Electrical Workstation Nvis 7089A

Similar documents
Electrical Workstation Nvis 7089B

RAJKIYA ENGINEERING COLLEGE, KANNAUJ

VALLIAMMAI ENGINEERING COLLEGE

Electrical Machines (EE-343) For TE (ELECTRICAL)

EE 350: Electric Machinery Fundamentals

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

Dhanalakshmi Srinivasan Institute of Technology, Samayapuram, Trichy. Cycle 2 EE6512 Electrical Machines II Lab Manual

MG Electrical Machine. 68 _ ED Co.,Ltd. > EXPERIMENTS > SPECIFICATIONS

Placement Paper For Electrical

Module 1. Introduction. Version 2 EE IIT, Kharagpur

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

Electrical And Electronics Engg

BASIC ELECTRICAL LAB EQUIPMENTS

Conventional Paper-II-2013

STEADY STATE REACTANCE

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

Hours / 100 Marks Seat No.

Generator Advanced Concepts

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

SYNCHRONOUS MACHINES

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

UNIT 9 DC Separately-Excited Generator

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

Objective: Study of self-excitation characteristics of an induction machine.

ELECTRICAL POWER ENGINEERING

Code No: R Set No. 1

Code No: R Set No. 1

Inductance, capacitance and resistance

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS) Dundigal, Hyderabad

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

PART A. 1. List the types of DC Motors. Give any difference between them. BTL 1 Remembering


3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

ELECTRICAL TECHNOLOGY

1. A battery has an emf of 12.9 volts and supplies a current of 3.5 A. What is the resistance of the circuit?

1. (a) Determine the value of Resistance R and current in each branch when the total current taken by the curcuit in figure 1a is 6 Amps.

DISCUSSION OF FUNDAMENTALS

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

INVITATION FOR QUOTATION

S J P N Trust's Hirasugar Institute of Technology, Nidasoshi.

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

Conventional Paper-II-2011 Part-1A

1. Explain in detail the constructional details and working of DC motor.

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

BASIC ELECTRICAL AND ELCTRONICS ENGINEERING LABORATORY LAB MANUAL

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101)

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

LVSIM-EMS Help Table of Contents

Preface...x Chapter 1 Electrical Fundamentals

A Practical Guide to Free Energy Devices

Basic Electrical Engineering Lab Laboratory Manual

DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING 1

ENGINEERING ACADEMY X V

EE 340L EXPERIMENT # 3 SYNCHRONOUS GENERATORS

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS)

ELECTRICAL ENGINEERING LABORATORY MANUAL (NEE 151/251)

GATE 2000 Electrical Engineering

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Hours / 100 Marks Seat No.

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Impact Assessment Generator Form

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

ECET 211 Electrical Machines and Controls

Anna University of Technology Madurai. Alagar kovil road, Madurai REGULATIONS -2010

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

ELECTRICAL POWER TRANSMISSION TRAINER

ELECTRICAL MACHINE LAB. MANUAL : EM II/1

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

ELECTRIC CURRENTS AND CIRCUITS By: Richard D. Beard P.E.

2015 ELECTRICAL SCIENCE

AN ANN BASED FAULT DETECTION ON ALTERNATOR

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

Sizing Generators for Leading Power Factor

ELECTRONIC CONTROL OF A.C. MOTORS

IOCL Electrical Engineering Technical Paper

Unit FE-5 Foundation Electricity: Electrical Machines

Synchronous Machines Study Material

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

ELECTRICIAN S THEORY EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

1. SQUIRREL CAGE AC MOTOR. NO LOAD TEST

EE 340L EXPERIMENT # 5.1 SYNCHRONOUS GENERATOR (STAND-ALONE OPERATION)

Level 6 Graduate Diploma in Engineering Electro techniques

L T P EE 441: Analog Electronics (EE/IE) (3 1 3) Theory Marks =100 Sessional Marks = 50 Laboratory Marks = 50 Time = 3 hours

PAPER-II (Subjective)

