SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Similar documents
SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES solenoid air pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4 to 1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2

GENERAL AIR OPERATED SPECIFICATIONS PILOT OPERATED SPECIFICATIONS. Series /8 = 3000 l/min 1/2 = 3800 l/min

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4 to 1/2

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid aluminium body, 1/4 to 1/2

SOLENOIDS, COILS & ACCESSORIES Product Index

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

24000, 3/2 Direct solenoid actuated direct poppet valves

2/2-Way Solenoid Control Valve

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

2-way pilot operated solenoid valves for water, hot water and steam

Resistance Thermometers Model Series TR7X0, Sheathed Design

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

DPharp Differential Pressure and Pressure Transmitters

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

Products catalogue (I-P Edition)

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

IP26 Series Current to Pneumatic Converter

FAS 10 mm PICOSOL Direct acting solenoid valve

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE

Design and applications

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg.

Resistance thermometers for process technology

Rod probe With coaxial tube reference probe

Target disk flowmeter for liquids and gases

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Directional valves Electrically operated Series 563, 565, 567. Brochure

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

SALES SERVICE +358 (0)

Precision Junction Boxes

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Digital flow ELEMENT transmitter for continuous flow measurement

Insertion Flow sensor for continuous flow measurement

Precision Junction Boxes

F780HD, 3, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

VITO LT. Global Experience. Locally Applied. A dependable choice.

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

Digital flow ELEMENT transmitter for continuous flow measurement

EN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D

4CONTROL VALVES CONTROL VALVES ULTRAFLO BUTTERFLY VALVES 522 SERIES NEW! H2X E2X KMSC-0 SPECIFICATIONS

B350L, 3-Way, Diverting Ball Valve Chrome Plated Brass Ball and Nickel Plated Brass Stem

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

PAD - Heavy Duty Differential Pressure Trasmitter

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Digital inductive conductivity transmitter

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Field indicator for current loops with HART communication Models DIH50, DIH52

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

ED701 General Industry Pressure Transmitter

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd

NEW. 7321B 7322B Series. 2-way pilot operated solenoid valves for water, hot water and steam

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

INLINE flowmeter for continuous flow measurement

Digital flow transmitter for continuous flow measurement

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Electromagnetic flowmeters and switches DWM 1000/2000

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

OPTIWAVE 7300 C Supplementary instructions

Power supply. Calibration. Surface finishing. Seal. Process connection

Process Protection Acoustic sensors for pump monitoring

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

CombiTemp TCR6 Standard RTD temperature sensor

Resistance thermometer Model TR30, compact design

INSERTION paddle wheel flowmeter for continuous flow measurement

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

General Specifications

Resistance thermometer Model TR30, compact design

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1

INSTRUCTION MANUAL (ATEX / IECEx)

Technical Data. General specifications. Rated operating distance s n 3 mm

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

KFS. Flap-type flow meter. Design and range of application

SATRON VB Pressure Transmitter

Transcription:

