E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

Similar documents
Sentry Digital Timers

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

1. Contents Page. 2. Assembly, putting into operation, connection Control elements Display Factory setting Changing settings 6

OPERATING INSTRUCTIONS Digital weekly time switch

16-Channel Yearly Time Switch TR 648 S DCF

DIN Rail Time & Twilight Switches

Wireless temperature controller E N RFTC-50/G

SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

Tempus Digital Digital Astro-Timer D GB CZ BZT28A71. Installation and Operating Manual BZT28A71

Instruction manual. art Installation manual

Contents. Time switches. Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S.

ISOMETER IRDH575. Approvals

IMPULSE SWITCH, REMOTE SWITCH

Selection tables Command devices E 250 latching relays

24HR/7 DAY YEARLY 4 CHANNEL INSTALLATION & OPERATING (4 MODULE) 16A. DIGITAL TIMESWITCH Cat. No TR644S INSTRUCTIONS

LK Wireless Room Control Cq

Modular step relays 16 A

User Instructions For TopTronic RS-10

Radio-control universal dimmer (built-in type) Installation Instructions

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

12 Series - Time switches 16 A. Features

PIR6WT-1Z interface - time relays

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

EIB/KNX Switch Actuators. User manual

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

PLA 33. Power line analyzer. User and service manual. version 2.4

Power-meters three-phase

RCMS460 and RCMS490 Series

Moeller Electric Corporation

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Modular Devices - Indicators and Push Buttons

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

Alarm-Display SD 9648

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

Multi-voltage Multi-function. Wiring diagram (without control signal)

Operating Instruction

SUNDIAL Light Dimmer. User's Manual

Pulse Scaler for DIN Rail Attachment

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Wireless multizone receiver RDE-MZ6

Protection and safety SQZ3 phase and sequence relay

WLDS-10 Mk3 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Time switches 16 A NEON SЕRIES. Heating and cooling. Shop displays. Lighting for parks. Streetlights and car park lighting.

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Monitoring Relay MR 50

Three-phase monitoring relays CM-PFE and CM-PFE.2

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

Electronic relays. Monitoring. Monitoring

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Liquid level monitoring relay CM-ENS.2x

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

INSTAT 868 Radio Frequency Single-Room Controls

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Mounting Instructions / Manual MV1171

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Monitoring relays. HRN-55N supply L1-N (monitors also disconnection of neutral wire) Time delay to eliminate peaks.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

PROGRAMMABLE DIGITAL TIMER ELIRO (33 Functions): V7DFTS3

Three-phase monitoring relay

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Operating Manual MU2000K

Electronic timer CT-MFS.21

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

WLDS-10 Mk2 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

REV-201М OPERATING MANUAL MULTIFUNCTIONAL TWO-CHANNEL TIME DELAY RELAY. «NOVATEK-ELECTRO» Ltd Intelligent industrial electronics

PART NUMBERING SYSTEM

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Self-learning Room Temperature Controller Receiver

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Transcription:

Digital time switch E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

Content Symbol, Connection... 3 Warning... Characteristics... 5 Technical parameters... 6 Versions of time switches, Load... 7 Description... 8-9 Control... 10 Mode precendence, ual output control... 11 ram... 12 ram adjustment... 13 ram deleting, Deleting of all programs... 1 Date and time... 15 Setting of programmed/random mode... 16 Setting of pulse/cyclic mode interval... 17 Holiday mode... 18 Exit from menu, Reset... 19 Example of programming... 20-2 -

Symbol SHT-1 SHT-3 A1 16 18 SHT-1/2 SHT-3/2 A1 16 18 26 28 A2 15 A2 15 25 E N Connection SHT-1 SHT-3 A1 16 15 18 SHT-1/2 SHT-3/2 A1 16 15 18 Un Un A2 A2 26 25 28-3 -

Warning Device is constructed for connection in 1-phase main alternating current voltage and must be installed according to norms valid in the state of application. Connection according to the details in this direction. Installation, connection, and servicing should be installed by qualified electrician staff only, who has learnt these instruction and functions of the device. This device contains protection against overvoltage peaks and disturbancies in supply. For correct function of the protection of this device there must be suitable protections of higher degree (A,B,C) installed in front of them. According to standards elimination of disturbancies must be ensured. Before installation the main switch must be in position OFF and the device should be de-energized. Don t install the device to sources of excessive electro-magnetic interference. By correct installation ensure ideal air circulation so in case of permanent operation and higher ambient temperature the maximal operating temperature of the device is not - - exceeded. For installation and use screw-driver cca 2 mm. The device is fully-electronic - installation should be carried out according to this fact. Non-problematic function depends also on the way of transportation, storing and handling. In case of any signs of destruction, deformation, non-function or missing part, don t install and claim at your seller it is possible to dismount the device after its lifetime, recycle, or store in protective dump.