FINAL - ET 60 - Electrician Theory Examination Marking Schedule

GATE SOLVED PAPER - EE

MEHRAN UNIVERSITY OF ENGINEERING & TECHNOLOGY, JAMSHORO

Exercise 3. Doubly-Fed Induction Generators EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Doubly-fed induction generator operation

Manuals. Basic Electrical Engineering BE-104

Industrial Electrician Level 3

TYPICAL QUESTIONS & ANSWERS

Three-Phase Induction Motors. By Sintayehu Challa ECEg332:-Electrical Machine I

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ACADEMIC YEAR / EVEN SEMESTER QUESTION BANK

Lesson Plan. Name of the Faculty : Discipline : Electrical Engineering Semester : 4 th Semester. Lesson Plan Duration : Week

ELECTRIC DRIVE LAB Laboratory Manual

Transcription:

All AC & DC Machines are optional Electrical Workstation offers an excellent approach to the teaching of Electrical Machines principles by introducing a unique modular designed control unit. It provides flexibility for the students to carry out experiments over AC and DC Machines using a large selection of Industry standard inbuilt components. Electrical Machines is one of the most important area of study as it helps users to understand the operational characteristics and working of AC and DC Machines. enables user to put their theory knowledge into practice with ease. There is an additional facility to make wireless connection on workstation with computer and to monitor real time electrical parameters using computer interfacing software. Users can also observe a real time graph between any of the AC and DC electrical parameters on computer. Workstation comprises of separate AC and DC measuring sections equipped with all the necessary instruments such as digital meters, facility to connect AC and DC Supplies along with protection devices such as Fuses, MCB s, Supply Indicators, etc. There are multiple buses provided on the Workstation to make external connections while performing AC and DC Machines Experiments. The design of the control unit ensures to get the highest quality practical experience to user. All the necessary protective measures are taken to avoid fault or danger. Note: All AC & DC Machines along with supporting accessories are available optionally

Features Compatible for Machines upto 2HP Equipped with Measurement Facilities for Experimentation on AC Machines, DC Machines and Transformers Separate AC and DC Measuring Sections Diagrammatic representation of AC and DC Machines for better understanding Rust Free Powder Coating Paint Standard BS-10 terminals, patch cords for safety purpose Terminals provided to obtain Three Phase Fixed as well as Variable AC and DC Supplies with suitable protection High Quality Digital Tachometer for RPM Measurement which is also interfaced with DAQ (Data Acquisition System) s provided with standard Mechanical Loading Arrangement Facility s with aluminum casted Brake-Drum/Pulley with heat suppression facility Machines with Class B Flexible shaft coupling arrangement (Lovejoy) for Generator (MG) Sets Machines provided with Heavy Duty Base/Channel with suitable interconnection Machines provided with suitable protections such as MCB's, Fuses, Generator (MG) Sets provided with coupling protective cover Generator with Electrical Loading Arrangement Facility Durable good quality spring balance Designed by considering all the safety measures Note: All AC & DC Machines along with supporting accessories are available optionally Technical Specifications Electrical Measuring Instruments AC Ammeter (4 Nos.) : Digital Range : 10A AC Voltmeter (4 Nos.) : Digital Range : 450Vrms DC Ammeter (4 Nos.) : Digital Range : 20A DC Voltmeter (4 Nos.) : Digital Range : 300V Single Phase Wattmeter (2 Nos.) : Digital Range : 4kW DC Supply Voltage : 300V ± 10% Current : 2Amp Protective Devices Three Phase MCB (TPN) : 2 Nos. Interconnections : 4mm BS-10 Safety Terminals with Mechanical loading arrangement Generator with Electrical loading arrangement

