APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

Similar documents
These drawings and single line diagrams provide an outlook of Basler Electric solutions for Excitation System installations and retrofit

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

DECS-200N-C1 Negative Forcing Digital Excitation Control System

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

www. ElectricalPartManuals. com .Basler Electric 15 Amp DECS DIGITAL EXCITATION CONTROL SYSTEM DESCRIPTION & SPECIFICATIONS pages 2 & 3

Class 300 Equipment CBS 305, 320 Current Boost Systems FEATURES. DESCRIPTION Page 2. SPECIFICATIONS Pages 2 through 4.

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Power Processor - Series 700F 10KVA to 150KVA

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Protective Relays Digitrip 3000

TOSHIBA International Corp

Power Supply Unit (550W)

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

FEATURES. Custom-designed DIGITAL EXCITATION CONTROL SYSTEMS For synchronous generators. Digital Excitation Control Systems

CLASS 200 EQUIPMENT EXCITATION SUPPORT SYSTEM

Multimeter 500CVD21 RTU500 series

Generator Protection GENERATOR CONTROL AND PROTECTION

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Thyricon Excitation System

N. TEST TEST DESCRIPTION

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Stabilized Differential Relay SPAD 346. Product Guide

Data Sheet. RISH Master Record %THD

Waterpower '97. Upgrading Hydroelectric Generator Protection Using Digital Technology

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

CROSS Chassis from 160 A to 450 A

PD300. Transformer, generator and motor protection Data sheet

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide

BE1-81O/U DIGITAL FREQUENCY RELAY FEATURES

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

N. TEST TEST DESCRIPTION

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

SEL-311C TRANSMISSION PROTECTION SYSTEM

BUS2000 Busbar Differential Protection System

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

1 INTRODUCTION ORDER CODE / INFORMATION

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

DPF-MAC Auto power factor controller

ULTRA RAPID POWER QUALITY ANALYZER

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS

D I G I T A L V O L T A G E R E G U L A T O R

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

Introduction: TAS PowerTek Ltd. MAVROS

O V E R V I E W O F T H E

LAUREL ELECTRONICS, INC.

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

INSTRUCTION MANUAL FOR DIGITAL EXCITATION CONTROL SYSTEM DECS-200

SPAD 346 C Stabilized differential relay

System Protection and Control Subcommittee

Technical Data Sheet AMIK 300 / 301

Excitation Systems. Service Generators SIPOL. Transistorized Excitation Systems for Synchronous Generators. Power Generation

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

COPYRIGHTED MATERIAL. Index

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

Microprocessor Control Board Set Up Procedures (OR PLC)

Generator Protection M 3420

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Digital Multifunction Instrument - Rish Master 3440

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Phase and neutral overcurrent protection

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Metering Devices, Protective Relays, Software and Connectivity

Excitation Systems RG3 - T4. Transistorized Excitation Systems for Synchronous Generators. Power Generation

Fuseless Capacitor Bank Protection

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

Power Meter Series PM3200 Functions and characteristics

T 1000 PLUS Secondary Injection Relay Test Set

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Generator Protection M 3425

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

ELKOR MOC1 TRANSDUCER SET - MANUAL

APPLICATIONS DATA SHEET. Product: Single Phase AC/DC Power Meter QI-POWER-485

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

This information is intended for use in the evaluations of applications for the Capstone Model C30 MicroTurbine.

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

The wireless alternative to expensive cabling...

TECHNICAL DATA SHEET B9600FXS kva

Generator Speed Controller Model GSC 1

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

FMR. Ultra Line FEEDER MANAGER RELAY

PEM353. Universal measuring device

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Transcription:

