Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Similar documents
Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

DRG-SC Series Signal Conditioners

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DP2000 ORDERING GUIDE To Order MODEL NO.

Model 176 and 178 DC Amplifiers

Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems

Signal Conditioning Amplifier

ISOLATED 4-20 ma TRANSMITTERS

GE Fanuc IC695ALG600. Rx3i PacSystem

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

DIN Thermocouple Conditioner MODEL 5M14(V)

Industrial Modbus I/O Modules

FC Series Signal Conditioners

8248AU. 4-Ch Isolated Amplifier with Optional Bridge Conditioning FEATURES TYPICAL APPLICATIONS

Signal Conditioning Amplifier

User s Guide DRLP SERIES. Isolated DIN Rail Mount 2-Wire Trasmitters. Shop online at omega.com

Product Description. SIGnal Workbench. Programmable Signal Conditioning System

Product Information: ExTR Reference No. GB.FME.ExTR

SCM5B48 ACCELEROMETER INPUT MODULE USER S MANUAL

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

PACSystems* RX3i IC695ALG600

ni.com Sensor Measurement Fundamentals Series

This Errata Sheet contains corrections or changes made after the publication of this manual.

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

S200 I/O System Units

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

SB.5.1 MODEL STRAIN GAGE CONDITIONER INSTRUCTION MANUAL. Instrument Series

SCXI 8-Channel Isolated Analog Input Modules

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Series GLET Accessory for dataloggers series GL in modular enclosure

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Analog Isolation Amplifiers

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module

Economical Digital Indicators For Process and Electrical Measurement

Quantum I/O Modules. At a Glance. The following section provides information on the Quantum Input/Output (I/O) modules. What s in this Chapter?

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

High-precision process calibrator Model CED7000

Correlation of Voltage and Temperature Measurement

Analog Signal Conditioning Accessories

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit

TxBlock-USB Transmitter

MODEL AT-10 ANALOG TRANSMITTER

CONTA-ELECTRONICS. Converter Units

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox

PACSystems* RX3i IC695ALG600-DD

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

ADAM 4000/4100 Series

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Transmitters/Signal Conditioners

Modicon Momentum automation platform 0

P5201 Universal Programmable Transmitters with Galvanic Isolation

Technical Manual TRANSDUCER AMPLIFIER TYPE DR7AC. Doc. Ref CD2402K

Modular Smart Interfaces

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

Ouput Loop Powered Products Section C

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple,

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

Low Cost Instrumentation Amplifier AD622

ADAM Isolated DC Input/Output Signal Conditioning Module. User s Manual

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

Developer Techniques Sessions

USB-2404-UI Specifications

SensorLex 8B Isolated Analog Signal Conditioning Products. and D power. 7 to 34VDC 36V TVS, 1A Fuse, OV detection 35.5V max 6.

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

PIE 525. Diagnostic Thermocouple RTD & Milliamp Calibrator Operating Instructions. Practical Instrument Electronics

MODEL: W2TS. Mini-MW Series

MODEL: R30US4. Remote I/O R30 Series

Modular Controller. Key Features. Model P hotonics. Comprehensive laser diode protection features. Advanced 16-bit control technology

RTD), LM335 Voltage, or AD592 current. c. Constant TE Current (8350 only)

OPERATION MANUAL LDM-1000

QUAD PROGRAMMABLE FILTER/AMPLIFIERS For the and Signal Conditioning Systems

12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical

Industrial Interface The Signal Conditioning People

SPT. Description. Features. Site-Programmable, Isolated Temperature Transmitter

Two-Wire Programmable Transmitter for:

Isolated 4 to 20 ma Transmitters For Demanding Applications Thermocouples, RTD (Pt100) or Ohms, Millivolts, Milliamps, Volts

Data Acquisition Modules/ Distributed IO Modules

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

Analog Isolation Amplifiers

SLC 500 RTD/Resistance Input Modules

Transcription:

