User Manual. All rights reserved. Specifications are subject to change without notice.

Similar documents
User Manual. All rights reserved. Specifications are subject to change without notice.

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

UT207A/208A/209A Operating Manual. Table of Contents

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

User Manual Digital Multimeter. model no.: MSR-U1000

312, 316, 318. Clamp Meter. Users Manual

KMD-S04 Multímetro de bolsillo

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

DVM1190 DIGITAL MULTIMETER

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

400Amp True RMS AC/DC Clamp Meter Model EX613

OPERATOR S INSTRUCTION MANUAL

USER'S MANUAL DMR-6700

Pocket Size Digital Multimeter with USB Model: A & A

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Digital Multimeter, Pen Type

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

DM-45 Digital Multimeter

Sales: Technical: Fax:

DCM730. Digital Clamp Meter User s Manual

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Model UT10A: OPERATING MANUAL Table of Contents (1)

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

The Meter Structure The Figure 2-1 shows the Meter structure.

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Electrical Multimeter

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

True RMS Digital Multimeter Model:

Analog Technologies. Multimeter 15B and17b

MODEL: D03128 CLAMP METER

Digital Clamp Meter Model: &

MS2109A AC/DC Clamp Meter. User Manual. Contents

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

DIGITAL MULTIMETER AUTORANGING

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Electrical Multimeter

Table of Contents GDM-356. Page

15B & 17B. Users Manual. Multimeters

User Manual Digital Clamp Multimeter. model no.: MSR-C600

15B & 17B. Multimeters. Users Manual

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

DMM8900 SERIES USERS MANUAL

VC835 DIGTAL MULTIMETER Operation Manual

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

AMM-1022 Digital Multimeter USER`S MANUAL

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

200Amp AC Clamp Meter + NCV Model MA250

USER S MANUAL DMR-1500

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Model A/ A: OPERATING MANUAL TABLE OF CONTENTS

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

ProfiScale MULTI Multimeter

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

902 FC. HVAC True-rms Clamp Meter

AC/DC CLAMP METER USER S MANUAL

Handheld Digital Multimeter

1.General instructions Specifications Description...7

400Amp True RMS AC Clamp Meter + NCV

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Model: &

Mini Clamp Meter Model:

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

DDM350 Pen-Type Digital Multimeter User s Manual

User Guide. Digital AC/DC Clamp Meter Model 38394

Not for Reproduction

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

Compact MultiMeters + Voltage Detector

Model : OPERATING MANUAL Table of Contents (1)

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

Handheld Digital Multimeter

User s Guide. Digital AC/DC Clamp Meter Model 38394

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

AUTO RANGING DIGITAL MULTIMETER

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

INSTRUCTION MANUAL DIGITAL MULTIMETER

R/C SMD Tweezers Multimeter Model RC200

DIGITAL MULTIMETER INSTRUCTION MANUAL

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Handheld Digital Multimeter PRO-50A

Autoranging Multimeter Extech EX503

Analog Technologies VC99. Multimeter FEATURES

User s Guide. 400A AC/DC Clamp Meter. Model MA220

OS-81B TECPEL CO. LTD.

Model DIGITAL MULTIMETER

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

Transcription:

User Manual All rights reserved. Specifications are subject to change without notice.

LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty does not cover fuses, disposable batteries, damage from misuse accident, neglect, alteration, contamination, or abnormal conditions of operation or handling, including failures caused by use outside of the product's specifications, or normal wear and tear of mechanical components.

Table of Contents Page Introduction...1 Safety Information...1 Instrument Overview...3 LCD Display...3 Function Buttons...5 Input Terminals...8 Measurements Instruction...9 Measure AC/DC Voltage...9 Measure AC/DC Current...9 Measure Resistance...10 Test Diodes and Continuity...11 Measure Capacitance...11 Measure Frequency and Duty Cycle...12 Measure Temperature...13 Test NCV... 14

Maintenance...15 Clean the Product...15 Replace the Batteries...15 Replace the Fuses...16 Specifications...17 General Specifications...17 Mechanical Specifications...17 Environmental Specifications...17 Electrical Specifications...18

Introduction This product is a 9999 counts true RMS autoranging digital multimeter. It is operated all by buttons with a triple display. Safety Information To avoid possible electrical shock, fire, or personal injury, please read all safety information before you use the product. Please use the product only as specified, or the protection supplied by the product can be compromised. Examine the case before you use the product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals. The measurement must be made with correct input terminals and functions and within the allowable measuring range. Do not use the product around explosive gas, vapor, or in damp or wet environments. 1

Keep fingers behind the finger guards on the probes. When the product has already been connected to the line being measured, do NOT touch the input terminal that is not in service. Disconnect the test leads from the circuit before changing the mode. When the voltage to be measured exceeds 36V DC or 25V AC, the operator shall be careful enough to avoid electric shock. Misuse of mode or range can lead to hazards, be cautious. will be shown on the display when the input is out of range. Low level of a battery will result in incorrect readings. Change the batteries when battery level is low. Do not make measurements when the battery door is not properly placed. 2

