WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW

Similar documents
INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

Installation Guide for Architectural Wood Hinged Windows

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

Installation Guide for Andersen Architectural Clad Hinged Windows

Installation Guide for Andersen 200 Series Tilt-Wash Picture, Transom and Circle Top Windows

Installation Guide for Andersen Frenchwood Patio Door Sidelights and Transoms

Installation Guide for Andersen Architectural Clad Awning Windows

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

Steel Reinforced Joining Guide (Horizontal / Vertical)

Installation Guide. for Andersen 400 Series Tilt-Wash Picture Windows with Stormwatch Protection (High-Performance Impact Resistant Glass)

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Guide for Andersen 400 Series Tilt-Wash Transom Windows with Stormwatch Protection (PG Upgrade) Manufactured After 2006

Installation Guide for Andersen Architectural Clad Inswing Entry and Patio Doors

Installation Guide for Andersen 400 Series Gliding Windows

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door

Tools required by installer: Materials required by installer:

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

Follow instructions from foam, sealant and flashing manufacturer regarding material application and compatibility with this product.

Read guide from beginning to end before starting installation. Read and follow all warnings and cautions during unit installation.

for Andersen Frenchwood Hinged and Outswing Patio Doors, Sidelights, and Transoms

Read guide from beginning to end before starting installation. Read and follow all warnings and cautions during unit installation.

Integrity Polygon and Round Top Installation and Finishing Instructions

1-Way Vertical Joining (Pages 2-22) 1-Way Horizontal Joining (Pages 23-44)

3/4" LVL Reinforced Joining Guide

Non-Reinforced Joining Guide (Horizontal/Vertical)

VISTALUXE CASEMENT, AWNING, & PICTURE WINDOW

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines for all Quaker products with nail fins New Construction nail fin installation with a Zip sheathing system.

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

Sash Replacement Guide for Andersen Impact Resistant Casement Windows

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

INSTALLATION INSTRUCTIONS FOR TEUTONIC ENTRANCE DOOR RECOMMENDATIONS FOR COMMON INSTALLATION OF ENTRANCE DOORS.

Panel Assembly and Installation

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window

Installation Guide for E-Series/Eagle Ascent 2 or 4 Panel Gliding (Sliding) Patio Doors

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS.

DOOR INSTALLATION GUIDE WOOD FRAMING New Construction

Window with Nail fin (New construction)

Installation of Fiberglass Windows

Vinyl Windows and Doors Manufactured by Pella Corporation

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

Eagle clad double-hung window installation instructions

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR CLAD CASEMENT & AWNING WINDOW VENTANA DE DOS HOJAS CON REVESTIMIENTO

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows

STACKING MULTI-SLIDE DOOR SYSTEM

Fixed Upper Sash Replacement Guide for Andersen 400 Series Woodwright Springline Single-Hung Windows

Installation Instructions for E-Series 2 or 4-Panel Gliding and French Gliding Patio Doors

Flashing Materials. Rough Opening Preparation

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS

Sash Replacement Guide for Andersen 400 Series Tilt-Wash Transom Windows

INSTALLATION INSTRUCTIONS FOR FORGENT SLIDING PATIO DOORS RECOMMENDATIONS FOR COMMON INSTALLATION OF SLIDING PATIO DOORS.

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Assembled Patio Door Installation Guide 2-Panel Patio Door with Non-Welded Frame

INSTALLATION INSTRUCTION FOR WOOD DOUBLE-HUNG AND CASEMENT WINDOWS USING WOOD BRICKMOULD OR FLAT CASING

window installation Guide wood FRaMinG New Construction

WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

Sun Windows General Information New Construction Hinged Door Installation Instructions

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO

All Window Installation Instruction

WINDOW REPLACEMENT INSTRUCTIONS FOR SINGLE-HUNG, DOUBLE-HUNG, CASEMENT, AWNING INTO EXISTING CASEMENT FRAME USING FRAME SCREWS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

HR175 Sash Replacement Kit Installation Instructions

Norwood Windows Permaglass Fiberglass Products Installation Instruction

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

Vinyl Windows and Doors

INSTALLATION INSTRUCTIONS for Custom and Premium Pocket Windows (JII022) IMPORTANT INFORMATION AND GLOSSARY SAFETY AND HANDLING

Reinforced 10 Bow Window Assembly and Installation Guide for Andersen 400 Series Transom Joined Casement Windows

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

Vinyl Windows and Doors

TARGA 7200 HORIZONTAL ROLLER INSTALLATION INSTRUCTIONS NOTE: Read instructions completely before attempting any installation.

I n s t a l l a t i o n I n s t r u c t i o n s

SERIES 360. Single Hung Windows. NOTE: Read instructions completely before attempting any installation.

