Comparison and Implementation of Different PWM Schemes of Inverter with Induction Generator for Wind Generation

Similar documents
Analysis of Voltage Source Inverters using Space Vector PWM for Induction Motor Drive

Design and Development of MPPT for Wind Electrical Power System under Variable Speed Generation Using Fuzzy Logic

Modeling and Simulation of Induction Motor Drive with Space Vector Control

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

29 Level H- Bridge VSC for HVDC Application

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

A Novel Voltage and Frequency Control Scheme for a Wind Turbine Driven Isolated Asynchronous Generator

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

Voltage Regulated Five Level Inverter Fed Wind Energy Conversion System using PMSG

Power quality improvement of self- excited induction generator using Multipulse AC-DC converters - A comparison

Study on Voltage Controller of Self-Excited Induction Generator Using Controlled Shunt Capacitor, SVC Magnetic Energy Recovery Switch

Speed control of Induction Motor drive using five level Multilevel inverter

Speed Control of Induction Motor using Multilevel Inverter

Analysis of Hybrid Renewable Energy System using NPC Inverter

Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques

Overview of Wind Turbine Driven Self-Excited Induction Generator

A New Control Strategy for Three- Phase Inverter Applied To Induction Motor of Micro Grid

Stability of Voltage using Different Control strategies In Isolated Self Excited Induction Generator for Variable Speed Applications

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

Pak. J. Biotechnol. Vol. 13 (special issue on Innovations in information Embedded and communication Systems) Pp (2016)

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives

Performance Analysis of Induction Motor Drive Fed by VSI for Various Modulation Index

Voltage and Frequency Regulation in Wind Farm using Novel Boost Converter and MLI

Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method

The Amalgamation Performance Analysis of the LCI and VSI Fed Induction Motor Drive

Feed-Forward System Control for Solid- State Transformer in DFIG

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

CASCADED H-BRIDGE MULTILEVEL INVERTER FOR INDUCTION MOTOR DRIVES

Research Article. ISSN (Print) *Corresponding author T. Yuvaraja

Minimization Of Total Harmonic Distortion Using Pulse Width Modulation Technique

A Comparative Study of Sinusoidal PWM and Space Vector PWM of a Vector Controlled BLDC Motor

Reduction of Torque Ripple in Trapezoidal PMSM using Multilevel Inverter

Power Quality enhancement of a distribution line with DSTATCOM

Voltage Control of Variable Speed Induction Generator Using PWM Converter

ISSN: [Shukla* et al., 6(10): October, 2017] Impact Factor: 4.116

Frequency Variable Three Phase Inverter Connected to PWM to Control the Induction Motor

Induction Motor Drive using SPWM Fed Five Level NPC Inverter for Electric Vehicle Application

A Novel Five-level Inverter topology Applied to Four Pole Induction Motor Drive with Single DC Link

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai 1 Prof. C. A. Patel 2 Mr. B. R. Nanecha 3

Open Loop V/F Control of Induction Motor based on PWM Technique

Study of Unsymmetrical Cascade H-bridge Multilevel Inverter Design for Induction Motor

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

A Fifteen Level Cascade H-Bridge Multilevel Inverter Fed Induction Motor Drive with Open End Stator Winding

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

DESIGN OF A MODE DECOUPLING FOR VOLTAGE CONTROL OF WIND-DRIVEN IG SYSTEM

REDUCTION OF COMMON-MODE VOLTAGE IN OPEN END WINDING INDUCTION MOTOR DRIVE USING CARRIER PHASE-SHIFT STRATEGY

International Journal of Advance Engineering and Research Development

Power Electronics Converters for Variable Speed Pump Storage

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Power Factor Improvement with Single Phase Diode Rectifier in Interior Permanent Magnet Motor

COMPARATIVE STUDY ON CARRIER OVERLAPPING PWM STRATEGIES FOR THREE PHASE FIVE LEVEL DIODE CLAMPED AND CASCADED INVERTERS

CONTROL SCHEME OF STAND-ALONE WIND POWER SUPPLY SYSTEM WITH BATTERY ENERGY STORAGE SYSTEM

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE

Analysis of Hybrid Renewable Energy System using NPC Inverter

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

Self-Excitation and Voltage Control of an Induction Generator in an Independent Wind Energy Conversion System

An Induction Motor Control by Space Vector PWM Technique

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Comparative Analysis of Space Vector Pulse-Width Modulation and Third Harmonic Injected Modulation on Industrial Drives.

Bhanutej Jawabu Naveez Assistant Professor, Vignana Bharathi Institute of Technology, Aushapur, Ghatkesar, Hyderabad.