APPLICATION: Basler Electric offers a New Line of digitally controlled brush (static) or brushless excitation systems designed for use with existing Hydro, Gas as well as Diesel driven generators requiring high efficiency and reliability at a reasonable cost. The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges. The DSR excitation system is an ideal standard package for generators up to around 10 MW having field excitation requirement up to 200A. For Higher current ratings please contact Basler. Based exclusively on standard designs the DSR offers a cost effective solution for these applications while providing a high level of performance and reliability for the power generation system. Several configurations of our standard system are available either to be mounted in a compact enclosure (up to 80 Amps), in a free standing cubicle as well as on a metal chassis for installation within your existing cubicle. (Up to 200A) MAIN FEATURES: Micro-processor based DSR Digital controller +/- 1% Voltage regulation accuracy SCR based power rectifier bridges Multiple operating modes Easy to use Bestcom software for setup and testing High reliability Highly cost effective Available in compact enclosure, on chassis or in a cubicle Factory wired and tested Introductory Bulletin Rev D Page 1

INTRODUCTION The DSR excitation systems incorporate features and functions developed by Basler Electric after 15 years experience in digitally controlled Excitation and Voltage regulation products. Specifically designed as an easy replacement of aging Mini Hydro and Diesel excitation controls, the DSR system offers the advantages of multicontrol digital voltage regulation in a compact and Cost Effective package. The systems are designed to meet main field as well as exciter field requirements up to 200A with standard field voltages up to 250Vdc. DESCRIPTION The DSR system mainly consists of a metal chassis complete with the voltage regulator, power bridge, firing card controlling the SCR bridge and field flashing/discharge circuits. The panel version also include HMI through pushbuttons and indication lamps as well as metering instruments. The chassis can be supplied loose for assembly within your existing cubicle, fully assembled in an IP21 free standing cubicle or assembled in a wall mounted cabinet. (for critical space requirements above 80A) A RS 232 port with easy access provides means for local set up and control of the system using Basler user friendly Bestcom software. A crow bar discharge circuit and associated discharge resistance are included to provide deexcitation (Panel mounted system only). Excitation system: A DSR 100 Controller mounted with its firing card is the heart of the system. Inputs to the DSR 100 are generator voltage, B-phase Generator current, control power, Bus voltage (for voltage matching) and inputs and outputs for remote control of the system. Power potential Transformer (PPT): As an option, Basler offer a three phase power transformer as a loose item or mounted in the enclosure when possible. The PPT is to be connected to the generator output bus in shunt fed applications or from a station AC source. The PPT Kva is determined by the full load field power requirements and therefore sized according to the application. Introductory Bulletin Rev D Page 2

GENERAL SPECIFICATION Regulation: +/- 0.25% over the load range at rated PF and constant generator frequency. +/- 0.5% with 3 phase sensing and shunt power at 40% THD of the voltage waveform Regulation drift: +/- 0.5% for a 40 C change Regulation response: Within 1 cycle Voltage adjust range: +/- 15% of nominal Sensing input (1 or 3 phase) 50 Hertz Sensing Range 1: 100 Vac (85 to 132 Vac) Range 2: 200 Vac (190 to 220 Vac) Range 3: 400 Vac (380 to 440 Vac) 60 Hertz Sensing Range 1: 120 Vac (85 to 132 Vac) Range 2: 240 Vac (170 to 264 Vac) Range 3: 480 Vac (340 to 528 Vac) Range 4: 600 Vac (540 to 660 Vac) Dimensions: L x H x W mm Chassis: Custom or standard (?) Panel: Standard (610 x 2155 x 625 mm) Small cabinet: Standard (450 x 356 x 184 mm) Operating Temperature: 0 C to +45 C CONNECTION DIAGRAM EXAMPLE FOR THE SMALL CABINET Introductory Bulletin Rev D Page 3

