFB270 Advanced Electronic Circuits

Development of Electrocardiograph Monitoring System

IMPROVEMENTS IN ELECTROCARDIOGRAPHY SMOOTHENING AND AMPLIFICATION

EKT 314 ELECTRONIC INSTRUMENTATION

BME 701 Lecture 1. Measurement and Instrumentation

User s Manual For: Harvard s Research DC Signal Conditioner With Zero Suppression Catalog No

Medlab GmbH EG05000 User Manual. medlab. Five Lead ECG OEM board EG Technical Manual. Copyright Medlab Version Version 1.

Analog Electronics. Lecture Pearson Education. Upper Saddle River, NJ, All rights reserved.

Fiber Optic Communications Communication Systems

High Common-Mode Voltage Difference Amplifier AD629

Fig. 1

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

Design on Electrocardiosignal Detection Sensor

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

DRG-SC Series Signal Conditioners


Department of Electrical Engineering and Computer Science


High Speed FET-Input INSTRUMENTATION AMPLIFIER

User s Manual for Integrator Short Pulse ISP16 10JUN2016

Electronics basics for MEMS and Microsensors course

Electronic Buzzer for Blind

The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

Technology. Construction of magnetic buzzer. Construction of magnetic buzzer. Operation principles and construction

Active Vibration Isolation of an Unbalanced Machine Tool Spindle

Analog Circuits and Systems

Signal Conditioning Devices


OBSOLETE. Self-Contained Audio Preamplifier SSM2017 REV. B

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

Medlab GmbH EG04000 User Manual. medlab. Four Lead ECG OEM board EG Technical Manual. Copyright Medlab Version Version 1.

Transcription:

Benha University June 2013 Benha Faculty of Engineering Electrical Department Hospital Instrumentations (E472) 4 Th year (control) Dr.Waleed Abdel Aziz Salem Time: 3 Hrs Answer the following questions. Ques on (1): Complete (Write the answer only) [10 Marks] a) The five electrodes used to make 12 lead ECG recording are connected to the patient's right arm, left arm, right leg, left leg, and Chest. b) The frequency response of diagnostic ECG machine is from.05 to100 Hz. c) Defibrillator protection in the input of bioelectric amplifiers uses Glow lamps, followed by series resistors and Zener diodes. d) The frequency of an ultrasound signal in tissue is 19.7 MHz, if its velocity is 1500 m/s and the wavelength is 7.6х10-3 cm. e) The EEG peak to peak signal amplitude is 1 to 100 µv & frequency range is 0.5 to 100 Hz. Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Page 1 of 7

SA node firing triggers the pacemaker Delays are used to simulate natural delay from SA to AV node (120ms) and to create a refractory period (500ms) Output circuit controls ventricular contraction Combining the demand pacemaker with this design allows the device to let natural SA node firing to control the cardiac activity b) Draw the blood pressure pulse excitation amplifier circuit and explain its operation. 1- the excitation signal is a biphasic short duration pulse (duration on 1ms) 2- A1 is a dc pressure amplifier & A2 is a unity gain summation stage 3- Switches S1 to S5 are CMOS electronic switches which close when control line is high 4- All circuit action is controlled by 4 phases -phase Φ1 & Φ2 excite the transducer & operate the drift cancellation (offset volt due to thermal changes) - Φ3 update the display meter - Φ1 reset the circuit 5- the transducer is excited only when Φ1 is high and Φ2 is low at all other times the transducer is not excited c) Explain the function for each part of ultrasound transducer construction. 1- Piezoelectric Element change in shape of the crystal increases and decreases the pressure in front of the transducer, thus producing ultrasound waves When the crystal is subjected to pressure changes by the returning ultrasound echoes, the pressure changes are converted back into electrical energy signals 2- Damping Block composed of epoxy resin impregnated with tungsten bonded to the back of the elements to reduce the # of cycles in the pulse Page 2 of 7

