CU-LASP Test Facilities! and Instrument Calibration Capabilities"

Similar documents
Part 1: New spectral stuff going on at NIST. Part 2: TSI Traceability of TRF to NIST

The TSIS Spectral Irradiance Monitor: Prism Optical Degradation Studies

Capabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments

Irradiance Calibration Using a Cryogenic Radiometer and a Broadband Light Source

NIST Agency Report May 2012 OUTLINE. The case for traceability NMI capabilities A view to the future the HIP Current/recent NIST activities

Total solar irradiance measurements with PREMOS/PICARD

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

ACRIM3 Characterization by the LASP/TRF and the Total Solar Irradiance Database

Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,

Measurements of Infrared Sources with the Missile Defense Transfer Radiometer

Influence of the light spectral distribution used in the radiometers calibration

Status of Low-Background Infrared Calibration Facility at NIST

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

NIST EUVL Metrology Programs

Spatially Resolved Backscatter Ceilometer

Chemistry Instrumental Analysis Lecture 10. Chem 4631

Legacy of NOAA, NASA and NIST Cooperation in Developing Radiometric Calibration Standards Equipment and Methodologies. Raju Datla, Michael Weinreb

TRACEABLE SOLAR RADIATION MEASUREMENTS

event physics experiments

Development of four-dimensional imaging spectrometers (4D-IS)

Development of 2 Total Spectral Radiant Flux Standards at NIST

ISUAL Test Plans and Procedures

SCCH 4: 211: 2015 SCCH

LBIR Fluid Bath Blackbody for Cryogenic Vacuum Calibrations

Evaluation of high power laser diodes for space applications: effects of the gaseous environment

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES

New automated laser facility for detector calibrations

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

SPECTRAL IRRADIANCE DATA

Experimental Analysis of Luminescence in Printed Materials

GaN-based Schottky diodes for EUV/VUV/UV photodetection

Spectroradiometer characterisations for traceable solar radiation measurements

Jam Lab Capabilities. Charles Dionne. Matthew Pilat. Jam Lab Manager

Historical. McPherson 15 Mount

UV Measurement. Information Sheet. Dipl.-Ing. Andreas Renzel. Basics of UV measurement and solutions for UV curing applications.

A stray light corrected array spectroradiometer for complex high dynamic range measurements in the UV spectral range.

Chemistry Instrumental Analysis Lecture 7. Chem 4631

Calibration of ARM Spectral Shortwave Radiometers

Improved Radiometry for LED Arrays

Oriel Flood Exposure Sources

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

RADIATION BUDGET INSTRUMENT (RBI): FINAL DESIGN AND INITIAL EDU TEST RESULTS

Japan Update. EUVA (Extreme Ultraviolet Lithography System Development Association) Koichi Toyoda. SOURCE TWG 2 March, 2005 San Jose

Of straying photons, shiny apertures and inconstant solar constants Advances in TSI radiometery

UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

Laser Beam Analysis Using Image Processing

RAMSES. A modular multispectral radiometer for light measurements in the UV and VIS

TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers.

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Report on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

MULTI-FILTER ROTATING SHADOW BAND RADIOMETER MODEL MFR-7 BULLETIN MFRSR-7

Model S471-LED Optometer

Radiometric performance of Second Generation Global Imager (SGLI) using integrating sphere

Mercury TM 1500V Vacuum Rated Digital Output Encoders

membrane sample EUV characterization

LASP / University of Colorado

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Radiometric Measurement Traceability Paths for Photovoltaic Calibrations. Howard W. Yoon Physical Measurement Laboratory NIST

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

We bring quality to light. MAS 40 Mini-Array Spectrometer

2. Instrumentation Design, Specifications, and Installation of the SUV-100

RADIOMETRIC AND PHOTOMETRIC MEASUREMENTS AT THE LNE-INM/CNAM

The New Standard in Lightfastness Testing

Pulsed Laser Power Measurement Systems

Technology Days GSFC Optics Technologies. Dr. Petar Arsenovic

Working in Visible NHMFL

Engineering Challenges and Solutions for MeRHIC. Andrew Burrill for the MeRHIC Team

Kazuhiro TANAKA GCOM project team/jaxa April, 2016

Miniaturized Spectroradiometer

Sensor Fusion Enables Comprehensive Analysis of Laser Processing in Additive Manufacturing

Introduction. Laser Diodes. Chapter 12 Laser Communications

GEO-SolarSIM-D2 and SunTracker-2000/3000

Broadbandradiometer specbos 1211

Team Ram-Rod Helios Conceptual Design Review. Aaron Gardiner Tyler Murphy Vivian Phinney Farheen Rizvi Ali Toltz

CIRiS: Compact Infrared Radiometer in Space August, 2017

Carbon Nanotube Radiometer for Cryogenic Calibrations

Status of Aeolus ESA s Wind Lidar Mission

Basic Components of Spectroscopic. Instrumentation

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration


Frequency Scanned Interferometer Demonstration System

Cross Track Infrared Sounder (CrIS) Flight Model 1 Test Results

The New Standard in Lightfastness Testing. Q-Sun B02 Xenon Lightfastness Tester. The Lightfastness Specialists

apogeeinstruments.com Introducing the PV-100 PV Monitoring Package

MUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM

DIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

1/8 m GRATING MONOCHROMATOR

AIAA/USU Small Satellite Conference 2007 Paper No. SSC07-VIII-2

pulsecheck The Modular Autocorrelator

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains

Pyranometers SP- 100 Series SP -200 Series

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

The FTNIR Myths... Misinformation or Truth

Radial Coupling Method for Orthogonal Concentration within Planar Micro-Optic Solar Collectors