Simulation of Cascade H-Bridge Multilevel Inverter With Equal DC Voltage Source

FFT Analysis of THD in Distribution System with Grid Connected RES

Vector Approach for PI Controller for Speed Control of 3-Ø Induction Motor Fed by PWM Inverter with Output LC Filter

Simulation & Implementation Of Three Phase Induction Motor On Single Phase By Using PWM Techniques

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE

Simulation and Analysis of Space Vector PWM Inverter Fed Three Phase Induction Motor Drive

Integration of Two Flyback Converters at Input PFC Stage for Lighting Applications

Research Article International Journals of Advanced Research in Computer Science and Software Engineering ISSN: X (Volume-7, Issue-6)

PF and THD Measurement for Power Electronic Converter

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

High Efficiency Single Phase Transformer less PV Multilevel Inverter

Analysis of IM Fed by Multi-Carrier SPWM and Low Switching Frequency Mixed CMLI

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

International Journal of Advance Engineering and Research Development

SIMULATION AND IMPLEMENTATION OF CURRENT CONTROL OF BLDC MOTOR BASED ON A COMMON DC SIGNAL

Design of Three Phase SVPWM Inverter Using dspic

Modeling and Simulation of Wind Farm with STATCOM in PSCAD/EMTDC Environment

Space Vector Modulated Voltage Source Converter for Stand Alone Wind Energy Conversion System

Application of Sparse Matrix Converter for Microturbine-Permanent Magnet Synchronous Generator output Voltage Quality Enhancement

ISSN Vol.07,Issue.11, August-2015, Pages:

Application of Fuzzy Logic Controller in Shunt Active Power Filter

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering Vol. 2, Issue 6, June 2013

Three Phase Five Level Inverter with SPWM fed from Hybrid Renewable Energy Based Induction Motor Drive

Photovoltaic Grid-Connected System Based On Cascaded Quasi-Z-Source Network

MPPT for PMSG Based Standalone Wind Energy Conversion System (WECS)

Transcription:

Comparison and Implementation of Different PWM Schemes of Inverter with Induction Generator for Wind Generation Neha Kaushik 1,Dr. M. K. Soni 2, Ashish Grover 3 M.Tech (PSED), Dept. of EEE, ManavRachna International University, Faridabad, India. 1 Professor, Dept. of EEE & Dean FET, ManavRachna International University, Faridabad, India 2 Assistant Professor, Dept. of EEE, ManavRachna International University, Faridabad, India 3 ABSTRACT:Due to limited non-renewable energy sources, today we are focussing towards the advent use of renewable sources like wind, solar, tidal etc. wind is becoming the most promising one. In this paper the variable speed of wind turbine is controlled by interfacing induction generator with power electronics and different control techniques. This helps in reduction of fluctuations in variable speed wind turbine, harmonics and sinusoidal electrical energy to be penetrated in to the load/grid. Through the means of power electronics we can make wind energy a prime renewable energy source world-wide. Thus prelation of wind energy can also become a key to power system operation.[2]. Keywords:Wind energy, Induction generator, PWM, SVPWM, inverter, vector control. I.INTRODUCTION In recent years, wind energy has become one of the most important and promising sources of renewable energy, which demands additional transmission capacity and better means of maintaining system reliability. Conservation of nonrenewable resources motivate to explore the new avenues of resources for electricity generation which could be clean, safe and most valuable to serve the society for a long period. The installed capacity increased from a modest base of 41.3 MW in 1992 to reach 17,351MW by December 2012. The evolution of technology related to wind systems industry leaded to the development of a generation of variable speed wind turbines that present many advantages compared to the fixed speed wind turbines. Induction generators cannot generate power on their own without some form of reactive power for excitation which has to be provided through the stator winding. When the induction machine is driven by an external prime mover, the flux in the rotor induces a small voltage in the stator windings. The statorwinding voltage has a leading current if a suitable source of reactive power is connected to the terminal. The source of reactive power could be a synchronous generator, a bank of capacitors, or an inverter. II. RELATED WORK Previously many techniques related to SPWM and SVPWM is described which has solved issues of total harmonic distortion (THD) and also controlled active and reactive power. Most modern turbine inverters are forced commutated PWM inverters to provide a fixed voltage and fixed frequency output with a high power quality.the paper discuss about the various schemes of PWM along with vector control with IGBT inverter which has better computational time and also fixed the magnitude of voltage and current. III. WHY INVERTERS ARE PREFFERED? Today, most turbines operate at variable-speed, and the control system regulates the rotor speed to obtain peak efficiency in fluctuating winds by continuously updating the rotor speed and generator loading to maximize power and reduce drive train transient torque loads. Operating variable speed requires the use of inverters to make the generated power match the grid frequency. The inverter also enables turbines to deliver fault ride through protection, voltage control, and dynamic reactive power support to the grid.[1] Copyright to IJAREEIE www.ijareeie.com 9513

