Self-powered Tachometer

Similar documents
Self-powered Counter

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure

Solid-state Timer H3DS

Solid-state Twin Timer

Self-Powered Counters H7ET

Model Number Structure

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Count/Time Totalizers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Solid-state Timer H3DE

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

NPN PNP NPN PNP NPN PNP

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Solid-state Timer H3DE

Solid-state Timer H3DS

Solid-state Timer H3DS

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Contents H3DS. DIN Track Mounted, Standard 17.5-mm Width Timer Range. Broad Line-up of H3DS Series. Solid-state Timer. Common to ALL Timers H3DS-X

Bulletin 700-HX Multifunction Digital Timing Relay

CompoBus/D-type Digital Controller

Digital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Model Number Structure

Capacitive Proximity Sensor

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

WARNING. 5 Mounting. 1 CE marking. 2 Confirmation of packed content. 3 Safe use of laser product. 4 Part description. Instruction Manual

Phase-sequence Phase-loss Relay

Model Number Structure

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

Model Number Structure

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Multifunctional counter tico 772/773/774

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

em4 em4 alert em4 alert 2G

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

Surface-mounting Relay

Emitting and receiving element pitch: 10 mm in

SPST-NO SPDT DPST-NO DPDT

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

MOS FET Relay. Ordering Information. SSR for Switching Analog Signals, with an Insulation Value of 2.5 kvac between Input and Output Terminals

Solid-State Digital Counter H7AN

em4 local - Robust Specific characteristics Part number

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

KCM-50/51 Series. Consolidated Counter (Maintenance Counter) Features KCM-50 Series. KCM-51 Series. Electronic Counter / Controller.

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Model Number Structure

MARTINDALE INSTRUCTIONS. E-ZeTest EZ2500 LOOP TESTER ELECTRIC. Trusted by professionals. Other products from Martindale:

Distance-setting Photoelectric Sensor

E2B PROXIMITY SENSORS

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Remote Sensor Amplifier Terminal

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

A W - A 2A R - 24D - 1

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

OMRON MK-I / -S RELAY

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

AC/DC CLAMP METER USER S MANUAL

EE-SX770/771/772/870/871/872(A/P/R)

Details on the New G2RS

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

Classification Enclosure rating Contact form Contact material

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Process Meter. Applicable

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Built-in Amplifier Photoelectric Sensor

3. Contact Form A: SPST-NO

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

High-precision Optical Switch

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Custom "Compact" range with display CD20 Custom Part number

Limit Switch Style Inductive Prox

EE-SPX613. Ordering Information. An Ideal Photomicrosensor for Detecting Liquid Levels in Transparent Pipes

Cylindrical type proximity sensor

RE17LLBM asymmetrical flashing relay s V AC - solid state output

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

Distance-setting Photoelectric Sensor

Transcription:

Self-powered Tachometer H7ER Revolutions displayed up to five digits. Dual revolution display accding to encoder resolution used; 1000 s 1 /1000 min 1 1000.0 s 1 /1000.0 min 1 Switchable dual revolution display type available (-NV1 models); extended up to 10000 min 1 Ordering Infmation Tachometers Count input Display Max. revolutions displayed (applicable encoder resolution) 1000 s 1 (1 pulse/rev.), 1000 min 1 (60 pulse/rev.) 1000.0 s 1 (10 pulse/rev.), 1000.0 min 1 (600 pulse/rev.) 10000 min 1 (60 pulse/rev.) (switchable) Light-gray body Black body Light-gray body Black body PNP/NPN 7-segment LCD H7ER-NV-H H7ER-NV-BH H7ER-NV1-H H7ER-NV1-BH universal DC voltage input with backlight 7-segment LCD H7ER-NV H7ER-NV-B H7ER-NV1 H7ER-NV1-B No-voltage input 7-segment LCD H7ER-N H7ER-N-B --- --- Model Number Legend H7ER - N - 1 2 3 4 1. Count Input None: No-voltage input V: PNP/NPN universal DC voltage input 2. Number of Digits None: 4 digits 1: 5 digits 3. Case Col None: Light gray B: Black 4. Display None: 7-segment LCD without backlight H: 7-segment LCD with backlight Accessies (Order Separately) Lithium Battery Y92S-36 Wire-wrap Terminal (Set of two Terminals) Y92S-37 Flush Mounting Adapter 26 mm 45 mm Y92F-75 24.8 mm 48.8 mm Y92F-77B 19