Experiments with DC Machines (optional) DC Shunt Wound Study of Operational Working and Principle of DC Shunt Study of running and reversing phenomenon of DC Shunt Study of No Load Characteristic of DC Shunt Study of Load Characteristic of DC Shunt Study of speed control of DC Shunt using armature voltage control and flux field control method Study and Determine the losses of DC Machine and correspondingly calculate the efficiency of DC Machine by Swinburn's Test Method DC Series Wound Study of Operational Working and Principle of DC Series Study of running and reversing phenomenon of DC Series Study of Load Characteristic of DC Series Study of speed control of DC Series using armature voltage control and flux field control methods DC Compound Wound DC Series Wound Generator Study of Operational Working and Principle of DC Series Wound Generator Study and measurement of Open Circuit Characteristic of DC Series Generator Study and measurement of Load Characteristic of DC Series Generator Study and verify the Field Test of DC Series Machine and correspondingly determine the efficiency of DC Series and Generator at any desire load DC Compound Wound Generator Study of Operational Working and Principle of DC Compound Wound Generator Study and verify the Load Characteristics of Long Shunt Cumulatively Compound Generator Study and verify the Load Characteristics of Short Shunt Cumulatively Compound Generator Study and verify the Load Characteristics of Long Shunt Differentially Compound Generator Study and verify the Load Characteristics of Short Shunt Differentially Compound Generator Study of Operational Working and Principle of DC Compound Study of running and reversing phenomenon of DC Compound Study of Load Characteristic of DC Cumulative-Compound Wound Study of Load Characteristic of DC Differential-Compound Wound DC Shunt Wound Generator Study of Operational Working and Principle of DC Shunt Generator Study and measurement of Open Circuit Characteristic of DC Shunt Generator N A M Curr ent Field Motion B B Rotation of coil anticlockwise S C Curr ent Field Study and measurement of External Characteristic of DC Shunt Generator Study and measurement of Internal Characteristic of DC Shunt Generator Shaft Commutator Carbon brush G - + Galvanometer Working Principle of DC Generator

AC Machines (optional) Single Phase Capacitor Start Induction Study of Operational Working and Principle of Single Phase Induction Study of Running and Reversing of Single Phase Induction Study of the No-Load Test in a Single Phase Induction Study of the Blocked Rotor Test in a Single Phase Induction Study of Load Test in a Single Phase Induction Three-phase Squirrel Cage Induction Study of Operational Working and Principle of Three Phase Squirrel Cage Induction Study of Running and Reversing of Three Phase Induction Study of No Load Test performed in a Three Phase Induction Study of Block Rotor Test performed in a Three Phase Induction Measurement of Slip in a Three Phase Induction Study of Speed-Torque characteristics in a Three Phase Induction Three Phase Salient Pole Synchronous Study of Operational Working and Principle of Three Phase Synchronous Study of V curve of Three Phase Synchronous Study of Inverse V curve of the Three Phase Synchronous Three Phase Salient Pole Synchronous Generator Study of Operational Working Principle of Three Phase Synchronous Generator Study and Measurement of Direct Axis (Xd) Reactance by Slip Test Study and Measurement of Quadrature Axis (Xq) Reactance by Slip Test Study and Measurement of Positive Sequence Impedance of Three Phase Synchronous Generator Study and Measurement of Negative Sequence Impedance of Three Phase Synchronous Generator Study and Measurement of Zero Sequence Impedance of Three Phase Synchronous Generator Study of short circuit characteristics (SCC) of three Phase Synchronous Generator Study of open circuit characteristics (OCC) of three Phase Synchronous Generator Study and measure of voltage regulation of Three Phase Synchronous Generator using EMF Method Single Phase Transformer: Study of Single-Phase Isolation Transformer Study of Single-Phase Step Up Transformer Study of Single-Phase Step Down Transformer Study of Subtractive Polarity of Single Phase Transformer Study of Additive Polarity of Single-Phase Transformer Study of Open Circuit test of Single-Phase Transformer Study of Short Circuit Test of Single-Phase Transformer To determine the Efficiency and Voltage Regulation of a Single-Phase Transformer by direct loading at different loading condition. Three Phase Transformer: Study of Open Circuit test of Three-Phase Transformer Study of Short Circuit Test of Three-Phase Transformer Study of Three Phase Configurations in Three Phase Transformer **More than 70 Experiments can be performed in Nvis 7089A **Also suitable for performing experiments on basic Electrical Measurements Magnet Brush N Slip-Rings Working Principle of AC Generator S

