Fluke 125. Getting Started. Industrial ScopeMeter

Similar documents
Fluke 123/124 Industrial ScopeMeter

Fluke 123/124. Users Manual. Industrial ScopeMeter

Fluke 123/124. Users Manual. Industrial ScopeMeter

Fluke 192/196/199. MS 190 and MA 190. Users Manual Supplement

92B/96B/99B/105B. Users Manual. ScopeMeter

Fluke 19xC-2x5C. Users Manual. ScopeMeter. Software version 8.00 onwards

123B/124B/125B. Users Manual. Industrial ScopeMeter

Fluke 192/196/199. ScopeMeter. Users Manual

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

ScopeMeter 190 Series II

The Meter Structure The Figure 2-1 shows the Meter structure.

Fluke MDA-510 and MDA-550 Motor Drive Analyzer

287/289. True-rms Digital Multimeters. Users Manual

80i-110s AC/DC CURRENT PROBE

Technical Specifications 190 Series

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Fluke 43B. Fluke-Direct.com. Power Quality Analyzer. Users Manual

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Fluke 43B. Power Quality Analyzer. Users Manual

AX-C Introduction. 2. Safety Information

Fluke 434-II/435-II/437-II

Digital Clamp Meter Model: &

287/289. Users Manual. True-rms Digital Multimeters

6688A Scope Meter User s Manual

Model and

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Fluke 434-II/435-II/437-II

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Fluke-Direct.com. Fluke 120B Series Industrial ScopeMeter Hand-Held Oscilloscopes TECHNICAL DATA

Oscilloscopes for field applications

Hand-Held Oscilloscopes

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

MC133C/133Ci. Electric Power/Energy Calibrator. Operation manual

Fluke199XRAY. Users Manual. Medical ScopeMeter

UT232. Operating Manual. Digital Power Clamp Meter

Digital 20MHz and 60MHz Oscilloscopes

True-RMS Digital Multimeter User Manual

867B/863. Users Manual. Graphical Multimeter

51-54 Series II. Thermometer

400Amp True RMS AC/DC Clamp Meter Model EX613

Fluke 120B Series Industrial ScopeMeter Hand-Held Oscilloscopes

Model UT233 OPERATING MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

79/26 Series III Multimeter

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

ET-3888 True RMS Clamp Meter. User Manual

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Model 7000 Low Noise Differential Preamplifier

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

User Manual Digital Multimeter. model no.: MSR-U1000

600A Clamp Meters w/tightsight Display

Model 77 Series IV. Digital Multimeter. Users Manual

400Amp True RMS AC Clamp Meter + NCV

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

User's Guide. Digital 20MHz and 60MHz Oscilloscopes. Model MS460-60MHz Model MS420-20MHz

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

ScopeMeter Test Tool Innovation Introducing the complete 190 Series II Technical Data

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

312, 316, 318. Clamp Meter. Users Manual

374/375/376 Clamp Meter

USER'S MANUAL DMR-6700

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

User Manual. Model MHz Dual Channel. True RMS Oscilloscope Datalogger

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

ScopeMeter 190C, 190B, and 120 Series

ScopeMeter 190C/190B Series and ScopeMeter 120 Series

HDS1022M Handheld DSO & DMM. Table of Contents. 1.1 Declaration of Conformity 1

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Electrical Multimeter

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Oscilloscopes for field applications

Analog Technologies. Multimeter 115C and 117C

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

DM-45 Digital Multimeter

5MHz FUNCTION GENERATOR

374/375/376 Clamp Meter

USER MANUAL Clamp Meters ACM-2353

Electrical Multimeter

ScopeMeter 190 Series and ScopeMeter 120 Series

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

5MHz FUNCTION GENERATOR

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

DS1000E, DS1000D Series Digital Oscilloscope

MDA-550/MDA-510. Users Manual. Motor Drive Analyzer

Digital MultiMeter - Make your job efficiency User Instruction Manual

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc.

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

1507/1503. Insulation Testers. Users Manual

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Transcription:

Fluke 125 Industrial ScopeMeter Getting Started GB Dec 2006, Rev. 1, 09/2009 2006, 2009 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective companies.

