Jameco SKU Number: 668799 65W Dual Output Switching ower Supply RD-65 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION ENIRONMENT OTHERS NOTE OUTUT NUMBER DC OLTAGE RATED CURRENT CURRENT RANGE EAK LOAD RATED OWER OUTUT OWER (max.) OLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD U TIME (Typ.) OLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OERLOAD WORKING TEM. WORKING HUMIDITY STORAGE TEM., HUMIDITY RD-65C 12 5 4.5A 1.2A 0 ~ 5.8A 0 ~ 1.5A Note.4 7.5A Rated load 3.75A 60W RILE & NOISE (max.) Note.2 120mp-p OLTAGE TOLERANCE Note.3 OER OLTAGE EMS IMMUNITY CH1 Rated output power for convection; 77W with 18CFM min. forced air CH1:11.4 ~ 12.8 2.0 2.0 50mp-p 5.0 1.0 1.0 800ms, 20ms at full load 20ms at full load 90 ~ 264AC 127 ~370DC 47 ~ 440Hz 79 1.5A/115AC 0.9A/230AC COLD START 25A/115AC <1mA 90 ~ 125W output power CH1:13.8 ~ 16.2 5.0 50A/230AC rotection type : Hiccup mode, recovers automatically after fault condition is removed. rotection type : Hiccup mode, recovers automatically after fault condition is removed. -20 ~ +60 (Refer to output load derating curve) 20 ~ 90 RH non-condensing -40 ~ +85, 10 ~ 95 RH RD-65D CH2 CH1 CH2 TEM. COEFFICIENT 0.04/ (0 ~ 50 ) on CH1 output IBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TU EN60950-1 approved WITHSTAND OLTAGE I/-O/:3KAC I/-FG:1.5KAC O/-FG:0.5KAC SAFETY & ISOLATION RESISTANCE I/-O/, I/-FG, O/-FG:100M Ohms/500DC EMC (Note 4) EMI CONDUCTION & RADIATION Compliance to EN55022 (CISR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN50204, EN55024, light industry level, criteria A MTBF 288.1K hrs min. MIL-HDBK-217F (25 ) DIMENSION CB:127*76*28mm (L*W*H) with optional CASE:130*84.4*37mm (L*W*H) ACKING 0.24Kg; 63pcs/16Kg/1.35CUFT 24 81 5 2.25A 1.2A 0 ~ 2.9A 0 ~ 1.5A 60W 150mp-p CH1:22.8 ~ 26.4 2.0 1.0 2.0 CH1:27.6 ~ 32.4 Rated load 50mp-p 5.0 1.0 5.0 File Name:RD-65-SEC 2008-03-25
37 18 Jameco SKU Number: 668799 65W Dual Output Switching ower Supply RD-65 s e ries Mechanical Specification Case No. 946A Unit:mm 127 Optional cover: No. 946A-T 115.8 5.6 76 64.8 5.6 FS1 CN2 6 5 4 3 2 1 1 2 3 CN1 SR1 4-3.8 15cm 18CFM min. (60W convection, 77W with FAN) 7.1 115.8 2-M3 FAM 84.4 4-M3 L=4 29mm(max) 6-M3 L=4 3 max. 130 78 26 62 41.7 68.6 8.2 17 Optional L-Bracket: No. 946A-D AC Input Connector (CN1) : Molex 5273-03 or equivalent in No. Assignment Mating Housing Terminal 1 AC/L 2 Molex 5195 Molex 5194 No in or equivalent or equivalent 3 AC/N DC Output Connector (CN2) : Molex 5273-06 or equivalent in No. 1,2 3,4 5 6 Assignment 1 GND 2 NC Mating Housing Molex 5195 or equivalent Terminal Molex 5194 or equivalent Block Diagram fosc : 65KHz I/ EMI FILTER RECTIFIERS & FILTER OWER SWITCHING RECTIFIERS & FILTER + FG RECTIFIERS & FILTER +5 COM O.L.. WM CONTROL DETECTION CIRCUIT O... File Name:RD-65-SEC 2008-03-25
Jameco SKU Number: 668799 65W Dual Output Switching ower Supply RD-65 s e ries Derating Curve Output Derating S Input oltage 100 80 For CB with L-Bracket+cover option CB only 100 90 80 For both CB only and with L-Bracket+cover option 60 70 LOAD () 40 20 LOAD() 60 50 40-20 -10 0 10 20 30 40 50 60 (HORIZONTAL) AMBIENT TEMERATURE ( ) 90 100 110 135 155 230 264 INUT OLTAGE () 60Hz File Name:RD-65-SEC 2008-03-25
