E-STOP relays, safety gate monitors

Similar documents
Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

PNOZ X3. } Safety relays. Operating Manual EN-08

PNOZ X2.7P. } Safety relays. Operating Manual EN-19

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

02/11/2015

Datasheet - PROTECT-IE-02

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

02/11/2015

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

05/09/2012

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

PSR-SCP- 24DC/ESD/5X1/1X2/300

02/11/2015

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

02/11/2015

Electronic Circuit Breaker with reset input ESS20-1..

38 Series - Relay Interface Modules A

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

08/07/2015

Switching power supplies CP range, Linear power supplies CP-L range. Content

Type CP-S, CP-C & CP-A Switch mode

PHOENIX CONTACT - 09/2009

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

08/07/2015

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Subject to changes 11/2003 Page 1/7

Installation / Monitoring Technique

Electronic Circuit Breaker ESS20-0..

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

For Immediate Delivery call KMParts.com at (866)

PHOENIX CONTACT

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

Electronic Circuit Breaker ESS1 for System SVS1

RE17LLBM asymmetrical flashing relay s V AC - solid state output

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

MINI-PS AC/2X15DC/1

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Safety switches with slotted hole lever

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

02/11/2015

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-TGD.22

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

Electronic Circuit Protector ESX10-T

MINI-PS AC/24DC/1.3

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Solid-state Timer H3DS

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Installation and Operating Instructions for Phase Demodulator Type _.2

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

QUINT-PS-24DC/24DC/10

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

3 - Protection components Circuit-breakers

Advantages. Applications

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Switching Power Supply Type SPP1 60W Enclosed type

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Installation and Operational Instructions for ROBA -switch Type 017._00.2

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Installation- / Monitoring Technique

FM series position switches

CP-T range Product group picture

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

PHOENIX CONTACT

Multifunctional counter tico 772/773/774

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Pulse Scaler for DIN Rail Attachment

38 Series - Relay interface modules A. Features /

Datasheet. Electronic Circuit Protection ESX10-T

Power Supplies 3. SDN-C Compact DIN Rail Series

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Protection components

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

05/09/2014

ISOMETER IRDH575. Approvals

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Transcription:

Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel 1/2 Supply voltage See order reference for unit types The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. Safety relay for monitoring E-STOP pushbuttons. Approvals Unit description The safety relay meets the requirements of EN 60204-1 and IEC 60204-1 and may be used in applications with E-STOP pushbuttons The safety relay is not suitable for noncontact barriers because a dynamic start is not possible the unit can be started during the delay-on de-energisation time. Safety features The relay conforms to the following safety criteria: Block diagram A1 A2 Y1 Y2 ~ ( )* = Input Reset/ Start K1 Power K2 ( )* *Only when U B = 42-240 VAC Galvanic isolation only when U B = 42 240 VAC

Up to Category 2, EN 954-1 Key Terminal configuration S1 S3 E-STOP pushbutton Reset button Switch operated U B = 24 VAC/DC A1 13 23 Gate open Gate closed POWER CH.1/CH.2 Y1 Y2 19681 A2 U B AC A1 13 23 POWER CH.1/CH.2 Y1 Y2 19686 A2 Installation Dimensions The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). 121 (4.8") 75 (2.95") 87 (3.42") 22,5 (0,89") -4

Notice Service life graph This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 AC15: 230 V DC13: 24 V DC1: 24 V AC1: 230 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 E Número de ciclos x 10 3 GB Cycles x 10 3 I Numero dei cicli di commutazione x 10 3 F Nombre de manœvres x 10 3 NL Aantal schakelingen x 10 3 Technical details Electrical data Supply voltage Supply voltage U B AC 24 V, 42 V, 48 V, 110 V, 115 V, 120 V, 230 V, 240 V Supply voltage U B DC 24 V Voltage tolerance -15 %/+10 % Power consumption at U B AC 5.0 VA Power consumption at U B DC 2.5 W Frequency range AC 50-60 Hz Residual ripple DC 160 % Voltage and current at input circuit DC: 24.0 V 50.0 ma reset circuit DC: 24.0 V 35.0 ma feedback loop DC: 24.0 V 20.0 ma Output contacts in accordance with EN 954-1 Category 4 Safety contacts (N/O): 3 Auxiliary contacts (N/C): 1 Utilisation category in accordance with EN 60947-4-1 AC1 at 240 V P max : 2000 VA DC1 at 24 V P max : 200 W AC1 at 240 V P max : 2000 VA DC1 at 24 V P max : 200 W Utilisation category in accordance with EN 60947-5-1 AC15 at 230 V I max : 5.0 A DC13 at 24 V (6 cycles/min) I max : 6.0 A AC15 at 230 V I max : 5.0 A DC13 at 24 V (6 cycles/min) I max : 6.0 A Contact material AgSnO2 + 0.2 µm Au -35

Electrical data External contact fuse protection to EN 60947-5-1 Blow-out fuse, quick 10 A 10 A Blow-out fuse, slow Circuit breaker 24 VAC/DC, characteristic B/C Semiconductor outputs (short circuit proof) 24.0 V DC, 20 ma External supply voltage 24.0 V DC Voltage tolerance -20 %/+20 % Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 150 Ohm single-channel at U B AC 180 Ohm dual-channel with detect. of shorts across contacts at U B DC 15 Ohm dual-channel with detect. of shorts across contacts at U B AC 30 Ohm Times Switch-on delay with automatic reset typ. 2 with automatic reset max. 500 ms with automatic reset after power on typ. 280 ms with automatic reset after power on max. 5 with monitored reset typ. 35 ms with monitored reset max. Delay-on de-energisation with E-STOP typ. 15 ms with E-STOP max. 30 ms with power failure typ. with power failure max. 70 ms Recovery time at max. switching frequency 1/s after E-STOP after power failure 100 ms Waiting period with a monitored reset 300 ms Min. start pulse duration with a monitored reset 30 ms Simultaneity, channel 1 and 2 Supply interruption before de-energisation 20 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2 Vibration in accordance with EN 60068-2-6 Frequency 10-55 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78 Airgap creepage VDE 0110-1 Ambient temperature -20-55 C Storage temperature -40-85 C Protection type Mounting (e.g. control cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0-36

Mechanical data Max. cross section of external conductors with screw terminals 1 core flexible 0.20-4.00 mm², 24-10 AWG 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.20-2.50 mm², 24-14 AWG without crimp connectors or with TWIN crimp connectors 0.20-2.50 mm², 24-14 AWG Torque setting with screw terminals 0.60 Nm Dimensions Height 87.0 mm Width 45.0 mm Depth 121.0 mm Weight 375 g The standards current on 08/02 apply. Max. continuous current Number of contacts I max (A) at U B DC I max (A) at U B AC 1 8.00 A 8.00 A 2 8.00 A 7.50 A 3 7.00 A 6.50 A Order reference Type Features Terminals Order no. 24 VAC/DC 24 VDC Screw terminals 774 310 42 VAC 24 VDC Screw terminals 774 311 48 VAC 24 VDC Screw terminals 774 312 110 VAC 24 VDC Screw terminals 774 314 115 VAC 24 VDC Screw terminals 774 315 120 VAC 24 VDC Screw terminals 774 316 230 VAC 24 VDC Screw terminals 774 318 240 VAC 24 VDC Screw terminals 774 319-37