Introduction ISOLATD SIGNAL CONDITIONING can significantly increase your system reliability here's how: Linearizes Thermocouple and RTD signals Reduces the demands on the software to linearize the signal Produces a voltage or current that is directly usable by a display device Provides sensor excitation for RTD s, strain gages and transmitters Simplifies system design and reduces parts and cost Increases reliability liminates ground loops More accurate data acquisition Shortens system start up time Isolates the field from the computer Protects operators Protects the data acquisition hardware and the computer Minimizes errors caused by common mode voltage Amplifies the low level sensor signal outside of the electrically noisy computer chassis Minimizes or eliminates errors caused by electro-magnetic interference Provides over-voltage protection Protects equipment and personnel from improper wiring, power surges and other faults Provides convenient screw terminals for field wiring Simplifies installation Reduces troubleshooting and repair time Filters out unwanted noise Reduces noise from AC power lines, florescent lights, motors, etc. Mixes and matches many sensor types on one backplane Minimizes initial outlay Facilitates future expansion Customizes the full range of the module to match the sensor signal range Maximizes the resolution and accuracy of the reading over small signal spans Whether your analog application calls for maximum flexibility, low cost, or high performance, you ll find it in the WRC s broad line of analog signal conditioners. ach offers a unique signal conditioning solution. The 1781-7B Series is optimized for use in the process control industry. Features including redundant 2 V dc power, and 1 V rms isolation facilitate system design. High channel density applications are easily accommodated by the small size of the 7B Series module. Flexibility is a keynote of the 7B series these signal conditioners are the system designer s drop-in solution for interfacing to real-world signals. The WRC7 Series provides low-cost, low-isolation signal conditioning using the same pin-out and foot-print as the 1781-7B Series. Modules operate from regulated 2Vdc power supplies and provide nominal 6 V isolation. Functional Block Diagram of a typical measurement and control loop using signal conditioning subsystems. SNSOR OR TRANSMITTR PROCSS ACTUATOR (xample: valve) mv, V, Thermocouple, Strain Gage, RTD, Frequency, LVDT, -2 ma, AD9 INPUT MODUL Input Input modules modules accept accept real world real world analog analog inputs inputs and provide two high and provide high level analog level analog outputs outputs SYSTM INTRFAC (xample: SmartMux) The RTI Series) PC, MICRO- PLC, DCS, or MICRO- PUTR PUTR 2-2 ma, ma 2 ±1 ma V 1 V OUTPUT MODUL Output modules accept high level voltage inputs and provide process current or voltage outputs phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 1

1781-7B Series 1781-7B Series Input and Output Modules Features Accepts most process control input signals Powered current input provides 2 V for a transmitter Analog current output module Complete signal conditioning function: 12 V rms field wiring protection, filtering, amplification, 1 V rms galvanic isolation Pin compatible to industry standard solid-state relays Operates from 2 V dc (1 V dc to V dc) power Factory-calibrated accuracy to ±.1% Mix-and-match modularity 1781-7B Series Input and Output Modules The 1781-7B Series represents Western Reserve Control s ongoing commitment to provide cost-effective, isolation-based signal conditioning solutions for the process control industries. The 1781-7B Series is a family of modular, singlechannel, plug-in signal conditioning modules that accept inputs from a wide range of process control transducers and signals while providing high-level output voltages or process control currents. Performance Optimized for Featuring a maximum nonlinearity of ±.2% and factory calibration that guarantees an initial accuracy specification of ±.1%, the 1781-7B Series offers superior performance at a lower cost than existing multipurpose signal conditioners or in-house designs. Other family features include 16 db of commonmode rejection, 6 db of normal-mode rejection, up to 1 V rms of isolation, and 12 V rms of field wiring protection. Short circuit and input overvoltage protection are built-in and the proprietary isolation transformer circuit design of the 1781-7B Series provides for true channel-to-channel isolation. C Approval uropean C approvals MC directive compliant. Low voltage directive is not applicable. Products comply with NG11-1 (IC11.) Rated to Operate in the Industrial nvironment All 1781-7B Series modules are packaged in compact, rugged, 2.1" x 1.7" x.6" ( mm x 2 mm x 1 mm) plastic cases that readily accommodate high channel density applications. The modules are rated over the extended - C to 8 C industrial temperature range; and they may be operated in noncondensing, high humidity environments. 1781-7B Series modules can be removed and/or inserted into the backplane without damage to the modules when the power supplies are energized. Unregulated 2 V dc Linear Power Supplies The 1781-7B Series is rated for a nominal power supply input of 2 V dc; and, for maximum flexibility, it will accept supply voltages in the 1 V dc to phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 2