FETURES The monostable spool valves have TÜV certified IE 60 Functional Safety data and can be used up to SIL 4 ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) an be externally piloted (external air pilot supply) to convert valve to zero minimum operation by flipping a gasket The solenoid valves satisfy all relevant E Directives GENERL Differential pressure Flow (Qv at 6 bar) SOLENOID VLVES pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 2-0 bar [ bar =00 kpa] 60 l/min (NR) fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, filtered - 40 to + 60 VMQ (silicone) + PUR (polyurethane) 4 2 4 2 /2 Series MTERILS IN ONTT WITH FLUID ( ) Ensure that the compatibility of the fluids in contact with the materials is verified ody, end covers rass Spool valve internal parts rass, stainless steel, POM ore tube Stainless steel ore and plugnut Stainless steel ore spring Stainless steel Seals & discs NR Top disc P Disc holder POM artridge (low power) Welded, packless ISI 40 Seat rass Seat insert POM Shading coil opper Rider ring (low power) PTFE P RP-MP LP UP Not vailable 0,4W - 2W Not vailable 0,W -,2W Ultra Low power Low power Reduced and Medium power asic power POWER LEVELS - cold electrical holding values (watt) SPEIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) optional solenoids power max. (PS) level NEM TEX / IEEx min. (2) basic catalogue number IP6 air ( ) 7 & Ex d Ex emb Ex mb Ex ia EEx n ( ) (mm) (m /h) (l/min) ~ = ~/= EF LPKF NF EM PV LI IS ZN S Solenoid air pilot operated - spring return (monostable) /4 6 0,7 2, 0 / 2 0 0 P - - - - - 4 () /4 6 0,7 2, 0 / 2 0 0 P - - - - - - - - - G4 () /4 6 0,7 2, 0 / 2 0 0 LP - m - m m m m () /4 6 0,7 2, 0 / 2 0 0 LP m - - - - - - - - - G () Solenoid air pilot operated and return (bistable) /4 6 0,7 2, 0 / 2 0 0 P - - - - - 420 /4 6 0,7 2, 0 / 2 0 0 P - - - - - - - - - G420 /4 6 0,7 2, 0 / 2 0 0 LP - m - m m m m 20 /4 6 0,7 2, 0 / 2 0 0 LP m - - - - - - - - - G20 Select for NPT NSI.20. or select G for ISO G (22/) vailable feature vailable feature in D only. () ertified IE 60 Functional Safety data, use suffix "SL" (Not to use with LPKF suffix). (2) Zero minimum is only achieved if external pressure is applied. ll leaflets are available on: www.asco-process-scope.com PI---G 20/R0

SERIES PREFIX TLE power level description 2 4 6 7 LP RP MP P S D U Dustproof (EN 02--)* - - - E F Explosionproof - NEM 7, - Zinc plated steel conduit m - - E V Explosionproof - NEM 7, - 6 SS conduit m - - E M Waterproof IP67 - Metal enclosure (EN/IE 6007-7+, 624-)* - - E T Threaded conduit/hole (M20 x,) - - I S S Intrinsically safe with S coil (EN/IE 6007-+26, 624-)* m - - - L P K F Flameproof - luminium (EN/IE 6007-, 624-)* - - - N F Flameproof - luminium (EN/IE 6007-, 624-)* - - P V Encapsulated epoxy moulded (EN/IE 6007-, 624-)* m - - S Solenoid with spade plug connector (EN/IE 6070) - - W P Waterproof IP67 - Metal enclosure - - W P D U Waterproof IP67 - Metal enclosure, Dustproof (EN 02--)* - - - L I I.S. with luminium IP67 enclosure (EN/IE 6007- / 624-)* m - - - W P I S I.S. with Metal IP67 enclosure (EN/IE 6007-+26, 624-)* m - - - W S Waterproof IP67-6 SS enclosure - - W S D U Waterproof IP67-6 SS enclosure, Dustproof (EN 02--)* - - - W S L P K F Flameproof - 6 SS (EN/IE 6007-, 624-)* - - - W S E M Waterproof IP67-6 SS enclosure (EN/IE 6007-7+, 624-)* - - W S L I I.S. with 6L SS IP67 enclosure (EN/IE 6007-, 624-)* m - - - W S I S I.S. with 6 SS IP67 enclosure (EN/IE 6007-+26, 624-)* m - - - W S N F Flameproof - 6 SS (EN/IE 6007-, 624-)* - - Z N Moulded enclosure (EN 002, 02--)* m - - T Threaded conduit (/2" NPT) - - H T lass H - High temperature, +0 ambient temp. - - - X Other special constructions - - SUFFIX TLE suffix power level description 2 4 6 7 LP RP MP P M O Push type manual operator / - - S L ertified IE 60 Functional Safety data (2) / - - PRODUT SELETION GUIDE STEP Select the fluid temperature range and seal material from the general table on page. Select basic catalogue number, including pipe thread identification letter. Refer to the specifications table above. Example : G4 STEP 2 Select (combination). Select the appropriate operator from the specifications table on page and the table on page 2. Select for this operator in the electrical characteristics table on page : the power level (LP, P), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. Example : EM STEP Select suffix (combination) if required. Example : MO STEP 4 Select voltage. Refer to standard voltages on page. Example : 20V / 0Hz OPTIONS & ESSORIES series pipe exhaust protector (stainless steel) G / 46004 () NPT / 460042 () G /4 46004 () NPT /4 46004 () M 460044 () vailable feature m vailable feature in D only - Not available * TEX solenoids are also approved according to EN 46- (non electrical valves) () Provided with "SL" suffix (2) Not to use with MO suffix ORDERING EXMPLES: () pipe thread basic number () STEP Final catalogue / ordering number. Example : EM G4MO 20 V / 0 Hz S G 0V / 0 Hz S G 4 SL 20V / 0 Hz S G 420 MO 20V / 0 Hz SHT 420 MO 20V / 0 Hz ISS G 420 MO 24V / D WSLPKF G MO 24V / D LPKF G MO 24V / D LI G 24V / D WSLI G 20 MO 24V / D WPIS G 24V / D EM 4 MO 20V / 0 Hz EF G G 4 MO 240V / 60 Hz voltage suffix () Prefixes EF and EV should always be used with the letter G in the basic number. ll leaflets are available on: www.asco-process-scope.com --2 20/R0

