Capacitor Switching Contactors

Similar documents
Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

General 2 Approvals 3 Technical Information 5 Mounting Information 6

General Catalogue. Quality made in D946E182

Micro-Contactors LAM ONLINE SHOPPING! Get Ready. Get Schrack. In the office and on the go with the Live Phone App.

Output of three-phase motors at 50 Hz and 400 V

Controls Contactors and Contactor Assemblies Special Applications

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Type: DILEM 10 G(24VDC) Article No.:

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Characteristics 5 TeSys k contactors and reversing contactors

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

3 - Protection components Circuit-breakers

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-SDS.22

Contactors and Contactor Assemblies

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-E 24/2.5

Power supply CP-T 24/20.0 Primary switch mode power supply

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Power supply CP-E 24/20.0

Power supply CP-T 48/5.0 Primary switch mode power supply

Description Basic devices with positive operation contacts

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

Installation / Monitoring Technique

SIRIUS/SIKOSTART Soft Starters For Standard Applications

Page 13-2 Page Page 13-7

XT IEC Power Control Miniature Controls

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

NS..S contactor relays - with spring terminals AC operated

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Power supply CP-T 24/10.0 Primary switch mode power supply

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Power supply CP-T 24/40.0 Primary switch mode power supply

Control module CP-A CM

MINI-PS AC/24DC/1.3

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Solid-State Soft Starters

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Power supply CP-E 24/0.75

Power supply CP-D 24/4.2 Primary switch mode power supply

E-STOP relays, safety gate monitors

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

IMPULSE SWITCH, REMOTE SWITCH

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

190S A N D 2 C A16 C TE

Type: DILM40(RDC24) Article No.:

Electronic timer CT-SDD.22

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)

Three-phase monitoring relay

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Power supply CP-E 24/2.5

METRAClip87 and 88 Clamp Multimeters

Power supply CP-D 12/2.1

Thermistor motor protection relays

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Switching Devices Contactors and Contactor Assemblies for Switching Motors

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Three-phase monitoring relays CM-PFE and CM-PFE.2

Safety switches with slotted hole lever

QUINT-PS-24DC/24DC/10

B 80.en. Single pole cam contactors for DC and AC applications C160, C162 Series. Connect - Contact - Control max. ED: 100% U 14,4V.

PKZ 2 Manual Motor Protectors Technical Data

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

(1,5 modules per pole)

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

QUINT-PS/ 3AC/24DC/10

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Three-phase monitoring relay CM-PFS

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

CI-tronic Soft start motor controller

For non-electrical quantities

Electronic timer CT-TGD.22

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Transcription:

Capacitor Switching D385E51

Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R.. up to 32A M4-63R... up to 63A M4-100R..up to 100A Catalogue D677E.. Catalogue D795E.. Switches On- Off Switches Changeover Switches Motor Switches Step Switches Main Switches Modular Switches Key Operated Switches Main Switches Emergency Off Main Switches On-Off-Switches Add-On-Module Catalogue D371E.. Catalogue D656E.. Capacitor Switching for reactive and non reactive capacitor banks Catalogue D385E.. Manual Motorstarter MU25A up to 25A Auxiliary Contact Blocks Trip Alarm Auxiliary Switches Busbar Connectors Enclosure Catalogue D509E.. Push Buttons Modular- Push Buttons Emergency Stop Key Operated Rotary Switches Rotary Knobs Illuminated Push Buttons Assembled Stations Modular Accessories Emergency Off Switches Main Switches On-Off Switches Control Switches Catalogue D580E.. Catalogue D681E.. Low Voltage- Control Gear D.O.L. Starters Overload Relays Manual Motor Starters Main Switches Circuit Breakers Cam Switches Push Buttons DC-Switchgear for Photovoltaic Main Switches On-Off-Switches for DC-Switching Catalogue D651E.. Catalogue D911E.. Benedict GmbH Lieblgasse 7, A-1220 Wien, Tel.:+43-1-251 51-0, Fax.:+43-1-251 51-89