1781-7B Series V dc range. Consequently, system performance will not degrade with the use of unregulated supplies. Linear supplies are recommended for better noise rejection. Redundant power supply configurations are available. Hardware The 1781-7B Series is complemented by a full line of backplanes (1, -, 8-, 16- channel) and rackmount hardware. ach backplane contains screw terminals for field wiring connections, and a miniature cold junction compensation thermistor is installed under the screw terminal blocks for each channel. The 1781-7B Series simplified pinout ensures that this thermistor compensates the input signals for the thermocouple modules only. Consequently, any module type may be used in any channel on the backplane. Model Sensor Type 1781-7B21 dc V input 1781-7B22 dc V output 1781-7B dc mv/v input 1781-7B1 dc V input 1781-7B2 dc ma input 1781-7B dc V input 1781-7B/N 1 Ω platinum or nickle RTD 1781-7B dc ma with loop power: two-wire transmitter 1781-7B7 Isolated J, K, T,, R, S, B, N thermocouple 1781-7B9 dc ma output 1781-7B7 Isolated J, K, T,, R, S, B thermocouple 1781-7B Series Accuracy ±.1% Power Supply Requirements Configurability FM Approval Field Wiring Protection Isolation Voltage Common-Mode Rejection @ or 6Hz Normal-Mode Rejection @ or 6Hz Backplanes Rated Temperature Range Gain Adjustment Offset Adjustment Package Size Packaging Style Special Features Short Circuit Protection (Voltage Outputs) 1 V dc to V dc Factory Configured and Trimmed No Up to 12 V rms, continuous 1 V rms 12 db or better ( Hz modules only) 6 db 1,, 8, and 16 channel with built-in CJC sensor C to 8 C None Available to the User None Available to the User 1.66" x 2.11" x.6" (2.2mm x.6mm x 1.mm) Module Simple pinout, compact package Continuous short to ground phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com

1781-7B Series 1781-7B21 Isolated Analog Input Modules Module Input Range 1781-7B21 ±1 V Input Resistance - Normal 2 MΩ minimum Bandwidth, - db Hz 1781-7B Isolated Analog Input Modules Module Input Range 1781-7B-1 to 1 mv 1781-7B-2 to 1 mv 1781-7B- to 1 V 1781-7B- 1 to V 1781-7B-6 ±1 mv 1781-7B-7 ±1 mv 1781-7B-8 ± 1 V Input Resistance - Normal MΩ minimum Bandwidth, - db Hz 1781-7B1 Isolated Analog Input Modules Module Input Range 1781-7B1-1 to 1 V 1781-7B1-2 ± V 1781-7B1- ±1 V 1781-7B1- to V Input Resistance - Normal kω minimum Bandwidth, - db Hz V IN R T * 2 Surge Suppression and Protection NC R T is a backpanel option for current to voltage voltage conversion conversion using using either either WRC Dataforth P/N (2Ω) P/N *R T is a backpanel option for current to V V or a SCM7BR1 user-provided (2Ω) resistor a user provided resistor. 1 (1 pole) Iso-Chopper II ( pole) / Common Specifications Accuracy ±.1% span max., ±.% span typical Supply Voltage 1 to Vdc Current ma maximum Output Ranges Available Range Part # modifier xample to 1 V none 1781-7B-1 1 to V D 1781-7B-1D Includes the effects of repeatability, hysterisis and linearity Output range and supply current specifications are based on minimum output load resistance. Minimum output load resistance is calculated by V OUT2 /P where P is the Output ffective Available Power that guarantees output range, accuracy and linearity specifications. V OUT (1-V dc) 1781-7B22 Isolated Output (bipolar) Module Input Range Output Range 1781-7B22 ± 1 V ±1 V Output Resistance <1 Ω Input Resistance 2 MΩ minimum Accuracy* ±.1% span max. ±.% span typical Bandwidth, - db Hz Supply Voltage 19 to 29 Vdc Current** ma maximum * Includes the effects of repeatability, hysterisis and linearity ** Output range and supply current specifications are based on minimum output load resistance. Minimum output load resistance is calculated by V OUT2 /P where P is the Output ffective Available Power that guarantees output range, accuracy and linearity specifications. V IN /I IN R T * 2 NC Surge Suppression and Protection R *R T is a backpanel option for current to voltage T is a backpanel option for current to voltage conversion using either Dataforth WRC P/N P/N (2Ω, SCM7BR1.1%) (2Ω, or a user-provided.1%) or a resistor. provided resistor. **R R INT is the SCM7B2 only. INT is installed internal to the 1781-7B2 only. 1 R INT ** (1 pole) V V Iso-Chopper II ( pole) / V OUT (1-V dc) phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com

