INSTRUCTION MANUAL PCE-222

Similar documents
INSTRUCTION MANUAL MODEL 8820 Multi-Function Environment Meter

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

Model ST Instruction Manual. Light Meter. reedinstruments www.

Manual DATALOGGING LIGHT METER - PCE-174

DIGITAL MULTIMETER OPERATOR S MANUAL

DIGITAL ILLUMINANCE METER MODEL 1308 INSTRUCTION MANUL

DIGITAL LIGHT METER TES-1337 INSTRUCTION MANUAL CONTENTS

Manual Electric resistance tester PCE-MO 2001

User's Guide. EasyView Light Meter with Memory. Model EA33. Introduction

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

USER GUIDE. White LED Light Meter. Model LT Washington Street Melrose, MA Phone Toll Free

EasyView Light Meter with Memory

EM5. Multifunctional Environmental Meter. Sealed Unit Parts Co., Inc. User Manual

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

User Guide. EasyView Digital Light Meter. Model EA31

LUX/FC LED Light Meter TM-201L / TM-209 User s manual

Dawson DSM150. Digital Light Meter User s Manual

LUX/FC LED Light Meter TM-201L / TM-209/TM-209N /TM-209M

Advanced Test Equipment Rentals ATEC (2832)

Heavy Duty Meter Model

OPERATOR S INSTRUCTION MANUAL

Model Digital Light Meter

LIGHT INTENSITY METER

OPERATIONS MANUAL DP-110 IN-DUCT DIGITAL PSYCHROMETER TABLE OF CONTENTS

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

INSTRUCTION MANUAL DIGITAL MULTIMETER

30XR-A Professional Digital Multimeter Users Manual

DIGITAL MULTIMETER OPERATION MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

MANUAL PCE-UT232

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

MS2030 CAT III 600 V A V AUTO RS232

3423 LUX HiTESTER INSTRUCTION MANUAL

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

DIGIT & POINTER MULTIMETER

AC/DC CLAMP METER USER S MANUAL

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Manual TRMS Multimeter PCE-UT 61E

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

OPERATING INSTRUCTION

Digital Clamp Meter (TRMS) Model : 2727

DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGITAL MULTIMETER. MODEL CDM-50 Part No OPERATING INSTRUCTIONS

Digital Clamp Meter Model: &

COMPLY WITH HI-VOLTAGE PHASE CURRENT MEASUREMENT M-140HC INSTRUCTION MANUAL

DIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

DVM1190 DIGITAL MULTIMETER

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

DMM8900 SERIES USERS MANUAL

Dawson DDM190. Digital Multimeter User s Manual

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

Model DIGITAL MULTIMETER

Table of Content. The Statement Safety Statement Safety Instructions Safety Operation Specifications Safety Symbols...

INSTRUCTION MANUAL PCE-HT 500

MS8223A. CAT.IIi 600 V

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

INSTRUCTION MANUAL PCE-HT 550

AMM-1022 Digital Multimeter USER`S MANUAL

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Accuracy : ± (0.8% rdg + 1dgt) on all ranges except Ranges : 200mV, 2V, 20V, 200V, 1000V

DIGITAL MULTIMETER AUTORANGING

VC835 DIGTAL MULTIMETER Operation Manual

Read and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as

MULTIMETRE DIGITAL 3 3/4 AVEC ECHELLE AUTOMATIQUE & EXTINCTION AUTOMATIQUE MANUEL D UTILISATION

Printing Humidity/Temperature Meter

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

AC CURRENT UNIVERSAL CLAMP TESTER MODEL 310 INSTRUCTION MANUAL

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

TES-1306 DIGITAL THERMOMETER INSTRUCTION MANUAL 1. SAFETY INFORMATION

Analog Technologies VC99. Multimeter FEATURES

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

SAFETY PRECAUTIONS: Before use, read the following safety precautions

SUBJECT TO CHANGE WITHOUT NOTICE

Multifunction Digital

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

MW3105 DIGITAL CLAMP MULTIMETER

UT207A/208A/209A Operating Manual. Table of Contents

Digital Clamp Meter. User Manual

Cat# Multi-functional LED Light Meter

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

Model : OPERATING MANUAL Table of Contents (1)

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Transcription:

www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk http://www.industrial-needs.com/ INSTRUCTION MANUAL PCE-222