EXPLNTION OF TEMPERTURE RNGES OF SOLENOID VLVES SERIES Valve temperature range The valve temperature range (TS) is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) Operator ambient temperature range The operator ambient temperature range is determined by the selected power level and the safety code Total temperature range The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above ELETRIL HRTERISTIS oil insulation class F Electrical safety IE Standard voltages D (=) 24V - 4V (~) 24V - 4V - V - 20V () /0Hz; other voltages and 60Hz are available on request power ratings operator electrical ambient replacement coil / kit inrush holding hot/cold temperature enclosure safety code type option range (TS) protection (2) ~ ~ = ~ = (V) (V) (W) (W) ( ) () (EN 602) 20 V/0 Hz 24V/D asic power (P) S 2 0, /,2-40 to +7 EN 6070 IP6 moulded 40042-7 40042-42 0 SDU 2 0, /,2-40 to +7 IID IP6 T 200 (~)/ (=) IP6 moulded - (4) - (4) 0 WP/WS 2 0, /,2-40 to +7 EN 6070 IP67 steel/ss 40040-7 40040-42 04 WPDU/WSDU 2 0, /,2-40 to +7 IID IP67 T 200 IP67 steel/ss - (4) - (4) 04 NF/WSNF 2 0, - (-60) (7) -40 to +2/40/60 II2G Ex d II T6/T/T4, II2D Ex td IP67 alum./ss 40040-7 - 02 NF/WSNF - - - /,2 (-60) (7) -40 to +40/60/7 II2G Ex d II T6/T/T4, II2D Ex td IP67 alum./ss - 40040-42 02 EM/WSEM 2 0, /,2-40 to +40 II2G Ex e mb II T, II2D Ex td IP67 steel/ss 4000-7 400-42 04 PV 2 0, /,2-40 to +6 II2G Ex mb II T(~)/T4(=),II2D Ex md 2 IP67 moulded - (4) - (4) 0 EF/EV 2 0, /,2-40 to +4/40 NEM type 7 and NEM 4X 264-0 274-006 06 ZN 2 0, /,2-20 to +0 IIGD EEx n II T IP6 moulded - (4) - (4) 0 Low power (LP) S,,,,7/,7-40 to +60 EN 6070 IP6 moulded 4002-07 4002-042 07 WP/WS,,,,7/,7-40 to +60 EN 6070 IP67 steel/ss 40026-07 40026-042 0 LPKF/WSLPKF () 2,,,4 0,/0, () -40 to +0/60 II2G Ex d II+H2 Gb T4/T6, II2D Ex t Db IP67 alum./ss - (4) - (4) NF/WSNF - -, - /, (-60) (7) -40 to +7/0 II2G Ex d II T6/T, II2D Ex td IP67 alum./ss - (4) () - (4) 0 EM/WSEM,,,,7/,7-40 to +40/ II2G Ex e mb II T6/T, II2D Ex td IP67 steel/ss - (4) - (4) 0 PV - - -,7/,7-40 to +6 II2G Ex mb II T6 / II2D Ex md 2 IP67 moulded - - (4) 0 EF/EV - - -,7/,7-40 to +60 NEM type 7 and NEM 4X - - (4) ISS () - - - 0,4/04-40 to +60 IIG Ex ia II T6, II2D Ex iad 2 IP6 moulded - 2676-00 2 LI () - - - 0,/0, -40 to +60 II2G Ex ib II Gb T6, II2D Ex t III Db IP67 alum. - - (4) 4 WSLI () - - - 0,/0, -40 to +60 IIG Ex ia II Ga T6, II2D Ex t III Db IP67 SS - - (4) 4 WPIS/WSIS () - - - 0,4/04-40 to +60 IIG Ex ia II T6, II2D Ex iad 2 IP67 steel - 2600-00 0 ZN - - -,7/,7-20 to +0 IIGD EEx n II T IP6 moulded - - (4) 07 option safety parameters U I = (D) I I P I L I I (V) (m) (W) (H) (µf) Low power (LP) ISS 2 00, 0 0 WPIS/WSIS 2 00, 0 0 LI/WSLI 2 00, 0 0 ELETRIL ONNETIONS S, SDU, ZN, ISS WP, WS, EM, WSEM, WPDU, WSDU, WPIS, WSIS NF, WSNF, LPKF, WSLPKF PV LI, WSLI EF, EV DDITIONL OPTIONS () Temperature range can be limited by sealings (2) Refer to the dimensional drawings on pages: 4 to 7 () ISS/WPIS/WSIS/LI/WSLI: heck the electrical characteristics in the corresponding catalogue pages (4) Multiple coil kits are available under TEX/IEEx, contact us () (WS)NF: Low Power, 20 V does not exist. Maximum voltage in is V (6) LI/WSLI: Low Power, 24 V D only (7) The certified minimum temperature of this operator () LPKF/WSLPKF: 24 V D, max. ambient temp. +0, contact us (4 V D = 2, W) - Not available connection Spade plug connector with cable gland EN70-0 (ISO 4400) for cables with an outer diameter from 6 to 0 mm M20 cable gland for cables with an outer diameter from 7 to 2 mm. With an internal and external facility for an earthing or bonding conductor /2" NPT threaded cable entry. Enclosures are supplied without cable gland Moulded-in cable, standard length 2 m /2 cable gland for cables with an outer diameter from 6 to 2 mm. With an internal and external facility for an earthing or bonding conductor /2" NPT conduits, standard length cm Valves configured for external pilot air supply, TPL 2047 Other pipe threads are available on request Ex mb/md ( "PV") solenoid can be supplied with various cable lengths ompliance with "UL", "S" and other local approvals available on request /2" NPT ( "T") and M20 x. ( "ET") conduits (aluminium or 6 SS) available for steel solenoid housing INSTLLTION Multi language installation/maintenance instructions are included with each valve The solenoid valves can be mounted in any position without affecting operation Do not connect the pressure supply to the exhaust port. The environmentally-protected construction is not adapted for a distributing function or use in NO function. ontact us for functions available in specific versions IE 60 Functional Safety (suffix SL), allowable temperature range: -40 to +60. For probability of failure, contact us It is necessary to connect pipes or fittings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) Threaded pipe connection identifier is: = NPT (NSI.20.); G = G (ISO 22/) Prefix "NF/WSNF" enclosure is provided with a /2" NPT threaded entry hole, M20 x, ( "ET") is optional. oth are supplied without cable gland ll leaflets are available on: www.asco-process-scope.com -- 20/R0