New H7ER New H7ER Specifications General Item Operating mode Mounting method H7ER-NV- H7ER-NV- H Up type Flush mounting H7ER-N- External connections Screw terminals, Wire-wrap Terminals (see note 3) H7ER-NV1- H7ER-NV1- H Display 7-segment LCD with without backlight (character height: 8.6 mm) (see note 4) Number of digits 4 5 Count input PNP/NPN universal DC voltage input No-voltage input Max. counting speed 1 khz 10 Hz Max. revolutions displayed (see note 5) 1,000 s 1 (When encoder resolution of 1 pulse/rev is used.) 1,000 min 1 (When encoder resolution of 60 pulse/rev is used.) PNP/NPN universal DC voltage input 1,000.0 s 1 (When encoder resolution of 10 pulse/rev is used.) 1,000.0 min 1 (When encoder resolution of 600 pulse/rev is used.) 10,000 min 1 (When encoder resolution of 60 pulse/rev is used.) (Switchable with switch) Attachment Waterproof packing, flush mounting bracket, revolution unit labels (see note 5) Approved standard Note: 1. Reset is not available. UL508, CSA C22.2 No.14, Lloyds Confms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage categy III) Confms to VDE0106/P100 2. When there is no input, the display will be 0.0 0. 3. Separately dered Wire-wrap Terminals (Y92S-37) are required. 4. Only PNP/NPN Universal DC voltage input models have a backlight. 5. rpm, rps, s 1 and min 1 labels are included. Ratings Supply voltage Count input Reset input Item Max. counting speed Minimum signal width Terminal screw tightening tque H7ER-NV - H7ER-NV - H Backlight model: 24 VDC (0.3 W max.) (f backlight lit) No-backlight model: Not required (powered by built-in battery) High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input impedance: Approx. 4.7 kω) 4-digit models: 1 khz 5-digit models: 10 khz 10 Hz: 0.05 ms 1 khz: 0.5 ms 0.98 N m max. H7ER-N- Not required (powered by built-in battery) No voltage input Maximum sht-circuit impedance: 10 kω max. Sht-circuit residual voltage: 0.5 V max. Minimum open impedance: 750 kω min. 1 khz Ambient temperature Operating: 10 C to 55 C (with no condensation icing) Stage: 25 C to 65 C (with no condensation icing) Ambient humidity Operating: 25% to 85% 20

New H7ER New H7ER Characteristics Item Insulation resistance Dielectric strength Impulse withstand voltage Noise oseimmunity Static immunity Vibration resistance Shock resistance H7ER-NV - H7ER-NV - H 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts, and between the backlight power supply and count input terminals/reset terminals f backlight models 1,000 VAC, 50/60 Hz f 1 min between current-carrying metal parts and exposed non-current-carrying metal parts and between the backlight power supply and count input terminals/reset terminals f backlight models H7ER-N- 100 MΩ min. (at 500 VDC) between current-carrying metal parts and exposed non-current-carrying metal parts 1,000 VAC, 50/60 Hz f 1 min between current-carrying metal parts and exposed non-current-carrying metal parts 4.5 kv between current-carrying terminal and exposed non-current-carrying metal parts Square-wave noise generated by noise simulat (pulse width: 100 ns/1 µs, 1-ns rise) ±600 V (Between count input terminals) ±480 V (Between the backlight power supply terminals f backlight models) ±8 kv (malfunction) ±500 V (Between count input terminals) Malfunction: 0.15-mm single amplitude at 10 to 55 Hz f 10 min each in 3 directions Destruction: 0.375-mm single amplitude at 10 to 55 Hz f 2 hrs each in 3 directions Malfunction: 200 m/s 2 3 times each in 6 directions Destruction: 300 m/s 2 3 times each in 6 directions EMC (EMI) EN50081-1 Emission Enclosure: EN55022 class B (EMS) EN50082-2 Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: ENV50204: 10 V/m (900 MHz ± 5 MHz) (level 3) Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz ) (level 3) Immunity Burst: EN61000-4-4: 2-kV power line (level 3) 2-kV I/O signal line (level 4) Enclosure rating Front panel: IP66, NEMA4 with waterproof packing Terminal block: IP20 Weight (see note) No-backlight model: Approx. 60 g Backlight model: Approx. 65 g Note: Weight includes waterproof packing and flush mounting bracket. Reference Value Battery life Item Value Note 7 years min. with continuous input at 25 C (lithium battery) The battery life is calculated accding to the conditions in the left column and therefe is not a guaranteed value. Use these value as reference f maintenance replacement. 21

