MICRO XRF OF LIGHT ELEMENTS USING A POLYCAPILLARY LENS AND AN ULTRA THIN WINDOW SILICON DRIFT DETECTOR INSIDE A VACUUM CHAMBER

Similar documents
MICROANALYSIS WITH A POLYCAPILLARY IN A VACUUM CHAMBER

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER

DOUBLE MULTILAYER MONOCHROMATOR WITH FIXED EXIT GEOMETRY. H.Gatterbauer, P.Wobrauschek, F.Hegediis, P.Biini, C.Streli

DEVELOPMENT OF A WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER USING A MULTI-CAPILLARY X-RAY LENS FOR X-RAY DETECTION

WIDE ANGLE GEOMETRY EDXRF SPECTROMETERS WITH SECONDARY TARGET AND DIRECT EXCITATION MODES

MOXTEK S NEW ULTRA-LITE X-RAY SOURCES: PERFORMACE CHARACTERIZATIONS

USING A CHARGE-COUPLED DEVICE (CCD) TO GATHER X-RAY FLUORESCENCE (XRF)AND X-RAY DIFFRACTION (XRD) INFORMATION SIMULTANEOUSLY

Advancing EDS Analysis in the SEM Quantitative XRF. International Microscopy Congress, September 5 th, Outline

Spectral distribution from end window X-ray tubes

SIMULTANEOUS XRD/XRF WITH LOW-POWER X-RAY TUBES

Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION

DESIGN AND MEASUREMENT WITH A NEW PORTABLE X-RAY CAMERA FOR FULL-FIELD FLUORESCENCE IMAGING

BRUKER ADVANCED X-RAY SOLUTIONS. SPECTROMETRY SOLUTIONS ARTAX mxrf SPECTROMETER

M4 TORNADO PLUS. Innovation with Integrity. Super Light Element Micro-XRF Spectrometer. Micro-XRF

ARTAX. Innovation with Integrity. Portable Micro-XRF Spectrometer. Micro-XRF

X-RAY BACKSCATTER IMAGING: PHOTOGRAPHY THROUGH BARRIERS

TOWARDS SUB-100 NM X-RAY MICROSCOPY FOR TOMOGRAPHIC APPLICATIONS

M6 JETSTREAM. Innovation with Integrity. Large Area Micro X-ray Fluorescence Spectrometer. Micro-XRF

GUNSHOT RESIDUE INVESTIGATIONS USING TXRF

Copyright -International Centre for Diffraction Data 2010 ISSN

Supplementary Figure S1. Schematic representation of different functionalities that could be

FAST ELEMENTAL MAPPING WITH MICRO-XRF

X-Ray Spectroscopy with a CCD Detector. Application Note

LYNXEYE XE-T. < 380 ev. Innovation with Integrity. Energy. Resolution. High-Resolution Position Sensitive Detector with Superb Energy Resolution XRD

Zaidi Embong and Husin Wagiran Physics Department, University Of Technology Malaysia, P.O Box 791, 80990, Johor Baharu

LONG TERM STATISTICS OF X-RAY SPECTROMETERS

ON THE DETECTION LIMIT OF TEY (TOTAL ELECTRON YIELD) Maria F. Ebel, Horst Ebel and Robert Svagera

research papers First results from a macromolecular crystallography system with a polycapillary collimating optic and a microfocus X-ray generator

AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

ON THE ENERGY DEPENDENCE OF THE DETECTOR EFFICIENCY OF A Si-PIN DIODE

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Author s Accepted Manuscript

Silicon Drift Detector. with On- Chip Ele ctronics for X-Ray Spectroscopy. KETEK GmbH Am Isarbach 30 D O berschleißheim GERMANY

LYNXEYE XE. Innovation with Integrity. High-Resolution Energy-Dispersive Detector for 0D, 1D, and 2D Diffraction XRD

OPTIMIZING THE ELEMENTAL SENSITIVITY AND FOCAL SPOT SIZE OF A MONOLITHIC POLYCAPILLARY OPTIC USING MICRO-X-RAY FLUORESCENCE

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

TOWARDS FAST RECIPROCAL SPACE MAPPING

MICROFOCUSING X-RAY EQUIPMENT FOR THE LAB DIFFRACTOMETER

CONFOCAL GRADED d-spacing MULTILAYER BEAM CONDITIONING OPTICS

Cr, Co, Cu, Mo, Ag (others on request) Mean Reflectivity: R > 70%

POLYCAPILLARY OPTICS AND X-RAY ANALYTICAL TECHNIQUES

(Refer Slide Time: 00:10)

Supplementary Materials

Low Cost Rolled X-ray Prism Lenses to Increase Photon Flux Density in Diffractometry Experiments

Scanning electron microscope

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Bruker Nano. M4 tornado. High performance micro-xrf spectrometer. think forward

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

DESIGN OF SINGLE-BOUNCE MONOCAPILLARY X-RAY OPTICS

Phase Imaging Using Focused Polycapillary Optics

On-line spectrometer for FEL radiation at

High Rep-Rate KrF Laser Development and Intense Pulse Interaction Experiments for IFE*

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Radiographic sensitivity improved by optimized high resolution X -ray detector design.