Technical Specifications of Optional Machines DC s (optional) : Nvis SHM05, Nvis SHM10 & Nvis SHM20 : Shunt : Available with 1/2HP, 1HP& 2HP Loading arrangement : Mechanical Spring Balance : 2Nos.(Tubular ) Brake Drum/Pulley : Aluminum casted with heat suppression facility Machine Base : C Channel DC s with standard Mechanical loading arrangement Protection : Fuses (mounted at the terminal box of the Machines) : Nvis SM10 & Nvis SM20 : Series : Available with 1HP&2HP Loading arrangement : Mechanical Spring Balance : 2Nos. (Tubular ) Brake Drum/Pulley : Aluminum casted with heat suppression facility Machine Base : C Channel Protection : Fuses (mounted at the terminal box of the Machines) : Nvis CM10 & Nvis CM20 : Compound : Available with 1HP & 2HP : Class 'B' Loading arrangement: Mechanical Spring Balance Brake Drum/Pulley Machine Base Protection : 2Nos.(Tubular ) : Aluminum casted with heat suppression facility : C Channel : Fuses (mounted at the terminal box of the Machines) Selection Guide Machine Ratings Shunt Series Compound 0.5 HP 1 HP 2 HP Nvis SHM05 -- -- Nvis SHM10 Nvis SM10 Nvis CM10 Nvis SHM20 Nvis SM20 Nvis CM20

AC s (optional) : Nvis SPM10 : Single phase Capacitor Start Induction : Available with 1HP Voltage Rating : 230V AC ± 5%, 50Hz Rated Speed : 1440RPM ± 7.5% Loading arrangement : Mechanical Spring Balance : 2 Nos. (Tubular ) Brake Drum/Pulley : Aluminum casted with heat suppression facility Machine Base : C Channel Protection : Fuses (mounted at the terminal box of the Machines) : Nvis SQM10 & Nvis SQM20 : Three Phase Squirrel Cage Induction : Available with 1HP & 2HP Voltage Rating : 415V AC ± 5%, 50Hz Rated Speed : 1440RPM ± 7.5% Loading arrangement : Mechanical Spring Balance : 2 Nos. (Tubular ) Brake Drum/Pulley : Aluminum casted with heat suppression Facility Machine Base : C Channel Protection : Fuses (mounted at the terminal box of the Machines) AC s with standard Mechanical loading arrangement Single Phase Transformer (optional) Transformer Specifications Mains Supply Rating Three Phase Transformer (optional) Transformer modules : Single Phase, 230V AC ±10%, 50Hz : 1kVA Primary Voltage : 0-125V, 0-125V Secondary Voltage : 0-125V, 0-125V Rated Current : 5A Transformer Specifications Mains Supply Primary Voltage Secondary Voltage : 415V ±10%, 50Hz : Three Phase : 1kVA : 415V : 230V Rated Current : 4A Selection Guide Machine Ratings Selection Guide Single Phase Capacitor Start Induction Three Phase Squirrel Cage Induction 1 HP Nvis SPM10 Nvis SQM10 2 HP ----- Nvis SQM20 Transformer Ratings Single Phase Transformer Three Phase Transformer 1 KVA Nvis SPT10 Nvis TPT10

