Thyristor power controller B DI1002 V1.0 Manual/Operating instructions

Similar documents
Power supply CP-E 24/20.0

Power supply CP-D 24/1.3

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

QUINT-PS/ 3AC/24DC/10

Power supply CP-D 12/2.1

IF30. User's manual. Description. Table of contents IF30

QUINT-PS/ 3AC/24DC/40

Power supply CP-E 24/0.75

MINI MCR-SL-UI-f(-SP)

QUINT-PS/ 1AC/24DC/20

MINI-PS AC/24DC/1.3

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Power supply CP-D 24/4.2 Primary switch mode power supply

Electronic timer CT-TGD.22

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Type CP-S, CP-C & CP-A Switch mode

QUINT-PS-24DC/24DC/10

MINI-PS AC/2X15DC/1

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Output Voltage* (nom.)(adjustable)

XF2 Frequency Relay. Manual XF2 (Revision A)

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Electronic timer CT-SDD.22

QUINT-PS AC/24DC/40

Immunity Testing for the CE Mark

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Overcurrent Protection / 7SJ45

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Power supply CP-T 48/20.0 Primary switch mode power supply

Proportional amplifier type EV22K5

High precision measurement system for current and voltage IHC-A/B-RM01/03

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Product Specification sheet

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

XUA1 - AC Voltage and phase balance relay

Power supply CP-T 24/40.0 Primary switch mode power supply

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Power supply CP-T 24/20.0 Primary switch mode power supply

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Output Voltage nom. (adjustable)

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

08/07/2015

Output Voltage nom. (adjustable)

BIODEX MULTI- JOINT SYSTEM

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

CP-T range Product group picture

MID energy meter B21 Single-phase energy meter, 65 A

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Controls Solid-State Switching Devices

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Subject to changes 11/2003 Page 1/7

XP2-R Power and Reverse Power Relay

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Scale Manufacturers Association (SMA) Recommendation on. Electrical Disturbance

CP-T range Benefits and advantages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

CB Scheme UL508 UL ATEX II3G

XN2 - Mains decoupling relay. Manual XN2 (Revision C)

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

Three-phase monitoring relays

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

RS Pro ENGLISH. Datasheet

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Industrial motor controller for brushed DC motors 12 VDC

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Liquid level monitoring relay CM-ENS.2x

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

02/11/2015

MDW-45 Converter RS RS-422/485

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast

02/11/2015

02/11/2015

PRetrans Table of contents

Appendix A: Specifications

Electronic timer CT-MFS.21

Transcription:

1 B DI1002 V1.0 Manual/Operating instructions

2 1 Introduction Before you put the thyristor controller into operation, please read these operating instructions. Keep them in safe place accessible for all users. We would appriciate any suggestions for the improvement of these operating instructions you may wish to send us. If in the course of putting the thyristor controller into operation any problems arise, please do not carry out any adjustments to the device. If you do, you run the risk of loss of entitlement to make claims under the guarantee! In that case we would ask you to get in touch with us. 07021-50998-0 07021-50998-99 j.rarbach@vorschaltgeraete.de In the case of return shipments of electronic sub-assemblies or printed circuit boards, the provisions for the protection of electrostatically endangered components are to be observed. For transportation use only ESD packaging intended for this purpose. Please note that no liability can be accepted for damage or loss caused by ESD. ESD = electrostatic discharge

3 2 Use This thyristor power controller was developed for use for the control of gas discharge reflector lamps. Various equipment features of the control electronics are adapted to the process control of plasma arc discharges. As a matter of principle, the thyristor power controller is suitable for all of the usual phase control applications with resistive and inductive consumer load. 3 Operating mode The thyristor power controller works according to the principle of the voltage-time area control with adjustable power range and adjustable current range. 4 Control system The thyristor power controller works according to the principle of the voltage-time area control and is suitable for operation on resistive and inductive loads. During the control process, mains voltage fluctuations have no influence on the section to be controlled. This is ensured by an active power meter at the consumer load. The device has three analogue inputs for standard signals (voltage or current), via one channel the set value for the power to be set being specified. The second channel permits the specifying of a maximum power which must not be exceeded. The third channel makes it possible to specify a current. The control section contains two separate controllers for power and current, the controller to which, due to the process, a limiting task has been assigned, by means of a transfer circuit automatically takes over control of the section. The thyristor power controller is switched on with 24 volts control voltage on the pulse release control contact, with the resetting of the pulse release also the integral action components of the controllers and the setpoint value integrator are discharged. Two potential-free contacts are available for fuse breakage and excess temperature. The thyristor power controller measures the genuine effective values of voltage and current on the consumer load as well as the genuine active power. All three variables can be output simultaneously as