Characteristics - Serves for controlling of various types of appliances in dependance on real time (automation-switching of heating, pumps, ventilation etc.). Appliances can be operated in concrete periodic time cycles or according a pre-set program (depends on type, see the chart Versions of time switches). - SHT-1, SHT-3: 1-channel version. - SHT-1/2, SHT-3/2: 2-channel version (to each channel can be assigned an individual program). - Possibility to control two independent circuits. - By SHT-3, SHT-3/2 is not possible to integrate daily and night mode on one channel. By SHT-3/2 is possible to set a different mode on each channel. - Setting of switching by: - program (PROG) - switching according programs set in SET 1. Possibility to set the repeat every minute or every hour. - random (AUTO ) - random switching in 10-120 min interval. - permanently manualy. - Switching modes (OUT): - OUT ON - normal - 2 positions in memory (close / open), shortest time of closing is 1 min. - OUT ON - cyclic - 2 positions in memory (pulse/delay), range 1-99s. - 5 - - OUT ON - pulse - 1 position in memory, range 1-99s. - OUT OFF - turn off the switching mode. - Set time of pulse/delay is on one channel the same for all programs (it is not possible to set more pulses with different durations on one channel). - Holiday mode - - possibility to choose the period, when the device will be not switching according a standard program and will be blocked for the pre-set time. - 100 memory positions (by SHT-1/2 and SHT-3/2 are those 100 positions common for both channels). - ramming of device can be realize even under voltage and also even in back-up mode. - Output relays operates only under voltage. - Automatic change-over between summer/winter time ( is for time zone GTM+1:00). - Back-lighted LCD display. - Easy and quick by control buttons. - Sealable transparent cover of the front panel. - Time switch is back-up with in-built lithium element, which saves data during voltage failure. Back-up time reserve - up to 3 years. - Supply voltage: AC 230V or AC/DC 12-0V. - 2-Module, DIN rail mounting, saddle terminals. - Device is delivered with pre-programmed actual time, which is permanently displayed also in back-up mode. E N

Technical parameters Supply terminals: A1 - A2 Supply voltage: AC/DC 12-0V (AC 50-60Hz) Consumption: AC 0.5-2VA / DC 0. - 2W Supply voltage: AC 230V / 50-60Hz Consumption: AC max. 1VA / 2W Supply voltage tolerance: -15 %; +10 % Real time back-up: yes Summer/winter time: automatic Output: Number of contacts: - SHT-1, SHT-3: 1 x changeover (AgSnO 2 ) - SHT-1/2, SHT-3/2: 2 x changeover (AgSnO 2 ) Rated current: 16A / AC1 Switching capacity: 000 VA / AC1, 38W / DC Peak current: 30A / <3s Switching voltage: 250V AC1 / V DC Min. switching capacity DC: 500 mw Mechanical life: > 3x10 7 Electrical life (AC1): > 0.7x10 5 Time circuit Real time back-up when de-energi.: up to 3 years Accuracy: max. ±1s/ day at 23 C Minimum interval: 1 min. Data stored for: min. 10 years Cyclic output: 1-99s Pulse output: 1-99s 230 UNI ram circuit Number of memory places: ram (SHT-1; SHT-1/2): ram(sht-3, SHT-3/2): Data readout: Other information Operating temperature: Storage temperature: Electrical strength: Operating position: Mounting: Protection degree: Overvoltage category: Pollution degree: Max. cable size (mm 2 ): Dimensions: Weight - SHT-1, SHT-3: - SHT-1/2, SHT-3/2: Standards: - 6-100 daily, weekly daily, weekly, monthly, yearly (up to year 2095) LCD display, with back light -20.. +55 C -30.. +70 C kv (supply - output) any DIN rail EN 60715 IP10 clips, IP0 from front panel III. 2 solid wire max. 2x2.5 or 1x with sleeve max. 1x2.5 or 2x1.5 90 x 35.6 x 6 mm (UNI)-130 g, (230)-110 g (UNI)-13 g, (230)-125 g EN 61812-1, EN 61010-1

Versions of time switches output time program Type of product 1 channel 2 channels day week month year SHT-1 Load SHT-1/2 SHT-3 SHT-3/2 E N Type of load Contact material AgSnO 2, Contact 16A cos φ 0.95 M M AC1 AC2 AC3 250V / 16A 250V / 5A 250V / 3A AC5a Uncompensated 230V / 3A (690VA) AC5a Compensated 230V / 3A (690VA) max. input C=1uF HAL.230V AC5b 1000W Type of load K Contact material AgSnO 2, Contact 16A AC6a x AC7b 250V / 3A AC12 x AC13 x AC1 250V / 6A AC15 250V / 6A Type of load M M Contact material AgSnO 2, Contact 16A DC1 V / 10A DC3 V / 3A DC5 V / 2A - 7 - DC12 V / 6A DC13 V / 2A DC1 x

Description Output - channel 1 (16-15-18) Supply voltage terminal (A1) A1 16 15 18 7 Auto Display with back-light 0 6 12 Place for seal SHT-1/2 RESET MAN 2 MAN PRG ESC + _ OK Control buttons A2 26 25 28 Supply voltage terminal (A2) Output - channel 2 (26-25-28) - 8 -

