Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Similar documents
Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

4/3 proportional directional valve direct operated, with integrated electronics

Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH. Features.

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

Directional control valve, direct operated, with integrated digital axis controller (IAC Multi Ethernet) Type 4WRPDH. Features.

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

Proportional directional valves

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional pressure valves

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

4/3-way fast response valve Type 4WRGE

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

Electric amplifier for flow control with proportional

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Direct Operated Proportional DC Valve Series D1FP

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

Valve amplifier for proportional pressure valves

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Electric amplifier for proportional cartridge throttle valves

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

DENISON HYDRAULICS Proportional Pressure Control Valves

Proportional Directional Control Valves Nominal sizes 16 and 25

Analog amplifier RA. RE Edition: Replaces:

Electro-Hydraulic 4-Way Directional Servo Valve Model 4 WS 2 E.10 and 4 WSE 2 E. 10 (Series 4X) PSI (315 bar) K K

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Proportional Directional Control Valves Size 6

p/q closed-loop control amplifier

RA / /6. Replaces: Table of contents RA /06.98

Proportional flow valves digital, pressure compensated, direct operated, with position transducer

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Proportional Directional Control Valves Size 6

4/3 Proportional Directional Valve, Size SAE 10

Service case with test unit for servo and proportional valves with integral electronics (OBE)

Direct Drive Digital Control

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Directional valves Electrically operated Series 563, 565, 567. Brochure

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Proportional Directional Control Valves Series D1FB. General Description. Features. D1FB*3 OBE Spool/Body Design. D1FB*0 OBE Spool/Sleeve Design

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

SERVO VALVES. Maximum Flow. Maximum Operating Pressure MPa (PSI) U.S.GPM Page. Graphic Symbols.

External control electronics for the SYDEF1 adjustment of the A10VSO axial piston pump

High-quality pressure transmitter For general industrial applications Model S-20

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control

Proportional Directional Valves with Feedback KBFDG4V-5-2C75N45-Z-M1-PC7-H7-12-EN123/EN150. Pressures to 315 bar (4500 psi)

Servo-Performance Proportional Directional Valves with Feedback. K(B)SDG4V-3 1* Series Pressures to 350 bar (5075 psi)

Pressure transmitter For general industrial applications Model A-10

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Electronically controlled proportional pressure regulating valves

Speed sensors for general applications:

Pressure Transmitter SIL

RT-5005/5006/5007/5008

2/2 way Proportional Valve (motordriven)

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Digital flow transmitter for continuous flow measurement

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

ph or ORP Transmitter

Speed sensor DSA series 12

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Electronic temperature switch with display Model TSD-30

Digital flow ELEMENT transmitter for continuous flow measurement

Pressure transmitter for general industrial applications Model A-10

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

INLINE flowmeter for continuous flow measurement

Digital electronic TEB/LEB drivers integral-to-valve format, for proportional valves with one or two spool position transducers

Temposonics. Magnetostrictive Linear Position Sensors. EH IO-Link Data Sheet

Flush pressure transmitter For viscous and solids-containing media Model S-11

AxCent Servo Drive A25A100

Digital flow ELEMENT transmitter for continuous flow measurement

Ultrasonic level measuring device, non-contact

Type CP-S, CP-C & CP-A Switch mode

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

External control electronics for the SYDFE1 control of A10VSO axial piston pumps Analogue amplifier, configurable

Pressure transmitter for general industrial applications Model A-10

Electrohydraulic Actuator Type PVEP / PVEP-F

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

AxCent Servo Drive A50A100

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Digital inductive conductivity transmitter

Electromagnetic Flow Transmitter

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Generator Speed Controller Model GSC 1

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH*-8 10 Series

Directional valves Coils Series CO1. Brochure

Lexium integrated drives

Check valve type RK and RB

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

LSV(H)G Series High-speed Linear Servo Valves

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

Transcription:

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type WRPEH RE 9 Edition: 8- Replaces: 7-5 Size 6 Component series 3X Maximum operating pressure 35 bar Rated flow... l/min 59m Features Reliable - proven and robust design Safe - fail-safe position of the control spool in switchedoff condition Energy-efficient - no pilot oil demand High quality - control spool and sleeve in servo quality Flexible - suitable for position, velocity and pressure control Precise - high response sensitivity and little hysteresis IO-Link interface, optional Contents Features Ordering code Symbols 3 Function, section Technical data 5 7 Block diagram/controller function block 8 Electrical connections and assignment 9 Characteristic curves 8 Dimensions 9, Accessories Further information RE 9, edition: 8-, Bosch Rexroth AG

