Configuration Code P01 Fixed-Element RTD Assemblies - Model 70-22 Division 1. They may be installed directly in the process without being inserted into a thermowell. The assemblies feature 316 stainless steel sheaths in various diameter sizes. They are available with or without process mountings and with aluminum or stainless steel explosion-proof connection heads. ORDER ODES Order Number: P - 2-0 2-1 2-2 R1T1 5 4 3-0 - 012-00 - 4-0 HN 94, T- Select Type and Range from back of Section gen ppro al P assembly 2-0 100 Platinum RTD Elements 0 00 5-1 TOLERANCE [1] LOW RANGE WIRE WOUND (-200 to 200) ºC SINGLE DUPLE LOW RANGE THIN FILM (-50 to 200) ºC HIGH RANGE WIRE WOUND (-200 to 600) ºC [1] Refer to RTD tolerance information in the General Information section for calculations to determine 2-1 Sheath Diameters 1 SS DIAMETERS (inches) 28 [1] 1/8 38 3/16 68 3/8 [1] Not available in duplex 2-2 Element onne tion 2 2-wire element 3 3-wire element 4 [1] 4-wire element [1] Not available in duplex or with 440 Series Transmitter 6T82- D10 93 94 1/2" NPT conduit reducer bushing I Stainless steel tag T-440 [1] (4 to 20) T-441 (4 to 20) T-442 (4 to 20) isolated transmitter T82-00 transmitter 6HN 8HN 9HP 8RNDC Field Transmitter with aluminum Field Transmitter with digital 1/2" x 1/2" NPT steel hex nipple 1" "E" length 1/2" x 1/2" NPT stainless steel hex nipple 1" "E" length 1/2" NPT stainless steel bushing (no process threads) 3/4" x 1/2" NPT stainless steel hex nipple 4-0 Sheath Mounting Fittings 00 No Fitting -0 "" Dimensions Insert three digit sheath length ("" Dimension) in inches. Communication Foundation. 368-4 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 P-1
Configuration Code P02 Fixed-Element Thermocouple Assemblies - Model 70-82 dependant on connection head type, meet P Class I, Division 1, Group A, B, C and D; DIP Class II, Division I, Groups E, F, G and Class III, Division 1. They may be installed directly in the process without being inserted into a thermowell. The assemblies feature 316 stainless steel sheaths in various diameter sizes and ungrounded isolated junctions. They are available with or without process mountings and with aluminum or stainless steel explosion-proof connection heads. CSA file #217989 ORDER S 2-0 2-1 2-2 2-3 3-0 4-0 5-0 5-1 5-2 Order Number: P - K48U - 012-00 - 8HN 93, T- Select Type and Range from back of Section Agency Approval P approved assembly 74 DIN form B aluminum explosion-proof head, Group B 75T-642B 76T82- D10 HART Field Transmitter with aluminum explosion-proof housing, Group A dual input HART Field Transmitter with digital display and explosion-proof housing, Group A 2-0 Thermocouple Types 93 Aluminum explosion-proof head, Group B SINGLE DUPLE 94 316L stainless steel explosion-proof head, Group A E EE J JJ SB 1/2" NPT conduit reducer bushing K KK I Stainless steel tag T TT T-441 isolated transmitter HART isolated T-442 2-1 Sheath Diameters transmitter DIAMETER (inches) dual input, isolated HART T82-00 2 1/8 transmitter 3 3/16 4 1/4 6 3/8 6HN 1/2" x 1/2" NPT steel hex nipple 2-2 Sheath Materials 8HN 1/2" x 1/2" NPT stainless steel hex nipple MATERIAL STANDARD AVAILABLE TYPES 9HP 1/2" NPT stainless steel bushing (no process threads) 3 Alloy 600 K 8RNDC 3/4" x 1/2" NPT stainless steel hex nipple 4 310 SS K 5 446 SS K 8 316 SS E, J, K, T 4-0 Sheath Mounting Fittings 2-3 Measuring Junction 00 No Fitting U Ungrounded 3-0 "" Dimensions Insert three digit sheath length ("" Dimension) in inches. HART is a registered trademark of the HART Communication Foundation. P-2 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 374-5