New H7ER New H7ER Nomenclature Front view H7ER Counting speed switch F H7ER-NV1- Not used Bottom view Counting Speed Switch Settings and Unit Label Application Model Counting speed switch setting (see note) Max. revolutions displayed Applicable encoder resolution Applicable unit label Front panel H7ER-NV1-10000 min 1 (default setting) 60 pulse/rev. min 1 rpm 1000.0 min 1 600 pulse/rev. min 1 rpm Terminal block 1000.0 s 1 10 pulse/rev. s 1 rps H7ER-N- H7ER-NV- No setting is required 1000 min 1 1000 s 1 60 pulse/rev. min 1 rpm 1 pulse/rev. s 1 rps Note: Perfm switch setting befe mounting to a control panel. Operation Operating Modes H7ER Tachometer Incrementing Operation Within Unit Time (Up) Internal gate Count period (1 s) 0.25 s Count period (1 s) Display refreshed Counter reset Refresh Internal count value Number display Previous count value display Display refreshed every 1.25 s Display refreshed every 1.25 s 22

New H7ER New H7ER Dimensions Note: All units are in millimeters unless otherwise indicated. H7ER-N Panel Cutout Separate mounting 60 min. 45 +0.5 0 Dimensions with Flush Mounting Bracket Joint mounting 22.2 +0.5 0 (48 Units - 2.5) +1.0 0 22.2 +0.5 0 Waterproofing is not possible f joint mounting When mounting, insert the Counter into the cutout, insert the adapter from the back and push in the Counter while making the gap between the front panel and the cutout panel as small as possible. Use screws to secure the Counter. If waterproofing is desired, insert the waterproof packing. When several Counters are installed, ensure that the ambient temperature will not exceed specifications. The appropriate thickness of the panel is 1 to 5 mm. 23

New H7ER New H7ER Installation Terminal Arrangement Bottom view: View of the Tachometer rotated hizontally 180 Backlight Model No-backlight Model Backlight 24 VDC Pulse input Pulse input Connections H7ER Tachometer Note: Select input transists accding to the following: Dielectric strength of the collect 50 V Leakage current < 100 µa (1 µa f no-voltage input model) PNP/NPN Universal DC Voltage Input Models With Backlight Transist Input No-voltage Input Model Transist Input (Open Collect of an NPN Transist) Open collect of an NPN transist Open collect of an PNP transist Input Backlight 24 VDC Open collect of an NPN transist Input PNP/NPN Universal DC Voltage Input Models Without Backlight Transist Input Open collect of an NPN transist Open collect of an PNP transist Input 24

New H7E New H7E Accessies (Order Separately) New H7E (Except f PCB-mounting Counter) The New H7E models are supplied with a mounting bracket and nut. Additionally, the Flush Mounting Adapters shown here allow the New H7E models to be fitted to existing panel cutouts. Y92F-75 Flush Mounting Adapter f 26 45.3 Rectangular Cutout Use mounting bracket supplied with the Counter Panel Cutout Y92F-77B Flush Mounting Adapter f 24.8 48.8 Rectangular Cutout Use mounting bracket supplied with the Counter Panel cutout 28.8 24.2 22.2 24.8 45.2 48.2 53.8 4 48.8 Y92S-37 Wire-wrap Terminal (Set of Two Terminals) 44.8 Wire-wrap terminal (1 1 mm) 24 22 48 2 5 48.5 17.1 When using the Wire-wrap Terminal, be sure to use the crect wires and peripheral devices. (The crect wires, bits and sleeves are shown in the table on the right.) Y92S-36 Lithium Battery (3 V) 24.5 dia. Wire Bit Sleeve Wrapped state AWG22 2-A 2-B Nmal AWG24 1-A 1-B Nmal AWG26 3-A 1-B Nmal 7.7 PCB-mounting Counters XR2A-2801-N 28-pin Socket Note: When using the Socket, use the PCB processing dimensions previously provided. 30