-The damping block absorbs the backward directed ultrasound energy and attenuates stray ultrasound signals from the housing -It also dampens (ring-down) the transducer vibration to create an ultrasound pulse with a short spatial pulse length, which is necessary to preserve detail along the beam axis (axial resolution) 3- Matching Layer A matching layer of material is placed on the front surface of the transducer to improve the efficiency of energy transmission into the patient 4- Insulating Case Plastic or metal casing around transducer Protects: Keeps outside interference/electrical noise from entering Protects the transducer s components 5- Wiring Carries electrical pulse to the crystal Transmits voltage from the receiving crystal back to the US unit d) Draw the block diagram of EEG and list the function of each block. The surface electrodes are used to measure the pretty weak α wave that is induced By stimulating the eye with light. If the eyes open or close, an arrhythmic α wave will show up Pre-amplifier with a gain of 50 is used as the preamplifier for picking up the unipolar component of EEG signals. The band-reject filter is a filter for reject the un needed bandwidth. the isolation circuit is to isolate the signal and line power source, and can be Page 3 of 7

implemented by using either an optical or voltage-transformed method. The band-pass filter is a filter for a signal with bandwidth from 1 to 20 Hz.. The amplifier with an amplification factor of 1000 (max) can magnify the weak signal that passes through the filter Question (3): Draw only [12 Marks] a) ESU protection circuit. b) The internal circuit design of automatic blood pressure measurement device with operational amplifier. Solved in the lecture c) The Block diagram of Entire ECG Circuit. Page 4 of 7

d) The beam profile of ultrasound transducer & write the equations for each field and angle. Near Field: Far Field: d d> D2 4λ D2 4λ Beam spreading angle: θ = 1.2λ D Page 5 of 7

Question (4): [10 Marks] 1) The voltage pulse delivered to defibrillator paddles attached to a patient is given in the shown figure. The thorax resistance RT= 50 Ω, what must be the skin-electrode resistance in order that 110 J of energy will be delivered to the thorax of the patient? Assume that R D = 10 Ω. Solved exactly in the sheet 2) For the circuit in Fig. (1), if the whetstone bridge excitation voltage equal 12 volt, pressure sensor resistance R1=20 Ω, R2=R4= 1000Ω, R3= 100 Ω and the selected pressure range at 300 mmhg, determine the output circuit voltage & determine the setting voltage (Vof) of the zero adjustment potentiometer to compensate for -2 V offset voltage at the input. (Set the value of the gain potentiometer to 70 kω). Solved exactly in the lecture Question (5): For the circuit in Fig. (2): [10 Marks] a) Explain the function of the circuit. ECG amplifier with common mode voltage cancelation via right leg driven and dc offset voltage cancelation via the use of a DC restorator. b) Calculate the gain values for the buffers stage, differential amplifier stage,the out Amplifier stage and Cutoff Freq. of the filter. Stage 1 V1=(1+(2*100,000/20,000))= 11 Stage 2 V2=( 50,000/50,000)=1 Stage 3 V3=(1+(25,000/510)=50 Total Gain=V1*V2*V3=11*50*1= 550 Diagnostic Mode (most time) where RC = 1x10-6 F*3.2x10 6 Ώ = 3.2 sec Cutoff Freq = 1/(2πRC) = 0.05Hz Monitor Mode (medium time) where RC = 1x10-6 F*318x10 3 Ώ = 0.318 sec Cutoff Freq = 1/(2πRC) = 0.5Hz Quick Restore (least time) where RC = 1x10-6 F*80x10 3 Ώ = 0.08 sec Cutoff Freq = 1/(2πRC) = 2Hz c) Draw the output voltage if the input was 1 mvp-p ECG wave form + 300 mv dc offset. [Mention the effect of using the integrator A5] The 300 mv dc offset voltage is canceled via the dc restorator and the 1 mv will be amplified with the gain of 550 (which is the total gain of the circuit) and give an output of 500 mv (0.55 V) peak-to-peak. Page 6 of 7

Page 7 of 7