Solar Irradiance Sensor on the ExoMars 2016 Lander

Transcription:

CU-LASP Test Facilities! and Instrument Calibration Capabilities" Ginger Drake Calibration Group Manager 303-492-5899 Ginger.Drake@lasp.colorado.edu

Thermal Vacuum Test Facilities" 2 Multiple Optical Beam Instrument (MOBI) Largest of LASP s vacuum chambers Ideal for performing top-level instrument tests Thermal Vacuum tests In-band light testing (EUV-IR) Independently temperaturecontrolled shroud and platen Optional 4-axis precision gimbal pitch, yaw, x, y Interior dimensions: 60 diameter x 72 length Temperature range: -180 C to +150 C Base pressure: 1 x 10-7 Torr

Thermal Vacuum Test Facilities" 3 East and West Bemco Chambers Two similar chambers One located inside Class-10,000 cleanroom Platen temperature controlled via recirculating chiller Optimal for smaller-scale tests Mechanism performance Burn-ins Life tests Interior dimensions: 30 Diameter x 48 length Temperature range: -75 C to +80 C Base pressure: 1 x 10-7 Torr

Bake Out Facilities" 4 Three vacuum chambers Vacuum bake flight & non-flight components Verify cleanliness and characterize outgassing properties RGA, TQCM and CQCM Acceptable materials include: Metals, PC boards, harnesses, optics, plastics, polymerics, elastomers Air-bake chamber Room temp to +200C Size ranges 13 H x 13 W x 16 D to 22 H x 21 W x 33 D Temperature range +30 C to +125 C

Optical Vacuum Test Facilities" 5 Calibration and Test Equipment 2 (CTE 2) Used to calibrate detectors and detector subsystems Optimized for 120 400nm Computer-controlled monochromator for wavelength selection Deuterium lamp is primary light source 2 axis steerable beam Incorporates NIST-traceable photodetector for absolute measurements Internal dimensions 15 H x 23 W x 48 D Temperature range -180 C to +80 C

Optical Vacuum Test Facilities" 6 Calibration and Test Equipment 3 (CTE 3) Characterization of detectors and detector modules Optimized for 0.1 200nm Two monochromators Grazing, normal incidence Multiple light sources X-ray: Manson, Fe-55 EUV: hollow cathode with various process gases H, He, Ar, N, Ne, etc. UV: deuterium Internal dimensions 24 H x 20 W x 32 L Temperature range -180 C to +80 C

Optical Vacuum Test Facilities" 7 Spectral Radiometer Facility (SRF) Absolute spectral irradiance & response calibrations Cryogenic radiometer provides NIST-traceable primary radiometric reference standard Tunable lasers 210 3300nm 40mW-18W output power Five-axis vacuum manipulator Pitch, yaw, roll, x, y Internal dimensions 23 H x 29 W x 40 L Temperature range +5 C to +50 C

Optical Vacuum Test Facilities" 8 Total Solar Irradiance Radiometer Facility (TRF) Total Solar Irradiance (TSI) instrument calibrations 0.01% absolute accuracy 532nm laser light source Cryogenic radiometer provides NIST-traceable primary radiometric reference standard Internal dimensions 24 H x 20 W x 32 L

Heliostat Optical Test Facility" 9 Heliostat Lab 3-mirror system directs sunlight into black optics lab Equatorial mount in closedloop control Quad-diode provides real-sun time tracking <10 arc-second tracking error Lab contains class 10,000 clean area with 4 x 8 optical bench for sensitive instruments

Environmental Test Chambers" 10 Temperature & Humidity Testing in Atmosphere 4 programmable test chambers Dry N 2 purge available Temperature range -73 C to +200 C Interior dimensions Range of sizes from 13 x 16 x 17 to 30 x 32 x 36

Optical Design & Analysis" 11 Design and analysis includes: Imagers Spectrographs Hyperspectral imagers X-ray to IR spectrometers Photometers Star tracker Solar position sensors Test & calibration applications End-to-end instrument performance modeling Stray light analysis Tolerance & STOP analysis Industry-standard software Zemax, FRED

3-D Magnetic & Radiation Dose Modeling" 12 Magnetic designs Electron rejection magnet arrays Rejection efficiency models Radiation shielding and dose models Analyze 3-D Solidworks models of instruments High-Z, Low-Z material models Dose, background signal & noise estimates

Instrument Calibration & Characterization" 13 Optical focus & alignment In-band temperature-dependent characterization & adjustment of imaging performance Absolute & Relative Radiometric sensitivity Absolute to 0.01% through NISTtraceable standards Test as you fly Characterize instrument performance under thermal & vacuum conditions expected on orbit

Custom Detector Design & Fabrication" 14 Electronic Substitution Radiometer Solar Spectral detector >1% absolute accuracy at µw power levels 100ppm absolute accuracy at total Solar signal levels Dust Detector Photomultiplier Tubes (PMTs) Develop Custom detectors with vendors Large-format CCDs Photodiode & diode arrays Hyperspectral CMOS arrays