Applications of Micro XRF for the Analysis of Traditional Japanese "Ainu" Glass Beads and other Artifacts

STATE-OF-THE-ART SILICON DETECTORS FOR X-RAY SPECTROSCOPY

Introduction to X-ray Detectors for Synchrotron Radiation Applications

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

A MONTE CARLO CODE FOR SIMULATION OF PULSE PILE-UP SPECTRAL DISTORTION IN PULSE-HEIGHT MEASUREMENT

Phase Contrast Imaging with X-ray tube

Preliminary Comparison of Monolithic and Aperture Optics for XRMF. George J. Havrilla CST-8 Christopher G. Worley CST-8

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry

Improving the Collection Efficiency of Raman Scattering

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

cividec DIAMOND DETECTORS & SYSTEMS FOR X-RAYS Instrumentation CIVIDEC Instrumentation GmbH Vienna The Netherlands +31 (0)

StarBright XLT Optical Coatings

R-AXIS RAPID. X-ray Single Crystal Structure Analysis System. Product Information

Water-Window Microscope Based on Nitrogen Plasma Capillary Discharge Source

Spatially Resolved Backscatter Ceilometer

DALLA LUCE VISIBILE AI RAGGI X: NUOVI RIVELATORI DI IMMAGINI PER RAGGI X A DISCRIMINAZIONE IN ENERGIA ED APPLICAZIONI

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

SUPPLEMENTARY INFORMATION

Multi-Element Analysis by Portable Total Reflection X-ray Fluorescence Spectrometer

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Development of X-ray Tool For Critical- Dimension Metrology

Pixel hybrid photon detectors

Supplementary Figure 1

Test procedures Page: 1 of 5

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

UltraGraph Optics Design

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

RIGAKU VariMax Dual Part 0 Startup & Shutdown Manual

Supplementary Information. Stochastic Optical Reconstruction Microscopy Imaging of Microtubule Arrays in Intact Arabidopsis thaliana Seedling Roots

Nano Beam Position Monitor

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

A Novel Multipass Optical System Oleg Matveev University of Florida, Department of Chemistry, Gainesville, Fl

Observational Astronomy

X-ray tube with needle-like anode

Partial Replication of Storms/Scanlan Glow Discharge Radiation

Better Imaging with a Schmidt-Czerny-Turner Spectrograph

Lab Report XRF 441 Elemental distribution analysis on geological samples with the M4 TORNADO

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Scanning Electron Microscopy

plasmonic nanoblock pair

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

Transcription:

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 229 MICRO XRF OF LIGHT ELEMENTS USING A POLYCAPILLARY LENS AND AN ULTRA THIN WINDOW SILICON DRIFT DETECTOR INSIDE A VACUUM CHAMBER P. Wobrauschek, B. Frank, N. Zoeger, C. Streli, N. Cernohlawek, C. Jokubonis, and H. Hoefler ABSTRACT Atominstitut, TU-Wien, A-1020 Vienna, Austria Since most micro-spectrometers are operated in air, up to now only mapping of medium and higher Z elements was possible with micro X-ray fluorescence analysis (µ-xrf). Though for some applications (e.g.: biological- and geological samples, samples from art and archeology) the extension to light elements is of great interest. Therefore µ-xrf measurements using a polycapillary lens mounted inside a vacuum chamber have been performed. X-rays from a 2kW high power diffraction tubes (Mo and Cr anode) as well as from a low power 50 W Pd-anode tube were focused by means of the polycapillary X-ray optics. The polycapillary adjustment was performed with a combination of an X/Y stage and a gimbal allowing 3 translation and 2 rotation movements. With this setup it was possible to produce an X-ray spot of about 40µm in diameter at the sample surface. Sample motion is performed by an x-y-z-micrometer driven stage PC controlled. The position dependent fluorescence signal was collected by a Peltier cooled energy dispersive detector (10 mm2 Silicon Drift type) with an ultrathin window (300nm) allowing the detection down to oxygen. Scanning measurements have been carried out on various samples of human femural bone. Results from an area scan (500 x 1100 µm 2 ) across the transition zone of trabecular- and cortical bone are presented, including the distribution of O, P, Ca, and Zn. To compare the performance of the different anode X-ray tubes single point measurements on NIST glass (soda lime glass) have been performed with regard to light element detection. A comparison of results using the different excitation conditions of Mo-L and Pd-L on various samples will be presented with excellent conditions regarding excitation, detection, and background using a vacuum chamber for µ-xrf. INTRODUCTION Micro X-ray fluorescence analysis (µ-xrf) has nowadays become a well established method to nondestructively determine elemental distributions in various types of samples with a spatial resolution of about 10-30µm [1-4]. Many laboratory and commercial systems have been developed, using either monocapillary or polycapillary X-ray optics to produce an intense microbeam at the sample surface. Since most of the micro-spectrometers are operated in air the fluorescence radiation with lower energy is absorbed on the way to the detector and the detectable elemental range is therefore practically limited to elements above S (E Kα = 2.3keV). To overcome this problem and to have the possibility to measure the distribution of low-z elements in the sample a microbeam vacuum chamber has been designed [5]. The main goal was to reduce absorption of the fluorescence radiation between sample and detector as well as to reduce the scattering in air. The spectral background is minimized, the Ar- K line practically removed, and optimized conditions for the detection of light elements are achieved. A further