Page Capacitor Switching - 2 3 Auxiliary Contact Blocks 3 Technical Data 4, 5, 6 Dimensions 7 Typical Circuit Diagram 8 Contactor operation 8 Function 9,10,11 D385E 1

Capacitor Switching for use with reactive or non-reactive capacitor banks Rated Operational Power at 50/60Hz Aux. Type Ambient Temperature Contacts 50 C 60 C Built-in Add. Coil voltage 1) 380V 415V 660V 380V 415V 660V 230 220-240V 50Hz 400V 440V 690V 400V 440V 690V Pack Weight kvar kvar kvar kvar kvar kvar NO NC pcs. pcs. kg/pc. 0-12,5 0-13 0-20 0-12,5 0-13 0-20 1-1 K3-18NK10... 1 0,34 0-12,5 0-13 0-20 0-12,5 0-13 0-20 - 1 1 K3-18NK01... 1 0,34 10-20 10,5-22 17-33 10-20 10,5-22 17-33 - - 3 K3-24K00... 1 0,62 10-25 10,5-27 17-41 10-25 10,5-27 17-41 - - 3 K3-32K00... 1 0,62 20-33,3 23-36 36-55 20-33,3 23-36 36-55 - - 3 K3-50K00... 1 1,0 20-50 23-53 36-82 20-50 23-53 36-82 - - 3 K3-62K00... 1 1,0 20-75 23-75 4) 36-120 4) 20-60 23-64 36-100 - - 3 K3-74K00... 1 1,0 33-80 36-82 57-120 33-75 36-77 57-120 - - 6 5) K3-90K00... / VS 7) 1 2,3 33-100 6) 36-103 6) 57-148 6) 33-90 6) 36-93 6) 57-148 6) - - 6 5) K3-115K00... / VS 7) 1 2,3 Specification: K3-..K are suitable for switching low-inductive and low loss capacitors in capacitor banks (IEC70 and 831, VDE 0560) without and with reactors. Capacitor switching contactors are fitted with early make contacts and damping resistors, to reduce the value of make current <70 x I e. Operating Conditions: Capacitor switching contactors are protected against contact welding for a prospective making current of 200 x I e. Mounting instructions: In the area of capacitor switching contactors, difficulty inflammable and self-extinguishing materials shall be used only, because abnormal temperatures within the area of the resistor spirals cannot be excluded. Technical Data acc. to IEC 947-4-1, IEC 947-5-1, EN 60947-4-1, EN 60947-5-1, VDE 0660 Type K3-18NK K3-24K K3-32K K3-50K K3-62K K3-74K K3-90K K3-115K Max. frequency of operations z 1/h 120 120 120 120 120 80 80 80 Contact life non reactive capacitor banks S x 10 3 250 150 150 150 150 120 120 120 reactive capacitor banks S x 10 3 400 300 300 300 300 200 200 200 Rated operational current I e at 50 C A 0-18 14-28 14-36 30-48 30-72 30-108 50-115 50-144 AC6b at 60 C A 0-18 14-28 14-36 30-48 30-72 30-87 50-108 50-130 Rated operational current I th at 50 C A 32 45 60 100 110 120 155 190 AC1 at 60 C A 32 40 55 90 100 110 145 170 Overload factor at 50 C % 78 60 67 108 53 11 35 32 acc. to EN 61921: 30% min. at 60 C % 78 43 53 88 39 26 34 31 Fuses gl (gg) from / to A 35 / 63 50 / 80 63 / 100 80 / 160 125 / 160 160/200 160/200 160/250 1) Coil voltage range and non-standard coil voltages see page 3 2) 1 HN.. or HA.. snap-on 3) 2HB.. for side mounting and 1 HN.. or HA.. snap-on 4) Consider the max. thermal current of the contactor K3-74A: I th 130A 5) 2 HB.. on the left or right side and 4 HN.. or HA.. snap-on 6) Consider the min. cross-section of conductor at max. load 7) Type 230 for AC- and DC-operating 220-240V 50/60Hz and 220V DC ( with integrated coil suppressor ) Type 230VS for AC-operating 220-240V 50Hz ( with integrated coil suppressor ) 2 D385E