R MECHANICAL LAY OUT OF THE PANEL A V V Introductory Bulletin Rev D Page 4

R MECHANICAL LAY OUT OF THE SMALL CABINET Introductory Bulletin Rev D Page 5

DSR 100 FUNCTIONAL DESCRIPTION: Stability 20 standard stability ranges are provided, as well as one customizable stability range for customized performance. The PC BESTCOMS software provides PID selection software and a sophisticated response time program to facilitate verification of stability performance. Front Panel Annunciation The DSR-100 Main controller provides seven LEDs to indicate generator system and DSR-100 conditions without requiring connection to the communications device. Protection Two protection functions have the ability to be user-programmed to shut down the DSR-100 and close the alarm contact. They are: Generator Overvoltage Loss of sensing Voltage Voltage Matching This function allows the DSR-100 to match the bus voltage prior to synchronizing. This feature replaces the same function in the automatic synchronizer, thereby saving money by allowing the use of a less expensive synchronizing device. Softstart Softstart functions as a voltage limiter during generator build-up. It limits the generator voltage overshoot typically present when machines are initially started. VAR/PF Control Integrated VAR/PF controls save the user the cost of purchasing and installing remote devices that perform the same functions. This function is typically used on utility-paralleled generators that cannot control the grid voltage. Once set, the VAR or PF of the generator output will be regulated. External Adjustments The DSR-100 allows for multiple points and methods of external adjustment of the active regulation mode. There are three methods for adjustment: Contact input Auxiliary voltage input (+/- 3 Vdc) PC adjustment (BESTCOM) The PC communications also can change operating modes and set points. Introductory Bulletin Rev D Page 6

COMMUNICATIONS: PC (Windows 95, 98, 2000, NT, Me, XP compatible) communications software is provided free of charge by Basler Electric with every DSR-100 units. The PC BESTCOMS allows for total setup, control, and monitoring of all parameters of the DSR-100. It allows for custom PID selection and has a monitoring screen for viewing all generator parameters in actual machine levels. The RS-232 DB9 connector used for communication with BESTCOM. This software is on a single CD- ROM along with the instruction manual and product bulletin. BESTCOM Software window (setting screen) BESTCOM Software window (analysis screen) BESTCOM Software window (metering screen) Introductory Bulletin Rev D Page 7

OPTIONS GENERATOR PROTECTION BE1-GPS100 (available in option for the panel solution only) The relay system provides protection, monitoring, local and remote control, and standard automation protocols. Relay self-checking functions are included. The relay system comes with a 7-year warranty. For further details refer to technical product bulletin UHQ. ANSI Code VOLTAGE PROTECTION ANSI Code OVERCURRENT PROTECTION 24 Volts per Hertz Over-excitation Protects against transformer and generator overexcitation conditions. 50/51 Phase Faults Single phase instantaneous overcurrent element. 27/59 Phase Under/Overvoltage 2 phase undervoltage and overvoltage elements for detecting single or multiphase voltage events. 50N/51 N Ground Faults Neutral instantaneous overcurrent element and 2 neutral time overcurrent elements that operate on calculated residual (3I0) 27/59X Auxiliary voltage protection: 2 undervoltage and overvoltage elements that monitor phase residual voltage (3V0) for detecting grounds on a delta system. 46 Negative Sequence Current Detection of unbalanced loading and phase faults. 47 Negative Sequence Overvoltage for detecting phase unbalance and reverse phase rotation. OTHER PROTECTIONS 60FL Fuse Loss Detection Protects against false tripping for a blown sensing fuse. 25 Synchronism Check This protection shall check for phase angle difference, voltage magnitude difference, frequency difference (slip) and if the 3-phase VT source voltage frequency is greater than the auxiliary VT frequency. 81 O/U Under/Overfrequency (81O/U) The relay includes 6 frequency elements for detection of power system frequency disturbances. 32 Directional Power Sensitive power elements that can be independently set forward or reverse. Together with protection the BE1 GPS offers the following Control and Monitoring features Reporting and Alarms: Oscillography and Sequential Events Recorder (SER): Demand Metering Circuit Breaker Monitoring Communications: Relay Interface Front and rear RS-232 port Rear RS-485 port : Supports ASCII, Modbus or DNP3.0 option PC Interface Windows -based graphical user interface and ASCII terminal interfaces. PC Software: compatible with Windows 98, NT, 2000, XP Home, XP Professional, and Me Inputs/Ouputs Introductory Bulletin Rev D Page 8