Contents of the Fluke 125 Test Tool Kit S-Version (2x) (3x) Figure 1. Fluke 125 Test Tool Kit

Getting Started Introduction This Getting Started Manual provides basic information on the Fluke 125 ScopeMeter Test Tool. For complete operating instructions, refer to the Users Manual on the accompanying CD-ROM Contacting a Service Center To locate a Fluke authorized service center, visit us on the World Wide Web at: www.fluke.com or call Fluke using any of the phone numbers listed below: +1-888-993-5853 in the U.S.A and Canada +31-40-2675200 in Europe +1-425-446-5500 from other countries. Safety Information: Read First The Fluke 125 ScopeMeter Test Tool (hereafter referred to as Test Tool ) complies with: ANSI/ISA-82.02.01 EN/IEC 61010-1: 2001 600 V Measurement Category III, Pollution Degree 2 CAN/CSA-C22.2 No.61010-1-04 (including CCSA US approval) Use the Test Tool only as specified in the Users Manual. Otherwise, the protection provided by the Test Tool might be impaired. A Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and actions that may damage the Test Tool. 1

Fluke 125 Getting Started Warning To avoid electrical shock or fire: Use only the power supply, Model PM8907 (Battery Charger / Power Adapter). Before use check that the selected/indicated voltage range on the PM8907 matches the local line power voltage and frequency. For the PM8907/808 universal Battery Charger/Power Adapter use only line cords that comply with the local safety regulations. Note To accommodate connection to various line power sockets, the PM8907/808 universal Battery Charger / Power Adapter is equipped with a male plug that must be connected to a line cord appropriate for local use. Since the adapter is isolated, the line cord does not need to be equipped with a terminal for connection to protective ground. Since line cords with a protective grounding terminal are more commonly available you might consider using these anyhow. The 230V rating of the PM8907/808 is not for use in North America. A line plug adapter complying with the applicable National Requirements may be provided to alter the blade configurations for a specific country. Warning To avoid electrical shock or fire if a Test Tool input is connected to more than 42 V peak (30 Vrms) or on circuits of more than 4800 VA: Use only insulated voltage probes, test leads and adapters supplied with the Test Tool, or indicated as suitable for the Fluke 125 Test Tool. Before use, inspect voltage probes, test leads and accessories for mechanical damage and replace when damaged. Remove all probes, test leads and accessories that are not in use. Always connect the battery charger first to the ac outlet before connecting it to the Test Tool. Do not apply input voltages above the rating of the instrument. Use caution when using 1:1 test leads because the probe tip voltage will be directly transmitted to the Test Tool. Do not use exposed metal BNC or banana plug connectors. Do not insert metal objects into connectors. Always use the Test Tool only in the manner specified. 2

Getting Started Preparing for Use Max. Input Voltages Input A and B directly...600 V CAT III Input A and B via BB120...300 V CAT III Input A and B via STL120...600 V CAT III Max. Floating Voltage From any terminal to ground...600 V CAT III Voltage ratings are given as working voltage. They should be read as Vac-rms (50-60 Hz) for AC sine wave applications and as Vdc for DC applications. Measurement Category III refers to distribution level and fixed installation circuits inside a building. The isolated input connectors have no exposed metal and are fully insulated to protect against electrical shock. If Safety Features are Impaired Use of the Test Tool in a manner not specified may impair the protection provided by the equipment. Whenever it is likely that safety has been impaired, the Test Tool must be turned off and disconnected from the line power. The matter should then be referred to qualified personnel. Safety is likely to be impaired if, for example, the Test Tool fails to perform the intended measurements or shows visible damage. Preparing for Use At delivery, the installed rechargeable batteries may be empty. To reach full charge they must be charged for 7 hours with the Test Tool turned off: use only the supplied Battery Charger/Power Adapter model PM8907 before use check that the PM8907 voltage and frequency range match the local line power range connect the battery charger to the ac outlet connect the battery charger to the POWER ADAPTER input on the right-hand side of the Test Tool. Caution To prevent decrease of the battery capacity, you must charge the batteries at least once a year. Before use, inspect the test leads for mechanical damage and replace damaged test leads! 3