TABLET OF CONTENTS INSTRUCTION MANUAL... 1 1. INTRODUCTION... 3 2. FEATURES... 3 3. SPECIFICATIONS... 3 4. PANEL DESCRIPTION... 4 5. OPERATING INSTRUCTION... 5 6. MAINTENANCE... 6 2

1. INTRODUCTION The 4 in 1 digital multi- Multi-Function Environment Meter has been designed to combine the functions of Sound Level Meter, Light Meter, Humidity Meter, and Temperature Meter. It is an ideal Multi-Function Environment Meter Instrument with scores of practical applications for professional and home use. The Sound Level function can be used to measure noise in factories, schools, offices, airports, home, etc., checking acoustics of studios, auditoriums and hi-fi installations. The Light function is used to measure luminance in the field. It is fully cosine corrected for the angular incidence of light. The light sensitive component used in the meter is a very stable, long life silicon diode. The Humidity / Temperature is for use a humidity / semiconductor sensor and K type thermocouple. This operations manual contains general information and specification 2. FEATURES Optically isolated PC interface-optional RS-232 cable and windows 95/98/2000 compatible software allows user to collect display, plot and save data 4 functions measure Sound level, Light, Humidity, and Temperature. 4000 count large LCD display with units of Lux, o C, %RH and db indication. Easy to use with single function switch operating, pocket size and light weight. Sound level measures from Lo: 35dB to 100dB/ Hi: 65dB to 130dB for A weighting checking with 0.1dB resolution. Light measuring levers ranging from 0.01 lux to 40,000 lux. Humidity measurement from 25%RH to 95%RH with 0.1%RH resolution and fast time response. 3. SPECIFICATIONS Display: 4000 counts LCD display with function of Lux, o C, o F, %RH and db indication. Polarity: Automatic, (-) negative polarity indication. Over-range: OL mark indication. Low battery indication: The BAT is displayed when the battery voltage drops below the operating level. Measurement rate: 1.5 times per second, nominal. Storage temperature: -10 o C to 60 o C (14 o F to 140 o F) at < 80 % relative humidity Power: One standard 9V, NEDA1604 or 6F22 battery. Dimensions: 121.5 (H) x 60.6 (W) x 40 (D) mm Weight: Approx.: 280g including holster. Sound Level Measurement range: Lo: 35dB -100dB; Hi: 65dB~130dB Resolution: 0.1dB Typical instrument frequency range: 30Hz-10 KHz Frequency Weighting: A weighting Time Weighting: Fast Accuracy: +3.5 db at 94 db sound level, 1KHZ sine wave. Microphone: Electric condenser microphone. Light Measuring Range:40, 400, 4000, 40,000lux (40,000lux range reading x10) Overrate Display: Highest digit of OL is displayed. Accuracy: +5% rdg + 10 dgts (calibrated to standard incandescent lamp at colour temperature 2856 k). Repeatability: + 2%. 3

Temperature Characteristic: +0.1% / o C. Photo detector: One silicon photo diode with filter. Humidity / Temperaturee (Auto-ranging) Measurement Range: Humidity 25%~95%RH Temperature: -20.0 ºC-+ +400.0 ºC, -20 ºC -+750 ºC, -4.0 -+400.0, -4 -+1400 Resolution: 0.1% RH, 0.1 ºC or 1 ºC / 0.1 or1. Accuracy (after calibration): Humidity: + 5%RH (at 25~, 35%~95% RH). Response time of the humidity sensor: approx. 6 min. Temperature: +3% %rdg + 2~ (at -20 ºC ~+400.0 ºC) +3.5%rdg + 2~ (at -20 ºC ~+ +750 ºC) +3% %rdg + 2~ (at -4.0 ~+400.0 ) +3.5%rdg + 2~ (at -4 ~+1400 ) Input Protection: 60V dc or 24V ac rms. 4. PANEL DESCRIPTION 1. LCD display: 4000 count LCD display with units of Lux, x10 Lux, o C, o F, %RH, db and low battery BAT indication. 2. Power / Function / Range Switch: Turn power on (or off) and select measurement function and ranges. 3. Microphone: Electric condenser microphone inside. 4. Photo Detector: Long life silicon photo diode inside. 5. Humidity & Temperature: Humidity Sensor and Semiconductor Sensor inside. 6. Temperature Terminal: Insert the temperature probe in this terminal. 7. RS-232 Terminal: Computer Interface Transport Terminal 4

