Masimo Corporation 40 Parker Irvine, California Tel Fax

Similar documents
Signal Extraction Technology

WRIST BAND PULSE OXIMETER

Principle of Pulse Oximeter. SpO2 = HbO2/ (HbO2+ Hb)*100% (1)

Pulse Oximetry. Principles of oximetry

An Advanced Architecture & Instrumentation for Developing the System of Monitoring a Vital Sign (Oxygen Saturation) of a Patient.

City, University of London Institutional Repository

D5.1 Report on the design of a fibre sensor based on NIRS

Sensors. CSE 666 Lecture Slides SUNY at Buffalo

The OXY100C outputs four signals simultaneously, as shown in this graph: O 2 Saturation (beat-by-beat, CH 1) Pulse Waveform (beat-by-beat, CH 5)

Design Considerations for Wrist- Wearable Heart Rate Monitors

A Technology Overview of the Nellcor OxiMax Pulse Oximetry System

(51) Int Cl.: A61B 5/00 ( ) G06F 17/00 ( )

MASIMO RADICAL 7 Signal Extraction Pulse CO-Oximeter

United States Court of Appeals for the Federal Circuit

PHYSIOLOGICAL SIGNALS AND VEHICLE PARAMETERS MONITORING SYSTEM FOR EMERGENCY PATIENT TRANSPORTATION

PhO 2. Smartphone based Blood Oxygen Level Measurement using Near-IR and RED Wave-guided Light

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( Pulse Oximetry: The story so far

E-health Project Examination: Introduction of an Applicable Pulse Oximeter

PHOTOPLETHYSMOGRAPHIC DETECTOR FOR PERIPHERAL PULSE REGISTRATION

(12) United States Patent

BENG 186B Principles of Bioinstrumentation. Week 7 Review. Solutions

Application Note (A12)

THE BENEFITS OF DSP LOCK-IN AMPLIFIERS

in the Computer Interpretation of Pulse Oximetry Data Farid U.Dowla, Paul G. Skolcowski and Richard R. Leach, Jr. Lawren= Livemre National Laboratoxy

DESIGN AND PROTOTYPING OF A MINIATURIZED SENSOR

SFH Photoplethysmography Sensor

PULSE OXIMETRY MODULE TO IMPLEMENT IN TEAM MONITOR OF VITAL SIGNS

Dash 3000, 4000 & 5000

(12) United States Patent (10) Patent No.: US 6,385,471 B1

NeuVision 500. Abundant and friendly display interface, multifold ECG display screen:

City, University of London Institutional Repository

GE Healthcare. Dash 2500 The standard of excellence for sub-acuity monitoring

P.O. Pro WIRELESS REFLECTANCE PULSE OXIMETER Design 2. December 1, 2004 Team # 3 James Hart Sofia Iddir Rob Mahar Naomi Thonakkaraparayil

Design of Wearable Pulse Oximeter Sensor Module for Capturing PPG Signals

8.2 IMAGE PROCESSING VERSUS IMAGE ANALYSIS Image processing: The collection of routines and

HIGH RESOLUTION HADAMARD TRANSFORM OXIMETRY. D. Barschdorff, E. Starke

lllllllllllllllllllllll llllllllllllllllllllllllllllllllllllllllllllllll

Health and Fitness Analog solution. Wenbin Zhu Medical BDM June, 2015

EQUIPMENT AND METHODS FOR WAVEGUIDE POWER MEASUREMENT IN MICROWAVE HEATING APPLICATIONS

OxSim Sp02 Simulator Operator's Manual

SMART LASER SENSORS SIMPLIFY TIRE AND RUBBER INSPECTION

Choosing and Using Photo Sensors

Target Echo Information Extraction

73 ASSignee: Neller tria Bennet Incorporated, Clinical Investigation-Evaluation of oxygen Saturation

INTEGRATION OF LOW COST SpO2 SENSOR IN A WEARABLE MONITOR

Next Generation Biometric Sensing in Wearable Devices

A Twenty-Four Hour Tele-Nursing System Using a Ring Sensor

EE105 Fall 2015 Microelectronic Devices and Circuits. Invention of Transistors

LWIR NUC Using an Uncooled Microbolometer Camera

EnviteC OEM compatible sensors The secure alternative in SpO 2 monitoring Choosing the right sensor is critical Modern health care practices a

Independent component analysis applied to pulse oximetry in the estimation of the arterial oxygen saturation (SpO2) - a comparative study