Fluke 125 Getting Started Powering/Resetting the Test Tool Turning power on/off: The Test Tool powers up in its last setup configuration. Resetting the Test Tool to the factory (default) settings: + Turn power off, then press and hold the Backlight key and turn on again. You should hear a double beep. Changing Backlight and Contrast To save battery power, the screen can be set to an economic brightness display when operated on the battery pack (with no power adapter connected). Note Using dimmed display lengthens maximum battery power operation time. To change the brightness and contrast: Open the LIGHT/CONTRAST button bar. Dim / Brighten the backlight. Press CONTRAST. Reading the Screen Adjust the Contrast of the display. The screen is divided into three areas that are indicated in Figure 2. The areas are: Reading area (A): Displays the numeric readings. If only input A is on, you will see the input A readings only. If input B is on you will also see the input B readings. Waveform area (B): Displays the Input A(B) waveform. The trace identifier (A) is visible on the left of the waveform. The zero icon (-) identifies the ground level of the waveform. The bottom line displays the ranges / div and the power indicator (line or battery). Note: When battery powered, the battery indicator informs you about the condition of the battery from full to empty: Press LIGHT. 4

Getting Started Making Menu Selections Menu area (C): Displays the menu that provides choices available through the blue arrow keys and the ENTER key: + Making Menu Selections Selection of a function in the menu is done as follows: A menu pops up after operation of, for instance, the MENU key. Use the arrow keys to highlight for example the SCOPE/METER mode. Press ENTER to confirm the selection. The input A measurements menu pops up. Use the arrow keys to highlight the desired measurement function. Press ENTER to confirm the selection. Figure 2. The Screen Area's 5

Fluke 125 Getting Started Input Connections and Grounding For Voltage measurements use the Shielded Test Leads on Input A (red) and/or Input B (grey). For Current measurements use a current probe on Input A and/or Input B. For Power measurements use a voltage probe on Input A and a current probe on Input B. For Temperature measurements use a 1 mv/ C or 1 mv/ F temperature probe (optional) on Input A and/or Input B. Figure 3. Grounding with Unshielded Ground Lead. For OHMΩ, CONTinuity, DIODE, and CAPacitance measurements (Meter mode) use the Red Shielded Test Lead at Input A and the Long Black Ground Lead at Input COM (Common). For low frequency measurements and high signal levels, use the Black COM (Common) Input as single ground. Figure 3 shows this. For measurements at higher frequencies up to 10 MHz or low levels, use both Shielded Test Leads with Short Ground Leads instead of using the COM Input. For measurements at frequencies above 10 MHz use the VP40 10:1 probe with a short ground lead. Bear in mind that the Short Ground Leads must be connected to the same potential! Refer to Figure 4. Figure 4. Grounding with Short Ground Leads Warning To avoid electrical shock or fire, use only one COM (common) connection, or ensure that all connections to COM are at the same potential. 6

Getting Started Displaying an Unknown Signal with Connect-and-View (Auto Set) Displaying an Unknown Signal with Connect-and-View (Auto Set) The Connect-and-View function enables hands-off operation to display complex unknown signals in SCOPE/METER mode. This function optimizes the position, range, time base, and triggering and assures a stable display on nearly all waveforms. If the signal changes, the setup will track these changes. To enable the Connect-and-View function, do the following: Connect the red test lead from red Input A to the unknown signal to be measured Perform an Auto Set. Certain details of the waveform can be made visible by manually changing amplitude, time base, waveform position, and triggering. How to do that is explained in the course of this Guide. Freezing the Screen You can freeze the screen (Waveforms and Readings) with the HOLD/RUN key. This allows you read the screen while the Test Tool has been disconnected from the Device to be checked. Freeze the screen. HOLD appears in the bottom of the reading screen. Start the measurement again. Scope/Meter Measurements Make the input connections as described on page 6. Selecting the SCOPE/METER mode Open the application mode menu. Highlight SCOPE/METER Enter the SCOPE/METER mode. 7