/ WRPEH Directional control valve Ordering code 3 5 6 7 8 9 3 5 6 WRP E H 6 B 3X / / * main ports Directional control valve, direct operated WRP 3 With integrated electronics E Control spool/sleeve H 5 Size 6 6 6 Symbols e.g. C, C, C5 etc.; for possible design, see page 3 7 Installation side of the inductive position transducer B Rated flow ( p = 35 bar/control edge) 8 Flow characteristic "L" "P" l/min (Inflection at %) l/min 5 l/min (Inflection at 6%) 5 l/min 5 l/min (Inflection at 6%) 5 l/min (Inflection at %) Flow characteristic 9 Linear L Inflected characteristic curve, linear P Component series 3 39 (3 39: unchanged installation and connection dimensions) 3X Seal material NBR seals M FKM seals V Without damping plate no code With damping plate D 3 Supply voltage of the integrated electronics: VDC Interfaces of the control electronics Command value input ± V A Command value input... ma F IO-Link interface L 5 Without electronics protection membrane no code With electronics protection membrane 67 6 Further details in the plain text Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH 3/ Symbols A B A B a b a b b P T P T C3 C5 C C C With symbols C5 and C: ) P A: q V nom B T: q V nom / P B: q V nom / A T: q V nom Notice: Representation according to DIN ISO 9-. Hydraulic interim positions are shown by dashes. ) q V nom : in connection with flow characteristics "P" for rated flow l/min only (version "") Flow characteristic Symbol Linear characteristic curve (version "L") Inflection 6% (q V nom = 5.5 l/min) Inflected characteristic curve (version "P") Inflection % Inflection % q V q V q V q V C3, C5 C, C s s s s q V q V q V q V C s s s s RE 9, edition: 8-, Bosch Rexroth AG

/ WRPEH Directional control valve Function, section Valves of type WRPEH are direct operated directional control valves with electrical position feedback and integrated electronics (OBE). Set-up The WRPEH high-response valve mainly consists of: Valve housing with control spool and sleeve in servo quality () Control solenoid with position transducer () (optionally with electronics protection membrane (5)) On-board electronics (OBE) (3) with analog or IO-Link interface () (optionally with damping plate (6)) Function The integrated electronics (OBE) compares the specified command value to the position actual value. In case of control deviations, the stroke solenoid will be activated. Due to the changed solenoid force, the control spool is adjusted against the spring. Stroke/control spool crosssection is controlled proportionally to the command value. In case of a command value presetting of, the electronics adjusts the control spool against the spring to central position. In deactivated condition, the spring is untensioned to a maximum and the valve is in fail-safe position. Control solenoid shut-off In case of the following errors, the control solenoid is de-energized by the integrated electronics (OBE) and the control spool is set to fail-safe position: Falling below the minimum supply voltage Only at interface "F": Falling below the minimum current command value of ma (includes cable break of the command value line (current loop)) Only at interface "L": Enable inactive, communication interruption (watchdog) In case of internal IO-Link error Damping plate "D" The damping plate reduces the acceleration amplitudes on the on-board electronics (frequencies >3 Hz). Notice: Use of the damping plate is not recommended for applications with mainly low-frequency excitation <3 Hz Electronics protection membrane "67" To prevent condensate formation in the housing of the integrated electronics (OBE), an electronics protection membrane (5) can be used. Recommended for use outside industry-standard conditions with high ambient air humidity and significant cyclic temperature changes (e.g. outdoors). 3 6 5 Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH 5/ Technical data (For applications outside these parameters, please consult us!) general Design Spool valve, direct operated, with steel sleeve Actuation Proportional solenoid with position control, OBE Type of connection Subplate mounting, porting pattern according to ISO Installation position any Ambient temperature range C +6 Transport temperature C 3 +8 Maximum storage time Years (if the storage conditions are observed; refer to the operating instructions 76-B) Sine test according to Without damping plate... Hz / maximum of g / cycles / 3 axes DIN EN 668--6 With damping plate )... Hz / maximum of g / cycles / 3 axes Noise test according to Without damping plate Hz / g RMS / 3 g peak / 3 min. / 3 axes DIN EN 668--6 With damping plate )... Hz / g RMS / 3 g peak / h / 3 axes Transport shock according Without damping plate 5 g / ms / 3 shocks / 3 axes to DIN EN 668--7 With damping plate ) 5 g / ms / 3 shocks / 3 axes Shock according to DIN EN 668--7 With damping plate ) 35 g / 6 ms / shocks / 3 axes Weight kg.9 Maximum relative humidity (no condensation) % 95 Maximum solenoid surface temperature C 5 MTTF d value according to EN ISO 389 Years 5 (for further details see data sheet 8) Conformity CE according to EMC directive /3/EU, tested according to EN 6-6- and EN 6-6-3 RoHS directive 5/65/EU REACH ordinance (EC) no. 97/6 hydraulic Maximum operating pressure Port A, B, P bar 35 Port T bar 5 Rated flow at p = 35 bar/control edge ) l/min 5 /5 Hydraulic fluid see table page 6 Viscosity range Recommended mm /s Maximum admissible mm /s 8 Hydraulic fluid temperature range (flown-through) C +7 Maximum admissible degree of contamination of the hydraulic fluid; cleanliness class according to ISO 6 (c) Class 8/6/3 3) Limitation of use ( p) with regard to the transition to failsafe (values apply to summated edge) Leakage flow at bar Symbols C3, C5, C bar 35 35 35 35 6 Symbols C, C bar 35 35 8 5 Linear characteristic curve "L" Inflected characteristic curve "P" cm 3 /min < 8 < 3 < 5 < 9 cm 3 /min < 5 < 8 < 3 < 5 ) Not recommended for applications with mainly low-frequency excitation < 3 Hz ) Flow for deviating p (control edge): q x = q Vnom p x 35 3) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of filters, see www.boschrexroth.com/filter. RE 9, edition: 8-, Bosch Rexroth AG