SERIES DIMENSIONS (mm), WEIGHT (kg) ll types 4, / 6, 4 2 2 x /4 27, = 22 = 2 4 4 4, 2 mounting holes. mm dia.; Spotfacing: mm dia., depth mm TYPE 0: Prefixes S: IP6, ZN: II G/D, IP6, EEx n II, SDU: II D, IP6, T00 to 200 asic power Epoxy moulded IE / ISO 4400 TYPE 02: Ex d II NF / WSNF luminium; epoxy coated / ISI 6 SS EN/IE 6007- and EN/IE 624-4 / 420 4 / 420 6 G / 60 0 60 /2 NPT 2 D E 4 4 02 6 4 / 420 TYPE 04: WP / WS EM / WSEM WPDU / WSDU Steel; epoxy coated / ISI 6 SS IE / EN 6007-7/ and EN 624- / 4 60 2 20 ll leaflets are available on: www.asco-process-scope.com --4 20/R0

SERIES DIMENSIONS (mm), WEIGHT (kg) TYPE 0: PV Epoxy encapsulated EN/IE 6007- and EN/IE 624- TYPE 06: EF and EV: NEM type 7 and Epoxy encapsulated IS-6 NSI NOTE: applicable to solenoid only 4 / 420 G4 / G420 / / 60 60 D 46 E D 2 E / 20 TYPE 07: S and ZN Epoxy moulded IE / ISO 4400 EN 002 / 20 TYPE 0: NF / WSNF luminium; epoxy coated / ISI 6 SS EN/IE 6007- and EN/IE 624-6 / NPT 60 0 60 /2 NPT 2 D E 4 4 02 6 / 20 TYPE 0: WP / WS EM / WSEM WPIS / WSIS Steel; epoxy coated / ISI 6 SS IE / EN 6007-7///26 and EN 624-/ / 20 TYPE 0: PV Epoxy encapsulated EN/IE 6007- and EN/IE 624- / NPT 4 / NPT 60 60 2 20 D 46 E ll leaflets are available on: www.asco-process-scope.com -- 20/R0

SERIES DIMENSIONS (mm), WEIGHT (kg) H / G20 TYPE : Prefixes EF/EV: IS-6 NSI / NEM EF and EV: NEM type 7 and Epoxy encapsulated IS-6 NSI NOTE: applicable to solenoid only / / 20 TYPE 2: ISS Polypropylene moulded Epoxy moulded IE / EN 6007-/26 and EN/IE 624- / NPT 60 60 6 D 2 E D 67 E TYPE : LPKF / WSLPKF luminium, cataphorese black painting / ISI 6L SS EN/IE 6007- and EN/IE 624- TYPE 4: LI: II 2G Ex ia II Gb T6, II 2D Ex t III IP67 Db WSLI: II G Ex ia II Ga T6, II 2D Ex t III IP67 Db luminium, cataphorese black painting, ISI 6L SS IE and EN: 6007-, 624- / 20 / 20 M 2 M /2NPT 0 /2 NPT 60 60 6 0 6 26 ll leaflets are available on: www.asco-process-scope.com --6 20/R0

SERIES DIMENSIONS (mm), WEIGHT (kg) type option power level D E weight () monostable bistable 0 S / SDU / ZN basic power 44 2 02,7 22, 6,,2 2,2 02 NF basic power 70 26 4, - - 2,6 4,4 02 WSNF basic power 70 26 4, - -,,7 04 WP/WPDU/WS/WSDU/EM/WSEM basic power 60 26 0 - -,70 2,4 0 PV basic power 44 4 22, 67,, 2, 06 EF / EV basic power 44,, 22, 74,,40 2,2 07 S / ZN low power 44, 0, 22, 7,,67 2,7 0 NF low power 70 26 4, - - 2, 4, 0 WSNF low power 70 26 4, - -,, 0 WP / WS / EM / WSEM / WPIS / WSIS low power 60 26 02,2 - -,7 2,72 0 PV low power 44 4 00, 22, 67,,7 2,6 EF / EV low power 44, 00, 22, 74,, 2,2 2 ISS low power 4 7 24, 22,,,0 2,4 LPKF low power 204 - -,66 2,6 WSLPKF low power 204 - - 2,27,76 4 LI low power 204 - -,67 2,7 4 WSLI low power 204 - - 2,2,77 () Incl. coil(s) and connector(s) 2 Ex d certified cable gland (on request) Three-core cable, length 2 m 4 able gland for unarmoured cable with 7 to 2 mm dia. sheath 6 onnector rotatable by 0 increments (cable ø 6-0 mm) Push type or screw type manual operator, suffix MO External pilot air supply, / pipe 0 able gland for unarmoured cable with 6 to 2 mm dia. sheath onnectable pilot exhaust port Non-connectable pilot exhaust port ESSORIES ø4 / NPT ø4 /4 NPT / NPT 20 pilot exhaust protector part number 27640-00 pilot top exhaust low power (SO solenoid interface) Ø Ø M / /4 4, 0 exhaust protector (stainless steel) ll leaflets are available on: www.asco-process-scope.com --7 20/R0