INSTALLATION INSTRUCTION SINGLE PANEL, SINGLE PANEL WITH SIDELIGHT COMBINATION AND 20 MINUTE FIRE RATED WOOD FRAME ENTRY DOOR

Picture Window Rough Opening Installation with Sheathing Intact with Brickmould Tools: (Not supplied by manufacturer) Fig. 0-1

Vinyl Windows and Doors Manufactured by VPI Quality Windows

Sliding Glass Door Assembly and Installation Guide

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION FOR CLAD BOW WINDOWS WITHOUT HEAD AND SEAT BOARD

HERITAGE CASEMENT BOW & BAY WINDOW

POCKETING MULTI-SLIDE DOOR SYSTEM

VINYL WINDOWS (new construction or replacement) page 2. VINYL PATIO DOORS pages WOOD CLAD WINDOWS (new construction).page 5 WOOD CLAD WINDOWS

3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS

Vinyl Windows and Doors

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

IMPORTANT: Please read this supplement and your unit installation instructions before you begin.

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

PELLA INSTALLATION INSTRUCTIONS - ADVANCED PERFORMANCE Nail Fin, Nail Fin with J-Channel and EnduraClad Exterior Trim with Nail Fin Windows

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT.

GENERAL INSTALLATION GUIDELINES

Transcription:

WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW INSTALLATION GUIDE READ SPECIFIC INSTALLATION INSTRUCTIONS COMPLETELY BEFORE STARTING ANY INSTALLATION Failure to install and maintain our product according to these instructions will VOID any warranty, written or implied. The installer is responsible for consulting the contractor, structural engineer, architect, or consumer, for proper installation according to local codes and/or ordinances. Every assembly and installation is different from Parrett Windows & Doors. Parrett strongly recommends consultation with a Parrett supplier or an experienced contractor, architect, or structural engineer prior to the assembly and installation of any Parrett product. PARRETT HAS NO RESPONSIBILITY IN REGARD TO POST MANUFACTURED ASSEMBLY AND INSTALLATION OF PARRETT PRODUCTS. CAUTION Factory applied exterior Brickmould and casing DO NOT take the place of standard window flashing. Each unit must be properly flashed and sealed with silicone for protection against water and air infiltration. TO INSTALLER Using ladders and/or scaffolding and working at elevated levels can be very dangerous. Follow the manufacturer s instructions for all equipment used in order for safe operation. Please use extreme caution when working around window or door openings. Falling from opening may result in injury or death. Improper use of hand/power tools could result in injury and/or product damage. Again, follow manufacturer s instructions for safe operation of equipment. ALWAYS WEAR SAFETY GLASSES. Windows and doors can be very heavy and improper lifting techniques can result in serious injury. Use safe lifting techniques and a reasonable number of people with enough strength to lift, carry, and install any Parrett window and door products to avoid injury and/or damage to any product. ITEMS REQUIRED BY INSTALLER Safety Glasses Tape Measure Level Hammer Putty Knife Carpenter s Square Caulk Gun Phillips Screwdriver Power Drill Hex Wrench 3/16 Drill Bit Foam Backer Rod UV Resistant Exterior Sealant ¼ Blocks Shims Stainless Steel Fasteners o 3 Finish Nails o #10 x 1 Pan Head Screws o #10 x 1 1/2 Screws o #10 x 2 1/2 Screws

1. Unit Preparation Remove unit from packing making sure to not damage the unit. Place unit exterior side down on a clean flat work surface. Remove any loose items. Extension jamb will be factory applied unless ordered loose. DO NOT unlock or open unit until it is secured in the opening. Frame may become twisted and result in problems with performance. 2. Prepare Rough Opening Size of rough opening should allow minimum ¼ clearance around entire unit, between frame and rough opening. The width and height of the rough opening should be ½ more than unit width and height. Make sure the rough opening is square by measuring diagonally, from upper right to lower left, and upper left to lower right corner. The measurements need to be within 1/8 for the opening to be square. If the rough opening is not square, it MUST be corrected before installation. Check to make sure rough opening is plumb and level using a carpenter s square and level. The sill plate MUST be level. If rough opening is not plumb or level, correct before installation. 3. Installation Clips (If applicable) Rotate Installation Clips into position around frame, as shown, before placing unit into rough opening. If installation clips are not installed, install clips along the frame of the unit before installation. All installation clips MUST BE corrosion resitant.

4. Unit Installation Apply a 3/8 bead of UV resistant exterior sealant to back of Brickmould. Lift unit into rough opening from the exterior. Place ¼ blocks at the corners of the sill under side jambs. Add shims along the rough opening to support and level unit For mulled units, shims must be placed under mullion post(s) at sill. All mull connections MUST be properly sealed with UV resistant exterior sealant. It is necessary to consult contractor, structural engineer, architect or building owner for proper installation. Minimum recommendation would be to apply a ¼ bead of exterior sealant to interior and exterior edge of the backside of each jamb where the exterior of the jambs come in contact when mulled. After joining the two windows the exterior mull joint should then be sealed with a cap bead prior to placing mull cover/cap over the joint. It is not sufficient to simply cap bead the exterio r mull joint and place a mull cover/cap over the joint. Bend and fasten Installation Clip at the highest point with a #10 x 1 pan head screw. (If Applicable) UV resistant exterior sealant must be compatible with all materials it comes in contact with. Follow sealant manufacturer s instructions regarding surface cleaning and preparation, application, and temperature when applying sealant. Failure to do so may result in water infiltration. Metal fasteners and other hardware components may corrode when exposed to preservative treated and fireretardant treated lumber. Failure to use appropriate materials for installation may cause failure resulting in injury, property or product damage. 5. Secure Unit in Opening WOOD FRAME CONSTRUCTION Insert shims between frame and rough opening along the side jambs, just above or below Installation Clips. Check plumb, level, and square of unit. Adjust shims Bend and fasten Installation Clips to building structure using a minimum #10 x 1 screw. Recheck plumb, level and square of unit.