for use with reactive capacitor banks Rated Operational Power at 50/60Hz Aux. Contacts Type Ambient Temperature Built-in Add. 50 C 60 C Coil Voltage 380V 415V 660V 380V 415V 660V 230 220-240V 50Hz 400V 440V 690V 400V 440V 690V Pack Weight kvar kvar kvar kvar kvar kvar NO NC pcs. pcs. kg/pc. 5 5,5 8 5 5,5 8 1-4 K3-10ND10... 1 0,23 9 9,5 15 9 9,5 15 1-4 K3-14ND10... 1 0,23 12,5 13 20 12,5 13 20 1-4 K3-18ND10... 1 0,23 13 14 22 13 14 22 1-4 K3-22ND10... 1 0,23 20 22 33 20 22 33 - - 6 K3-24A00... 1 0,48 25 27 41 25 27 41 - - 6 K3-32A00... 1 0,48 27,5 30 48 27,5 30 48 - - 6 K3-40A00... 1 0,48 33,3 36 55 33,3 36 55 - - 6 K3-50A00... 1 0,85 50 53 82 50 53 82 - - 6 K3-62A00... 1 0,85 75 75 100 60 64 100 - - 6 K3-74A00... 1 0,85 80 82 120 75 77 120 - - 9 K3-90A00... / VS 7) 1 2,2 100 5) 103 5) 148 5) 90 5) 93 5) 148 5) - - 9 K3-115A00... / VS 7) 1 2,2 Auxiliary Contact Blocks Rated Operational Current Contacts Type Pack Weight AC15 AC1 230V 400V 690V A A A For NO NC pcs. kg/pc. 6 4 25 K3-10.. to K3-115.. - 1 HA01 10 0,03 3 2 10 K3-24.. to K3-115.. 1 1 HB11 10 0,02 3 2 10 for side mounting - 2 HB02 10 0,02 3 2 10 K3-10.. to K3-115.. 1 - HN10 10 0,02 3 2 10 K3-10.. to K3-115.. - 1 HN01 10 0,02 Coil Voltages and Voltage Ranges for capacitor switching contactors for contactor-type K3-10.. to K3-74.. Suffix Voltage Marking Rated Control Voltage U s to contactor at the coil range type for for for 50Hz for 60Hz e.g. 50Hz 60Hz min. max. min. max. K3-18NK10 24 V V V V V V 24 24 24 22 24 24 27 48 48 48 44 48 48 52 110 110 110-120 100 110 110 122 180 180-210 200-240 180 210 200 240 230 220-240 230-264 220 240 230 264 400 380-415 400-440 380 415 400 460 for contactor-type K3-90.. to K3-115.. Suffix Voltage Marking Rated Control Voltage U s to contactor at the coil range type for for for 50Hz for 60Hz z.b.: 50/60Hz DC min. max. min. max. K3-90K00 230 V V V V V V 24 24 24 22 24 22 24 48 48 48 44 48 44 48 110 110-120 110 110 120 110 120 200 200-220 200 200 220 200 220 230 220-240 220 220 240 220 240 400 380-415 - 380 415 380 415 1) 4 HN.. or HA.. snap-on 4) 2 HB.. on the left or right side and 7 HN.. or HA.. snap-on 2) 2 HB.. on the left or right side and 4 HN.. or HA.. snap-on 5) Consider the min. cross-section of conductor at max. load 3) Consider the max. thermal current: I th 130A 7) Type 230 for AC- and DC-operating 220-240V 50/60Hz and 220V DC ( with integrated coil suppressor ) Type 230VS for AC-operating 220-240V 50Hz ( with integrated coil suppressor ) D385E 3