LOCAL / REMOTE CONTROL USING PLC (AVAILABLE ONLY IN PANEL SOLUTIONS) To supervise the excitation system, a PLC is used thus allowing to control with the system in a simple and easy way. Features and Dialogue The PLC controls the management of faults which appear in the system. After processing the signals may be used taken to a console to inform an operator. Appropriate measures may then be taken to avoid the system deterioration. With an HMI, the PLC can indicate the system state, system fault as well as their nature. POWER TRANSFORMER Power for the excitation system is usually derived from the generator via a large KVA transformer. The transformer steps down the generator terminal voltage to be compatible with the field s requirements and also fix the forcing ratio of the system. The transformer will provide the excitation system s full load rating, plus a voltage and KVA margin for accommodating short time field forcing to handle generator transient overload requirements. The power (KVA) and secondary voltage will limit the maximum amount of power delivered to the field (forcing conditions). The PPT is typically sized to have a forcing ratio ( [Max. voltage] / [Nominal voltage] ) between 1.4 to 2. A power potential transformer could be replaced by any other AC source if the power needed for the excitation is sufficient. An optional cover can be quoted upon request to protect the transformer. Type Standard Primary voltage Power (Kva) Frequency Connection Dry Sized per application Sized per application 50 or 60 Hz Yd11 The power transformer is quoted separately for every application based on demand. Introductory Bulletin Rev D Page 9

MAIN CHARACTERISTICS Digital controller DSR-100 Assembly Small cabinet Type 50 Type 80 Cubicle Mounting plate Generator size (max) 10MW DC Output current (max) 50A 80A 200A DC Output voltage (max) 200V 250V DC Forcing current (max) 80A / 10 secs 130A / 10 secs 400A / 10 secs Field resistance 0.8-12 Ohms 0.5-4 Ohms 0.2-3 Ohms Response time Less than 1 cycle Rectifier type 3 SCRs 3 SCRs 6 SCRs Discharge Field flashing circuit Options available Free wheel diode Not included Excitation transformer Crowbar + fast discharge resistor Yes from 100-400Vac supply Digital network analyzer Generator protection ACTUALLY BEING DEVELOPPED Auxiliary power supply 24Vdc Excitation transformer 24 Vdc, 100-250Vac or 100-300Vdc Introductory Bulletin Rev D Page 10

ORDERING INFORMATION To place your order and verify the interface between the DSR solution and your system, simply fill in the following data sheet and forward it to your nearest Basler Electric Representative. The data with this (*) sign are absolutely necessary Customer Name: Project name : 1) Generator Output data : Power (in kva) : (*) Voltage (in V) (*) Frequency (in Hz) : Power factor : 2) Excitation Field Data : Current at no load: Voltage at no load: Current at full load: (*) Voltage at full load: (*) 3) Forcing ratio : Typically 1.6 times the excitation voltage at full load : 4) EXCITION TRANSFORMER: Quotation requested?(y/n) Connected on generator terminals? If no, voltage available: 5) CT & PT ratio for the sensing circuit : PT RATIO CT RATIO a) Primary voltage : a) Prim Current : b) Secondary voltage : (*) b) Sec Current (1 or 5A) (*) c) App Power (25VA min) c) Burden (in VA) : d) Single or 3 Phase : d) Plugged on V phase?: 7) Control power supply available (24Vdc recommended): Voltage available (Please also confirm AC or DC): (*) 8) Power source available for the field flashing: (if used) Voltage available (Please also confirm AC or DC): (*) 10) Size of the equipment : (Max space available for mounting plates only) Height : Width : Depth : Introductory Bulletin Rev D Page 11

The information included in this introductory document is subject to change without notice and is intended for general information only. If you would like further information on these systems or any of the Basler Excitation System range, please feel free to contact us at one of the addresses in your region as listed below. USA and Americas: Basler Electric USA China: Basler Electric China Rest of the world: Basler Electric France P.A.E. Les Pins P.O. Box 269 N 1300 Zhong Shan BEI Lu Dev 67 319 Wasselonne Highland Il. 62249 Zone, Suzhou, Jiangsu Province France United States People Republic of China Tel : +33 (0)3 88 87 10 10 Tel : +1 618 654 2341 Tel : +86-512-6346-1730 Fax : +33 (0)3 88 87 08 08 Fax : +1 618 654 2351 Fax : +86-512-6346-1760 Mail : beifrance@basler.com Mail : info@basler.com Mail : beichina@basler.com Introductory Bulletin Rev D Page 12