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

D500. Defibrillator/Monitor NIBP. Temperature 1. Temperature 2 IBP 1 IBP 2. Capnography. Integrated Thermal Printer LCD

Doppler in Obstetrics: book by K Nicolaides, G Rizzo, K Hecher. Chapter on Doppler ultrasound: principles and practice by Colin Deane

Design of the Pulse Oximetry Measurement Circuit and Its Sensing System Based On CMOS

Automatic Transcription of Monophonic Audio to MIDI

RD SET. Masimo Sensors. Maximising Patient Comfort Optimising Clinician Workflow Helping Hospitals Meet Their Green Initiatives

Pulse Oximetry Dave Hoff Roy Zhang Tad Stalter Mike Carlson

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 24. Optical Receivers-

EMC Amplifiers Going Beyond the Basics to Ensure Successful Immunity Tests

Keywords: Electronic Patch, Wireless Reflectance Pulse Oximetry, SpO2, Heart Rate, Body Temperature.

Design of Virtual Sphygmomanometer Based on LABVIEWComparison, Reflection, Biological assets, Accounting standard.

Application Note (A13)

ELR 4202C Project: Finger Pulse Display Module

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

RD SET. Masimo Sensors. Maximizing Patient Comfort Optimizing Clinician Workflow Helping Hospitals Meet Their Green Initiatives

fnirs Sensor Data Sheet

CHAPTER -15. Communication Systems

APPLICATION OF HEART PHOTOPLETHYSMOGRAPHY

Class #9: Experiment Diodes Part II: LEDs

MASSACHUSETTS INSTITUTE OF TECHNOLOGY LINCOLN LABORATORY 244 WOOD STREET LEXINGTON, MASSACHUSETTS

UNIT 8 : MTI AND PULSE DOPPLAR RADAR LECTURE 1

Local Oscillator Phase Noise and its effect on Receiver Performance C. John Grebenkemper

Hints. for making. Better. Spectrum Analyzer. Measurements. Application Note

6.111 Final Project Proposal HeartAware

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 20

Today most of engineers use oscilloscope as the preferred measurement tool of choice when it comes to debugging and analyzing switching power

Clinical evaluation of a novel adaptive algorithm for automated control of oxygen therapy in preterm infants on non-invasive respiratory support

Mathematical Techniques. for Mitigating Alarm Fatigue

Progress in Reducing Size and Cost of Trace Gas Analyzers Based on Tunable Diode Laser Absorption Spectroscopy

Step vs. Servo Selecting the Best

TEGAM Power Amplifiers Simplify PSRR Measurements

FIRST MEASUREMENTS FROM A NEW BROADBAND VIBROTHERMOGRAPHY MEASUREMENT SYSTEM

Intelligent Pillow for Heart Rate Monitor

Optical Power Meter Basics

225 Lock-in Amplifier

MR Advance Techniques. Flow Phenomena. Class II

NEURALNETWORK BASED CLASSIFICATION OF LASER-DOPPLER FLOWMETRY SIGNALS

Calibration of a Terrestrial Full Waveform Laser Scanner

DESIGN OF A PHOTOPLETHYSMOGRAPHY BASED PULSE RATE DETECTOR

Multiple Reference Clock Generator

Testing with Femtosecond Pulses

Infrared Illumination for Time-of-Flight Applications

Achieving high sensitivity at different scattering angles with different optical configurations

USING NIR MOISTURE SENSORS TO IMPROVE DRYER PERFORMANCE

PX8000 Precision Power Scope with Features of High-accuracy Power Meter and Waveform Measuring Instrument

Pulse-Width Modulation (PWM)

Enhanced Sample Rate Mode Measurement Precision

Small, Low Power, High Performance Magnetometers

APPENDIX E: IWX214 HARDWARE MANUAL

Transcription:

Instruments and sensors containing Masimo SET technology are identified with the Masimo SET logo. Look for the Masimo SET designation on both the sensors and monitors to ensure accurate pulse oximetry when needed most. Masimo Corporation 40 Parker Irvine, California 92618 Tel 949-297-7000 Fax 949-297-7001 www.masimo.com 7005-1035L-0105 2004 Masimo Corporation.All rights reserved.masimo, Signal Extraction Technology,, SET, Discrete Saturation Transform and DST are federally registered trademarks of Masimo Corporation.