Fluke 125 Getting Started Scope Measurements on Input A and B Choose ac voltage (Vac) measurement for Input A: Open the A MEASUREMENTS menu. Highlight Vac. Press ENTER to confirm the selection. Open the PEAK Submenu. Highlight PEAK-PEAK. Press ENTER to confirm the selection. Now you will see a screen like in Figure 5. The A and B traces give a graphical representation of the waveforms applied to Input A and Input B. Observe that Vac (rms V ) is now the Main Reading. The former Main Reading has now moved to the smaller Secondary Reading Position. Figure 5 shows this. Then choose Peak-to-Peak Reading for Input B: Open the B MEASUREMENTS menu. Highlight ON. Turn INPUT B on. Highlight PEAK.... Figure 5. Measurements on Input A and Input B 8

Getting Started Scope/Meter Measurements Changing the Waveform Representation Changing the amplitude: Changing the Time Base: Positioning the traces: Trigger adjustments: Enlarge or reduce the waveform amplitude; there are separate keys for Input A and Input B. Increase or decrease the number of periods. Select A MOVE or B MOVE. Position the selected waveform to the desired screen position. Triggering tells the Test Tool when to begin displaying the waveform. The trigger point on the waveform is indicated by the Trigger Identifier ( ). Trigger Level and the Trigger Slope can be adjusted to your personal taste. This may help to get certain signal details within the viewing area: Enables the arrow keys for Trigger Level and Slope. Adjust the Trigger Level. Select Negative / Positive Slope. Making Cursor Measurements Cursors allow you to make precise digital measurements on live and on saved waveforms. Display the cursor key functions: Select Cursor measurement type: Measure signal height at one point of time. Measure signal height difference between two points of time and measure time difference between these two points. Measure signal height at the cursor positions and between cursor positions. Measure rise time or fall time. 9

Fluke 125 Getting Started Select the cursor to be moved. Use the blue arrow keys to move the cursors Depending on cursor measurement type: Cursor measurements on trace A or B. Automatic or manual risetime measurement on a single channel. Switch cursor measurements off. Input A and Input B Measurement Menu In the Input A and input B measurement menu you can choose from many measurement functions. Selection is done with the arrow keys and activated with F4. The function keys F1, F2, and F3 give access to submenus: INPUT... PROBE: SELECT : for selection of the correct probe type. PROBE: AC ADJUST : for adjustment of 10:1 voltage probes other than the probe supplied with Fluke 125. This is necessary for correct high frequency measurements. COUPLING: DC: DC coupled input COUPLING: AC: AC coupled input WAVEFORM: NORMAL: normal waveform display. WAVEFORM: INVERT: inverted waveform display. ZERO turns relative measurements on/off. The reading at turning on becomes the zero value, next readings are results compared to the zero value. TOUCH HOLD captures and freezes a stable measurement result. A beep indicates this. Press (TOUCH HOLD OFF) to return to normal measurement mode. 10

Getting Started Scope/Meter Measurements Trigger Options Open the application mode menu. Open the TRIGGER menu: INPUT: A, B: Triggering on the input A or input B waveform. EXT: external triggering via an optically isolated trigger probe. VIDEO on A : triggering on video signals via input A. UPDATE: FREE RUN: gives automatic screen update even if there are no triggers. ON TRIG.: only gives screen update when valid triggers occur. SINGLE: can be used to catch single events. ROLL : is useful for monitoring lower frequency waveforms. Waveform/Reading Smooth Options Open the application mode menu. Open the SMOOTH menu: WAVEFORM: ENVELOPE: envelope records all values of live waveforms. On the screen the resultant envelope is displayed. NORMAL: the mode most commonly used. SMOOTH: is used to suppress noise. READING A: B: FAST: high reading update rate NORMAL: the mode most commonly used SMOOTH: low reading update rate AUTO RANGE : >15Hz, >1Hz: selection of Auto Set on signals >15 Hz (fast response) or >1 Hz (slower). 11