65W Dual Output Switching ower Supply RD-65 series MODEL:RD-65D OUTUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 RILE & NOISE 1:150 2:50 mp-p (Max ) mp-p (Max ) I/: 230AC O/:FULL LOAD 1: 2: 12 10 mp-p (Max ) mp-p (Max ) 2 OUTUT OLTAGE ADJUST RANGE CH1: 22.8~ 26.4 I/: 230 AC I/: 115 AC O/:MIN LOAD 21.82 21.82 ~ ~ 27.43 27.43 / 230 AC / 115 AC 3 OUTUT OLTAGE TOLERANCE 1: 2 ~ -2 (Max) 2: 5 ~ -5 (Max) I/: AC / 264 AC O/:FULL/ MIN LOAD 1: 2: 0.6 1.7 ~ ~ -0.6-1.7 4 LINE REGULATION 1: 1 ~ -1 (Max) 2: 1 ~ -1 (Max) I/: O/:FULL LOAD AC ~ 264 AC 1: 2: 0.6 0 ~ ~ -0.08 0 5 LOAD REGULATION 1: 2 ~ -2 (Max) 2: 5 ~ -5 (Max) I/: 230 AC O/:FULL ~MIN LOAD 1: 2: 0.7 0.6 ~ ~ -0.7-0.6 6 CROSS REGULATION 1: 2 ~ -2 (Max) 2: 5 ~ -5 (Max) I/: 230 AC O/: Testing O/ 60LOAD Other O/ 40LOAD Change 7 SET U TIME 230AC: 800 ms (Max) I/: 230 AC 230AC/ 196 ms O/:FULL LOAD 1: 2: 0.5 0.2 ~ ~ -1.1-0.2 8 RISE TIME 230AC: 20 ms (Max) I/: 230 AC 230AC/ 11 ms O/:FULL LOAD 9 HOLD U TIME 230AC: 20 ms (TY) I/: 230 AC 230AC/ 108 ms O/:FULL LOAD 10 OER/UNDERSHOOT TEST < +5 I/: 230 AC O/:FULL LOAD 11 DYNAMIC LOAD 1: 2400 mp-p I/: 230 AC O/:FULL /Min LOAD 90DUTY/1KHZ TEST: <5 151 mp-p Model: RD-65D Test Report 1 / 5
65W Dual Output Switching ower Supply RD-65 series INUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 INUT OLTAGE RANGE 90AC~264 AC I/:TESTING O/:FULL LOAD I/: LOW-LINE-3= 87 HIGH-LINE+15=300 O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF NO DAMAGE ) 48~264 2 INUT FREQUENCY RANGE 47HZ ~440 HZ NO DAMAGE OSC I/: 90AC ~ 264 AC O/:FULL~MIN LOAD 3 EFFICIENCY 81 (TY) I/: 230 AC 4 INUT CURRENT O/:FULL LOAD 82.4 230/ 0.9 A (TY) I/: 230 AC I = 0.7 A/ 230 AC 115/ 1.5 A (TY) I/: 115 AC I = 1.2 A/ 115 AC O/:FULL LOAD 5 INRUSH CURRENT 230/ 50 A (TY) I/: 230 AC I = 36 A/ 230 AC 115/ 25 A(TY) COLD START I/: 115 AC O/:FULL LOAD I = 18 A/ 115 AC 6 LEAKAGE CURRENT < 1 ma / 240 AC I/: 254 AC O/:Min LOAD L-FG: 0.5 ma N-FG: 0.5 ma ROTECTION FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 OER LOAD ROTECTION 90W~125W I/: 230 AC I/: 115 AC O/:TESTING 114 W/ 230 AC 112 W/ 115 AC Hiccup Mode 2 OER OLTAGE ROTECTION CH1:27.6~ 32.4 I/: 230 AC I/: 115 AC O/:MIN LOAD 30.3 / 230 AC 30.3 / 115 AC Hiccup Model 3 SHORT ROTECTION SHORT EERY OUTUT 1 HOUR NO DAMAGE I/: 264 AC O/:FULL LOAD NO DAMAGE Hiccup Mode Model: RD-65D Test Report 2 / 5
65W Dual Output Switching ower Supply RD-65 series ENIRONMENT TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 TEMERATURE RISE TEST MODEL: RD-65D 1. ROOM AMBIENT BURN-IN: 2HRS I/: 230AC O/: FULL LOAD Ta= 26.7 2. HIGH AMBIENT BURN-IN: 2HRS I/: 230AC O/: FULL LOAD Ta= 51.7 NO osition /N ROOM AMBIENT Ta= 26.7 HIGH AMBIENT Ta=51.7 1 LF1 TF-484 52.4 72.8 2 BD1 D3SB60 4A/600 SHI 60.1 77.8 3 C5 150U/400 RUB 85 US 58.2 76.8 4 R5 47K/2W R/MO 78.7 93.8 5 Q1 2SK3562 6A/600 67.4 86.5 6 C10 100U/35 RUB 105 YXF 54.6 75.0 7 D1 HER306 3A/600 72.5 91.1 8 D100 D9202 20A/200 74.3 91.8 9 C106 470U/35 RUB 105 YXG 68.8 86.4 10 T1 COIL TF-1342 68.8 84.5 11 C206 1000U/25 RUB 105 YXG 59.2 78.2 12 U1 1203 57.4 77.2 13 D200 SF10SC60 10A/60 69.5 87.8 