1781-7B Series 1781-7B2 Process Current Input Module Input Range 1781-7B2-1 to 2 ma 1781-7B2-2 to 2 ma Input Resistance - Normal <1 Ω 1781-7B Process Voltage Input Module Input Range 1781-7B-1 1 to V 1781-7B-2 to V Output Ranges Available Range Part # modifier xample to 1 V none 1781-7B-1 1 to V D 1781-7B-1D Input Resistance - Normal 2 MΩ I LOAD 1 Iso-Chopper II Surge Input Input Suppression (2 (2 pole) Protection/ Protection (1 (1 pole) Protection. and Conversion 2 (2 (2 pole) NC Common Specifications Accuracy* ±.1% span max., ±.% span typical Bandwidth, - db 1 Hz Supply Voltage 1 to Vdc Current** ma maximum V V / * Includes the effects of repeatability, hysterisis and linearity ** Output range and supply current specifications are based on minimum output load resistance. Minimum output load resistance is calculated by V OUT2 /P where P is the Output ffective Available Power that guarantees output range, accuracy and linearity specifications. V IN IN, I IN (19-29V (1-V dc) 1781-7B/N RTD Input Modules Module Input Accuracy* Non-** Range conformity 1Ω Pt (alpha =.8) 1781-7B-1 ±1 C ±.1% ±.% 1781-7B-2 to 1 C ±.2% ±.% 1781-7B- to 2 C ±.1% ±.% 1781-7B- to 1 C ±.1% ±.% 1781-7B- - C to C ±.1% ±.% 1Ω Ni (alpha =.672) 1781-7B-1N to C ±.% ±.12% 1781-7B-2N to 2 C ±.% ±.1% Lead Resistance ffect Sensor xcitation Current Bandwidth, - db Supply Voltage Current ±.2 C/Ω 2 µa Hx 1 to Vdc ma maximum Output Ranges Available Range Part # modifier xample to 1 V none 1781-7B-1 1 to V D 1781-7B-1D RTD Shield* NOT: For 2-wire operation, jumper the () and (x) connections on the backpanel term block. * Shield ground-tie shown for ungrounded RTD sensor configuration. 1 Surge Suppression, Protection, Lead Compensation, 2 (1 pole), and RTD Current Stimulus Linearization V V Iso-Chopper II * Includes the effects of repeatability, hysterisis and conformity. Accuracy is given as a maximum. The typical value is half the maximum. ** Nonconformity is calculated using the best-fit stright-line method. Nonconformity is given as a maximum. The typical value is half the maximum. Output range and supply current specifications are based on minimum output load resistance. Minimum output load resistance is calculated by V OUT2 /P where P is the Output ffective Available Power that guarantees output range, accuracy and linearity specifications. ( pole) / V OUT (1-V dc) phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com

1781-7B Series 1781-7B Transmitter Input Modules (2-Wire with Loop Power and Sense Resistor) Module Input Range Output Range 1781-7B-1D to 2 ma 1 to V 1781-7B-1 to 2 ma to 1 V Loop Voltage 2 Vdc* Bandwidth, - db 1 Hz Supply Voltage 18 to Vdc Current** 7 ma Output Ranges Available Range Part # modifier xample to 1 V none 1781-7B-1 1 to V D 1781-7B-1D 2-wire Transmitter Surge 1 Suppression, Protection 2 Surge Suppression, Protection NC V loop V V V loop & I-V Loop Supply Iso-Chopper II ( pole) / * 2 Vdc will be supplied to the loop for an open loop condition. Approximately 22 V to 16 V will be supplied for a corresponding MA to v2 ma input. Loop voltage is independant of supply voltage. ** Output range and supply current specifications are based on minimum output load resistance. Minimum output load resistance is calculated by V OUT2 /P where P is the Output ffective Available Power that guarantees output range, accuracy and linearity specifications. V OUT (18-V dc) 1781-7B7 Thermocouple Input Modules Model Number InputRange 1781-7B7-J-1-1 C to 76 C 1781-7B7-J-1 C to 2 C 1781-7B7-J-11 C to C 1781-7B7-J-12 C to 6 C Thermocouple 1781-7B7-J-1 C to 6 C 1781-7B7-K-2-1 C to 1 C 1781-7B7-K-2 C to C 1781-7B7-K-21 C to 6 C 1781-7B7-K-22 C to 12 C 1781-7B7-K-2 C to 18 C 1781-7B7-T- -1 C to C 1781-7B7-- C to 9 C 1781-7B7-R- C to 17 C 1781-7B7-S-6 C to 17 C 1781-7B7-B-7-1 C to 18 C Input Resistance - normal MΩ Accuracy* ±.1% span max, ±.% span typical Open Input Response Upscale Open Input Detection Time 1 s maximum Bandwidth, -db Hz Supply Voltage 1 to Vdc Current** ma maximum Shield** R T * *R T is a backpanel mounted NTC thermistor used as a cold junction compensation (CJC) sense element. **Shield ground-tie shown for ungrounded thermocouple configuration. 1 2 Surge Suppression, Protection, (1 pole), Open Detection and CJC V V Iso-Chopper II Output Ranges Available Range Part # modifier xample to 1 V none 1781-7B-1 1 to V D 1781-7B-1D ( pole) / V OUT (1-V dc) phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 6