Technical Bulletin 1 Signal Extraction Technology Introduction Masimo SET pulse oximetry is a new and fundamentally distinct method of acquiring, processing and reporting arterial oxygen saturation and pulse rate. As Illustrated below, Masimo SET technology enables the power of adaptive filters to be applied to real-time physiologic monitoring by utilizing proprietary techniques to accurately establish a noise reference in the detected physiologic signal, thus enabling the direct calculation of arterial oxygen saturation and pulse rate. Because it is not bound by a conventional red over infrared ratio approach, the Masimo SET system substantially eliminates the problems of motion artifact, low peripheral perfusion and most low signal-to-noise situations. This greatly extends the utility of SpO 2 in high motion, low signal and noise intensive environments. The superior performance of Masimo SET pulse oximetry has been clinically validated. The table below summarizes the results of one such study. Motion and Low Perfusion Study masimo corporation 40 parker irvine ca 92618 www.masimo.com Discrete Saturation Transform 1

Technical Bulletin 1 Conventional Filters While pulse oximetry is readily accepted as a standard of care in the Operating Room, Recovery Room and most Intensive Care Units, 1 its performance in high motion environments or in patients with low perfusion is substantially less than ideal. The reported high incidence of false alarms due to motion artifact 2 and the inability of conventional pulse oximetry systems to provide information during times of crisis have led to its characterization as a fair weather friend. 3 Confronted with the problem of motion artifact, false alarms and poor "signal to noise" environments, medical equipment manufacturers have utilized band-pass filtering in an attempt to address these confounding clinical problems. Band-pass filters, whether in analog or digital form, are designed to allow only a physiologic window of interest to pass while rejecting frequencies outside the desired frequency band. With the advent of Digital Signal Processing (Digital Filtering), the performance of band-pass filtering was improved, but was still unable to address the problem of noise occurring within the bandwidth of interest. Band-Pass Filtering In-Band Noise Amplitude 1 0 Ambient Light Electric Lines 0.5Hz 5Hz 60Hz 120Hz Frequency masimo corporation 40 parker irvine ca 92618 www.masimo.com Adaptive Filters To address the confounding issue of "in-band" noise, a class of filters known as adaptive digital filters has evolved. These filters take advantage of the fact that the construction of the filter itself is contained within the memory of the microprocessor, allowing its multiplication coefficients, symbolized as W 0, W 1,...W n-1, to be changed in real time, hence altering the filter's characteristic. Thus, the filter can be tuned on the fly. The multiplication coefficients determine whether the frequency components of an input signal should be cancelled (e.g., multiplied by zero) or allowed to pass (e.g., multiplied by one). Given that the filter's coefficients can be rapidly changed, adaptive filters derive their name in their ability to change their filtering characteristics in response to changing in-band noise. The detected physiologic signal is generally composed of both desired signal (S) and undesired signal (N) or noise portions. To remove the effects of the undesired signal, some knowledge of the noise characteristics, or equivalently its noise reference (N'), must be known. The adaptive filter will adjust its filtering characteristics, so that the noise reference input is transformed into an estimate

technical bulletin of the undesired signal portion ( N^) of the physiologic signal. A subtracter subsequently removes the undesired signal from the physiologic signal to yield an estimate of the desired signal portion ( S^). The combination comprising the adaptive filter and the subtracter is commonly called an adaptive noise canceller (). N l W 0 X W 1 X W 2 X Wn-2 X W n-1 X S+N ADAPTIVE ALGORITHM > Σ N + - Σ > S Adaptive Noise Canceller ( ) block diagram This approach has been widely used in the telecommunications and aerospace industries where a suitable noise reference is accessible. Probes are utilized to obtain a noise reference that can then be used in conjunction with an adaptive noise canceller to extract a desired signal portion from a composite signal containing both desired and undesired signal portions. The problem in applying this technique to physiological monitoring is that a noise reference is rarely available. In addition, both the noise and the desired signal vary from patient to patient and are quickly and continually changing in terms of frequency, amplitude and phase, even within the same patient. In pulse oximetry, the noise reference signal required to make an adaptive noise canceller work in real time was unavailable until the advent of Masimo Signal Extraction Technology. Conventional Pulse Oximetry The conventional "red over infrared" approach measures the differential optical density of red ( ) and infrared (I ir ) light as projected through a vascular bed and calculates a ratio (r) of the optical densities. Utilizing the optical density ratio, an arterial oxygen saturation (SpO 2 ) value is empirically reported based on the ratio obtained. 3