Fig.1 Wind energy conversion system The major components of a typical wind energy conversion system include a wind turbine, generator, interconnection apparatus and control systems, as shown in Fig.1. For wind generation ac-dc-ac inverters are combined with various advanced control techniques interfaced with power electronics devices. This progressively helps in variable speed operation. In this way electrical grid frequency and mechanical rotor speed is separated. The accurate controls of voltage and frequency can limit the electrical and mechanical stresses in the power system and delivering good quality energy. Various PWM techniques used to obtain the required voltage in inverter terminals. The variable output voltage of the generator is rectified and inverted using the PWM inverter. The modulation index adjusted such that the voltage at the output has maintained.[3] IV. TYPES OF WIND TURBINE Wind turbines are basically classified into two types namely 1. Fixed speed wind turbine 2. Variable speed wind turbine I Fixed speed wind turbine(type 1) The fixed-speed wind turbine consists of a rotor and an induction generator directly connected to grid via gear box shown in fig.2.it contributes to system frequency support because each wind turbine generator (WTG) is directly connected to the power grid. The generator slip is varied so speed is not or speed variation is very small (1-2%) so this is called fixed-speed wind turbine.[5] II Variable speed wind turbine(type 2) Variable speed configurations provide the ability to control the rotor speed. Variable speed operation can only be achieved by decoupling electrical grid frequency and mechanical rotor frequency shown in fig.2. To this end, power electronic converters are used, such as an AC-DC-AC converter combined with advanced control systems. Fig. 2 Construction of type 1 & type 2 turbine system[5] The following advantages of Variable speed wind turbine over Fixed speed wind turbine are as follows: Copyright to IJAREEIE www.ijareeie.com 9514

The Annual Energy Production (AEP) increases because the turbine speed can be adjusted as a function of wind speed to maximize output power. Depending on the turbine aerodynamics and wind regime, the turbine will on average collect up to 10% more annual energy. The mechanical stresses are reduced due to the compliance to the power train. The turbulence and wind shear can be absorbed, i.e., the energy is stored in the mechanical inertia of the turbine, creating a compliance that reduces the torque pulsations. The output power variation is somewhat decoupled from the instantaneous condition present in the wind and mechanical systems. When a gust of the wind arrives at the turbine, the electrical system can continue delivering constant power to the network while the inertia of mechanical system absorbs the surplus energy by increasing rotor speed. Comparison shown in fig.3. Power quality can be improved by reduction the power pulsations. This allows increasing the penetration of the wind power in the network.[6] Fig. 3 Real Power vs. Rotor Speed of type 1 & type 2 turbine V. METHODOLOGY In this paper the four different PWM control strategies has been discussed. Different inverters are used with induction generator which is used to control the wind turbine. They are as follows SPWM(Sinusoidal Pulse Width Modulation) with universal bridge PWM(Pulse Width Modulation) with IGBT inverter SV PWM(Space Vector Pulse Width Modulation) with MOSFET inverter Vector Control with IGBT inverter A. SPWM with universal bridge The system consists of two independent circuits illustrating two three-phase two-level PWM voltage source inverters. Each inverter feeds an AC load (1 kw, 500 var 60Hz @ 208V rms). Three phase universal bridge rectifier is used to convert the variable voltage and variable frequency at the induction generator terminal into rectified dc voltage converters are controlled in open loop with the Discrete PWM Generator. The simulated result shown in Fig.4 shows the input PWM voltage and the simulated output load voltage. The output voltage is in the form of pulses. Fig. 4 Three-phase input voltage and output load voltage Copyright to IJAREEIE www.ijareeie.com 9515