SERIES ll leaflets are available on: www.asco-process-scope.com -- 20/R0

SPOOL VLVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 4 2 4 2 4 2 4 2 /2 Series FETURES The monostable spool valves have TÜV certified IE 60 Functional Safety data and can be used up to SIL 4 ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) The solenoid valves satisfy all relevant E Directives GENERL Differential pressure Flow (Qv at 6 bar) 2-0 bar [ bar =00 kpa] 60 l/min (NR) fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, filtered - 40 to + 60 (2) VMQ (silicone) + PUR (polyurethane) (2) -40 for air operated versions. MTERILS IN ONTT WITH FLUID ( ) Ensure that the compatibility of the fluids in contact with the materials is verified ir operated NOMO solenoid (pilot) interface ody, end covers rass, ISI 6L rass, ISI 6L Spool valve internal parts rass, stainless steel, POM rass, stainless steel, POM Seals NR NR Pilot internal parts - Size (E06.6.20N), refer to catalogue pages: 02 pilot (FS/FVT/FSIS) and 60 piezotronic pilot (PIS/PISIS) 2 4 IR OPERTED SPEIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) optional basic catalogue number max. (PS) min. air ( ) ( ) (mm) (m /h) (l/min) ~ = Pilot air operated - spring return (monostable) /4 6 0,7 2, 2 0 0 - () Pilot air operated and return (bistable) /4 6 0,7 2, 2 0 0-20 UP LP 0,00W-0,2W 0,W -,W Ultra Low power Low power RP-MP Not vailable Reduced and Medium power P Not vailable asic power POWER LEVELS - cold electrical holding values (watt) NOMO SOLENOID (PILOT) INTERFE SPEIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) power level optional solenoids basic catalogue number max. (PS) TEX / IEEx IP6 min. air ( ) Ex ia ( ) (mm) (m /h) (l/min) ~ = ~/= FSIS PISIS FS FVT PIS NOMO Solenoid air pilot operated - spring return (monostable) /4 6 0,7 2, 2 0 0 LP - - - () /4 6 0,7 2, 2 - LP m - - - - () /4 6 0,7 2, 2 UP - m - - () Solenoid air pilot operated and return (bistable) /4 6 0,7 2, 2 0 0 LP - - - 20 /4 6 0,7 2, 2 - LP m - - - - 20 /4 6 0,7 2, 2 UP - m - - 20 Select for NPT NSI.20. or select G for ISO G (22/) vailable feature vailable feature in D only. () ertified IE 60 Functional Safety data, use suffix "SL". ll leaflets are available on: www.asco-process-scope.com -- 20/R0