Instrument Overview LCD Display 1 2 3 4567 8 24 23 2221 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 20 19 18 Auto range. The product selects the range with the best resolution. Manual range. The user selects the range. Display shows maximum reading. Relative mode. Diode test. Continuity test. Display shows minimum reading. Secondary measurements display. Duty cycle test. Capacitance test. (Farad) 3 17 16 15 14

11 12 13 14 15 16 17 18 19 20 21222324 Frequency test. (Hertz) Temperature test. (Celsius) Temperature test. (Fahrenheit) Analog bar graph. Resistance test. (Ohm) Current test. (Ampere) Voltage test. (Volt) Primary measurement display. The product measures both sinusoidal and nonsinusoidal ac waveforms accurately. Low battery. Replace batteries. Negative readings. Alternating current. Direct current. Display freezes present reading. Measurement units. 4

Function Buttons 1 3 2 6 4 5 7 1 Push for more than 2 seconds to turn on/off the product. The product automatically powers off after 5 minutes of inactivity. The built-in beeper beeps 5 times 1 minute before auto power off. To disable the Auto Power Off function, hold down while turning on the product, you will hear five beeps if you have successfully disabled the function. Push to toggle between DCA/ACA when the red test lead is plugging in the terminals to test current. 5

2 3 4 5 6 Push once to hold the current reading on the display; push again to continue normal operation. Push for more than 2 seconds to enter the relative mode. The product will store the present reading as a reference for subsequent readings. The display is zeroed, and the stored reading is subtracted from all subsequent readings. Longpush again to exit the relative mode. Push this button to toggle between testing modes of DCV, ACV, and NCV. Push this button to toggle between testing modes of DCmV ( < 99.99mV), ACmV( < 99.99mV), and Temperature. Push this button to toggle between testing modes of Resistance, Diode/Continuity, and Capacitance. Push this button once to enter the manual range mode. In manual range mode, each push increases the range; when the highest range is reached, the next push will lead to the lowest range. To exit the manual range mode, push the button for more than 2 seconds. 6

7 Push this button when the product is at the setting of ACV, the primary measurement display will show the current frequency (1~100kHz) while the secondary measurement display will show the current duty cycle. Push this button when the product is at the setting of ACmV, the primary measurement display will show the current frequency (1~5MHz) while the secondary measurement display will show the current duty cycle. 7

Input Terminals A ma μa COM VΩHz Input terminal for AC/DC current measurements to 9.999A. Input terminal for AC/DC current measurements to 999.9μA. Common (return) terminal for all measurements. Input terminal for the measurements of: 1. AC/DC voltage 2. Resistance 3. Capacitance 4. Frequency 5. Temperature 6. Continuity 7. Diode 8. Duty cycle 8

Measurements Instruction Measure AC/DC Voltage 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. To measure voltage under 99.99mV, push, push once to measure DCmV, push twice to measure ACmV. To measure voltage higher than 99.99mV, push DCV, push twice to measure ACV., push once to measure 3. Touch the probes to the correct test points of the circuit to measure the voltage. 4. Read the measured voltage on the display. *Do not measure voltage that exceeds the extremes as indicated in the Specifications. *Do not touch high voltage circuit during measurements. Measure AC/DC Current 1. Connect the black test lead to the COM Terminal and the red lead to the AmA Terminal or the μa Terminal (choose based on the value of the current to be measured); if the previous setting was continuity/diode, push any of the three rectangle buttons on the left once. 9

2. Push to toggle between DCA and ACA. 3. Break the circuit path to be measured, connect the test leads across the break and apply power. 4. Read the measured current on the display. *Do not measure current that exceeds the extremes as indicated in the Specifications. *Use the AmA Terminal when you are measuring an unknown current. Then switch to the μa Terminal if necessary. *Do not input voltage at this setting. Measure Resistance 1. Connect the black test lead to the COM Terminal and the test lead to the VΩHz Terminal. 2. Push once to enter the Resistance Mode. 3. Touch the probes to the desired test points of the circuit to measure the resistance. 4. Read the measured resistance on the display. *Disconnect circuit power and discharge all capacitors before you test resistance. *Do not input voltage at this setting. 10

Test Diodes and Continuity 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. Push twice to enter the Diode/Continuity Mode. 3. To test continuity, touch the probes to the desired test points of the circuit. The built-in beeper will beep when there is a short circuit. 4. To test diodes, connect the red probe to the anode side and the black probe to the cathode side of the diode being tested. Then read the forward bias voltage value on the display. If the polarity of the test leads is reversed with diode polarity or the diode is broken, the display reading shows. *Do not input voltage at this setting. *Disconnect circuit power and discharge all capacitors before you test diode. Measure Capacitance 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 11