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 230 advantage arises when using capillary optics as focusing devices, which is based on total reflection of X-rays. When X-rays propagate through a glass channel, total external reflection on the capillary walls occurs. Due to the energy dependence of the critical angle for total reflection, higher energy photons are absorbed in the capillary. Only X-rays with lower energy than high energy cut off energy are reflected towards the exit of the device (cut-off effect), leading to efficient excitation of light elements. In addition the background in the low energy region is improved as the Compton edge resulting from backscattered high energy photons from the detector itself is missing as the high energy photons are not present. EXPERIMENTAL The existing vacuum chamber described earlier has been improved [5]. A capillary adjustment unit has been installed inside the chamber, where the combination of an X/Y stage and a gimbal mount allows to perform a 5-axis movement (3 translations, 2 rotations). By iteratively changing the five degrees of freedom and controlling the focused beam either optically (ZnS screen + microscope) or by successively scanning a Cu or W wire of 10µm thickness across the beam an optimal alignment of the capillary was reached. For beam focusing a monolithic polycapillary optics (1203-01) from XOS [6] with an entrance focal lengths of 53mm, an exit focal length of 13.5mm and a length of 62mm was used. For optically controlling the measurement position a microscope with long working distance of 165mmm (Olympus) and a CCD camera attached to it is placed outside the vacuum chamber looking through an adequate sized borehole into the chamber on the sample. To perform automatic scanning of the sample relative to the incoming beam the samples were mounted on an XYZ sample stage with 3 motorized, micrometer driven, translation stages. An ORIEL controller and a self developed software allows communication between MCA, motion control, and micrometers. A stepsize from 1µm upwards can be choosen and 25mm x 25 mm horizontal x vertical travel is possible. The fluorescence photons were detected by a KETEK silicon drift detector [7] with an active area of 10mm 2, a thickness of 300 µm thickness, and a resolution of 140eV FWHM @5.9 kev, equipped with an ultrathin window of 300nm thickness (Moxtek, AP1.3), which offers a transmission of 60% for the Oxygen-Kα line (523 ev). The angles between beam-sample and sample-detector were fixed to 45 each. Two different tubes were used: an OXFORD [8] low power tube with Pd anode (50 W) with a focal spot size of 150 x 70 µm and a 2kW diffraction tube with Mo target, focal spot 8 x 0.4 µm (point focus). The setup with the low power tube attached is shown in Figure1.

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 231 Figure 1. µ-xrf vacuum chamber: schematic view (a), overview (b), polycapillary, adjustment- and sample stages (c) and detail view (d). RESULTS The respective focal spots obtained after careful adjustment of the polycapillary with the 2 different tubes have been determined by scanning a 10 µm Cu wire in the focal plane of the capillary. The beam size was determined to be 42 µm for the low power Pd tube and 41 µm for the Mo diffraction tube (Figure 2). The calculation of the beam size respects all correction effects due to the measuring geometry under 45 degree motion versus the incident beam direction.