DC Generators (optional) : Nvis SHG05,Nvis SHG10 & Nvis SHG20 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine (acts as prime mover) : Shunt DC Machine (acts as generator) : Shunt : Available with 0.5HP, 1HP & 2HP Shaft extension : Single Sided Loading Arrangement : Electrical of Coupling Machine Base Protection : Flexible Lovejoy Coupling : C Channel : Fuses (mounted at the terminal box of the Machines) : Nvis SG10 & Nvis SG20 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine (acts as prime mover) : Shunt DC Machine (acts as generator) : Series : Available with 1HP & 2HP Shaft extension : Single Sided Loading Arrangement : Electrical of Coupling Machine Base Protection : Flexible Lovejoy Coupling : C Channel : Fuses(mounted at the terminal box of the Machines) DC s -Generator Set Coupled with Flexible Lovejoy Coupling Lovejoy Coupling : Nvis CG10 & Nvis CG20 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine (acts as prime mover) : Compound DC Machine (acts as generator) : Compound : Available with 1HP & 2HP Shaft extension : Single Sided Loading Arrangement : Electrical of Coupling Machine Base Protection : Flexible Lovejoy Coupling : C Channel : Fuses (mounted at the terminal box of the Machines) Selection Guide Machine Ratings Shunt Generator Series Generator Compound Generator 0.5 HP Nvis SHG05 -- -- 1 HP Nvis SHG10 Nvis SG10 Nvis CG10 2 HP Nvis SHG20 Nvis SG20 Nvis CG20

AC Generators (optional) Protective Coupler Cover : Nvis TPM30 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base Three Phase Synchronous Machine : Salient : 3 HP AC s -Generator Set Coupled with Flexible Lovejoy Coupling Voltage Rating : 415V AC ± 10%, 50Hz Configuration : Delta Connected Rated Speed : 1500RPM ± 5% Excitation Voltage : 180Vdc ± 10% DC Machine (acts as generator) : Shunt : 2HP : Nvis TP30 Both the Machines are flexibly coupled and Mounted on a Single 'C' Channel Base DC Machine : Shunt : 2HP Rated Speed : 1500RPM ± 5% Three Phase Synchronous Machine Loading Arrangement : Electrical of Coupling Machine Base Protection : Flexible Lovejoy Coupling : C Channel : Fuses (mounted at the terminal box of the Machines) : Salient Configuration : "Star" Connected : 3HP Voltage Rating : 415V AC ± 5%, 50Hz Excitation Voltage : 180Vdc ± 10% Loading Arrangement : Electrical Selection Guide of Coupling Machine Base Protection : Flexible Lovejoy Coupling : C Channel : Fuses (mounted at the terminal box of the Machines) Machine Ratings 3 HP Three Phase Synchronous Nvis TPM30 Three Phase Synchronous Machine Nvis TP30 ** We also offer customized Solutions for different and -Generator Set.

Other Supporting Optional Items Single and Three Phase Resistive Load Single Phase Operation Voltage : 240V AC ±10%, 50Hz Current : 15A Power : 3.5kW Loading steps : 15 Three Phase Star Operation Voltage : 415V AC ±10%, 50Hz Current : 5A (per Phase) Power : 3.5kW Loading steps : 5 (per Phase) Three Phase Delta Operation Voltage : 415V AC ±10%, 50Hz Current : 15A (per Phase) Power : 10.5kW Loading steps : 5 (per Phase) Switching Technique : Star/Delta Switch, 415V, 25A Mains MCB : 16A (TPN) Single and Three Phase Inductive Load Single Phase Operation Voltage : 230V AC ±10%, 50Hz Current : 15A Power : 4 KVAR Three Phase Star Operation Voltage : 415V AC ±10%, 50Hz Current : 5.5A (per Phase) Power : 4KVAR Three Phase Delta Operation Voltage : 415V AC ±10%, 50Hz Current : 15A (per Phase) Power : 10KVAR Star/Delta Switch : 415V, 25A MCB : 16A Single and Three Phase Capacitive Load Single Phase Operation Voltage : 230V AC ±10%, 50Hz Current : 14A (Approx.) Loading steps : 30 Three Phase Star Operation Voltage : 415V AC ±10%, 50Hz Current : 4.6A (per Phase) Loading steps : 10 (per Phase) Three Phase Delta Operation Voltage : 415V AC ±10%, 50Hz Current : 13A (per Phase) Loading steps : 10 (per Phase) Switching Technique : Star/Delta Switch, 415V, 25A Mains MCB : 16A (TPN) 10A (One Pole) 30 Nos. Single and Three Phase Resistive Load Single and Three Phase Inductive Load Single and Three Phase Capacitive Load

