motor that is connected to an inverter as a load (Fig. 2). The motor s winding can be thought of as an R-L load consisting of a resistance and inducta

Similar documents
High-precision Power Measurement of SiC Inverters

Identification of PMSM Motor Parameters with a Power Analyzer

High-precision, Wideband, Highly Stable Current Sensing Technology

AC/DC Current Probe CT6844/CT6845/CT6846

World-Class Accuracy & Measurement Range (40 Conventional Models)

Harmonic Filtering in Variable Speed Drives

Experiment 3. Performance of an induction motor drive under V/f and rotor flux oriented controllers.

Oscillators. An oscillator may be described as a source of alternating voltage. It is different than amplifier.

Application Note AN- 1094

Methods for Reducing Leakage Electric Field of a Wireless Power Transfer System for Electric Vehicles

AC/DC Current Probe CT6841/CT6843

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1

Module 4. AC to AC Voltage Converters. Version 2 EE IIT, Kharagpur 1

Applications & Cases. EPCOS AG A TDK Group Company Edition

POWER- SWITCHING CONVERTERS Medium and High Power

Efficiency Improvement of High Frequency Inverter for Wireless Power Transfer System Using a Series Reactive Power Compensator

Simulation Analysis of SPWM Variable Frequency Speed Based on Simulink

Lecture 19 - Single-phase square-wave inverter

Examples Paper 3B3/4 DC-AC Inverters, Resonant Converter Circuits. dc to ac converters

INTRODUCTION TO AC FILTERS AND RESONANCE

Modeling of Conduction EMI Noise and Technology for Noise Reduction

Mitigation of Harmonics and Interharmonics in VSI-Fed Adjustable Speed Drives

A Thyristor Controlled Three Winding Transformer as a Static Var Compensator

Testing Power Sources for Stability

International Journal of Advancements in Research & Technology, Volume 7, Issue 4, April-2018 ISSN

Technical Brief: Flow Direction of Harmonics and High- order Harmonics

Hysteresis Controller and Delta Modulator- Two Viable Schemes for Current Controlled Voltage Source Inverter

Development of a Single-Phase PWM AC Controller

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

OPERATIONAL AMPLIFIER PREPARED BY, PROF. CHIRAG H. RAVAL ASSISTANT PROFESSOR NIRMA UNIVRSITY

The analysis and Compensation of dead-time effects in three phase PWM inverters

Improving Passive Filter Compensation Performance With Active Techniques

CHAPTER 9. Sinusoidal Steady-State Analysis

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

Core Technology Group Application Note 1 AN-1

Harmonics White Paper

Fluxgate Magnetometer

Wide-band Models from DC to 100 MHz

Non-Contact AC Voltage Probe SP3000, AC Voltage Probe SP9001

CHAPTER 1 INTRODUCTION

Chapter 11. Alternating Current

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

Beyond Electromagnetic Component Modeling: Extending Finite Element Analysis to Include Multidomain System Simulation

Maxim > Design Support > Technical Documents > Application Notes > Energy Measurement & Metering > APP 5292

CHAPTER 3 MODIFIED SINE PWM VSI FED INDUCTION MOTOR DRIVE

Exercise 1: Series RLC Circuits

Reduction in Radiation Noise Level for Inductive Power Transfer System with Spread Spectrum

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

LOW ORDER HARMONICS IMPROVEMENT OF A SINGLE GRID CONNECTED INVERTER SYSTEM UNDER PR CONTROL TECHNIQUE

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

Resonant Power Conversion

CHAPTER 3 ACTIVE INDUCTANCE SIMULATION

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

AC Power Instructor Notes

Improved Real/Reactive Power Management and Controls for Converter-Based DERs in Microgrids

A Current-Source Active Power Filter with a New DC Filter Structure

Voltage-Mode Grid-Tie Inverter with Active Power Factor Correction

Output Voltage Correction of an Induction Motor Drive Using a Disturbance Observer with Speed Sensor-less Vector Control Method

Analysis of Harmonic Reduction for Synchronized Phase-shifted Parallel PWM Inverters with Current Sharing Reactors

A White Paper on Danley Sound Labs Tapped Horn and Synergy Horn Technologies

Power Meter PW3335. Ken Sakai Engineering Division 4, Engineering Department. Power Meter PW3335

University of North Carolina-Charlotte Department of Electrical and Computer Engineering ECGR 4143/5195 Electrical Machinery Fall 2009