1781-7B Series 1781-7B9 Process Current Output Module Input Range Output Range 1781-7B9-2 to 1 V to 2 ma 1781-7B9-2D 1 to V to 2 ma 1781-7B9-1 to 1 V -2 ma Output ffective Available Power 2 mw Output Current Limit 2 ma Accuracy *(see -7B7) ±.1% span max. ±.% span typical Bandwidth, - db 1 Hz Supply Voltage 18 to Vdc Current **(see -7B7) 7 ma maximum I LOAD 1 Iso-Chopper II Input (2 pole) (1 pole) 2 Surge Suppression Protection. and (2 pole) NC V V Protection/ Conversion / V IN, I IN (1-V dc) 1781-7B7 Linearized Thermocouple Input Module Input Range Accuracy 1781-7B7-J-1 C to 76 C ±.2% span 1781-7B7-J-2-1 C to C ±.% span 1781-7B7-K- C to 1 C ±.2% span 1781-7B7-K- C to 6 C ±.18% span 1781-7B7-T- C to C ±.8% span 1781-7B7-T-6-1 C to 2 C ±.7% span 1781-7B7--7 C to 9 C ±.% span 1781-7B7-R-8 C to 17 C ±.% span 1781-7B7-S-9 7 C to 17 C ±.2% span 1781-7B7-B-1 8 C to 18 C ±.% span 1781-7B7-N-11 2 C to 1 C ±.27% span Input Resistance - normal MΩ Accuracy* ±.1% span max, ±.% span typical Open Input Response Upscale Open Input Detection Time 1 s maximum Bandwidth, -db Hz Supply Voltage 1 to Vdc Current** ma maximum Thermocouple Shield** R T * *R T is a backpanel mounted NTC thermistor used as a cold junction compensation (CJC) sense element. **Shield ground-tie shown for ungrounded thermocouple configuration. 1 2 Surge Suppression, Protection, (1 pole), Open Detection and CJC V V Iso-Chopper II Output Ranges Available Range Part # modifier xample to 1 V none 1781-7B-1 1 to V D 1781-7B-1D ( pole) and Linearization / * Includes the effects of repeatability, hysterisis and linearity ** Output range and supply current specifications are based on minimum output load resistance. Minimum output load resistance is calculated by V OUT2 /P where P is the Output ffective Available Power that guarantees output range, accuracy and linearity specifications. V OUT (1-V dc) phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 7

Low-Cost WRC7 Series WRC s SmartMux, SmartMux-Lite, SmartMux-Plus and SmartPMux remote adapters all use 1781-7B and/or WRC7 series of analog I/O modules for signal conditioning. The 1781-7B modules provide cold-junction compensation; filtering; provide isolated sense currents; isolation; and amplification of the field signal to a standard -1 Vdc logic signal. Many applications do not require all of these features, especially point-to-point isolation. WRC7 Series of analog signal conditioning modules provide differential, signal conditioning in a manner which is compatible with WRC s SmartMux and SmartMux-Lite, SmartMux-Plus and SmartPMux. WRC7-9 Common Specifications: Package:.6 x 1.7 x 1.2 blue module case Pin-out: per standard/slim modules Power: 2Vdc /- 1% Isolation: when used with WRC SmartMux products, 6 V channel to channel; 1 V channel to network Common Mode Rejection: 12 db or better Normal Mode Rejection: 6 db Accuracy:.2% Logic side signal: - 1 Vdc Bandwidth: >2 KHz WRC7 SRIS WRC7 V DC Model Current WRC7-2 ma WRC7-1 2 ma WRC7-2 2 ma 1781-7- 2 ma 1781-7- 6 ma WRC7-6 2 ma WRC7-9 ma WRC7-9: ma Output Module WRC7-9-1-2 ma WRC7-9-2-2 ma Output Module WRC7-9-1 WRC7-9-2 Output Configuration 2 wire (&-) 2 wire (&-) Output Current Range - 2 ma - 2 ma ***Output Protection 12 VAC 12 VAC Output Power Avail. mw mw **Output Accuracy /-.2% /-.2% **Non-Linearity /-.2% /-.2% **Stability 1 ppm/c 1 ppm/c Output Compliance 1 V 1 V Voltage Limit Input Voltage Range to 1 V to 1 V Input Resistance >1 MΩ >1 MΩ * Typical @ 2C ** (of Span) *** Hi to Lo: V Lo to GND phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 8