Technical Bulletin 1 660nm 940nm Emitters Arterial Supply Venous Return Photo-Detector & I ir Detector } Vascular Bed Capillaries Basis For Measurement: I ir S rd + N = rd = S ir + N ir Ratio (r) % SpO 2 In the presence of patient motion, the optical densities of red and infrared light contain noise portions (N rd, N ir ), thereby falsely altering the optical density ratio and providing an inaccurate saturation value. During periods of routine patient motion or low perfusion, the noise components within the physiologic signals can be much larger than the desired signals (S rd, S ir ). In these cases, the optical density ratio is primarily determined by the noise contributions. This represents a situation whereby the noise is simply drowning out the desired signal. In a large noise environment, conventional wisdom holds that pulse oximetry will yield an optical density ratio substantially equivalent to "noise over noise" or a ratio of one. This is equivalent to a saturation value of approximately 82% in most conventional systems. masimo corporation 40 parker irvine ca 92618 www.masimo.com If: N >> S, I ir N rd N ir Then: = 1 82% SpO 2 Confronted with the problems of overwhelming noise and prevented from utilizing adaptive digital filters, pulse oximetry manufacturers have resorted to managing false alarms. This can include extending averaging times or employing a decision matrix to freeze when it decides it has detected motion. If the motion persists, it reports zero 4. r Report New Value Decision Freeze & Report Old Value I ir Matrix Report Zero The attempt to treat the "symptom" rather than the core problem does not provide clinicians with continuous real-time information and can be unreliable in critical medical situations.

technical bulletin Masimo SET Pulse Oximetry Masimo Signal Extraction Technology rejects the conventional wisdom and begins with an understanding that during patient motion the venous blood, being at a relatively low pressure, is quite susceptible to the local effects of perturbation during motion. Considering the finger for example, the venous blood in the vascular bed will be easily deformed during motion, representing a significant source of in-band noise within the frequency bandwidth of interest. In addition, the venous blood is a strong absorber of light. Hence, it can represent a significant contributor to the total optical density during motion episodes. Furthermore, the venous blood saturation is normally lower than the arterial blood saturation. This explains why saturation values tend to drop in conventional pulse oximeter systems during episodes of patient motion. Arterial Supply > 80 mmhg Venous Return < 20 mmhg & I ir Detector } Vascular Bed Capillaries During routine patient motions (shivering, waving, tapping, etc.), the resulting noise can be quite substantial and can easily overwhelm a conventional ratio based oximetry system. Having identified the venous blood as a significant contributor to noise during motion, it follows that if the noise reference corresponding to the venous component could be measured, then an adaptive noise canceller might be utilized to cancel its contribution. Physiological Signal (S + N) Venous (N ) Noise Reference Adaptive Noise > (S) Arterial Signal 5

Technical Bulletin 1 Generating A Noise Reference The detected physiologic signals in response to both red ( ) and infrared (I ir ) light consist of desired signal portions (S rd, S ir ) as well as undesired signal portions (N rd, N ir ). It is commonly understood in pulse oximetry that the desired signal portions are proportional to one another through the arterial optical density ratio (r a ). This suggests that one should simply subtract the product of the arterial optical density ratio and the physiologic signal due to infrared light from the physiologic signal due to red light. The resultant is a reference signal that contains only noise portions. This is the noise reference signal (N ). If: ➅1 = S rd + N rd Ç2 I ir = S ir + N ir 3 ra = S rd 3 S ir S rd = r a S ir Then: - [I ir r a ] = [S rd + N rd ] - [S ir r a + N ir r a ] Substituting S ir r a for S rd, we get: = [ S ir r a + N rd ]-[ S ir r a + N ir r a ] = N rd - N ir r a = N I (Noise Reference) If the arterial optical density ratio is known, one can easily calculate the noise reference as just described. However, if it were known, one could simply calculate the arterial oxygen saturation directly. One would not need to utilize the adaptive noise cancellation process. How does one then use the power of adaptive filters and noise reference signals for pulse oximetry? The answer lies in the Discrete Saturation Transform algorithm. masimo corporation 40 parker irvine ca 92618 www.masimo.com Discrete Saturation Transformation The Discrete Saturation Transform algorithm allows one to separate and, consequently, calculate the optical density ratios that correspond to both the arterial oxygen saturation (r a ) and an estimate of the venous oxygen saturation (r v ). These optical densities are not known beforehand but are required to obtain the appropriate reference signals for adaptive noise cancellation. Every optical density ratio, corresponding to the patient s physiological range (SpO 2 = 1% to 100%), must be considered. Therefore, the DST algorithm not only uses a noise reference signal, but a whole family of reference signals. Each reference signal is used in the adaptive noise cancellation process and each yields information regarding the oxygen saturation content of the physiological signals. A family of reference signals, N'(r), is generated similar to that of a noise reference signal. The reference signal, as discussed earlier, is the difference between the physiologic signal due to red light ( ) and the product of an arbitrary optical density ratio (r) and the physiologic signal due to infrared light ( ). Although there is a family of reference signals, based on the selected optical density