6/ WRPEH Directional control valve Technical data (For applications outside these parameters, please consult us!) Hydraulic fluid Classification Suitable Standards Data sheet sealing materials Mineral oils HL, HLP, HLPD, HVLP, HVLPD NBR, FKM DIN 55 9 Bio-degradable Insoluble in water HETG NBR, FKM ISO 538 9 HEES FKM Soluble in water HEPG FKM ISO 538 Flame-resistant Water-free HFDU, HFDR FKM ISO 9 9 Containing water HFC (Fuchs Hydrotherm 6M, Petrofer Ultra Safe 6) NBR ISO 9 93 Important information on hydraulic fluids: Flame-resistant containing water: For further information and data on the use of other hydraulic Maximum operating pressure bar fluids, please refer to the data sheets above or contact us! Maximum pressure differential per control edge 75 bar There may be limitations regarding the technical valve data Pressure pre-loading at the tank port >% of the pressure (temperature, pressure range, life cycle, maintenance intervals, differential, otherwise increased cavitation erosion etc.)! Life cycle as compared to operation with mineral oil HL, HLP The ignition temperature of the hydraulic fluid used must be K 5 % higher than the maximum solenoid surface temperature. Maximum hydraulic fluid temperature 5 C static / dynamic Hysteresis % <. Range of inversion % <.5 Response sensitivity % <.5 Manufacturing tolerance q Vmax % < Temperature drift (temperature range C... 8 C) Zero shift <.5% with ϑ = K Pressure drift %/ bar Zero shift <.5 Zero compensation Ex plant ±% electrical, integrated electronics (OBE) Interface "A" and "F" Relative duty cycle % (continuous operation) Protection class according to EN 659 IP 65 with mounted and locked plug-in connectors Supply voltage VDC Terminal A VDC min. 9 / max. 36 Terminal B VDC Maximum admissible residual ripple Vpp.5 Maximum power consumption VA Fuse protection, external A T.5 (time-lag) Input, version "A" Differential amplifier, R i = kω Terminal D (U E ) VDC ± Terminal E VDC Input, version "F" Load, R sh = Ω Terminal D (I D-E ) ma Terminal E (I D-E ) Current loop I D-E feedback Maximum voltage of the differential inputs against V D B; E B (max. 8 V) Test signal, version "A" LVDT Terminal F (U Test ) VDC ± Terminal C Reference V Test signal, version "F" ma LVDT signal at external load 5 Ω maximum Terminal F (I F-C ) ma output Terminal C (I F-C ) Current loop I F-C feedback Functional ground and screening see pin assignment on page 9 (CE-compliant installation) Adjustment Calibrated in the plant, see valve characteristic curves page 8 Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH 7/ Technical data (For applications outside these parameters, please consult us!) electrical, integrated electronics (OBE) Interface "L" Relative duty cycle % (continuous operation) Protection class according to EN 659 IP 65 with mounted and locked plug-in connectors Supply voltage Valve amplifier VDC Pin VDC min. 8 / max. 3 Pin 5 VDC IO-Link interface VDC Pin VDC min. 8 / max. 3 Pin 3 VDC Maximum current consumption Valve amplifier A IO-Link interface ma 5 Maximum residual ripple Vpp.3 Maximum current consumption ma 5 Minimum process cycle time ms.6 Bit rate COM3 kbaud (kbit/s) 3, Required master port class Class B Resolution A/D transformer bit (% valve opening) D/A transformer bit (% valve opening) Functional ground provide via valve block Adjustment calibrated in the plant Directive IO-Link Interface and System Specification Version.. RE 9, edition: 8-, Bosch Rexroth AG