** 8. RS-232 wires: Connect the RS-232 wires to the meter s RS-232 interface 5. OPERATING INSTRUCTION Measuring Sound Level 1. Turn the Power/function/range Switch to db position. 2. Remove the meter and face the microphone to sound source in a horizontal position. 3. The A -weighting curve is nearly uniform over the frequency range from 30 to 10,000Hz, thus giving an indication of overall Sound level. 4. The Fast response is suitable to measure shout bursts and peak values from sound source. 5. The sound level will be displayed. 6. Note: Strong wind (over 10m/sec.) striking the microphone can cause misreading for measurement in windy locations; a windscreen should be used in front of microphone. Measuring Light 1. Turn the Power/function/range Switch to select the lux scale and set the range to desired ( lux or x10 lux ) range. 2. Remove the meter and face the photo detector to light source in a horizontal position. 3. Read the illuminance nominal from the LCD display. 4. Over-range: If the instrument only display one OL in the M.S.D. the input signal is too strong, and a higher range should be selected. 5. When the measurement is completed. Replace the photo detector from the light source. 6. Spectral sensitivity characteristic: To the detector, the applied photo diode with filters makes the spectral sensitivity characteristic almost meet C.I.E. (International Commission on Illumination) photopia curve V () as the following chart described. 100% (Relative Sensitivity) Spectral Sensitivity 80 ºC V( ) 60 ºC 40 ºC 20 ºC 0 400 500 600 700 800 Wavelength (nm) 7. Recommended Illumination: Locations Lux *Office Conference, Reception room. 200 ~ 750 Clerical work 700 ~ 1,500 Typing drafting 1000 ~ 2,000 *Factory Packing work, Entrance passage 150 ~ 300 Visual work at production line 300 ~ 750 Inspection work 750 ~ 1,500 Electronic parts assembly line 1500 ~ 3,000 *Hotel Public room, Cloakroom 100 ~ 200 Reception, Cashier 200 ~ 1,000 *Store 5

Indoors Stairs Corridor 150 ~ 200 Show window, Packing table 750 ~ 1,500 Forefront of show window 1500 ~ 3,000 *Hospital Sickroom, Warehouse 100 ~ 200 Medical Examination room 300 ~ 750 Operating room Emergency Treatment 750 ~ 1,500 *School Auditorium, Indoor Gymnasium 100 ~ 300 Class room 200 ~ 750 Laboratory Library Drafting room 500 ~ 1,500 Measuring Humidity/Temperature 1. Humidity Measurement: 1. Set the Power/function/range Switch to %RH position. 2. Then the display will show the humidity reading value (%RH) directly. 3. When the tested environment humidity value changed. It need to a few minutes to get the stable %RH reading. Warning: Don t expose the humidity sensor to direct sunlight. Don t touch or manipulate the humidity sensor. 2. Temperature Measurement: 1. Set the Power/function/range Switch to 0.1 o C or 1 o C and 0.1 or 1 position. 2. Then the display will show the environment temperature reading value ( o C/ ) directly. 3. Insert the temperature probe into the K-type thermocouple socket. 4. Touch the end of the temperature sensor to the area or surface of the object to be measured. The display will show the temperature reading value ( o C/ ) directly. Warning: When function switch on temperature 0.1 o C or 1 o C and 0.1 or 1 range, never attempt a voltage measurement with the test leads inserted into the K-type thermocouple socket. You might be injured or damage the meter. RS-232 INTERFACE MEASUREMENTS 1. Connect the RS-232 wires to the meter s RS-232 interface and PC COM port., the indicator RS232 will be appear in the display. 2. PC will display the meter s measuring model. Note: First of all please read the README file in the attached soft disk and then comply with it set the SET UP Program from soft disk up to your PC. 6. MAINTENANCE Battery Replacement If the sign BAT appears on the LCD display, it indicates that the battery should be replaced. Remove screws on the back cover and open the case. Replace the exhausted battery with new batteries. (1 x 9V battery NEDA 1604, 6F22 or equivalent) 6

In this direction will find a vision of the measurement technique: http://www.industrial-needs.com/measuring-instruments.htm NOTE: "This instrument doesn t have ATEX protection, so it should not be used in potentially explosive atmospheres (powder, flammable gases)." 7