technical bulletin ratio, there are only three distinct cases to consider. If one selects an optical density ratio that does not correspond to either arterial or venous oxygen saturation (Case I), the reference signal consists of a desired signal portion and an undesired signal portion. In the adaptive noise cancellation process, such a signal will not only remove the undesired signal portions of the physiologic signal, but also remove the desired signal portions. When an optical density ratio that corresponds to the venous oxygen saturation is s elected (Case II), the reference signal only contains signal portions. Therefore, the output of the adaptive noise canceller will consist of the undesired signal portions only. Similarly, when an optical density ratio that corresponds to the arterial oxygen saturation is selected (Case III), the reference signal only contains noise portions. Therefore, the output of the adaptive noise canceller will consist of the desired signal portions only. = S rd + N rd, I ir = S ir + N ir S rd = r a S ir, N rd = r v N ir Reference Signal: N'(r) = - r I ir r: optical density ratio r a : arterial optical density ratio r v : venous optical density ratio Case I: r r a, r v N'(r) = (r a - r) S ir + (r v - r) N ir Case II: r = r v N'(r v ) = (r a - r v ) S ir Case III: r = r a N'(r a ) = (r v - r a ) N ir For each selected value of the optical density ratio, the corresponding reference signal is calculated and subsequently processed through an adaptive noise canceller. - [ I ir r] = N I (r) Or : + - I ir r SpO 2 = 1, 2, 3... 100% N I (r) When the selected value for the optical density ratio does not correspond to either the arterial or the venous oxygen saturation (Case I), the corresponding output signal will contain little power. When the selected value for the optical density corresponds to either the venous oxygen saturation (Case II) or the arterial oxygen saturation (Case III), the output signal will contain significant output power. 7

Technical Bulletin 1 The power output of the adaptive noise canceller represents the probability that the selected optical density ratio, or its corresponding saturation value, is present in the physiologic signal. The output power or probability value is plotted for a series of consecutive ratio values generating the DST transform. During periods of no motion, a singular peak is generated in the DST transform corresponding to the arterial oxygen saturation. The more interesting example occurs during periods of motion when multiple peaks in the DST transform may be generated. Representative examples with sample waveform data are shown in the next section. Output Power DST Plot Typical No-Motion Data 30 40 50 60 70 80 90 95 100 SpO 2 (r a ) In summary, the procedure for determining the arterial oxygen saturation utilizing Masimo SET processing is as follows: masimo corporation 40 parker irvine ca 92618 www.masimo.com 1) Sweep all optical density ratios that correspond to oxygen saturations of 1% to 100%. 2) Compute the reference signal for each optical density ratio. 3) Measure the output power of the adaptive noise canceller for each reference signal. 4) Identify the appropriate peak in the DST transform that corresponds to the arterial oxygen saturation (largest SpO 2 value). I ir r + Σ - X Reference Signal SpO 2 = 1, 2, 3... 100% Adaptive Noise Canceller () output power Plot output power vs. all Possible r The above procedure demonstrates another important feature of Masimo SET pulse oximetry. It is able to calculate the arterial oxygen saturation without first extracting or determining discrete pulses in the physiologic data. For Masimo SET processing, the saturation algorithm is independent of the pulse rate algorithm. This is a significant distinction between Masimo SET systems and conventional pulse oximetry systems where the recognition of a clean pulse is a DST Plot