Thyristorized DC Regulated Power Supply Input Mains : 415VAC ± 10%, 50Hz Rated Output Voltage : 220VDC (Fixed) ± 5%, Rated Output Current : 50ADC Regulation : Less than 3% at full load condition. Measuring Instruments AC Voltmeter : 1 No. (with voltage selector switch) DC Ammeter : 1 No. DC Voltmeter : 1 No. Protection with its indicators Overload Protection Short Circuit Protection Phase Sequence Indicator Single Phase Variac : Close Thyristorized DC Regulated Power Supply Operating Rating : 230V AC ±10%, 50Hz Output Voltage : 0-270V AC ±10%, 50Hz Current : 10A (Also available in different Current Ratings) Three Phase Variac : Close Operating Rating : 415V AC ±10%, 50Hz Output Voltage : 0-470V AC ±10%, 50Hz Current : 10A (Also available in different Current Ratings) Rheostats AC Starters DC Starters Three Phase Variac Single Phase Variac DC Starters AC Starters Rheostats

Nvis Electrical Data Acquisition System (optional) is a versatile solution that allows high quality measurements for all Electrical Parameters and is suited for all types of Engineering Laboratories. Electrical Data Acquisition System provides wireless measurements of Single and Three Phase AC as well as DC Parameters measurements with high accuracy. Nvis Electrical Data Acquisition System includes three inputs each for Voltage and Current, two inputs each for DC Voltage and DC Current to measure an entire Three Phase Parameters and DC Parameters such as AC and DC Voltage, AC and DC Current, Active Power, Reactive Power, Apparent Power, Power Factor, Frequency, etc. along with Over Load Protection Indicators and buzzer at the same time. All these parameters will be displayed on the PC Software screen provided with the product. Nvis Electrical Data Acquisition System is compatible for three phase/three wire and three phase/four wire configurations. User can also plot a real time graph between any of these parameters on computer through the facility of wireless connectivity. Features Electrical Data Acquisition System is compatible for Machine upto 1HP Real Time monitoring of electrical parameters using computer Interface Software Curve can be plotted between any of the two electrical parameters along with its calculation done on computer Facility to store plotting curve reading for further reference Microcontroller based accurate and reliable design Singe Phase Parameters Measurement - 3 AC Voltage Inputs - 3 AC Current Inputs Corresponding Active Power, Reactive Power, Apparent Power, Frequency, Power Factor and Angle - 2 DC voltage Inputs - 2 DC current Inputs Three Phase Parameters Measurement - Line to Neutral Voltage - Line to Line Voltage - Line Current - Active Power - Reactive Power - Apparent Power - Frequency - Power Factor CT is used as Current Transducer Fully isolated measurement Real Time monitoring of electrical parameters using computer interface software

Technical Specifications Communication Frequency : 2.4GHz RF Power Range : 1mWatt : 10Mtr. Measurement Ranges AC Voltage Range : 25-450Vrms, accuracy ±1% AC Current Range : 0.20-10Amp, accuracy ±1% DC Voltage Range : 25-300Vrms, accuracy ±1% DC Current Range : 0.20-10Amp, accuracy ±1% Frequency : 45-55Hz, accuracy ±0.5Hz Torque Measurement Unit (Optional) Active Power : 50-3000Watts, accuracy ±2% Reactive Power : 50-3000Watts, accuracy ±2% Apparent Power : 50-3000Watts, accuracy ±2% Power Factor Speed Torque Auxiliary Supply : 0.30 to 0.99 both Lead and Lag, accuracy ±3º Electrical : Up to 2500 RPM : 0-25 N-m : 230V AC± 10%, 50Hz Wireless connectivity with computer (Optional) Speed Measurement Device (Optional) Nvis Technologies Pvt. Ltd. 141-A, Electronic Complex, Pardesipura, Indore-452010, India. +91-731-4211500, info@nvistech.com, www.nvistech.com