Configuration Code P03 RTD Assemblies with Thermowells - Model 70-20 Explosion-Proof RTD Assemblies with Thermowells are made for use in U.S. and Canadian hazardous areas. They are designed to extinguish 1/4" S E U ORDER S P Order Number: - 2-0 2-1 2-2 3-0 4-0 5-0 5-1 - Select Thermowell Part # - SC - from Thermowell Section R1T185L 48 3 8HN 75T-642B, 5-2 I Select Type and Range from back of Section Agency Approval P assembly 2-0 100 Platinum RTD Elements 0 003 85 C -1 TOLERANCE [1] LOW RANGE WIRE WOUND (-200 to 200) ºC SINGLE DUPLE R1T185L R1T285L R5T185L R5T285L LOW RANGE THIN FILM (-50 to 200) ºC Class A HIGH RANGE WIRE WOUND (-200 to 600) ºC R1T185H R1T285H RAT185H RAT285H Class A [1] Refer to RTD tolerance information in the 2-1 Sheath Diameters 316 SS DIAMETERS (inches) 2-2 Element Connection 3-0 Thermowell 2 2-wire 3 3-wire 4 [1] 4-wire 440 Series Transmitter Select thermowell part number from Thermowell Section. 74 HART dual input HART 1/2" NPT conduit reducer bushing Stainless steel tag T-440 [1] transmitter T-441 isolated transmitter T-442 HART isolated transmitter T82-00 transmitter STEEL FITTINGS 316SS FITTINGS 1] 1/2" x 1/2" NPT hex nipple 1" length 1/2" NPT pipe nipple 1/2" NPT union/nipple 8HN 8PN [1] 4-0 Element Options SL [1] Spring-loaded element SC 1/2" x 1/2" NPT hex nipple 1" length 1/2" NPT pipe nipple 1/2" NPT union/nipple HART is a registered trademark of the HART 375-5 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 P-3
Configuration Code P04 Thermocouple Assemblies with Thermowells - Model 70-80 Explosion-Proof Thermocouple Assemblies with Thermowells are made for use in U.S. and Canadian hazardous areas. They are designed to 316 stainless steel sheaths and ungrounded isolated junctions. They are available with aluminum or stainless steel explosion-proof connection heads. 1/4" S E CSA file #217989 U ORDER S Order Number: P - 2-1 2-2 2-3 3-0 4-0 5-0 5-1 5-2 J 48 U - - SL - 8U4 94, I Select Thermowell Part # from Thermowell Section Select Type and Range from back of Section Agency Approval P approved assembly 2-1 Thermocouple Types SINGLE DUPLE E EE J JJ K KK T TT 2-2 Sheath Diameters 316 SS DIAMETER (inches) 2-3 Measuring Junction U Ungrounded 3-0 Thermowell Select thermowell from Thermowell Section. STEEL FITTINGS 316SS FITTINGS 6HN 1/2" x 1/2" NPT hex nipple 1" length 8HN 1/2" x 1/2" NPT hex nipple 1" length 1/2" NPT pipe nipple 6PN_ 1/2" NPT union/nipple 6U_ [1] 74 75T-642B HART 76T82-D10 dual input HART 93 94 8PN 8U_ [1] 1/2" NPT pipe nipple 1/2" NPT union/nipple SB 1/2" NPT conduit reducer bushing I Stainless steel tag T-441 isolated transmitter T-442 HART isolated transmitter T82-00 transmitter 4-0 Element Options SL [1] Spring-loaded element SC Self-contained springloaded element [1] Not available with option 75T-642B HART is a registered trademark of the HART P-4 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 376-4