An Active Interphase Transformer for 12-Pulse Rectifier System to Get the Performance Like 24- Pulse Rectifier System

Switching Loss Characteristics of Sequences Involving Active State Division in Space Vector Based PWM

Filter Considerations for the IBC

CURRENT FOLLOWER APPROACH BASED PI AND FUZZY LOGIC CONTROLLERS FOR BLDC MOTOR DRIVE SYSTEM FED FROM CUK CONVERTER

CHAPTER 5 NOVEL CARRIER FUNCTION FOR FUNDAMENTAL FORTIFICATION IN VSI

Single-Phase Grid-Tied Inverter (PWM Rectifier/Inverter)

Development of Distributed-type Linear Generator with Damping Control. Toshiaki MURAI Chief Researcher,

INTEGRATED CIRCUITS. AN1221 Switched-mode drives for DC motors. Author: Lester J. Hadley, Jr.

Generalized Multilevel Current-Source PWM Inverter with No-Isolated Switching Devices

Power Factor. Power Factor Correction.

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

AN IMPROVED MODULATION STRATEGY FOR A HYBRID MULTILEVEL INVERTER

4 Transistors. 4.1 IV Relations

Comparison of Different Common Passive Filter Topologies for Harmonic Mitigation

Trends in Power Electronics for High-Power Applications

Minimizing Input Filter Requirements In Military Power Supply Designs

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Laboratory Project 4: Frequency Response and Filters

Exercise 2: Parallel RLC Circuits

Investigation of Coupling of EMC Disturbances in Doubly Fed Induction Generators

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Study on Voltage Controller of Self-Excited Induction Generator Using Controlled Shunt Capacitor, SVC Magnetic Energy Recovery Switch

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

Micro-controller Based Three-phase Voltage Source Inverter for Alternative Energy Source. Abstract

RS232. DC POWER SUPPLY 20kW 3 RANGES

Considerations for Choosing a Switching Converter

Xitron Technologies Inc - 3-Phase Total Power Parameters & Configurations Applications Note. Application Note

New Technique Accurately Measures Low-Frequency Distortion To <-130 dbc Levels by Xavier Ramus, Applications Engineer, Texas Instruments Incorporated

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

DC/DC-Converters in Parallel Operation with Digital Load Distribution Control

( ) ON s inductance of 10 mh. The motor draws an average current of 20A at a constant back emf of 80 V, under steady state.

DEVELOPMENT OF A SILENT BRUSHLESS DC MOTOR DRIVE. S. Camilleri, D. Patterson & H. Pullen

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

Use of Advanced Unipolar SPWM Technique for Higher Efficiency High Power Applications

University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Transcription:

Effectiveness of Phase Correction When Evaluating the Efficiency of High-efficiency Motor Drives By Hideharu Kondo, Chiaki Yamaura, Yukiya Saito, Hiroki Kobayashi 1. Introduction Against the backdrop of international efforts to prevent global warming, the increasingly efficient motor drive systems used in electric vehicles and industrial applications have been attracting attention in recent years. Essential in evaluating the efficiency and loss of motor drive systems, the ability to measure power accurately demands a range of expertise. This paper focuses on the characteristics of inverter output s in order to outline requirements for the power measuring instruments that are needed to accurately measure inverter output power. It also introduces phase correction by a power analyzer with a focus on current sensor phase error in order to satisfy those requirements. Finally, it reports on the authors verification of the effectiveness of current sensor phase correction. 2. Characteristics of inverter output s Principal components of inverter output power include a fundamental frequency component (up to 2 khz), its harmonic components, the switching frequency (5 khz to 100 khz), and its harmonic components. Of those, the fundamental frequency component is dominant. Fig. 1 illustrates an inverter output s line voltage, line current, and associated FFT results for a typical motor drive system. Table 1 provides detailed information about the measurement target. Looking at the voltage FFT results, it is possible to observe the fundamental wave that is the principal component of the line voltage PWM and its harmonics, along with the switching frequency and its harmonic components. A spectrum of at least 0.1% f.s. exists up to approximately 2 MHz. Fig. 1: Waveform and FFT results for an inverter-driven motor (measured using the Hioki Power Analyzer PW6001) Inverter Switching element SiC-MOSFET SCH2080KE (ROHM) Switching frequency Inductance Motor Resistance Rated power output 20 khz 3.6 mh 0.9 Ω 120 W Table 1: Measurement target specifications FFT spectrum The fundamental wave, its harmonics, the switching frequency, and its harmonic components can also be observed for the current. However, the observed spectrum at frequencies of 100 khz and above falls below 0.1% f.s., and the current level falls abruptly as the frequency increases. This phenomenon can be explained by considering the equivalent circuit of a 1