Capacitor Switching Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Main Contacts Type K3-18NK K3-24K K3-32K K3-50K K3-62K K3-74K K3-90K K3-115K Utilization category AC6b Switching of non-reaktive and reactiv 3-phase capacitor banks Ambient temperature 50 C Rated operational current I e 690V A 0-18 14-28 14-36 30-48 30-72 30-108 1) 50-115 50-144 2) Rated operational power 220-240V kvar 0-7 5-11 5-14 12-20 12-28 12-33 20-45 20-55 2) 380-400V kvar 0-12,5 10-20 10-25 20-33,3 20-50 20-75 1) 33-80 33-100 2) 415-440V kvar 0-13 10,5-22 10,5-27 23-36 23-53 23-75 1) 36-82 36-103 2) 500V kvar 0-15 12-25 12-30 26-40 26-60 26-75 43-100 43-120 2) 525V kvar 0-15 12-25 12-32 26-43 26-64 26-80 45-105 45-125 2) 660-690V kvar 0-20 17-33 17-41 36-55 36-82 36-120 57-120 57-148 2) 750V kvar - - - - - - 65-130 65-165 2) 1000V kvar - - - - - - 85-150 85-180 2) Ambient temperature 60 C Rated operational current I e 690V A 0-18 14-28 14-36 30-48 30-72 30-87 50-108 50-130 2) Rated operational power 220-240V kvar 0-7 5-11 5-14 12-20 12-28 12-30 20-40 20-50 2) 380-400V kvar 0-12,5 10-20 10-25 20-33,3 20-50 20-60 33-75 33-90 2) 415-440V kvar 0-13 10,5-22 10,5-27 23-36 23-53 23-64 36-77 36-93 2) 500V kvar 0-15 12-25 12-30 26-40 26-60 26-70 43-90 43-110 2) 525V kvar 0-15 12-25 12-32 26-43 26-64 26-75 45-95 45-115 2) 660-690V kvar 0-20 17-33 17-41 36-55 36-82 36-100 57-120 57-148 2) 750V kvar - - - - - - 65-130 65-165 2) 1000V kvar - - - - - - 85-150 85-180 2) Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Main Contacts Type K3-10 K3-14 K3-18 K3-22 K3-24 K3-32 K3-40 K3-50 K3-62 K3-74 K3-90 K3-115 Utilization category AC6b Switching of reactive capacitor banks Ambient temperature 50 C Rated operational current I e 690V A 8 13 18 20 28 36 42 48 72 108 1) 115 144 2) Rated operational power 220-240V kvar 2,9 5 7 7,5 11 14 16 20 28 33 45 55 2) 380-400V kvar 5 9 12,5 13 20 25 27,5 33,3 50 75 1) 80 100 2) 415-440V kvar 5,5 9,5 13 14 22 27 30 36 53 75 1) 82 103 2) 500V kvar 6 11 15 17 25 30 36 40 60 75 100 125 2) 525V kvar 6 11 15 17 25 32 36 43 64 80 105 125 2) 660-690V kvar 8 15 20 22 33 41 48 55 82 120 120 148 2) 750V kvar - - - - - - - - - - 130 165 2) 1000V kvar - - - - - - - - - - 150 180 2) Ambient temperature 60 C Rated operational current I e 690V A 8 13 18 20 28 36 42 48 72 87 108 130 2) Rated operational power 220-240V kvar 2,9 5 7 7,5 11 14 16 20 28 30 40 50 2) 380-400V kvar 5 9 12,5 13 20 25 27,5 33,3 50 60 75 90 2) 415-440V kvar 5,5 9,5 13 14 22 27 30 36 53 64 77 93 2) 500V kvar 6 11 15 17 25 30 36 40 60 70 90 110 2) 525V kvar 6 11 15 17 25 32 36 43 64 75 95 115 2) 660-690V kvar 8 15 20 22 33 41 48 55 82 100 120 148 2) 750V kvar - - - - - - - - - - 130 165 2) 1000V kvar - - - - - - - - - - 150 180 2) 1) Consider the max. thermal current: I th 130A 2) Consider the min. cross-section of conductor at max. load 4 D385E

Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Main Contacts Type K3-10 K3-14 K3-18 K3-22 K3-24 K3-32 K3-40 K3-50 K3-62 K3-74 K3-90 K3-115 Rated insulation voltage U 1) i V AC 690 690 690 690 690 690 690 690 690 690 1000 1000 Rated operational current I e (=I th ) A 25 25 32 32 50 65 80 110 120 130 160 200 at 40 C, open 690V Maximum ambient temperature Operation open C -40 to +60 (+90) 2) enclosed C -40 to +40 Storage C -50 to +90 Short circuit protection Coordination-type "1" acc. to IEC 947-4-1 Contact welding without hazard of persons fuse size from gl (gg) A 35 35 35 35 50 63 63 80 125 160 160 160 to gl (gg) A 63 63 63 63 80 100 100 160 160 200 200 250 Cable cross-sections for contactors without thermal overload relay 1 cable per clamp main connector solid or stranded mm² 0,75-6 1,5-25 4-50 0,5-95 10-120 flexible mm² 1-4 2,5-16 10-35 0,5-70 25-95 flexible with multicore cable end mm² 0,75-4 1,5-16 6-35 0,5-70 10-95 2 cables per clamp top below solid or stranded mm² 6+(1-6) / 4+(0,75-4) 16+(2,5-6) / 10+(4-10) 50+4 / 35+6 / 25+(6-16) 0,5-95 + 10-120 2,5+(0,75-2,5) / 1,5+(0,75-1,5) 6+(4-6) / 4+(2,5-4) 16+(6-16) / 10+(6-16) flexible mm² 6+(1,5-6) / 4+(1-4) 16+(2,5-6) / 10+(4-10) 50+(4-10) / 35+(4-16) 0,5-70 + 10-95 2,5+(0,75-2,5) / 1,5+(0,75-1,5) 6+(4-6) / 4+(2,5-4) 25+(4-25) / 16+(4-16) Cables per clamp 2 2 2 1+1 Screw / screw driver M3,5 / Pz2 M5 / Pz2 M6 / Pz3 M8 / 4mm-inbus Tightening torque Nm/lb.inch 0,8-1,4 / 7-12 2,5-3 / 22-26 3,5-4,5 / 31-40 4-6,5 / 35-57 for main connector solid AWG 18-10 16-10 12-10 - flexible AWG 18-10 14-4 10-0 - Cables per clamp 2 1 1 - top below solid AWG 10+(16-10) / 12+(18-12) 10+(16-10) / 12+(18-12) 10+(12-10) / 12+12 18-10 - 14+(18-14) / 16+(18-16) 14+(18-14) / 16+(18-16) flexible AWG 10+(14-10) / 12+(18-12) 4+(18-12) / 6+(18-8) 1+(12-10) / 2+(8-12) 18-3/0 8-4/0 14+(18-14) / 16+(18-16) 8+(18-8) / 10+(18-12) 3+(12-8) / 4+(10-6) Cables per clamp 2 2 2 1+1 Mechanical life AC operated S x 10 6 10 10 10 5 DC operated S x 10 6 10 10 10 5 Short time current 10s-current A 96 120 144 176 184 240 296 360 504 592 680 880 Power loss per pole at I e /AC3 400V W 0,21 0,35 0,5 0,75 0,7 1,3 2 2,2 3,9 5,5 4,3 6,0 Auxiliary Contacts Rated insulation voltage U i V~ 690 - - - Thermal rated current I th to 690V Ambient temperature 40 C A 16 - - - 60 C A 12 - - - Utilization category AC15 220-240V A 12 - - - Rated operational 380-415V A 4 - - - current I e 440V A 4 - - - 500V A 3 - - - 660-690V A 1 - - - Utilization category DC13 60V A 8 - - - Rated operational 110V A 1 - - - current I e 220V A 0,1 - - - Short circuit protection short-circuit current 1kA, contact welding not accepted max. fuse size gl (gg) A 25 - - - 1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request. 2) With reduced control voltage range 0,9 up to 1,0 x U s and with reduced rated current I e /AC1according to I e /AC3 D385E 5