Fluke 125 Getting Started Harmonics Measurements Use a voltage probe on Input A and a current probe on Input B. Selecting the Harmonics mode Open the application mode menu. Highlight HARMONICS Enter the harmonics mode. If the Input A probe setting is not V (voltage), or the input B probe setting is not (m)v/a (current), a probe menu pops up to enable you to select the required probe. Selecting the Probe Type Open the PROBE on A or the PROBE on B menu, then select the probe type. Harmonics Screen Softkey Functions The harmonics screen shows a softkey button bar like the one shown below: The harmonics screen F1 F4 key functions are: Show the voltage (VOLT) harmonics, the current (AMP) harmonics, or the power (WATT) harmonics. Select %f to display harmonics bars as a percentage of fundamental voltage. Select %r to display harmonics bars as a percentage of the total of harmonic voltages (V rms). Show the bars screen. Show the waveform screen. Set cursors ON or OFF. Cursors allow you to make precise digital measurements on the bars screen. Use < the keys to move the cursor sign > on top of a harmonic bar. The display shows the readings of the marked bar. 12

Getting Started Fieldbus Measurements Fieldbus Measurements Connect the bus to Input A, and depending on the bus type also to input B. Selecting the Fieldbus Mode and Bus Type Choose for example the Modbus, subtype IEA-232/ RS-232: Open the application mode menu. Highlight BUSHEALTH Enter the BUSHEALTH mode. Highlight Modbus. The dots... behind a bus type indicate that a submenu will follow on this selection. Open the MODBUS submenu. Highlight IEA-232/ RS-232 Press ENTER to confirm the selection. Bus Health Screen The following icons are used to indicate the bus measurement status: bus activity indicators. Bus activity indicator 1: (filled) : voltage measured (open) : no voltage measured Bus activity indicators 2 and 3: (both open) : no activity (blinking) : activity Busy, the tester is measuring/ processing data. No reading available. Result OK. Warning. Result on edge of limits Result not OK. 13

Fluke 125 Getting Started Bus Health Screen Softkey Functions The bus health screen shows a softkey button bar like the one shown below: Setting up the Limits To set up the test limits of the current bus type, do the following: Select the SETUP LIMITS menu from the bus health screen. Select the Limit Setup function, see below. Select the voltage level reading. Select the distortion type reading. Display the signal eye-pattern. Select the signal property. Select the LOW, HIGH, or WARNING level. Change the limit. Continue with other limits. Press DEFAULTS to set all limits to the default value. Accept the limits. To save and recall saved test limit sets see SAVE / PRINT Functions on page 16. 14

Getting Started Plotting Measurements over Time (TrendplotTM) Plotting Measurements over Time (Trendplot TM ) The TrendPlot function plots a graph derived from the MAIN (large) readings in the SCOPE/METER mode or in the HARMONICS mode as a function of time. Turning the Trendplot Mode On/Off Open the application mode menu. Highlight TRENDPLOT Start a Trendplot. Trendplot Screen Softkey Functions Stop the Trendplot. TREND RESTART: Start a new Trendplot. MIN MAX AVERAGE: Secondary (small) reading is the minimum, maximum, or average value since the Trendplot start. CURSOR ON OFF: Turn cursor measurements on/off (only possible if screen is frozen). See also Making Cursor Measurements on page 9. 15

Fluke 125 Getting Started User Options Menu USER OPTIONS gives submenus to configure the Test Tool to your personal taste. The function keys F1, F2, and F3 give access to submenus: BATTERY REFRESH.. : should be done about four times a year to keep the batteries in optimal condition. LANGUAGE: the language of messages can be selected in this submenu. VERSION & CAL... shows version and calibration information. SAVE / PRINT Functions Show the PRINT SCREEN, RECALL DELETE and SAVE key labels. PRINT SCREEN: The active screen is printed. See User Options Menu to select the printer type and the baud rate. RECALL DELETE : opens a menu that enables you to delete to rename or to recall a dataset. SAVE : opens a menu that enables you to save a dataset. A data set consists of the screen capture, the trace, and the test tool setup. 16