technical bulletin prerequisite for the calculation of accurate arterial oxygen saturation. Another advantage of Masimo SET technology is that it can monitor arterial oxygen saturation and pulse rate even if the motion starts before the pulse oximeter is turned on. It does not require clean data during instrument start-up. Discrete Saturation Transform Example In Figure A, a noise cancellation process for a selected optical density ratio corresponding to an oxygen saturation of 36% (Case I) is shown. For an SpO 2 of 36%, the calculated reference signal (shown in purple) is substantially similar to the physiologic signal due to red light (shown in red). These signals being similar effectively cancel each other within the adaptive noise canceller, yielding an output signal with little power content in the DST transform. 6 sec Σ + - X Reference Signal output power 6 sec r SpO 2 = 36 % Output Power 30 40 50 60 70 80 90 95 100 (r v ) SpO (r 2 a ) Figure A: During Motion DST plot at SpO 2 of 36% In Figure B, a noise cancellation process for another optical density ratio corresponding to an oxygen saturation of 60% (Case II) is shown. As is apparent, the reference signal (shown in red) looks quite different than the physiologic signal due to red light (shown in red). This yields an output signal with significant power content in the DST transform since the noise portion is not cancelled like the example in Figure A. I ir 6 sec + Σ - X Reference Signal output power 6 sec r SpO 2 = 60 % Output Power 30 40 50 60 70 80 90 95 100 (r v ) SpO 2 (r a ) Figure B: During Motion DST plot at SpO 2 of 60% 9

Technical Bulletin 1 In Figure C, a noise cancellation process for another optical density ratio corresponding to an oxygen saturation of 95% (Case III) is shown. In this particular instance, the reference signal is truly the noise reference. As is apparent, the noise reference (shown in blue) looks quite different from the physiologic signal due to red light (shown in red). This yields an output signal with significant power content in the DST transform since the signal portion is not cancelled like the examples in Figure A. I ir 6 sec Σ + - X Reference Signal output power 6 sec r SpO 2 = 95 % Output Power 30 40 50 60 70 80 90 95 100 (r v ) SpO (r 2 a ) Figure C: During Motion DST plot at SpO 2 of 95% masimo corporation 40 parker irvine ca 92618 www.masimo.com, Between the oxygen saturation values of 60% and 95%, and above 95%, the situation is similar to that of Figure A. That is to say the resulting output power in the DST transform will be relatively small. Hence, the resulting DST plot has two peaks. Being that the arterial oxygen saturation is greater than the venous oxygen saturation, the right-most peak in the DST plot is reported as the arterial oxygen saturation. The left-most peak in the DST plot is related to venous oxygen saturation. References 1. Anesthesiology 1993; 78:423-425 2. Anesthesiology 1993; 78:436-444 3. H.J.C. Swan, Ph.D., M.D. 4. SpO 2 Monitors with OXISMART Advanced Signal Processing and Alarm management Technology Pulse Oximetry Note Number 9.

1935 Matthes develops first 2-wavelength ear O 2 saturation meter with red and green filters, later switched to red and infrared filters. First device to measure O 2 saturation. 1949 Wood adds pressure capsule to squeeze blood out of ear to obtain zero setting in an effort to obtain absolute O 2 saturation value when blood was readmitted. Concept similar to today s conventional pulse oximetry but suffered due to unstable photocells and light sources. Not used clinically. 1981 In 1972, Aoyagi at Nihon Kohden invents conventional pulse oximetry using the ratio of red to infrared light absorption of pulsating components at the measuring site. It was commercialized by BIOX/ Ohmeda in 1981 and Nellcor in 1983. Civilization took 10 Thousand Years to Evolve... Pulse Oximetry took only 60. 1942 Millikan develops optical blood oxygen saturation method because Air Force fighter pilots were blacking out at high G forces. Arterialized blood in ear by heating, coined the term oximeter. 1964 Shaw assembles first absolute-reading ear oximeter by using eight wavelengths. Commercialized by Hewlett Packard, use was limited to pulmonary function and sleep laboratories due to cost and size. In 1989, Diab and Kiani at Masimo Corporation invent Signal Extraction Pulse Oximetry which enables the use of many breakthrough technologies, including parallel engines, adaptive filters, Discrete Saturation Transform, and Fast Saturation Transform, to separate the arterial signal from the non-arterial noise (e.g. venous blood movement during motion). The result was a pulse oximetry technology that has been scientifically and clinically proven to be accurate during patient motion, and low perfusion. In 1998, Masimo unveiled this breakthrough technology to clinicians. As of today, more than 70% of the world s pulse oximetry manufacturers have licensed Masimo SET technology to make Signal Extraction Pulse Oximetry available to clinicians worldwide. 1998