PREFIX TLE power level description 2 4 6 7 UP LP RP P F S Solenoid + spade plug DIN 460,,4 mm, industry standard (EN 6070) - - - F V T Solenoid with connection M2, LED + protection (EN 6070) - m - - F S I S Intrinsically safe,,4 mm, pilot 02; TEX (EN 6007 / 624) * - m - - P I S Solenoid, spade plug DIN 460,,4 mm, industry stand., TEX (EN 6070) - - - P I S I S Intrinsically safe, piezotronic 60 pilot, TEX (EN 6007/624) * m - - - SUFFIX TLE suffix power level description 2 4 6 7 UP LP RP P G D Non-electrical, GD c, construction safety, gas/dust (EN 46-) - - - - M S Screw type manual operator () - / - - M O Push type manual operator / / - - S L ertified IE 60 Functional Safety data () / / - - OPTIONS & ESSORIES series exhaust pipe protector (stainless steel) G /4 46004 (2) NPT /4 46004 (2) M 460044 (2) vailable feature m vailable feature in D only - Not available * TEX solenoids are also approved according to EN 46- (non electrical valves) () Not to use with "SL" suffix (2) Provided with "SL" suffix ORDERING EXMPLES: SERIES PRODUT SELETION GUIDE STEP Select the fluid temperature range and seal material from the general table on page. Select basic catalogue number, including pipe thread identification letter. Refer to the specifications tables on page. Example: G STEP 2 Select (combination). Select the appropriate operator from the tables on pages and 0. Select for this operator in the electrical characteristics table on page : the power level (UP, LP), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. Example : FS STEP Select suffix. Suffix MO mandatory for the pilot 02 (FSIS). Refer to the suffix table on page 0, respect the indicated power level. Example : MO STEP 4 Selection of TPL, on page, is mandatory for the 60 pilot (PISIS), 2 HV D (2 mw) and 24 HV D (2 mw). dd "X" between the "PISIS" and the basic catalogue number. STEP Select voltage. Refer to standard voltages on page. Example : 20V / 0Hz STEP 6 Final catalogue / ordering number. Example : FS GMO 20 V / 0 Hz FS G 20V / 0 Hz FS G SL 20V / 0 Hz FVT 20 MO 20V / 0 Hz PISIS G MO 6V / D PISIS G SLMO 6V / D PISIS X G 20 MS TPL20666 24HV / D G G GD G GDSL G 20 pipe thread basic number voltage TPL suffix ll leaflets are available on: www.asco-process-scope.com --0 20/R0

EXPLNTION OF TEMPERTURE RNGES OF SOLENOID VLVES Valve temperature range Operator ambient temperature range Total temperature range The valve temperature range (TS) is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) The operator ambient temperature range is determined by the selected power level and the safety code The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above ELETRIL HRTERISTIS oil insulation class F Electrical safety IE Standard voltages D (=) FS/ FVT: 24V FSIS: 2V - 24V ; PIS: 24V à 70V ; PISIS: 6V, V, 2V, 24V (~) FS: 24V - V - 20V/0Hz - Other voltages are available on request PIS: 24V to 70V power ratings operator electrical ambient replacement coil inrush holding hot/cold temperature enclosure safety code option range (TS) protection type ~ ~ = ~ = () (V) (V) (W) (W) ( ) (EN 602) - - Low