5. Secure Unit in Opening (continued) Nail through Brickmould every 12 using 3 finish nails. If securing through the frame, pre drill 3/16 holes through unit frame 4 from each corner and every 16 in between. Insert shims between frame and rough opening near 3/16 holes. Check plumb, level and square of unit. Adjust shims Secure unit through pre drilled holes in frame using #10 x 2 1/2 screws. Recheck plumb, level and square of unit. Correct as needed. Both Installation Clips and nailing through brickmould ar e recommended for installing all units. If both cannot be used, unit must also be secured to building structure through frame. MASONRY CONSTRUCTION CAUTION DO NOT install unit with unfinished wood in direct contact with masonry/concrete. Apply proper finish to wood surface, or place barrier (i.e. tar paper or ice/water membrane) between wood and masonry/concrete surface. Failure to do so may result in product and/or property damage. For masonry applications, install and securely fasten a wood buck or wood blocking around masonry opening before installing the window. Insert shims between frame and rough opening along the side jambs, just above or below Installation Clips. Bend and fasten Installation Clip at middle of each jamb to masonry, wood blocking, or wood buck using a minimum #10 x 1 screw. If Installation Clips are being secured directly to masonry, pre drill hole and use masonry screws. Check plumb, level, and square of unit. Adjust shims Secure remaining Installation Clips. Recheck plumb, level and square of unit.

5. Secure Unit in Opening (cont d) If securing through the frame, drill 3/16 holes through unit frame 4 from each corner and every 16 in between. If securing directly to masonry, predrill masonry for #10 x 2 1/2 masonry screws. Insert shims between frame and rough opening near 3/16 holes. Check plumb, level, and square of unit. Adjust shims Secure unit through frame using #10 x 2 1/2 screws. Use masonry screws if needed. Recheck plumb, level and square of unit. Correct as needed. 6. Check Clearance and Operation UNITS WITH BUTT HINGES Install operator and lock handle. Open sash completely and remove any Spacer Blocks from around the sash. Determine if clearance and operation are correct by opening and closing the sash. If clearance and/or operation are not correct, please make adjustments to correct performance. If problem persists, please contact your local Parrett dealer. Metal fasteners and other hardware components may corrode when exposed to preservative treated and fire retardant treated lumber. Use the appropriate metal fasteners and called out by the hardware installation guide. Failure to use appropriate materials for the installation may cause a failure resulting in injury, property or product damage. Please follow any/all instructions that are set forth by the hardware manufacturing company. Warranty will be void if correct procedures/operation is not followed.

6. Check Clearance and Operation UNITS WITH CONCEALED HINGES Install operator and lock handle. Open sash completely and remove any Spacer Blocks from around the sash. Make sure the unit operates properly by openin g and closing the sash. If clearance and/or operation is not correct, adjust by turning the pivot stud using a hex wrench. Again, check the clearance and operation. 7. Adjustments Make sure any adjustments made to the unit are recommended by Parrett Windows & Doors. Any adjustments that are NOT set forth in the installation instructions will void any warranty set forth. Install hardware as directed in the supplied instructions by the manufacturer. Parrett uses numerous types of hardware and each instruction must be followed. Contact Parrett for hardware manufacturer s instructions if needed. 8. Insulate Around Unit CAUTION When insulating between unit frame and rough opening, or between units when joining, DO NOT over pack insulation or overfill with expandable foam. Bowed jambs may result causing product performance problems. Follow insulation manufacturer s instructions. Insulate between frame, extension jambs, and rough opening on all side. DO NOT over pack insulation or overfill with expandable foam.

9. Apply Exterior Finish Apply an exterior finish leaving ¼ space between the exterior finish and the brickmould on the unit or unit frame. For masonry/brick applications, ½ space is required below sill and ¼ space around the remaining perimeter. Apply backer rod and place a continuous bead of UV resistant exterior sealant around exterior perimeter of window unit between unit brickmould and frame and exterior finish. 10. Finishing, Cleaning, and Maintenance Instructions Refer to Parrett s Care and Maintenance Instructions for all cleaning and maintenance. For finishing instructions, refer to Parrett s Homeowner s Manual at www.parrettwindows.com or contact customer service at 1 800 541 9527. Parrett will not under any circumstances be responsible for installation, repainting, refinishing or other similar activities necessary to complete any replacement. It is the consumer s responsibility for installation, finishing, cleaning, maintenance, re painting, refinishing or other similar activities necessary to maintain the performance of each window. Failure to install and maintain our product according to these instructions will VOID any warranty, written or implied. The installer is responsible for consulting the contractor, structural engineer, architect, or consumer, for proper installation according to local codes and/or ordinances.