Government of Assam OFFICE OF THE PRINCIPAL :: ASSAM MEDICAL COLLEGE DIBRUGARH 786002 (ASSAM) Phone : 0373-2300080(O), Fax: 0373-2300080(O) No. 2015/AMC/13149 Dated,, the 1 st October/2015 NOTICE INVITING TENDER Sealed Tenders are invited in two Bid System (Technical and Commercial bid) for SITC for supply and installation of Sound system for the Auditorium of Assam Medical College,. For details please log on to the website of the Assam Medical College, www.assammedicalcollege.in Principal Assam Medical College Memo No. 2015/AMC/131500 Dated the 1 st Oct, 2015 Copy to: The Director of Information and Public Relation, Assam, Dispur, Guwahati-6 with a request to publish the above advertisement in two widely circulated Newspaper (Dainik Janambhumi & The Assam Tribune). Principal Assam Medical College
GOVERNMENT OF ASSAM OFFICE OF THE PRI INCIPAL:: ASSAM MEDICA AL COLLEGE DIBRUGARH 786 002 Phone : 2300080 (O), Fax : 2300080 (O) No. 2015/AMC/13151 Date: 01-10-2015 TENDER NOTICE Sealed tenders affixing court fee stamp of Rs. 8.25 (Rupees Eight and Paise Twenty Five) only are invited only from the Govt. Registered authorized stockiest/dealer/suppliers for supply of Machinery Equipments/ Instruments to the Assam Medical College & Hospital, will be received by the undersigned upto 1:00 PM (I.S.T) of 07-10-2015 and the Tenders will be opened on the same day at 3:00 PM in presence of the Tenderers or their authorized representative at the Office of the Principal, AMC&H,. The tender must be accompanied by Earnest Money amounting to Rs. 30,000.00 (Rupees Thirty Thousand) only in the Form of National Saving Certificate/Kishan Vikas Patra duly pledged to The Principal-cumof document as Chief Superintendent, Assam Medical College & Hospital,. The tender will be rejected if found incomplete or absence required as per detailed tender paper. Detailed tender paper with terms and conditions may be obtained from the Office of the Principal, Assam Medical College, on any working day during 10:30 AM to 4:00 PM. Principal-Cum-Chief Superintendent Assam Medical College & Hospital
GOVERNMENT OF ASSAM OFFICE OF THE PRI INCIPAL :: ASSAM MEDICA AL COLLEGE DIBRUGARH 786 002 Phone : 2300080 (O), Fax : 2300080 (O) No. 2015/AMC/13151 Date: 01-10-2015 TERMS AND CONDITIONN of Tender Notice for supply of Machinery Equipment/ Instruments TO THE ASSAM MEDICAL COLLEGE & HOSPITAL, DIBRUGARH. 1. The rate of each item should be shown against each item separately inclusive of cost of deliver to the site of the customer but exclusive of VAT in case of taxable items which should be shown separately in the bill. 2. The Govt. registration number should be clearly indicated in the tender. Tenderers are also required to show financial position supported by Bank or Postal deposit statement. 3. An upto date copy of VAT and Income Tax clearance should be furnished alongwith the quotation. Permanent Income Tax registration TAN/PAN numbers and VAT Registration TIN number should also be mentioned in the tender paper. 4. While quoting the prices of each item the Tenderers are advised to quote the rate of each item with full specification as sought for in the tender paper and keep in mind the prevailing market prices of different items. 5. Selected Tenderers will have to deposit security money @ 2% of total estimated supplies of Machinery Equipment/ Instruments subject to minimum Rs. 10,000/- (Rupees Ten Thousand) only in the form of National Saving Certificate/Kishan Vikas Patra duly pledged to the Principal-Cum-Chief Superintendent, Assam Medical College & Hospital,. 6. After finalization of the contract for supply of Machinery Equipment/ Instruments the successful Tenderers will have to execute necessary contract deed of agreement and should be duly registered along with above security deposit. The earnest money will be refundable. The undersigned reserve the right to reject/cancel the assigning any reason thereof. tender without Enclo:- List. Principal-Cum-Chief Superintendent Assam Medical College & Hospital
The size of the Auditorium- Length-113ft Width- 74ft and Height-20ft. Windows-6 and Door-7. Sound system:- Supply Installation Commissioning & testing. Supply, installation, testing and commissioning of Main FOH Left Cluster Active Line Array module loudspeaker having frequency Response (+/-3 db) : 76 Hz to 16kHz or better, Nominal dispersion 100H X 45 V or ; (Total of 60 degree vertical dispersion is required for uniform coverage. All OEMs shall quote appropriate number of boxes as per vertical dispersion of each box being proposed) ; Maximum SPL : 131 db SPL or better ; Long-Term Power Handling is LF/MF: 500 Watt or better HF: 180 Watt or better, Transducer : HF: 1 X 2" or 2 X 1" or better LF: 2 X 8" or better Cabinet Moulded on a special Propylene Composite Material complete with standard accessories. Supply, installation, testing and commissioning of Main FOH Right Cluster Active Line Array module loudspeaker having frequency Response (+/-3 db) : 76 Hz to 16kHz or better, Nominal dispersion 100H X 45 V or ; (Total of 60 degree vertical dispersion is required for uniform coverage. All OEMs shall quote appropriate number of boxes as per vertical dispersion of each box being proposed) ; Maximum SPL : 131 db SPL or better ; Long-Term Power Handling is LF/MF: 500 Watt or better HF: 180 Watt or better, Transducer : HF: 1 X 2" or 2 X 1" or better LF: 2 X 8" or better Cabinet Moulded on a special Propylene Composite Material complete with standard accessories as per tender specifications Supply, Installation testing and commissioning of Mounting/Hanging arrangement for flying above Line array. Supply, installation, testing and commissioning of Active Subwoofer module with frequency response of 32Hz to 110 Hz or better, Long term power handling of 1200 Watt or better, Max SPL of 133 Db SPL or better,transducer : 2 X 15" or better ; Cabinet Moulded on a special Propylene Composite Material. Supply, installation, testing and commissioning of Stage monitors with frequency response of 60 Hz to 16kHz or better; nominal dispersion angle of 50 H X 50 V or better; Max SPL : 129 db SPL or better ; power handling of 700 Watt or better @ 8 Ohm, Transducers Size : HF: 1 X 1 " or better ; LF: 1 x 10"; Cabinet Moulded on a special Propylene Composite Material. Supply, installation, testing and commissioning of Control Room Monitoring speakers with frequency response of 160 Hz to 14kHz or better ; nominal dispersion angle of 80 H X 80 V or better ; Max SPL : 113 db SPL or better ; power handling of 100 Watt or better @ 8 Ohm, Transducers Size : HF: 1 X 0.75 " or better ; LF: 1 x 4" OR : 1 X 4 " better ; Cabinet Moulded on a special Propylene Composite Material.
Supply, Installation testing and commissioning of Mounting/hanging arrangement for flying above subwoofers Supply, installation, testing and commissioning of Power Amplifier or equivalent with Number of Min Channel : 2 Channels or better ; Frequency Response : 20Hz - 20kHz ; Continuous Power per channel : (impedance):450 W @ 4Ohm or better ; 250W @ 8Ohm or better ; THD < 0.5% or better ; Damping Factor > 200 W ; S/N Ration : > 100 db or better complete with standard accessories. Supply, installation, testing and commissioning of Digital Signal Processor with Min Inputs : 2 ; Min Outputs : 4 or better ; Sampling Rate : 48 khz or better ; A/D and D/A Convertor : 24 bit or better ; Dynamic Range : > 105 db or better ; With Routers, Equalizers, Band Pass Filter, Delay, Limiter, Gain, etc. ; with complete equalization. Supply, Installation, testing and commissioning of Mixer with 16 Mic inputs or better, 4 Stereo Inputs or better ; Eqs : 3 or better ; Aux : 3 or better ; Fader ; Effects ; with internal power supply complete with standard accessories. Supply, Installation, testing and commissioning of UHF wireless handheld microphone - diversity system with Polar Pattern : Cardioid/Hypercardioid/Supercardioid ; Audio Bandwidth : 80 Hz - 15 khz or better, RF Freq Range : 558 MHz to 606 Mhz or better ; Signal/noise ratio > 105 db or better ; THD : < 0.9% or better front panel LCD display, Mute function complete with standard accessories Supply, Installation, testing and commissioning of UHF wireless Lapel/Lavellier/Collar microphone - diversity system with Polar Pattern : Cardioid/Hypercardioid/Supercardioid, RF Freq Range : 516 MHz to 865 Mhz or better ; Signal/noise ratio > 105 db or better ; THD : < 0.9% ; RF Power : 20mW ; or better front panel LCD display, Mute function complete with standard accessories Wired Handheld Dynamic microphone with freq Response : 55 Hz to 15 KHz ; supercardiod / Cardiod/Hypercardioid ; ON/OFF Switch with Lock ; Sensitivity : 2.7mV ; Minimum Handling Noise with standard accessories. Supply, Installation, testing and commissioning Instrumental microphone with freq Response : 50 Hz to 16 KHz or better ; supercardiod / Cardiod/Hypercardioid polar pattern ; Output Impedance : < 350 Ohm or better complete with standard accessories Supply, Installation, testing and commissioning of 15" Gooseneck microphone with cardioid/supercardiod polar pattern with flexible gooseneck, Frequency Response of 50 Hz to 17 khz or better ; S/N Ratio : 65 db or better ; Max SPL : 107 Db spl or better ; LED Indication & RF Sheilding complete with standard accessories Supply of CD Cum USB Player complete with standard accessories Supply and laying of 2 core 2.5 sq mm PVC insulated Cu conduction loudspeaker cable Supply and laying of 2 core PVC insulated Cu conduction sheilded microphone cable Supply of Microphone Stands (Long) Supply of Microphone Stands (Short
Supply and fixing of 5 point mic junction boxes Supply of UL Listed Connectors Supply of Equipment Rack for housing all rack mountable equipments with internal wiring, front glass door; heat dessipation fans; internal lights; movement wheels, power distribution units etc. Principal-cum-Chief Superintendent, Assam Medical College & Hospital,