WRC7-/1: Voltage Input Module WRC7--2-1 mv WRC7-- -1 V WRC7-- 1- V WRC7-1-1-1 V WRC7-1- - V WRC7--8 /- 1 V WRC7-1-2 /- V WRC7-1- /- 1 V WRC7-2: ma Input Module for externally powered field transmitters WRC7-2-1-2 ma WRC7-2-2-2 ma Input Module WRC7- WRC7-1 WRC7-2 Input Configuration 2 wire (&-) 2 wire (&-) 2 wire (&-) Input Resistance Normal 1M Ω 1M Ω 2 Ω Power Off 1M Ω 1M Ω 2 Ω Overload 1M Ω 1M Ω 2 Ω Input Protection Normal Mode 12 Vrms 12 Vrms ma Common Mode 12 Vrms 12 Vrms 12 Vrms Output Voltage Range to 1 V to 1 V to 1 V Output Resistance <1 Ω <1 Ω <1 Ω Output Protection Cont. Short Cont. Short Cont. Short Output Current Limit 1mA 1 ma 1 ma **Accuracy /-.2% /-.2% /-.2% ** Non-Linearity /-.2% /-.2% /-.2% ** Stability 1 ppm/c 1 ppm/c 1 ppm/c Frequency Response Hz Hz Hz * Typical @ 2C ** (of Span) *** Hi to Lo: V Lo to GND WRC7-167: -1 V Input or Output Module (pass through with signal clamping) phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 9

Sourcing Input Module WRC7- WRC7-6 WRC7-7 Input Resistance 1 MΩ 1 MΩ 1 MΩ xcitation Current Input.2 ma.2 ma.2 ma -Input.2 ma.2 ma.2 ma Lead resistance effect qual Resistance.1 Ω/Ω.1 Ω/Ω.1 Ω/Ω &- Lead Unequal Resistance 1 Ω/Ω of DR 1 Ω/Ω of DR 1 Ω/Ω of DR &- Lead Lead Resistance.2 Ω/Ω.2 Ω/Ω.2 Ω/Ω Maximum Lead 1 Ω 1 Ω 1 Ω Resistance (Total) Input protection to ground 1/8A Fuse 1/8A Fuse 1/8A Fuse Normal Mode ( to -) 12 VAC 12 VAC 12 VAC Common Mode(&- to ) 12 VAC 12 VAC 12 VAC **Accuracy /-.2% /-.2% /-.2% **Non-Linearity /-.2% /-.2% /-.2% **Stability 1 ppm/c 1 ppm/c 1 ppm/c Frequency Response Hz Hz Hz Output Voltage Range to 1V to 1V to 1V Output Resistance <1 Ω <1 Ω <1 Ω Output Protection Cont. Short Cont. Short Cont. Short Output Current Limit 1 ma 1 ma 1 ma WRC7-: RTD Input Module WRC7--1 ±1 C Pt WRC7--2-1 C Pt WRC7-- -2 C Pt WRC7-- -6 C Pt WRC7--N-1 - C Ni WRC7--C-1-12 C Cu WRC7-6: Potentiometer Input Module WRC7-6-1-1 Ω WRC7-6-2 - Ω WRC7-6- - 1 KΩ WRC7-6- - 1 KΩ WRC7-9-2-2 ma WRC7-7-1: Thermister Input Module 1K ohm NI * Typical @ 2C ** (of Span) *** Hi to Lo: V Lo to GND phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 1