B. PWM with IGBT inverter Fig.5 shows a 60 Hz, induction machine feeds a 50 Hz, 50 kw load through an AC-DC-AC converter. The filtered DC voltage is applied to an IGBT two-level inverter generating 50 Hz. The IGBT inverter uses Pulse Width Modulation (PWM) at a 2 khz carrier frequency. The load voltage is regulated at 1 pu (380 V rms) by a PI voltage regulator using abc_to_dq and dq_to_abctransformations. The first output of the voltage regulator is a vector containing the three modulating signals used by the PMW Generator to generate the 6 IGBT pulses. The second output returns the modulation index. The Multimeter block is used to observe diode and IGBT currents. In steady state, the mean value of the modulation index is m = 0.80 and the mean value of the DC voltage is 778 V. The fundamental component of 50 Hz voltage buried in the chopped inverter voltage is therefore: Vab = 778 V * 0.612 * 0.80 = 381 V rms Fig. 5 Simulink model of Induction Machine PWM IGBT Inverter Fig. 6DC Voltage, Inverter Output Voltage, Load Output Voltage & Modulation Index of IGBT The filtered dc voltage is applied to IGBT is shown in fig.6 above than inverter output voltage is shown in pulse form. After that output load voltage is shown and then modulation index is maintained at 1. The output voltage is improved than in the above scheme as it is becoming steady and constant with time. Copyright to IJAREEIE www.ijareeie.com 9516

Fig.7 Switching time of Diode 1&3 and IGBT 1&3 Fig.7 shows the switching time of diode (above) and IGBT (below). The pink pulse shows switching time of diode 1 and IGBT 1 respectively in both the graphs and switching time shown in yellow I of diode 3 and IGBT 3. C. SV PWM with MOSFET inverter A 3-phase squirrel-cage induction generator rated 3 HP, 220 V, 60 Hz, 1725 rpm fed a 3-phase MOSFET inverter connected to a DC voltage source of 325 V. The inverter is modelled using the "Universal Bridge" block and the "Asynchronous Machine" block. Its stator leakage inductance Lls is set to twice its actual value to simulate the effect of a smoothing reactor placed between the inverter and the machine. The load torque applied to the machine's shaft is constant and set to its nominal value of 11.9 N.m. The firing pulses to the inverter are generated by the "Space-Vector PWM modulator" block. Speed control of the machine is performed by the "Constant V/Hz" block. The magnitude and frequency of the stator voltages are set based on the speed set point. By varying the stator voltages magnitude in proportion with frequency, the stator flux is kept constant. Fig. 8 Stator input Voltage & Stator input Current of Induction Machine Fig. 8 shows the stator input voltage which is 320Vrms. The graph below shows the stator input current of induction machine. Results came from the Simulink model whose description is given above. Copyright to IJAREEIE www.ijareeie.com 9517

Fig. 9 Speed, Output Voltage, Frequency & Torque of Induction machine Fig.9 shows the speed of the machine which is 1720rpm. The second graph shows the output voltage which is 220 Vrms. Next graph shows the frequency maintained at 60Hz and last graph shows the variation of electromagnetic torque. Here the maximum effective use of input stator voltage is done which made this scheme best among all above. The THD reduction is maximum in this case. D. Vector Control with IGBT inverter The induction machine is fed by a current-controlled PWM inverter. The speed control loop uses a proportionalintegral controller to produce the quadrature-axis current reference iq* which controls the torque. A vector-control approach is used, with a reference frame oriented along the stator (or supply) voltage vector position, enabling independent control of the active and reactive power flowing between the supply and the supply-side converter. The PWM converter is current regulated, with the direct axis current used to regulate the DC-link voltage and the quadrature axis current component used to regulate the reactive power. Fig.10 shows the Simulink model of vector control with IGBT inverter based on above description. Fig. 10 Simulink Model of Vector Control PWM of Induction Machine Copyright to IJAREEIE www.ijareeie.com 9518

Fig. 11 Output Voltage, Output current, Rotor speed & Torque of Induction machine Fig.11 shows the output voltage of vector control in the form of pulses. The output current shown is more in the starting and then it decreases to a constant value. The rotor speed of the induction machine is increased and maintained constant at higher value according to which the torque is also maintained constant after some time. As the constant output voltage and current is achieved in this scheme this makes it better than SVPWM also. VI. COMPARISION Modulation Index- The modulation index is almost constant for PWM with IGBT Inverter, higher for SVPWM as compared to SPWM. Computation time- The computation time of vector control takes least time than other scheme. After that SVPWM method takes then PWM scheme and lastly SPWM. Output Voltage - The output voltage is about 15% more in case of SVPWM as compared to SPWM. The output voltage of PWM with IGBT Inverter is less than SVPWM and reaches steady state with time and vector control PWM has highest output voltage. Output current- The output current much less in case of SVPWM then any other method. Torque torque harmonics produced are much less in case of SVPWM. However despite all the above mentioned advantages that SVPWM enjoys over SPWM, SVPWM algorithm used in three-level inverters is more complex because of large number of inverter switching states. Hence we see that there is a certain trade off that exists while using SVPWM for inverters for Adjustable speed Drive Operations. Due to this we have to choose carefully as to which of the two techniques to use weighing the pros and cons of each method. Copyright to IJAREEIE www.ijareeie.com 9519