14 RG200 78R05 3A/5 69.4 87.8 15 2 OER LOAD BURN-IN TEST NO DAMAGE 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 1.5 HOUR TURN ON TEST I/: 230 AC O/: 109W I/: 230 AC O/: 100 LOAD Ta= -10 4 HIGH HUMIDITY HIGH TEMERATURE HIGH OLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 50 I/: 272 AC O/:FULL LOAD Ta= 50 NO DAMAGE HUMIDITY= 95 R.H + 0.04 (0~50 ) I/: 230 AC O/:FULL LOAD 6 IBRATION TEST 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) + 0.01(0~50 ) Model: RD-65D Test Report 3 / 5
65W Dual Output Switching ower Supply RD-65 series SAFETY TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 WITHSTAND OLTAGE I/-O/: 3 KAC/min I/-FG: 1.5 KAC/min O/-FG: 0.5 KAC/min I/-O/: 3.6 KAC/min I/-FG: 1.8 KAC/min O/-FG: 0.6 KAC/min I/-O/: 4.92 ma I/-FG: 4.21 ma O/-FG: 3.39 ma NO DAMAGE 2 ISOLATION RESISTANCE I/-O/:500DC>100MΩ I/-FG: 500DC>100MΩ O/-FG:500DC>100MΩ I/-O/: 500 DC I/-FG: 500 DC O/-FG: 500 DC I/-O/: 5 GΩ I/-FG: 2 GΩ O/-FG: 2 GΩ NO DAMAGE 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 4 AROAL TU: Certificate NO :R50072114 UL: File NO :E183223 40 A / 2min 5 mω E.M.C TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 HARMONIC EN61000-3-2 CLASS A 2 CONDUCTION EN55022 CLASS B 3 RADIATION EN55022 CLASS B 4 E.S.D EN61000-4-2 LIGHT INDUSTRY AIR:8K / Contact:4K I/: 230 AC/50HZ O/:FULL LOAD I/: 230 AC (50HZ) O/:FULL/50 LOAD I/: 230 AC (50HZ) O/:FULL LOAD I/: 230 AC/50HZ O/:FULL LOAD ASS ASS Test by certified Lab ASS Test by certified Lab CRITERIA A 5 E.F.T EN61000-4-4 LIGHT INDUSTRY INUT: 1K I/: 230 AC/50HZ O/:FULL LOAD CRITERIA A 6 SURGE IEC61000-4-5 LIGHT INDUSTRY L-N :1K L,N-E:2K I/: 230 AC/50HZ O/:FULL LOAD CRITERIA A 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 CAACITOR SUOSE C105 IS THE MOST CRITICAL COMONENT LIFE CYCLE I/: 230AC O/:FULL LOAD Ta=25 LIFE TIME= 82703 HRS I/: 230AC O/:FULL LOAD Ta=50 LIFE TIME= 24398 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 288.1KHRS Model: RD-65D Test Report 4 / 5
65W Dual Output Switching ower Supply RD-65 series COMONENT STRESS TEST NO TEST ITEM SECICATION TEST CONDITION RESULT ERDICT 1 ower Transistor ( D to S) or (C to E) eak oltage Q1 Rated 2SK3562 : 600 6A 2 Diode eak oltage D100 Rated D9202 : 200 20 A D200 Rated SF10SC6 : 60 10 A 3 Clamp Diode eak oltage D1 Rated HER306 : 600 3A 4 Input Capacitor oltage C5 Rated : 150u/ 400/ 85 I/:High-Line +3 = 267 O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3 = 267 O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3 = 267 O/: (1)Full Load (2) Dynamic Load 90Duty/1KHz I/:High-Line +3 = 267 O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (4)Burn in 1hour (1) 478 (2) 480 (3) 548 (1) 138 (2) 150 (3) (1) (2) (3) 138 41.6 44.4 42.8 (1) 454 (2) 454 (1) 382 (2) 382 (3) (4) 382 376 5 Control IC oltage Test U1 Rated 1203 : 16 I/:High-Line +3 = 267 O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 13.1 (2) 13.1 (3) 10.8 DATE SAMLE TEST RESULT TESTER AROAL 2005/5/31 RD SAMLE ASS INCENT TSENG MAX LIN 2005/11/18 2006/3/29 RODUCT SAMLE W0510A21 RODUCT SAMLE W0603B31 ASS INCENT TSENG MAX LIN ASS INCENT TSENG MAX LIN 2003/12/12 A50-F023 Model: RD-65D Test Report 5 / 5