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 232 Cu 10µm wire Intensity [cts] 14000 12000 10000 8000 6000 4000 Pd FWHM 43µm Beamsize 42µm Mo FWHM 42µm Beamsize 41µm Pd low Power Mo 120000 100000 80000 60000 40000 Intensity [cts] 2000 20000 0-2000 6920 6940 6960 6980 7000 7020 7040 7060 7080 motor position [µm] 0 Figure 2. Scan of a 10 µm Cu wire. The beamsize was determined to be 42 µm for the Pd low power tube (blue) and 41 µm for the Mo anode diffraction tube (red). For better representation the 0 position has been slightly changed for the ordinates left (Pd) and right (Mo). A performance comparison of the two X-ray tubes was done by single point measurements on NIST SRM621, soda lime glass. Figure 3 shows the spectrum obtained with the low power tube. A comparison of the Ca net counts and the operating conditions for each experiment are shown in Table 1. Table 1. NIST SRM621, soda lime glass, measured with the 2 X-ray tubes. tube kv ma Ca net counts in 1000s Pd 30 0.9 2600 Mo 30 10 2959 The obtained result is about the same, showing that the low power tube provides practically the same photon flux through the polycapillary as the high power tube. Although a higher electron current can be applied to the diffraction tube (due to better heat dissipation of the larger focal area), the point to point X-ray optical properties of the capillary accepts the same fraction (40µm) of the focal spot on the anode for both tubes. Figure 4 shows a single spectrum from the scan across the transition between trabecular and cortical bone in a slice of human hip head performed with the Pd low power tube. Since the Ca- Ka escape peak of the Si detector has an energy of (E( Ca-escape) = 1.95 kev) overlaps partly with the P-K line (E (P-Kα) = 2.01 kev) special excitation conditions had to be chosen for this scan. The tube voltage was set to 15 kv to excite the Pd-L lines (E(Lα) = 2.84 kev, E(Lβ) = 2.99 kev) efficiently from the anode material. The Pd-K lines (E(Kα) = 21.12 kev, E(Kβ) = 23.86 kev) are not present in the exciting X-ray spectrum. Thus the excitation of Ca (only excited by the bremsstrahlung) was reduced, while P was efficiently excited by the Pd-L lines. By operating

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 233 the system at this so called selective excitation conditions the Ca escape peak could be almost suppressed (5 per mill of the Ca intensity) and it was possible to obtain reliable data for P. Figure 3. Spectrum of NIST SRM 621 soda lime glass, excited with the low power tube. Figure 4. spectrum of trabecular bone, excited with the Pd tube at 15 kv. Results from the whole scan of a 200µm thick bone slice across the transition zone articular cartilage-cortical/trabecular bone are shown in Figure 5. The operation conditions of the tube were 15kV/0.9mA and a measuring time of 80s per pixel was chosen to achieve data with good counting statistics. Element maps of O, P, S, Cl, and Ca as well as the calculated intensity ratio between Ca and P are displayed. From the maps of Ca and P one can see the structure of the bone analyzed, showing clearly the region of cortical bone (horizontal area of high intensities in the middle of the map) with adjacent trabecular bone. S can be regarded as a marker for articular cartilage and was therefore only detected outside of the bone substance. Although Oxygen should be more or less equally distributed over the entire area higher O intensities were detected in the

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 234 region of articular cartilage. This is due to the fact that O is much more absorbed in the bone matrix (mostly Ca) than it is in the matrix of cartilage (no Ca). Figure 5. Area scan of 200µm bone slice. In the transition zone cortical/trabecular bone Pd 15kV 0.9mA 80s per point, Scanned area: 23 x 27 pixels, 1150µm x 1350µm, Distance between pixels: 50µm, measuring time per pixel: 80s. CONCLUSIONS Inside the chamber technical improvements were made. The adjustment unit for the monolithic polycapillary has been installed successfully and reduced the focal spot from 69 µm to 42 µm. A comparison of a low power Pd anode tube with the Mo anode diffraction tube showed almost same intensity of Ca, though the power was a factor of 10 higher for the diffraction tube. Microanalysis of low-z elements is possible when using an SDD with ultrathin window. Using selective excitation, the Ca/P ratio in bone can be determined. ACKNOWLEDGEMENTS The authors would like to acknowledge the Physics, Chemistry, Instrumentation Laboratory, the IAEA Laboratories Seibersdorf for providing the low power X-ray tube. REFERENCES: [1] Kumakhov, SPIE 2859, 116 (1996) [2] Hoffman, Thiel, Bilderback, Nucl. Instr. Meth. A347,384 (1994) [3] B. Vekemans, K. Janssens,G. Vittiglio, F. Adams, L. Andong, Y. Yiming, JCPDS, (1999),278-290 [4] G.Havrilla, Adv.Ax-ray Anal.41, 234 (1999)

Copyright JCPDS - International Centre for Diffraction Data 2005, Advances in X-ray Analysis, Volume 48. 235 [5] C. Streli, N. Marosi, P. Wobrauschek, B. Frank, The Rigaku Journal 20(2), 25-29 (2003) [6] www.x-rayoptivs.com [7] www.ketek.net [8] www.oxfordxtg.com