8/ WRPEH Directional control valve Block diagram/controller function block A B Interface "A"/"F" Interface "L" Valve amplifiers Valve Enable Enable Logic Enable Output stage status P On/Off output stage Output stage status T a b Run/stop Position controller Comparison ma Cable break detection... ma Zw Command value D U U/I Command value Command value EMV E F C VDC VDC A EMV B V PE 6+PE I Position controller U DAC Command value standardization Command value reference Command value reference Output stage Microcontroller Comparison Demodulator Output position actual value Actual value = U U/I Actual value Actual value EMV U U ADC Actual value reference Actual value reference Gx Oscillator = Undervoltage detection Supply output stage VDC Inversepolarity protection V EMV L+ C/Q L- P L Inversepolarity protection M V Power supply unit U VDC A-coded Class B U V FE FE Housing Housing Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH 9/ Electrical connections and assignment Connector pin assignment "A" and "F" Pin Signal Assignment interface "A" Assignment interface "F" A VDC Supply voltage B V C Reference potential actual value Reference potential actual value - pin F D Command value ± V Command value ma Differential amplifier input E Reference potential command value - pin D F Measuring output (actual value) Actual value ± V Actual value ma PE Functional ground (directly connected to the valve housing) F E A PE D B C Command value Connection cable Positive command value ( V or ma) at D and reference potential at E cause flow from P A and B T. Negative command value ( V or ma) at D and reference potential at E cause flow from P B and A T. Up to m cable length type LiYCY 7 x.75 mm Up to m cable length type LiYCY 7 x. mm EMC compliant installation: Apply screening to both line ends Use metal mating connector (see page ) Alternatively up to 3 m cable length admissible Apply screening on supply side Plastic mating connector (see page ) can be used Notice: Mating connectors, separate order, see data sheet 86. Connector pin assignment "L" (M-5, A-coded, class B) 3 5 3 5 P L+ L- N C/Q Power Voltage supply Power additional voltage supply Notes: M sensor/actuator connection line, 5-pole; M connector/ bush, A-coded, without shield, maximum cable length m. Observe the voltage drop over the cable. Wire cross-section at least.3 mm. Mating connectors, separate order, see page and data sheet 86. Communication and parameter description see data sheet 9-PA Pin Signal Allocation interface L L+ Voltage supply IO-Link P Voltage supply valve electronics and power part (current consumption A) 3 L- Reference potential pin ) C/Q Data line IO-Link (SDCI) 5 N Reference potential pin ) ) Pin 3 and 5 are linked with each other in the valve electronics. The reference potentials L- and N of the two supply voltages must also be linked with each other on the power supply unit side. RE 9, edition: 8-, Bosch Rexroth AG

/ WRPEH Directional control valve Characteristic curves: Flow characteristic "L" (measured with HLP6, ϑ Oil = ±5 C; p = 35 bar/control edge) Flow/signal function Symbol C, C3 and C Version "" 3 - -8-6 - - 6 8 P A; B T P B; A T - - -3 - - 3 5 6 7 8 9 Symbol C, C3 and C Version "" 8 6 - -8-6 - - 6 8 P A; B T P B; A T - - -3 - - 3 5 6 7 8 9 Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH / Characteristic curves: Flow characteristic "L" (measured with HLP6, ϑ Oil = ±5 C; p = 35 bar/control edge) Flow/signal function Symbol C, C3 and C Version "" 6 8 - -8-6 - - 6 8 P A; B T P B; A T - - -3 - - 3 5 6 7 8 9 Symbol C, C3 and C Version "" 35 3 5 5 5 - -8-6 - - 6 8 P A; B T P B; A T - - -3 - - 3 5 6 7 8 9 RE 9, edition: 8-, Bosch Rexroth AG