motor that is connected to an inverter as a load (Fig. 2). The motor s winding can be thought of as an R-L load consisting of a resistance and inductance connected in series. Consequently, impedance grows at high frequencies, making it harder for current to flow. L Inverter output High power factor Low power factor Active Power [W] R Frequency Back electromotive force Fig. 2: Motor equivalent circuit (for 1 phase) Similarly, if we look at the power factor (cos θ) for the power of an R-L load, the power factor approaches a value of 1 when the frequency is low, for example for the fundamental wave and its harmonics. However, because inductive reactance becomes dominant at high frequencies such as the switching frequency and its harmonics, current exhibits lagging phase, resulting in a low power factor. The bottom half of Fig. 3 provides an enlarged view of the time axis for the inverter output voltage and current s up to the switching frequency region. The voltage is rectangular, while the current is triangular. It is apparent that their phase relationship is characterized by the current s lagging phase, as described above, resulting in a low power factor. 1k 10k Fundamental Frequency and harmonics 100k 1M [Hz] Switching Frequency and harmonics Fig. 4: Principal components of inverter output active power and their characteristics 3. Performance required for highprecision measurement of inverter output This section describes the requirements that a power measuring instrument must satisfy in order to accurately measure inverter output power. Based on the characteristics described above, it is important that such an instrument be capable of measuring active power not only for a high-power-factor fundamental wave and its harmonics, but also for a low-power-factor switching frequency and its harmonic components. Power factor 1 Power factor 0 Q Q Phase error Phase error θ Active power Fig. 3: Enlarged view of inverter output s P Error θ Active power P Error Fig. 5: Relationship between phase error and active power error at different power factors Fig. 5 illustrates the relationship between phase error and active power error at different power factors. and current phase error in the measurement circuit has a greater effect on active power at low power factors than at high power factors. Consequently, accurate 2 2017 HIOKI E.E. CORPORATION A_TA_PW0008E01

measurement of active power at the switching frequency and its harmonic components requires both flat amplitude characteristics and flat phase characteristics across a broad frequency band (the latter being particularly important). For power components that consist of a rectangular-wave voltage and triangular-wave current as shown in Fig. 3, the frequency band across which the instrument must exhibit flat amplitude and phase characteristics in order to measure efficiency at a precision of 0.1% is likely 5 to 7 times the switching frequency 1). Active power frequency characteristics at a power factor of zero provide a yardstick for measuring flat amplitude and phase performance. Fig. 6 provides example active power frequency characteristics at a power factor of zero for several Hioki Power Analyzer models. Please note that these example characteristics describe the instruments standalone performance. a current sensor to measure currents that exceed 5 A 2). Consequently, in order to implement a power measurement system whose flat amplitude and phase characteristics extend to high frequencies, it is necessary to satisfy the above performance requirements not for the power analyzer on a standalone basis, but rather when the power analyzer and current sensor are used in combination. However, current sensors typically exhibit gradually increasing phase error in the high-frequency region due to the characteristics of the sensor s magnetic core and circuitry. Furthermore, differences in the design of various sensor models cause the magnitude of this error to vary. Fig. 7 illustrates example phase characteristics for several Hioki high-precision current sensors. Fig. 7: sensor phase-frequency characteristics Fig. 6: Example active power frequency characteristics at a power factor of zero for Hioki Power Analyzers The PW6001 delivers flat characteristics up to 1 MHz, reflecting its envisioned use case of measuring inverters that use SiC switching elements. The PW3390, which is designed to measure inverters that use IGBT switching elements, provides flat characteristics up to 150 khz. The instrument is designed to surpass the performance of the 3390, the previousgeneration model, in order to facilitate high-precision measurement of inverter output. 4. sensor phase correction When a power analyzer is used in a high-precision power measurement application, it is typical to utilize The current sensor phase correction functionality provided by the Hioki Power Analyzer PW6001 and PW3390 can be used to resolve this issue. Phase correction uses current sensor-specific phase error information to correct the error, thereby improving phase characteristics in the high-frequency region and reducing power measurement error. The phase correction function utilizes virtual oversampling technology to perform real-time deskew processing for sampled s at a high time resolution equivalent to a frequency that is 400 times higher than the actual sampling frequency. By performing delay compensation for s using the concept of time, phase correction benefits can be extended across the full frequency band. Hioki develops high-precision current sensors inhouse, and it has ascertained the phase characteristics of each sensor model by optimizing design and manufacturing 3