New H7E New H7E Precautions New H7E (Except f PCB-mounting Counter)! WARNING This product has a built-in lithium battery. Do not sht-circuit the + and terminals, charge, disassemble, defm, expose the battery to fire. The battery may explode (break), catch fire, cause liquid leakage.! Caution Do not use any battery other than the specified one (Y92S-36). Using another battery may cause liquid leakage breakage, resulting in malfunction injury.! Caution If a voltage other than the rated one is applied, internal elements may be damaged. Do not use the Counter in the following places: Locations subject to direct sunlight. Locations subject to crosive gases. Locations subject to dust. Befe Use An insulation sheet has been inserted to maintain the quality of the Totalizer in the event of a long period without use. Be sure to remove this sheet befe attempting to use the product. Remove the insulation sheet and press the Reset Key on the front panel of the Counter. (With the H7ER-N,-NV(-H),-NV1(-H), models, 0 0.0 will be displayed after 1 s.) Insulation Sheet Reset Input and Count/Timer Input The H7E operates using its built-in Battery. If the H7E is connected to a device that has +V and OUT terminals that are connected with a diode as shown in the circuit diagram, the circuit indicated by the arrow 1 2 will be fmed when the device is turned OFF. As a result, the H7E may be reset count by one. It is recommended that such devices not be connected to the H7E. Devices Reset Key Internal circuit H7E -N Count/Timer input reset input Switch settings on the Counter must be perfmed befe mounting it to a control panel. Do not use the Counter in the following locations: Locations subject to severe changes in temperature. Locations subject to condensation as the result of high humidity. Mounting Precautions f Flush Mounting Although the operating section is watertight (confming to NEMA4, IP66), rubber packing is provided to avoid water leakage through the gap between the Counter and panel cutout. Unless this rubber packing is tightly squeezed on, water may permeate inside the panel. Therefe, be sure to tighten the screws f fixing the Flush Mounting Bracket. (Excessive tightening may also defm the rubber packing.) Screw f the Flush Mounting Bracket The wider side must face the panel. Adapter If an excessive voltage is applied to the count/timer input reset input terminals, the internal elements may be damaged. Ensure that the following voltages are not exceeded: PNP/NPN universal voltage input model: 30 VDC AC/DC voltage input model: At count/timer input: 240 VAC (peak voltage: 338V) 240 VDC At reset input: 3 VDC (no-voltage input) No-voltage input model: 3 VDC Avoid wiring close to high-tension large-current lines. Do not remove the outer case when voltage is being applied to the power supply terminals the input terminals. The input f the H7E -NFV- is a high-impedance circuit and so influence from an induced voltage may result in malfunction. Therefe, when the input signal wiring is longer than 10 m (line capacitance of 120 pf/m, at room temperature), it is recommended that a CR filter a bleeder resist is connected. Panel 31

New H7E Count/Timer Input Reset Input to Me than One H7E Counter at a Time PNP/NPN Universal DC Voltage Input New H7E No-voltage Input and PNP/NPN Universal DC Voltage Input Models The operation of the Counter may be affected if the line voltage of the power supply exceeds 500 pf (about 10 m, with parallel wires of 2 x 2 mm). Keep all wires as sht as possible. When using shielded wire, line capacitance may occur. AC/DC Multi-voltage Input Models When connecting count/timer input from an SSR to the Counter that operates with AC/DC voltage input, use OMRON s G3TA-IA/ID SSR (f DC) whose leakage current is 0.1 ma max. connect a bleeder resist in parallel to the input circuit of the Counter. Leakage current: 0.1 ma max. Note: H (Reset ON) level must be 4.5 V minimum. 4.7 (kω)/n + V H = 4.7 (kω)/n + R No-voltage Input *Bleeder resist The voltage between terminals 1 and 2 must be 1.5 V maximum when the SSR is OFF. Backlight Power Supply To reduce variation in the brightness of the backlight when using me than one H7E with a backlight, use the same power supply f all the backlights. Note: 1. The leakage current of the transist used f input must be less than 1 µa. 2. The fward voltage of the diode must be as low as possible (i.e., 0.1 V maximum with an I F of 20 µa) so that the voltage between terminals 3 and 4 will be 0.5 V when the reset input is ON. Input and Power Supply No-voltage Input Models Do not impose voltage on the Counter if the Counter is a model that operates with no-voltage input, otherwise the internal circuit of the Counter may be damaged. Do not connect any single input signal in parallel to Counter models operating with no-voltage input and those operating with voltage input, otherwise the Counters may malfunction. When connecting a sens to the Counter that operates with no-voltage input, make sure that the sens has open collect output. Sens When connecting the DC power supply f the backlights, be sure to connect the polarities crectly. Input Verification with the H7ET Time Counter (When the time range is not set to 0s to 999h59m59s ) The decimal point of the LCD blinks every other second while an input signal is being applied. If the decimal point is not blinking, the input signal is not being received crectly. Check the input signal connections. Unit Label f Time Counter and Tachometer A unit label has been packed with the Counter. Use in accdance with the application. When connecting an open collect input from a transist to the Counter that operates with no-voltage input, make sure that the leakage current of the transist is 1 µa maximum. Battery Replacement Remove the wiring when replacing the Battery. Do not come in contact with any item to which high voltage is being applied. Doing so may result in electric shock. Befe changing the Battery, the person should ensure that they are not carrying any static electric charge. Procedure f replacing the Battery (refer to the diagrams below): 1. Using the tool, pry open the lift-tab on the case. (1) 2. Pull the body out of its outer case. (2) 3. Lift the Battery up by the edge and remove it. (3) When removing the Battery, do not come in contact with the display area any internal parts. 32