4 standard signals via three analogue channels (voltage or current) and be used for process visualization or for feeding to a higher-priority process control system. 5 Design The power section consists of two anti-parallel connected thyristors, the heat sink and the control electronics. In order to measure and record the consumer voltage and the consumer current, a voltage transformer and a current transformer (included in the scope of supply) must be connected externally. This circuit topology is necessary because, for the operation of a gas discharge reflector lamp, non-linear inductivities have to be connected between the thyristor power controller and the gas discharge reflector lamp. 6 Regulations for CE conformity The following standards and regulations form the basis and are observed to the extent that they are applicable: Emitted interference Basic specification DIN EN 61000-6-4 Radio interference voltage at the power supply terminals EN 55011 Class A Interference field strength EN 55011 Class A Noise immunity Basic specification DIN EN 61000-6-2

5 Discharge of static electricity EN 61000-4-2 4 KV CD, 8 KV AD High-frequency electromagnetic fields EN 61000-4-3 80 1000 MHz, 10 V/m 80 % AM, KHz Fast transients EN 61000-4-4 2 KV, 5/50 ns, 5KHz alternating current mains input Surge voltages/surge currents EN 61000-4-5 1.2/50 (8/20) Tr/Th in µs 4 KV unsym. / 2 KV sym Conducted high frequency EN 61000-4-6 0.15 80 MHz, 10 V, 80 % AM, I KHz Voltage dips EN 61000-4-11 30 % reduction, 10 ms 60 % reduction, 100 ms Voltage interruptions EN 61000-4-11 95 % reduction, 5000 ms Electrical safety Electronic equipment for use in power installations EN 50178 Protection from electric shock EN 50274 7 Accessories If the thyristor power controller is not used for operation on a gas discharge reflector lamp, as an accessory a fast semi-conductor fuse can be used. The fuse can be used with an appropriate holder on a standard rail or screwed

6 onto the built-on plate. The arrangement of the fuse outside of the thyristor power controller facilitates fuse replacement in the event of a fault. For operation of the thyristor power controller on a gas discharge reflector lamp the semi-conductor fuse is not necessary if inductors and transformers from Diez are used as the ballast. These are rated in the technical calculation in such a way that a maximum current rise upon consumer short-circuit is not exceeded. For easy visualization of the electrical variables on the consumer load, the software package DIMO is available. With Dimo the voltage, current and active power at the consumer load can be observed, and represented as a y-t diagram and saved. The saved curves can be measured with the cursor. Dimo is not necessary for the commissioning of the thyristor power controller, it is used merely for easy process visualization. 8 Important installation notes Safety notes For the choice of the lead and cable material, for installation and for electrical connection of the thyristor power controller, the regulations of VDE 0100 "Provisions concerning the construction of electric power installations with rated voltages below AC 1000 volts" or the respective national regulations are to be observed. The electrical connection must be carried out only by specialist personnel. If during work live parts can be touched, the device must be disconnected from the mains at all terminals. Earthing The earthing is to be effected in accordance with the regulations of the responsible utility company.

7 Interference suppression The electromagnetic compatibility is in compliance with the standards and regulations listed. Wiring Load and control lines are to be installed separately. For the protection of the lines appropriate fuses are to be provided. Compare the data stated on the rating plate (voltage and current) with the equipment data. Set encoding switch for analogue inputs and analogue outputs. Connect the power supply for the control electronics in accordance with the terminal connection diagram to terminals "L1" and "L2". The electronic switch (2 anti-parallel connected thyristors) is between the connections "U1" and "U2" The power supply for the control electronics and the load voltage must have the same phase angle (synchronization) Closing sequence The power supply for the power and control circuits must be switched on at the same time. The power supply for the control circuit (L1, L2) may only be switched on earlier if the pulse release input has not yet been set and running up of the controllers without consumer load is prevented. That is particularly important during operation of transformer load and with resistive loads with a large hotcold resistive ratio.