2. Push three times to enter the Capacitance Mode. 3. Connect the red probe to the anode side and the black probe to the cathode side of the capacitor being tested. 4. Read the measured capacitance value on the display once the reading is stablized. *Disconnect circuit power and discharge all capacitors before you test capacitance. Measure Frequency and Duty Cycle 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. When the frequency to be measured is 100kHz, push until the product is at the setting of ACV; touch the probes to the desired test points, and the secondary measurement display will show the frequency; then push, the primary measurement display will show frequency while the secondary measurement display will show the duty cycle. 12

3. When the frequency to be measured is between 100kHz and 500MHz, push twice to enter the ACmV Mode; touch the probes to the desired test points, and the secondary measurement display will show the frequency; then push, the primary measurement display will show frequency while the secondary measurement display will show the duty cycle. Measure Temperature 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. Push three times to enter the Temperature Mode. Both displays will show room temperature; the primary measurement display will show Celsius while the secondary measurement display will show Fahrenheit. 13

2. Touch the probes to the desired test points. 3. Read the measured temperature on the display. Test NCV 1. Push twice to enter the NCV Mode. 2. Hold the product and move it around, the builtin beeper will beep when the inner sensor detects AC voltage nearby. The stronger the voltage is, the quicker the beeper beeps. 14

Maintenance Beyond replacing batteries and fuses, do not attempt to repair or service the product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions. Clean the Product Wipe the product with a damp cloth and mild detergent. Do not use abrasives or solvents. Dirt or moisture in the terminals can affect readings. *Remove the input signals before you clean the product. Replace the Batteries When is shown on the display, batteries shall be replaced as below: 1. Remove the test leads and turn off the product before replacing the batteries. 15

2. Loosen the screw on the battery door and remove the battery door. 3. Replace the used batteries with new batteries of the same type. 4. Place the battery door back and fasten the screw. Replace the Fuses When a fuse is blown or do not work properly, it shall be replaced as below: 1. Remove the test leads and turn off the product before replacing the fuse. 2. Loosen the four screws on the back cover and the screw on the battery door, then remove the battery door and the back cover. 3. Replace the fuse with a new fuse of the same type. 4. Place the back cover and the battery door back and fasten the screws. 16

Specifications General Specifications Display(LCD) 9999 Counts Ranging Auto/Manual Material ABS+TPE Update Rate 3 Times/Second Ture RMS Data Hold Backlight Low Battery Indication Auto Power Off Mechanical Specifications Dimension 146*74*34mm Weight 125g Battery Type 1.5V AA Battery * 2 Warranty One year Environmental Specifications Operating Temperature 0~40 Humidity <75% Storage Temperature -20~60 Humidity <80% 17

Electrical Specifications Function Range Resolution Accuracy 999.9mV 0.1mV DC Voltage (V) 9.999V 0.001V 99.99V 0.01V 999.9V 0.1V ±(0.5%+3) DC Voltage (mv) 9.999mV 99.99mV 999.9mV 0.001mV 0.01mV 0.1mV AC Voltage (V) 9.999V 0.001V 99.99V 0.01V 750.0V 0.1V ±(1.0%+3) AC Voltage (mv) 9.999mV 99.99mV 0.001mV 0.01mV *Frequency response of ACV: 40Hz-1kHz 18

Function Range Resolution Accuracy DC Current (ma&a) DC Current (μa) AC Current (ma&a) AC Current (μa) 999.9mA 19 0.1mA 9.999A 0.001A 99.99μA 999.9μA 999.9mA 0.01μA 0.1μA 0.1mA 9.999A 0.001A 99.99μA 999.9μA 0.01μA 0.1μA ±(1.0%+3) ±(0.8%+3) ±(1.2%+3) ±(1.0%+3) Frequency response of AC Current: 40Hz-1kHz Resistance 99.99Ω 0.01Ω ±(1.0%+3) 999.9Ω 0.1Ω 9.999kΩ 99.99kΩ 999.9kΩ 0.001kΩ 0.01kΩ 0.1kΩ ±(0.5%+3) 9.999MΩ 0.001MΩ ±(1.5%+3) 99.99MΩ 0.01MΩ ±(3.0%+5)

Function Range Resolution Accuracy 9.999nF 0.001nF ±(5.0%+20) 99.99nF 0.01nF 999.9nF 0.1nF Capacitance 9.999μF 0.001μF ±(2.0%+5) 99.99μF 0.01μF 999.9μF 0.1μF 9.999mF 0.001mF ±(5.0%+5) 99.99Hz 0.01Hz Frequency (Measures only to 100kHz under the ACV setting) 999.9Hz 9.999kHz 99.99kHz 999.9kHz 0.1Hz 0.001kHz 0.01kHz 0.1kHz ±(0.1%+2) 5.000MHz 0.001MHz Duty Cycle 1%~99% 0.1% ±(0.1%+2) 20

Function Range Resolution Accuracy Temperature (-20~1000) 1 ±(2.5%+5) (-4~1832) 1 Diode Continuity NCV 21