power (LP) FS,4,2, /,2-2 to +60 EN 6070 moulded IP6 - - 0 FS 2, (6),6 (6), (6) - -2 to +60 EN 6070 moulded IP6 - - 0 FVT () - - -,/, -2 to +60 EN 6070 moulded IP67/IP6 - - 02 FSIS ()(4) - - - 0, -0 to +40/60 II G Ex ia II T6/T4, II D Ex iad 20 moulded IP6 - - 04 Ultra low power (UP) PIS - - - 0,007-0 to +60 - moulded IP6 - - 06 PISIS (2)() 6V - - - 0,00-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP6 - - 06 PISIS (2)() V - - - 0,022-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP6 - - 06 PISIS (2)() 2LV - - - 0,02-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP6 - - 06 PISIS (2)() 2HV - - - 0,02-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP6 - - 06 PISIS (2)() 2LV - - - 0,046-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP6 - - 06 PISIS (2)() 2HV - - - 0,2-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP6 - - 06 - Not available () Refer to the dimensional drawings on pages 2 and. (2) Piezotronic standards voltages: Prefix PISIS: 6 V D / mw V D / 22 mw 2L V D / 2 mw 2H V D / 2 mw 24L V D / 46 mw 24H V D / 2 mw Turn ON voltage U ON 6.. V 7,2.. 2 V 0,.. 6 V 0,.. 6 V 2,6.. 2 V 2,6.. 2 V Turn OFF voltage U OFF V,2 V, V, V V V Peak current 6 m 0 m 6, m, m 0 m 4 m Holding current 0, m 2, m m 2,7 m, m,2 m able + max. barrier resistances (R S + R ) 200 Ω max. 00 Ω max. 200 Ω max. 470 Ω max. 200 Ω max. 470 Ω max. safety parameters () Intrinsically safe pilots: heck the electrical characteristics in the corresponding catalogue pages (FSIS: option U I I I P I L I I = (D) (V) (m) (W) (H) (µf) Low power (LP) FSIS 2 00,6 0 0 Ultra low power (UP) PISIS 0 200 0, 0 0 02 pilot / PISIS: 60 pilot). (4) FSIS (02 pilot): 2 V : I (ON) min., with LED = m; U (ON) min.=, V; U (max.) recommended = 2 V; U (OFF) =, V; I (OFF) = 0 m 24 V : I (ON) min., with LED = 2 m; U (ON) min.= 6,4 V; U (max.) recommended = 2 V; U (OFF) =,7 V; I (OFF) = 7 m () Values for LED + protection. (6) : 20 V - Not available ELETRIL ONNETIONS connection Spade plug connector with cable gland DIN 460,,4 mm, industry standard, for cables with an outer diameter FS, FSIS, PIS, PISIS from 4 to 6 mm FVT M2 connection for M2 connector DDITIONL OPTIONS TPL numbers: TPL 2066: Piezotronic, PISIS, 2 HV (2 mw) TPL 20666: Piezotronic, PISIS, 24 HV (2 mw) TPL numbers: TPL 20674: LED and protection, FS - dd 0, W (D) and 0,4 W/V () Only available in 24 V /D and V Mounting on aluminium supply rail, /4 or /2 Other pipe threads are available on request INSTLLTION SERIES Installation/maintenance instructions are included with each valve The solenoid valves and air operated valves can be mounted in any position without affecting operation IE 60 Functional Safety (Suffix SL), allowable temperature range: -40 to +60. Probability of failure on demand, contact us It is necessary to connect pipes or fittings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) Threaded pipe connection identifier is: = NPT (NSI.20.); G = G (ISO 22/) Valves with suffix "SL" are provided with a specific exhaust protector ll leaflets are available on: www.asco-process-scope.com -- 20/R0