/ WRPEH Directional control valve Characteristic curves: Flow characteristic "L" (measured with HLP6, ϑ Oil = ±5 C; p = 35 bar/control edge) Flow/signal function Symbol C and C5 Version "" 3 3 - -8-6 - - 6 8 P A B T 3 P B A T - - -3 - - 3 5 6 7 8 9 Symbol C and C5 Version "" 8 6 3 - -8-6 - - 6 8 P A B T 3 P B A T - - -3 - - 3 5 6 7 8 9 Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH 3/ Characteristic curves: Flow characteristic "L" (measured with HLP6, ϑ Oil = ±5 C; p = 35 bar/control edge) Flow/signal function Symbol C and C5 Version "" 6 3 8 - -8-6 - - 6 8 P A B T 3 P B A T - - -3 - - 3 5 6 7 8 9 Symbol C and C5 Version "" 35 3 5 3 5 5 - -8-6 - - 6 8 P A B T 3 P B A T - - -3 - - 3 5 6 7 8 9 RE 9, edition: 8-, Bosch Rexroth AG

/ WRPEH Directional control valve Characteristic curves: Flow characteristic "P" (measured with HLP6, ϑ Oil = ±5 C; p = 35 bar/control edge) Flow/signal function Symbol C, C3 and C Version "" 3 - -8-6 - - 6 8 P A; B T P B; A T - - -3 - - 3 5 6 7 8 9 5 8 6 Symbol C, C3 and C Version "5" - -8-6 - - 6 8 P A; B T P B; A T - - -3 - - 3 5 6 7 8 9 Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH 5/ Characteristic curves: Flow characteristic "P" (measured with HLP6, ϑ Oil = ±5 C; p = 35 bar/control edge) Flow/signal function 5 Symbol C, C3 and C Version "5" 5 5 - -8-6 - - 6 8 P A; B T P B; A T - - -3 - - 3 5 6 7 8 9 Symbol C, C3 and C Version "" 35 3 5 5 5 - -8-6 - - 6 8 P A; B T P B; A T - - -3 - - 3 5 6 7 8 9 RE 9, edition: 8-, Bosch Rexroth AG

6/ WRPEH Directional control valve Characteristic curves: Flow characteristic "P" (measured with HLP6, ϑ Oil = ±5 C; p = 35 bar/control edge) Flow/signal function Symbol C and C5 Version "" 35 3 5 3 5 5 - -8-6 - - 6 8 P A B T 3 P B A T - - -3 - - 3 5 6 7 8 9 Fail-safe position: Flow/leakage flow C A B Fail-safe position Rated flow at Δp = 35 bar/control edge Flow at Δp = 35 bar/control edge l/min 5 /5 l/min 3 8 b P T C3, C5 A B P T b Leakage flow at bar P A cm³/min 5 P B cm³/min 7 Flow at A T l/min Δp = 35 bar B T l/min 7 C, C A B P T b Leakage flow at bar P A cm³/min 5 P B cm³/min 7 A T cm³/min 7 B T cm³/min 5 Fail-safe p = bar 7 ms p = bar ms Internal shut-off in case of the following errors: Drop of supply voltage U B 5 V and restarting at U B 7.5 V. Only at interface "F": Falling below the minimum current command value of ma (includes cable break of the command value line (current loop)) Only at interface "L": Enable inactive, communication interruption (watchdog) In case of internal IO-Link error Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH 7/ Characteristic curves (measured with HLP6, ϑ Oil = ±5 C) Pressure/signal characteristic curve p A B [%p p ] p A/B 8 6 A B p P P T b X D-E [%] - -3 - - 3 X D-E [%] - - -6-8 - p B A [%p p ] Transition function with stepped electric input signals Signal change in % 75 75 Stroke in % 5 5 5 5 5 5 5 5 Time in ms RE 9, edition: 8-, Bosch Rexroth AG