Configuration Code P05 Spring-Loaded RTD Assemblies - Model 70-21 Note: S ORDER S Order Number: P - R1T185L 48 3-006 - FP - 8HN 93, T- Agency Approval P 2-0 100 Platinum RTD Elements 0 003 85 C -1 TOLERANCE [1] LOW RANGE WIRE WOUND (-200 to 200) ºC SINGLE DUPLE LOW RANGE THIN FILM (-50 to 200) ºC HIGH RANGE WIRE WOUND (-200 to 600) ºC 2-1 Sheath Diameters 316 SS DIAMETERS (inches) 2-2 Element Connection 2 3 4 [1] 74 316 STAINLESS STEEL FITTINGS 8HN 8PU4 [1] 4-0 Element Options FP 3-0 "S" Dimensions Insert three digit sheath length ("S" Dimension) in inches Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 P-5
Configuration Code P06 Hazardous Location Explosion-Proof-Approved, Spring-Loaded Thermocouple Assemblies - Model 70-81 Note: The "S" S ORDER S Order Number: 2-1 2-2 2-3 3-0 4-0 5-0 5-1 P - - - - J 48 U 012 FP 8HN 94, T- 5-2 Agency Approval P 2-1 Thermocouple Types J JJ K KK T TT 2-2 Sheath Diameters 316 SS DIAMETER (inches) 74 75T-642D 76T82-D10 I T-441 T-442 T82-00 2-3 Measuring Junction U Ungrounded 3-0 "S" Dimensions Insert three digit sheath length ("S" Dimension) in inches 316 STAINLESS STEEL FITTINGS 8HN 8PU4 [1] 4-0 Element Options FP P-6 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 378-4
Temperature Transmitters for Hazardous Location Explosion-Proof Sensor Assemblies ORDER S Order Number: 75T-642B 1-1 1-2 1-3 1-4 - D - 3 85 U - 1-5 1-6 C S(0-200) Transmitter Type 440 [1] 441 442 75T-642B 75T-642D [1] [2] 1-1 Options (For 642 Series only) T D 1-6 Unit of Measure F 1-5 Range S 1-4 Failure Mode U D 1-3 Sensor Type J K T N E 1-2 Input Type 00 [1] 1 2 3 4 395-3 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 P-7
Complete Transmitter Connection Head and Transmitter Selection Guide Connection Heads 74 75 93 94 Temperature Transmitters DIN form B Aluminum Explosion-Proof Head, Group A Aluminum Explosion-Proof Field Transmitter Housing, Group A Aluminum Explosion-Proof Head, Group B 316L Stainless Steel Explosion- Proof Head, Group A T-440 Pt100 RTD Only transmitter, analog output T-441 transmitter, isolated, (4 to 20) ma analog output T-442 transmitter, isolated, HART protocol, analog output T82-00 dual input, isolated HART transmitter T-642 isolated, HART protocol, analog output T-642 w/ display isolated, HART protocol, analog output with digital display 76T82-D10 dual input HART Field Transmitter with digital display and explosionproof housing, Group A Unit includes housing and transmitter. HART is a registered trademark of the HART Communication Foundation. P-8 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 380-4
Overview of NEC Hazardous Location Classifications and Methods of Protection Classes Class I Groups s Divisions 1 2 Class II s Class III Methods of Protection Explosionproof (P) Class I, Division 1, 2 Dust-Ignitionproof (DIP) Class II, Division 1, 2 Intrinsically Safe (IS) Class I, Division 1, 2 Class II, Division 1, 2 Class III, Division 1, 2 Nonincendive (NI) Class I, Division 2 Class II, Division 2 Class III, Division 1, 2 The NEC 2005 Handbook, NFPA 70: National Electrical Code International Electrical Code Series 439-2 Distributed By: M&M Control Service, Inc. www.mmcontrol.com/pyromation.php 800-876-0036 847-356-0566 P-9