SERIES DIMENSIONS (mm), WEIGHT (kg) Type 0..06: NOMO (E06.6.20N) Type 07: ir operated 6,6 72,2 4 4 2 2, 4 2 4, 2 22 40, 7, x G/4 2 mounting holes. mm dia.; Spotfacing: mm dia., depth mm G/ 2 2, 4 2 0. 2 2 0 2 46 x G/4 27, 4 TYPE 0: FS 02 pilot Polyarylamide IE / DIN 460 TYPE 02: FVT 02 pilot Polyarylamide IE / connection M2 + LED and protection / 20 MS / 20MS / MO / 20MO 2 / 20 MS / 20MS / MO / 20MO 2 20 M 7 242 27,, 74,6 6 M 62 220 4, 27,,6 MO / 20MO TYPE 04: FSIS 02 pilot Polyarylamide IE / DIN 460 EN/IE 6007-/26 and EN/IE 624- MO / 20MO TYPE 06: PIS / PISIS Piezotronic pilot Polyamide IE / DIN 460 EN 6007-/26 and EN 624-2 4 60 7 M 20 4 2 7 242 ll leaflets are available on: www.asco-process-scope.com 27, M 7 242 20/R0 --2

SERIES DIMENSIONS (mm), WEIGHT (kg) TYPE 07: ir operated version No Use "SL", "GD" or "GDSL" suffix IP6 / II GD c / 20 onnector rotatable by 0 increments (cable 4-6 mm) type option power level weight () monostable bistable 0 FS low power 0,66,7 02 FVT low power 0,66,7 04 FSIS low power 0,7, 06 PIS / PISIS ultra low power 0,,4 07 - - 0,4,07 () Incl. connector(s), except FVT. ESSORIES 7, 2 onnector rotatable by 0 increments (cable 6-7 mm) Manual operator location onnectable pilot exhaust port 4 2 46 2 Ø Ø M - /4 4, - exhaust protector (stainless steel) ll leaflets are available on: www.asco-process-scope.com 20/R0 --