8 In general the pulse release should only be set when all power supplies have been switched on. That permits safe control over the point in time at which the electric power starts on the consumer load. Filtering and interference suppression To avoid radio interference as naturally arises during generalized phase operation, electrical operating equipment and units have to have radio interference suppression. The control electronics of the thyristor power controller are in compliance with the EMC requirements. Sub-assemblies for generalized phase operation, however, do not in themselves serve any application purpose. They are only a functional unit of an overall plant. Therefore the constructor of a unit must suppress any interference in this unit with the help of suitable filters. Interference suppressor filters are offered as sub-assemblies ready for connection by companies specializing in this field. Place of installation and climatic conditions As far as possible the place of installation should be free of vibrations and closeness to strong electromagnetic fields should be avoided if at all possible. The ambient temperature at the place of use must be 0 45 degrees Centigrade at a relative humidity of < 75 %. As a matter of principle the thyristor power controller is intended for use in dry rooms. The preferred fitting direction is vertical because of the better convection. Care must be taken to ensure adequate ventilation of the switch cabinets. The thyristor power controller is not suitable for use in explosion-hazard areas. The place of installation must be free of aggressive media.

9 9 Designation of the control terminals internal X101 X5 monitoring Temperature- 1 monitoring 2 3 4 internal X105 X107 internal X108 internal internal X106 internal X109 internal X201 X2 analogue in 6 GND 5 Imax 4 GND 3 Pmax 2 GND 1 Preq. X10 analogue out 6 GND 5 Current 4 GND 3 Voltage 2 GND 1 Power X3 ref/run/stop 10 volts ref. 1 GND 2 Pulse relaese 3 GND 4 24 volts ref 5 X4 C/V transformers 4 b 3 a 2 l 1 k

10 10 Encoding switch and potentiometer 1 Imax A Pot Imax 2 Imax B 3 Imax C 4 Pmax A Pot Pmax 5 Pmax B 6 Pmax C 7 Psoll A 8 Psoll B Pot Preq 9 Psoll C 10 Actual value monitoring ON/OFF 1 Iout A 2 Iout B Iout life zero ON/OFF 1 Uout A 2 Uout B Uout life zero ON/OFF 1 Pout A 2 Pout B Pout life zero ON/OFF

11 Encoding switch for analogue inputs Table for Imax encoding switch Imax A Imax B Imax C Function 0 0 0 0-10 volts 0 1 0 0-5 volts 1 0 0 0-20 ma 0 0 1 Specification via pot on the printed circuit board Table for Pmax encoding switch Pmax A Pmax B Pmax C Function 0 0 0 0-10 volts 0 1 0 0-5 volts 1 0 0 0-20 ma 0 0 1 Specification via pot on the printed circuit board Table for Preq encoding switch Imax A Imax B Imax C Function 0 0 0 0-10 volts 0 1 0 0-5 volts 1 0 0 0-20 ma 0 0 1 Specification via pot on the printed circuit board Actual value monitoring encoding switch ON : OFF: special mode of operation for inductor parallel operation ( transition inductor) Normal setting for all usual applications

12 Encoding switch for analogue outputs Table for Iout encoding switch life zero OFF life zero ON IoutA Iout B Function Function 0 0 0-20 ma 4-20 ma 0 1 0-10 volts 2-10 volts 1 0 0-10 volts 2-10 volts 1 1 0-5 volts 1-5 volts Table for Uout encoding switch life zero OFF life zero ON UoutA Uout B Function Function 0 0 0-20 ma 4-20 ma 0 1 0-10 volts 2-10 volts 1 0 0-10 volts 2-10 volts 1 1 0-5 volts 1-5 volts Table for Pout encoding switch life zero OFF life zero ON PoutA Pout B Function Function 0 0 0-20 ma 4-20 ma 0 1 0-10 volts 2-10 volts 1 0 0-10 volts 2-10 volts 1 1 0-5 volts 1-5 volts