LM Test Report. For. Beyond LED Technology Parker Ct Stone Mountain, GA Epic Series LED Pole Light

Similar documents
LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

REVOLUTION LIGHTING TECHNOLOGIES INC

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

Eternal Shine Technology Co.,Ltd. EST

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

RoHS. Model: VAC 50/60HZ.83A Max 100W

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

RoHS QPL ID # PLC6V1PABNUJS

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Morris Products 53 Carey Road, Queensbury, NY 12804

Cat# LED High Bay

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

Dimming: PWM/TIME/0-5V/0-10V. RoHS

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

QPL ID # PLG2YNJ831VZ


71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A


Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

71352A QPL ID # PLT2P2L2UNWR. RoHS

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

Cat# 71440A LED Classic Large Wall-Pack

Cat# 71146A 150W Trunion Mount

Cat# LED Classic MINI Wall-PACK

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

Cat# LED Wall-PACK

LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

LM Test Report

LM Test Report

LM Test Report

LM Test Report

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

Photometric Test Report

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Photometric Test Report

Photometric Test Report

Photometric Test Report

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

Photometric Test Report

Morris Products 53 Carey Road, Queensbury, NY 12804

Cat# LED Classic Large Wall-Pack

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Photometric Test Report

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Transcription:

LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 1939 Parker Ct Stone Mountain, GA 30087 Epic Series LED Pole Light Model name(s): BLT-XSB-300W-50K-TPIII-SBA Remark: XXK stands for different CCT as bellow: 40K=4000K, 50K=5000K, 57K=5700K. YYY stands for different lens, it can be 90=90 lens, 713=70*135, II=TP II, III=TP III, IV=TP IV, V=TPV. Z stands for different LED chip as bellow: L=Nichia 757, S= Seoul 3030. T stands for different power supply as bellow: B=MEANWELL dimmable HLG series. D=INVENTRONICS EUD series, E=INVENTRONICS ESD series, K=INVENTRONICS EUK series, S=SOSEN series. A stands for different mounting arm: S=slip fitter arm, E=extruded arm, U=u bracket, W=wall mount arm, Y=yoke arm, F=flat arm. Representative (Tested) Model: BLT-XSB-300W-50K-TPIII-SBA Model Difference: All construction and rating are the same, except CCT. Test & Report By: Jack Luo Review By: Engineer: Jack Luo Date: Nov.01,2017 Manager: Tommy Liang 1 / 9

Note: 1. The results contained in this report pertain only to the rested samples. 2. This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. 2 / 9

1.1 Product Information: Organization Name Beyond LED Technology Brand Name Beyond LED Model Number BLT-XSB-300W-50K-TPIII-SBA SKU (if available) 150317 Type of Luminaire (for integral lamps, list base type and lamp type) Epic Series LED Pole Light Rated Voltage / Frequency 120-277 Vac, 50/60 Hz Nominal Power 300W Rated Initial Lamp Lumen -- Declared CCT 4000K,5000K,5700K LED Manufacturer Seoul Semiconductor Co., LTD LED Model SAWxC22B-xx Sample Number GZE1709061-AN1 Lamp Length -- mm Lamp Width -- mm Number of Units (modular products) N/A s Photo 3 / 9

1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard Reference Work Instruction Oct.22,2017 Oct.25,2017 1. Total Luminous Flux 2. Luminous Distribution Intensity 3. Luminous Efficacy 4. Electrical Parameters 1. IES LM-79-2008 Electrical and Photometric Measurements of Solid-State Lighting Products 2. IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED) Sources and Systems QD25 1.3 Test Methods 1) Photometric and Light Distribution Measurement Goniophotometer Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1 vertical intervals and 22.5 horizontal intervals. 2) Electrical Measurements: Electrical parameters were measured using power meters incorporated in goniophotometer or sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at 25ºC ± 1ºC. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion were measured by and read from the power meter. 4 / 9

2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date 2017-10-25 Test Ambient: 25.2 ºC Test Orientation Horizontal Stabilization Time (min) 90 Model Number BLT-XSB-300W-50K-TPIII-SBA Electrical Measurement: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE170906 120.0 60 2.504 299.5 0.9969 5.20 1-AN1 277.0 60 1.096 287.6 0.9476 8.72 DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Photometric Measurement Goniophotometer Method: Parameter Result DLC V4.2 Pass Criteria Test Voltage (V) 120.0 277.0 Frequency (Hz) 60 60 -- Total Luminous (lm) 42983 41805 >=1000(-10%) Luminous Efficacy (lm/w) 143.52 145.36 Standard: >= Premium: >= Most Worst Luminous/Highest Watts 139.58 100(-3%) 120(-3%) Zonal lumens in the 0-90 zone (%) 99.8 -- >= 100(-1) Zonal lumens in the 80-90 zone (%) 1.7 -- <= 10(+3) Beam Angle ( ) 139.9 -- -- Center Beam Candle Power (cd) 8949 -- -- 5 / 9

Zonal Lumen Tabulation Zonal Lumen Summary Lumens Per Zone Zone Lumens % Luminaire Zone Lumens % Total Zone Lumens % Total 0-30 7,778.3 18.1% 0-40 13,807.7 32.1% 0-60 29,310.0 68.2% 60-90 13,561.3 31.6% 70-100 5,763.2 13.4% 90-120 48.7 0.1% 0-90 42,871.3 99.8% 90-180 106.5 0.2% 0-180 42,977.8 100% 0-10 855.3 2.0% 90-100 12.9 0% 10-20 2,577.9 6.0% 100-110 16.6 0% 20-30 4,345.0 10.1% 110-120 19.1 0% 30-40 6,029.4 14.0% 120-130 18.2 0% 40-50 7,344.2 17.1% 130-140 14.7 0% 50-60 8,158.1 19.0% 140-150 10.7 0% 60-70 7,811.0 18.2% 150-160 7.7 0% 70-80 5,005.2 11.6% 160-170 4.7 0% 80-90 745.2 1.7% 170-180 1.9 0% 6 / 9

Photometric Data 7 / 9

8 / 9

3. Test Equipment Equipment ID Equipment Name Last Calibration Date Next Calibration Date GO-R5000 Goniophotometer system 2017-07-01 2018-06-30 D908S Standard Lamp 2017-07-12 2018-07-11 PF210 Power Meter for Goniophotometer 2017-07-07 2018-07-06 ST-R-181A Temperature Tester 2017-07-01 2018-06-30 Uncertainty: Photometric Measurement(Goniophotometer):1.62% ****** END OF REPORT ****** 9 / 9