processes and by implementing strict production control. The current sensor-specific phase characteristics information used in phase correction can be found in the user manual of each Hioki power analyzer. Fig. 8 illustrates the result of performing phase correction for the current sensors shown in Fig. 7 using that phase characteristics information. Performed properly, phase correction yields significantly better phase characteristics in the high-frequency region. the 3390 with phase correction disabled. The difference in values was likely due to the instruments superior active power frequency characteristics at a power factor of zero (Fig. 6). Efficiency values with phase correction enabled were another 0.1% to 0.15% greater than those obtained with the function disabled. Fig. 10 illustrates the DC input power P4 and the PWM output power P123 for the measurements shown in Fig. 9. Whereas the P4 values from the PW6001 and PW3390 remained unchanged regardless of whether phase correction was enabled or disabled, P123 values were 0.1% to 0.15% greater when phase correction was enabled compared to when it was disabled. Based on these results, the reduction in the CT6862 current sensor s lagging phase error (Fig. 7 and Fig. 8) is readily apparent in the P123 measured values. Fig. 8 Phase-frequency characteristics following phase correction 5. Comparison of actual inverter efficiency measurements The authors measured the efficiency of the SiC inverter described in Table 1 above using three Hioki Power Analyzer models and compared the results. Table 2 summarizes the measurement conditions. Separate measurements using the PW6001 and PW3390 were performed with phase correction enabled and disabled. Fig. 9: Comparison of inverter efficiency and loss by model Input (DC) Output (PWM) Item Model PW6001 PW3390 3390 Wiring 1P2W Sensor CT6862 Phase Correction OFF/ ON (-10.96deg@300kHz) N/A Wiring 3P3W3M Sensor CT6862 3 Phase Correction OFF/ ON (-10.96deg@300kHz) N/A Fundamental Frequency 100 Hz Power Analyzer Frequency band to 2 MHz to 200 khz to 150 MHz Table 2: Measurement conditions Fig. 9 summarizes the measurement results for efficiency and loss. Both the PW6001 and PW3390 yielded efficiency values that were 0.1% to 0.15% greater than Fig. 10 Comparison of inverter input and output power by model 4

Finally, a comparison of the loss values shown in Fig. 9 reveals that loss values obtained from the PW6001 and PW3390 with phase correction enabled were 0.1 W (equivalent to 12%) lower than values from the 3390. This test measured a small motor as its load, but a 12% difference in loss for a 10 kw, 95% efficient inverter would be equivalent to 60 W of power, a difference large enough to have an impact on thermal design. To accurately evaluate efficiency down to the 0.1% level and loss to the 1 W level in a high-efficiency motor drive system, it is important to ensure that the entire power measurement system has appropriate amplitude and phase characteristics. The authors measurement results illustrate the effectiveness of current sensor phase correction. Because the measured inverter used a switching frequency of 20 khz, both the PW6001 and PW3390 had an adequate frequency band, and there were no significant differences in the measurement results from the two instruments. However, differences between the two models are expected if the switching frequency increased further. 3) Hayashi, K, Measurement of Loss in High-Frequency Reactors, Bodo s Power Systems, February 2017, pp.18-22. 6. Conclusion This paper focused on inverter output power, outlining the requirements for power measuring instruments in order to facilitate accurate measurement. It identified the importance of current sensor phase correction expertise in fulfilling those requirements and verified the effectiveness of that technique by comparing actual measurements. In the field of power electronics, there are numerous opportunities for measuring power at high frequencies and low power factors 3) apart from motor drive systems, and phase correction expertise can be effectively utilized in those applications. We look forward to providing more useful information about this topic to readers in the future. References 1) Hayashi, K, High-Precision Power Measurement of SiC Inverters, Bodo s Power Systems, September 2016, pp.42-47. 2) Yoda, H, et al. Measurement Methods that Deliver High Precision Power Analysis in the Field of Power Electronics Bodo s Power Systems, April 2016,pp.38-42. 5