New H7E New H7E 4. Wipe the back of the new Battery befe inserting it. 5. Ensure that the + and terminals are crectly iented. 6. After replacing the Battery, re-insert the body into its case. (4) Check that the case is securely held in by the lift-tab. 7. Press the Reset Key befe use (not necessary f H7ER-N,-NV,-NV1). (5) Tool (2) (1) (1) (4) (3) Battery EN/IEC Standards The count timer input, reset input, and backlight power supply terminals of the no-voltage input PNP/NPN universal DC voltage input models (H7E -N,-N1, H7E -NV(-H),-NV1(-H)) are not isolated. A SELV power supply confming to Appendix H of IEC61010-1 should be used f the count timer input, reset input and backlight power supply terminals. A SELV power supply is a power supply f which the input and output have double reinfced insulation, and f which the output voltage is 30 Vrms with 42.4 V peak 60 VDC max. (Only the H7E -NV -H has a backlight.) The terminals f count timer input and reset input f AC/DC multi-voltage input models have basic insulation. Connect the reset input terminals to a device that does not have exposed current-carrying parts and has basic insulation f 240 VAC. Others If the indicat keeps flickering is OFF, the internal battery may be close to the end of its service life. In such a case, it is suggested that the battery be replaced. (5) Precautions PCB-mounting Counter Power Supply Use the power supply within the applicable range indicated by the following wavefm, while considering the ripple and voltage fluctuations of the circuit power source. Voltage 3.6 V 2.6 V Battery Replacement To prevent unwanted reset when replacing the battery, connect the new battery befe disconnecting the old one. Otherwise, the voltage supplied to the counter circuit drops, causing the present count value to reset. When designing the circuit board, providing two extra terminals f battery connection will make the switch must simpler. See the schematic diagram below: The H7E -N P changes its mode as shown below depending on the applied supply voltage. H7E -N P (V) 3.6 3 Approx. 2.6 Approx. 2.2 0 LCD Internal circuit operation Beyond supply voltage Looks darker Nmal operation Looks nmal Looks lighter No display Nmal operation No operation Applicable range Battery life guideline Wiring polarity must be carefully observed, in der to prevent permanent damage to the Counters. Exercise caution when inserting the Counter in the socket, to prevent reversed polarity. 33

New H7E New H7E Inputs Do not route the wiring of the count, timer, reset inputs in the vicinity of, in parallel to the wiring of high-voltage inductive load circuits (such as mots and relays). Also, keep the wiring as sht as possible. H7E -N P To Confm to EN/IEC Standards Input terminals have no insulation from power supply terminals. The power supply terminals must be supplied from a SELV source in accdance with IEC61010-1 Annex H. SELV (separated extra-low voltage) source is a power supply having double reinfced insulation between the primary and the secondary circuit and having output voltage of 30 V rms max. and 42.4 V peak max. 60 VDC max. Cleaning To prevent damage, the exteri of the Counter must not be exposed to ganic solvents (3.g. paint thinner benzine), strong alkalis, strong acids. Others No user-serviceable parts. Return to OMRON f all repairs. Be careful not to apply voltages exceeding the following values to the count, timer, reset terminals, otherwise the internal circuit may be damaged. No-voltage input: 3 VDC General Infmation The terminals are solder-plated. Finish soldering the terminals within 5 seconds, at a solder iron tip temperature of 250 C ± 10. Since the Counter is not flux-tight, do not use flux when soldering. Avoid automatic and dip soldering. Manually solder the Counter onto a PC board, and avoid cleaning as much as possible. When mounting the Counter on a PC board with components which consume higher current than the H7E -N P, observe the following precautions. 1. Minimize the wiring (less than 50 mm) from the H7E -N P to the power supply section. 2. Avoid placing the H7E -N P power, timer, counter, reset input circuit in parallel with circuits that consume large currents, particularly on the positive side. PC Board (Bad Example) PC Board (Good Example) H7E -N P Placed far away from the power supply. Large-currentconsuming components Large-currentconsuming components Wired in parallel with large-currentcarrying components. Bypass capacit H7E -N P Bypass capacit Power supply Power supply When using the Counter in an environment where the Counter is subject to frequent occurrences of vibration shock, when mounting the Counter facing downwards sideways, it is suggested that the Counter be directly soldered to a PCB instead of using sockets. 34