Data according to IEC 947-4-1, EN 60947-4-1, VDE 0660 Type K3-10 K3-14 K3-18 K3-22 K3-24 K3-32 K3-40 K3-50 K3-62 K3-74 K3-90 K3-115 Control Circuit Power consumption of coils AC operated inrush VA 33-45 90-115 140-165 190-280 sealed VA 7-10 9-13 13-18 2,5-5 W 2,6-3 2,7-4 5,4-7 2,5-5 DC operated inrush W 75 140 200 190-280 sealed W 2 2 6 2,5-5 Operation range of coils in multiples of control voltage U s AC operated 0,85-1,1 0,85-1,1 0,85-1,1 0,85-1,1 DC operated 0,8-1,1 0,8-1,1 0,8-1,1 0,8-1,1 Switching time at control voltage U s ±10% 1) 2) AC operated make time ms 8-16 10-25 12-28 20-35 release time ms 5-13 8-15 8-15 35-50 arc duration ms 10-15 10-15 10-15 10-15 DC operated make time ms 8-12 10-20 12-23 20-35 release time ms 8-13 10-15 10-18 35-50 arc duration ms 10-15 10-15 10-15 10-15 Cable cross-section Auxiliary connector solid mm² 0,75-6 - - - flexible mm² 1-4 - - - flexible with multicore cable end mm² 0,75-4 - - - Magnet coil solid mm² 0,75-2,5 0,75-2,5 0,75-2,5 0,75-2,5 flexible mm² 0,5-2,5 0,5-2,5 0,5-2,5 0,5-2,5 flexible with multicore cable end mm² 0,5-1,5 0,5-1,5 0,5-1,5 0,5-1,5 Clamps per pole 2 2 2 2 Screw / screw driver M3,5 / Pz2 M3,5 / Pz2 M3,5 / Pz2 M3,5 / Pz2 Tightening torque Nm/lb.inch 0,8-1,4 / 7-12 0,8-1,4 / 7-12 0,8-1,4 / 7-12 0,8-1,4 / 7-12 Auxiliary connector solid AWG 18-10- - - - flexible AWG 18-10 - - - Magnet coil solid AWG 14-12 14-12 14-12 14-12 flexible AWG 18-12 18-12 18-12 18-12 Clamps per pole 2 2 2 2 Capacitor Switching for North America Data according to UL508 Main Contacts (culus) Type K3-18NK K3-24K K3-32K K3-50K K3-62K K3-74K K3-90K K3-115K Rated operational power of 3-phase capacitor banks 110-120V kvar 0-3,5 3-5,5 3-7 6,5-10 6,5-15 6,5-18 3) 10-24 10-28 4) at 60Hz (3ph) 200V kvar 0-6 4,5-10 4,5-12,5 10-16,7 10-25 10-32 3) 17-40 17-46 4) 220-240V kvar 0-7 5,5-11 5,5-15 12,5-20 12,5-30 12,5-36 3) 20-47 20-56 4) 440-480V kvar 0-15 11,5-25 11,5-30 25-40 25-60 25-72 3) 40-95 40-114 4) 550-600V kvar 0-18 14,5-30 14,5-35 31-50 31-75 31-90 3) 50-120 50-143 4) Fuse Class RK5 / Short-circuit current A/kA 50/5 90/5 125/5 200/5 250/5 300/5 300/10 300/10 Fuse Class T / Short-circuit current A/kA 70/100 110/100 150/100 175/100 175/100 175/100 300/100 5) 300/100 5) Rated voltage V 600 600 600 600 600 600 600 600 Auxiliary Contacts (culus) A600 - - - - - - - 1) Total breaking time = release time + arc duration 2) Values for delay of the release time of the make contact and the make time of the break contact will be increased, if magnet coils are protected against voltage peaks (varistor, RC-unit, diode-unit) 3) Consider the max. thermal current of the contactor K3-74A: I th 130A 4) Consider the min. cross-section of conductor at max. load 5) Class T and Class RK1 6 D385E