VII. CONCLUSION After study of these kinds of variable speed wind turbines, and how the control techniques actually work on power electronic interface shows really interesting results. All the PWM methods mentioned in this paper are far best for wind turbines to reduce THD and to produce sinusoidal electrical energy. As study reveals Space vector PWM generates less harmonics distortion in current or voltage in comparison with sine PWM but the computation time of vector control is comparatively less. The speed is also become constant after a raise. Space vector provides more efficient use of supply voltage in comparison with Sine PWM [3]. As torque is concerned vector control has maximum. So vector control method can be used over SVPWM and SPWM. REFERENCES [1] Blaabjerg, Z. Chen, R. Teodorescu, F. Iov Aalborg University institute of Energy Technology Power Electronics in Wind Turbine Systems 1-4244-0449-5/06/$20.00 2006 IEEE [2] Juan Manuel Carrasco, Jan T. Bialasiewicz,, Ramón C. Portillo Guisado, José Ignacio León, Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 53, NO. 4, AUGUST 2006 [3] NitinAdhav, Pg Student ShilpaAgarwal Comparison and Implementation of Different PWM Schemes of Inverter in Wind Turbine International Journal of Innovative Technology and Exploring Engineering (IJITEE) ISSN: 2278-3075, Volume-2, Issue-2, January 2013 [4] S. M. Barakati, M. Kazerani, Senior Member, IEEE, and X. Chen A new wind turbine system based on matrix converter 0-7803-9156- X\\05\$20.00@2005 IEEE [5] Inside Wind turbine fixed Vs. Variable james and james Science publishers ltd. [6] NitinAdhav A concept of Smart grid and control Schemes in variable power source wind turbine International journal of engineering and research Application Vol. 2, Issue 4, July-August 2012, pp.579-584 [7] Swati Devabhaktuni1* S.V.Jayaram Kumar2, Modeling and Analysis of Wind turbine Driven Self-Excited Induction Generator Connected to Grid Interface with Multilevel H-Bridge Inverter, Journal of Energy Technologies and Policy ISSN 2224-3232 (Paper) [8] B. Palle, M.G. Simoes, F.A. Farret: Dynamic Simulation and Analysis of Parallel Self-Excited Induction Generators for Islanded Wind Farm Systems, IEEE Trans. on Industry Applications, Vol. 41, No. 4, 2005, pp. 1099 1106. [9] D. Seyoum, C. Grantham and F. Rahman, Novel Analysis and Modeling of an Isolated Self-ExcitedInduction Generator Taking Iron Loss into Account, IEE Proc. B, Vol. 136, No. 2, pp. 61-68, March 1989. [10] D. Basset, F.M. Potter: Capacitive Excitation of Induction Generators: Trans. Amer. Inst. Electric. Eng., 54, 1935, pp. 540 545. [11] A.M.Gole 2000 power electronics Sinusoidal Pulse Width Modulation [12] Power Electronics and Drives (Version 2): Dr. Zainal Salam, 2002 4.4.1 SPWM [13] D.Dujic, E.Levi, M.Jones Liverpool John Moores University School of Engineering [14] G.Grandi, G.Serra, A.Tani University of Bologna Department of Electrical Engineering 40136 - Bologna, Italy Liverpool L3 3AF, UK Continuous PWM Techniques for Sinusoidal Voltage Generation with Seven-Phase Voltage Source Inverters 1-4244-0655-2/07/$20.00 2007 IEEE [15] J. Holtz, Pulse width modulation for electronic power conversion, Proc. IEEE, vol. 82, pp. 1194 1214, Aug. 1994. [16] O. Ogasawara, H. Akagi, and A. Nabel, A novel PWM scheme of voltage source inverters based on space vector theory, in Proc. EPE European Conf. Power Electronics and Applications, 1989, pp. 1197 1202. [17] M. Depenbrock, Pulsewidth control of a 3-phase inverter with nonsinusoidal phase voltages, in Proc. IEEE-IAS Int. Semiconductor Power Conversion Conf., Orlando, FL, 1975, pp. 389 398. [18] J. A. Houldsworth and D. A. Grant, The use of harmonic distortion to increase the output voltage of a three-phase PWM inverter, IEEE Trans. Ind. Applicat., vol. 20, pp. 1224 1228, Sept./Oct. 1984.P. K. Visscher, How Self-Organization Evolves, Nature, vol. 421, pp. 799 800 Feb.2003. Copyright to IJAREEIE www.ijareeie.com 9520