Indicates the day in the week Operating modes indication Indication (1st channel) Indication of time/date/ menu Bargraf Control button PRG / + Reset Control button MAN1 / - 1 2 3 5 6 7 Auto Indication (2nd channel) Indicates 12 / mode Indicates summer / winter mode Control button MAN2 / ESC Control button OK E N CONTROL OF A DISPLAY WITH BACKLIGHT Display is illuminated with a back-light for 10 s from last button press. Permanent on / off is activated by synchronic press of buttons MAN, ESC, OK. After permanent on/off activation, display will flash shortly. - 9 -

oj Control, adjustment and program deleting date and time of programmed / random mode of pulse /cyclic mode interval holiday mode exit from menu Device differs short and long button press. In the manual marked as: - short button press (<1s) - long button press (>1s) / - number indicates button press sequence - entrance into programming menu - browsing in menu - of values - quick shifting during of values - entrance into required menu - confirmation - entrance into chosen program (EDIT) - one level up - back to the starting menu After 30s of inactivity (from the last press of any button) will device automatically returns into starting menu. - 10 -

Mode precendence Precendence of controlling modes highest priority of controlling mode lowest priority of controlling mode ual output control display - is superior to other set modes output mode ON / OFF manual control ON / OFF holiday mode ON / OFF auto random mode for switching ON / OFF / pulse-cyclic mode ON / OFF normal mode - controls channel 1 E N relay on relay off - 11 - - controls channel 2 (by SHT-1/2 and SHT-3/2)

0 6 SET 1 ram 7 6 5 3 2 1... ADD - add a new program - by SHT1/2 and SHT3/2 - selection of channel - by SHT-3 and SHT-3/2 - selection of daily / night mode OUT - of switching mode If the program memory is full, display announces it by notice FULL. - 12 - only by yearly mode: of year, month and day - of hour and minute of program start /end only by daily mode: ON/OFF - of the program activity in concrete day of the week - long press (>1s) - short press (<1s) / - press sequence

0 6 SET 1 ram adjustment 7 6 5 3 2 1 E N EDIT - adjustment of already saved programs - selection / entrance into chosen program - by SHT-1/2 and SHT-3/2 selection / adjustment of channel - by SHT-3 and SHT-3/2 selection / adjustment of set mode - 13 - OUT - selection / adjustment of switching mode only by yearly mode: adjusting of date (year, month and day) - time adjustment (hours / minutes) only by daily mode: ON/OFF - selection / adjustment of program activity in concrete day of the week - long press (>1s) - short press (<1s) / - press sequence

SET 1 ram deleting Deleting of all programs DEL - deleting of individual programs - program selection - long press OK - deleting of chosen program - 1 - - in starting menu (time is shown on display) - press simultaneously button PRG and OK and display announces a notice ALL - press button OK to complete the deleting of all set programs - long press (>1s) - short press (<1s) / - press sequence

SET 2 Date and time E N year month day of time in or 12 hour format hour minutes activation of changeover between summer/winter time - 15 - - long press (>1s) - short press (<1s) / - press sequence

0 6 SET 3 Setting of programmed / random mode Auto - by SHT-1/2 and SHT-3/2 - selection of channel PROG - relay is switching according programs set in menu SET 1 AUTO - relay is switching randomly in 10-120 min interval In starting mode by chosen channel flashs symbol or (Automatically preset switching according PROG). on display. - 16 - - long press (>1s) - short press (<1s) / - press sequence

0 6 SET Setting of pulse / cyclic mode interval E N - by SHT-1/2 and SHT-3/2 selection of channel - of pulse /cycle duration - of delay / cycle duration (by - pulse mode do not set) Setting of time of pulse / cyclic mode switching is realized by SET 1. - 17 - - long press (>1s) - short press (<1s) / - press sequence

SET 5 Holiday mode holiday mode holiday mode starting year holiday mode starting month holiday mode starting day holiday mode ending year holiday mode ending month holiday mode ending day In the starting mode during the activation of holiday mode, flashs symbol on display. - 18 -

End Exit from menu - return to the starting mode Reset 1 E N Activated by, covered RESET button, short press with blunt spike (with max. 2mm diameter). After press, information about type of device and firmware version will displayed for 3 s and then device performs in starting mode. Reset will delete an actual time, set time of pulse/cyclic mode and all temporary functions (manual or random switch output). Reset will save all set programs. - long press (>1s) - short press (<1s) / - press sequence - 19 -

Example of programming Setting of SHT-3/2 to be activated from Monday till Friday at 8:00 and deactivated from Monday till Friday at 16:30. 5 of switching on 2 3 7 1 6 starting menu programming add the program program 0 channel 1 daily program turn on a normal mode time of turning on of activity Mo-Fri turning off the activity Sat-Sun... save 5 of switching off 2 3 7 1 6... program 1 channel 1 daily program turn off a normal mode time of turning off of turning off activity the activity Mo-Fri Sat-Sun - 20 - save return into starting menu - long press (>1s) - short press (<1s) / - press sequence

Palackého 93 769 01 Holešov, Všetuly,CZ Tel.: +20 573 51 211 Fax: +20 573 51 227 E-mail: elko@elkoep.com Web: www.elkoep.com 2107; 2115; 2116; 2900; 2901-02VJ-00 Rev.: 3