1782-7BAS 1782-7BAS mounting board accepts one 1781-7B or WRC7 compatible module in a convenient DIN-rail mount package. A temperature sensor is mounted on board to provide cold junction compensation for thermocouple modules. Field connections are terminated with screw terminals. Logic side connections are terminated with screw terminations. MOUNTING DIMNSIONS. SCHMATIC DIAGRAM phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 11

1781-7B & 1782-7B The Panel-Mount 1781-7B and DIN-Rail Mount 1782-7B are -channel backplanes for use with the 1781-7B Series, WRC7 Series or compatible signal conditioner line. Both backplanes are powered by a user supplied 2 V dc power supply with primary and secondary recepticles for uninterrupted operation. One 2-pin D-type connector provides a connection to the logic side of the 1781-7B. Field-side terminations are achieved with screw terminations. For the 1781-7B, /" standoffs are provided for panel mounting. DIN-rail mounting is provided for the 1782-7B. The 1781-7B Mounting Board is fuse protected through F1. If the input supply voltage connection is reversed, diode DI will be forward biased to protect the modules. Provision is available for a user-provided, second, 2-pin, D-type connector. MOUNTING DIMNSIONS 1781-7B 1782-7B SCHMATIC DIAGRAM Note: P2 provided by user phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 12

1781-7B8 & 1782-7B8 The panel-mount 1781-7B8 and DIN-rail mount 1782-7B8 are 8-channel backplanes for use with the 1781-7B, WRC7, or compatible module line. Both backplanes are powered by a user supplied 2 V dc power supply with primary and secondary recepticles for uninterrupted operation. One 2-pin D-type connector provides a connection to the logic side of the 1781-7B8. Field-side terminations are achieved with screw terminations. For the 1781-7B8, /" standoffs are provided for panel mounting. DIN-rail mounting is provided for the 1782-7B8. The 1781-7B8 Mounting Board is fuse protected through F1. If the input supply voltage connection is reversed, diode DI will protect the modules. Provision is available for a user-provided second 2-pin D-type connector. MOUNTING DIMNSIONS 1781 7B8 1782 7B8 SCHMATIC DIAGRAM Note: P2 provided by user phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 1

1781-7B16 The 1781-7B16 is a 16-channel panel-mount backplane for use with the 1781-7B, WRC7, or compatible module line. The 1781-7B16 is powered by a user supplied 2 V dc power supply with primary and secondary recepticles for uninterrupted operation. One 2-pin D-type connector provides a connection to the logic side of the 1781-7B16. Field side terminations are achieved with screw terminations. /" standoffs are provided for panel mounting. DIN-Rail Mounting is not available. The 1781-7B16 Mounting Board is fuse protected through F1. If the input supply voltage connection is reversed, diode DI will protect the modules. Provision is available for a user-provided, second, 2-pin, D-type connector. MOUNTING DIMNSIONS SCHMATIC DIAGRAM Note: P2 provided by user phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 1

1781-STB-TC The 1781-STB-TC is a special analog termination board for use only with 1781-JxA SmartMux adapters. The 1781-STB-TC provides a low-cost means to provide 1 thermocouple measurements of the same type and range with a SmartMux. The 1781-STB-TC electrically looks like a 1781-B16 analog input mounting rack to the SmartMux, but it is dedicated to use with a single thermocouple type and range. Applications should be limited to those where isolation between thermocouples is not required. For those applications requiring multiple thermocouple types or isolation between thermocouples, consider the 1781-B or 1781-7B series of input modules. The 16th. thermocouple input channel is dedicated for cold junction compensation. APPLYING MOUNTING BOARD Number of Channels 1 differential thermocouples Plus one input for CJC Input Voltage Range /-V, /-1 mv, /- mv, /-2 mv, /- 1 mv, /- mv Input Over-voltage Protection /- V Input Resistance 1 Gig Ohm Gain Accuracy /-.% Input Offset /- 1 micro-volt Output Offset /- 2. milli-volts CJC Accuracy /- 1 degree C Low Pass Filter Frequency 8 Hz, removable by customer Common Mode Rejection 1 db Power Requirements V @ 2 ma Physical Dimensions 8.2" x 6.8" x 1.97" (2.9 cm x 17.27 cm x. cm) Operating Temperature Range to 6 degree C 1781-STB-TC phone: -7-6662 fax: -7-666 e-mail: sales@wrcakron.com www.wrcakron.com 1