8/ WRPEH Directional control valve Characteristic curves (measured with HLP6, ϑ Oil = ±5 C) Frequency response characteristic curves Amplitude ratio in db Phase angle in Frequency in Hz Signal ± % Signal ±5% Signal ±5% Signal ±% Flow/load function with maximum valve opening 5 3 Version "CB" "CB5" 3 "CB5" "CB" 5 "CB" Valve pressure differential in bar Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH 9/ Dimensions (dimensions in mm) 5 6 5. 9 5 9. 8.3 5. (7.7) 9.3 3 3.5 Ø5.3 6 3 85. 7 65 5.,/ Rzmax 6 5 Required surface quality of the valve contact surface 7 8 5 F A F P 7 7 T Notice: The dimensions are nominal dimensions which are subject to tolerances. F B F3 Valve housing Integrated electronics 3 Identical seal rings for ports P, A, B, T. Mating connectors with version "A" and "F", separate order, see page data sheet 86. Mating connectors with version "L", separate order, see page data sheet 86 5 Space required to remove the mating connector 6 Control solenoid with position transducer 7 Machined valve contact surface, porting pattern according to ISO -3---5 Deviating from the standard: Ports P, A, B, T Ø8 mm Minimum screw-in depth: Ferrous metal.5 x Ø Non-ferrous x Ø 8 Damping plate "D" 9 Dimension in () for version with damping plate "D" Electronics protection membrane "67" RE 9, edition: 8-, Bosch Rexroth AG

/ WRPEH Directional control valve Dimensions Valve mounting screws (separate order) hexagon socket head cap screws Material number ISO 76 - M5 x 3 -.9-CM-Fe-ZnNi-5-Cn-T-H-B R93886 Tightening torque M A = 7 Nm ± % or ISO 76 - M5 x 3 -.9 Not included in the Rexroth delivery range Tightening torque M A = 8.9 Nm ± % or ASME B8.3 - - UNC x /" - ASTM-A57 Not included in the Rexroth delivery range Tightening torque M A = 8. Nm [5.9 ft-lbs] ± % Notice: The tightening torque of the hexagon socket head cap screws refers to the maximum operating pressure. Subplates (separate order) with porting pattern according to ISO -3---5 see data sheet 5. Accessories (separate order) Valve with integrated electronics Interface Mating connectors 6-pole + PE Design Version Material number Data sheet "A", "F" For the connection of valves with integrated straight Metal R9389 86 electronics, round connector 6+PE, line cross-section straight Plastic R967 86.5.5 mm² angled Plastic R9785 "L" Cable sets 6-pole + PE Length in m Material number Data sheet For the connection of valves with integrated 3. R983 86 electronics, round connector 6+PE, straight 5. R99 86 connector, shielded, potted-in mating connector, line. R996 86 cross-section.75 mm². R9868 Test and service devices Material number Data sheet Service case with test device for proportional servo valves with integrated electronics (OBE) 9685 IO-Link gateways Designation Description Material number S67E-PN-IOL8-DI-M-6P IndraControl S67E R9736 PROFINET device in the plastic housing 8 IO-Link ports ( x class A and x class B), digital inputs, VDC, M quick connection technology S67E-S3-IOL8-DI-M-6P IndraControl S67E Sercos device in the plastic housing 8 IO-Link ports ( x class A and x class B), digital inputs, VDC, M quick connection technology R9737 Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH / Further information Hydraulic valves for industrial applications Data sheet 76-B Subplates Data sheet 5 Hydraulic fluids on mineral oil basis Data sheet 9 Environmentally compatible hydraulic fluids Data sheet 9 Flame-resistant, water-free hydraulic fluids Data sheet 9 Flame-resistant hydraulic fluids - containing water (HFAE, HFAS, HFB, HFC) Data sheet 93 Reliability characteristics according to EN ISO 389 Data sheet 8 Hexagon socket head cap screw, metric/unc Data sheet 8936 Installation, commissioning and maintenance of servo valves and Data sheet 77 high-response valves Assembly, commissioning and maintenance of hydraulic systems Data sheet 79 Selection of filters www.boschrexroth.com/filter Information on available spare parts www.boschrexroth.com/spc RE 9, edition: 8-, Bosch Rexroth AG

/ WRPEH Directional control valve Notes Bosch Rexroth AG Industrial Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +9 () 93 5 / 3 my.support@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Bosch Rexroth AG, RE 9, edition: 8-

Directional control valve WRPEH 3/ Notes Bosch Rexroth AG Industrial Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +9 () 93 5 / 3 my.support@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. RE 9, edition: 8-, Bosch Rexroth AG

/ WRPEH Directional control valve Notes Bosch Rexroth AG Industrial Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +9 () 93 5 / 3 my.support@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Bosch Rexroth AG, RE 9, edition: 8-