Dimensions Capacitor switching contactors, AC operated K3-18NK.. AC-operated K3-10ND10 K3-14ND10 K3-18ND10 K3-22ND10 K3-24K00 K3-32K00 K3-24A00 K3-32A00 K3-40A00 K3-50K00 K3-62K00 K3-74K00 K3-50A00 K3-62A00 K3-74A00 K3-90K00 K3-115K00 K3-90A00 K3-115A00 D385E 7

Typical Circuit Diagram of Capacitor Switching Typical Circuit Diagram Wiring Diagram for Quick Discharge Resistors Make sure that the current of the discharge resistors is not higher than the rated current (AC1) of the auxiliary contacts Contactor operation at direct switching of capacitors Theoretic view of function Make In case of the pre-contacts during make, the current peaks are attenuate by resistor wires. These current peaks would weld the main-contacts of contactor and they are also not good for the capacitors. The total resistance of the resistor wires is mostly ohmic, the inductive one can be ignored. The looking like a coil is only a case of construction. The single controlled pre-contacts are increasing the safety of operating, in opposite of contamination during operation. Operation: During operation the resistor wires are not getting warmer, because they are not in the circuit. Break: Important: these contactors can be used for both installations, because the pre-contacts have no function during break, thus means that the peaks of the break-over voltage (power) of the chokes can t make any damage. 8 D385E

Description Function diagram main-contacts pre-contacts 5-10 ms Practical function - oscillogram make with pre-contacts (B&J\Oszi11) make with pre-contacts (B&J\Oszi10) K3-18NK 12.5kVAr (18A / 400V) K3-18NK 12.5kVAr (18A / 400V) vertical: 250A / div horizontal: 1ms / div vertical: 100A / div horizontal: 1ms / div Description: The difference of the diagrams is the current scale only. First current peak due to make of pre-contacts. Second current peak due to building-up the main-circuit with noteable lower amplitude as the first and not so steep, that means lower frequency. D385E 9

Description make with pre-contacts (B&J\Oszi13) make without pre-contacts (B&J\Oszi12) K3-18NK 12.5kVAr (18A / 400V) K3-18ND 12.5kVAr (18A / 400V) vertical: 250A / div horizontal: 0.5ms / div vertical: 250A / div horizontal: 0.5ms / div The right picture shows a make current peak without pre-contacts with about 1200A with high power in opposite to 280A with low power (power = integrated area). Of course, the contactors endure a few switches without pre-contacts. 10 D385E

Switching of capacitor banks at different conditions make without pre-contacts (B&J\Oszi16) without chokes make without pre-contacts (B&J\Oszi15) with chokes K3-62A 50kVAr (72A / 690V) K3-62A 50kVAr (72A / 690V) vertical: 2000A / div horizontal: 0.625ms / div vertical: 200A / div horizontal: 10ms / div make with pre-contacts (B&J\Oszi14) with chokes K3-62K 50kVAr (72A / 690V) vertical: 200A / div horizontal: 10ms / div The make current peak without pre-contacts and without chokes is higher than 4000A. This peak can be reduced by the influence of chokes to approx. 500A. In the last case we see the influce of chokes and precontacts of the "capacitor contactor". The peak is reduced to approx. 200A. Also the sinus-weave is very clear by the influence of chokes because you have reduced harmonic frequences. D385E 11

Notice: 12 D385E

D385E151 Lieblgasse 7, A-1220 Vienna Phone: +43 1 251 51-0 Fax: +43 1 251 51-89 e-mail: sales@benedict.at www.benedict.at quick access to www.benedict.at