A comparative study of noise in supercontinuum light sources for ultra-high resolution optical coherence tomography

Similar documents
Optical coherence tomography

Log-periodic dipole antenna with low cross-polarization

DBR based passively mode-locked 1.5m semiconductor laser with 9 nm tuning range Moskalenko, V.; Williams, K.A.; Bente, E.A.J.M.

Compensation of gain saturation in SOA-gates by interferometric Mach-Zehnder wavelength converters

Continuum White Light Generation. WhiteLase: High Power Ultrabroadband

Multi-mode to single-mode conversion in a 61 port photonic lantern

Fiber-wireless links supporting high-capacity W-band channels

Characterization of a fibre optic swept laser source at 1!m for optical coherence tomography imaging systems

Beyond 100 Gbit/s wireless connectivity enabled by THz photonics

Limitations in distance and frequency due to chromatic dispersion in fibre-optic microwave and millimeter-wave links

60 MHz A-line rate ultra-high speed Fourier-domain optical coherence tomography

Separation of common and differential mode conducted emission: Power combiner/splitters

Citation (APA): Markos, C. (2017). Photo Contest Optics & Photonics News, 28(12), DOI: /OPN

High precision planar waveguide propagation loss measurement technique using a Fabry-Perot cavity

Short Ring Cavity Swept Source Based on a Highly Reflective Chirped FBG

some aspects of Optical Coherence Tomography

An image-based method for objectively assessing injection moulded plastic quality

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Designing for Femtosecond Pulses

Supercontinuum based mid-ir imaging

Novel Electrically Small Spherical Electric Dipole Antenna

Low-Profile Fabry-Pérot Cavity Antenna with Metamaterial SRR Cells for Fifth Generation Systems

CMOS Current-mode Operational Amplifier

Photoacoustic imaging using an 8-beam Fabry-Perot scanner

Encoding of inductively measured k-space trajectories in MR raw data

A high-speed CMOS current op amp for very low supply voltage operation

Glaucoma Advanced, LAbel-free High resolution Automated OCT Diagnostics GALAHAD

A miniature all-optical photoacoustic imaging probe

S.R.Taplin, A. Gh.Podoleanu, D.J.Webb, D.A.Jackson AB STRACT. Keywords: fibre optic sensors, white light, channeled spectra, ccd, signal processing.

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Compact microstrip bandpass filter with tunable notch

Imaging the Subcellular Structure of Human Coronary Atherosclerosis Using 1-µm Resolution

Simultaneous measurement of two different-color ultrashort pulses on a single shot

Scanning laser Doppler vibrometry

Isolator-Free 840-nm Broadband SLEDs for High-Resolution OCT

Accurate Antenna Models in Ground Penetrating Radar Diffraction Tomography

University of Huddersfield Repository

Evaluation of the Danish Safety by Design in Construction Framework (SDCF)

Self-Resonant Electrically Small Loop Antennas for Hearing-Aids Application

Dynamic range of low-voltage cascode current mirrors

A Novel SFG Structure for C-T Highpass Filters

Published in: Proceedings of the 20th Annual Symposium of the IEEE Photonics Benelux Chapter, November 2015, Brussels, Belgium

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS

Optimization of supercontinuum generation in photonic crystal fibers for pulse compression

High-speed spectral-domain optical coherence tomography at 1.3 µm wavelength

Integrated photonic circuit in silicon on insulator for Fourier domain optical coherence tomography

Bandwidth limitations in current mode and voltage mode integrated feedback amplifiers

Talbot bands in the theory and practice of optical coherence tomography

LMT F14. Cut in Three Dimensions. The Rowiak Laser Microtome: 3-D Cutting and Imaging

Spectral beam combining of a 980 nm tapered diode laser bar

The current distribution on the feeding probe in an air filled rectangular microstrip antenna

A Multifrequency Radiometer System

Back seeding of picosecond supercontinuum generation in photonic crystal fibres

Properties of LED considering museum lighting

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

Further development of synthetic aperture real-time 3D scanning with a rotating phased array

Microwave Radiometer Linearity Measured by Simple Means

WDM Transmitter Based on Spectral Slicing of Similariton Spectrum

Non-contact Photoacoustic Tomography using holographic full field detection

An area efficient low noise 100 Hz low-pass filter

PROCEEDINGS OF SPIE. A novel fiber laser development for photoacoustic microscopy

A Passive X-Band Double Balanced Mixer Utilizing Diode Connected SiGe HBTs

Effect of ohmic heating parameters on inactivation of enzymes and quality of not-fromconcentrate

Kit for building your own THz Time-Domain Spectrometer

A Waveguide Transverse Broad Wall Slot Radiating Between Baffles

Spectral domain optical coherence tomography with balanced detection using single line-scan camera and optical delay line

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI)

Axsun OCT Swept Laser and System

Transmitting Performance Evaluation of ASICs for CMUT-Based Portable Ultrasound Scanners

Simultaneous acquisition of the real and imaginary components in Fourier domain optical coherence tomography using harmonic detection

Evaluation of fibre twisting angle and composite properties

Photonic Crystal Fiber Interfacing. In partnership with

A 243mJ, Eye-Safe, Injection-Seeded, KTA Ring- Cavity Optical Parametric Oscillator

Gabor fusion technique in a Talbot bands optical coherence tomography system

Performance Analysis of Chromatic Dispersion Compensation of a Chirped Fiber Grating on a Differential Phase-shift-keyed Transmission

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Towards Ultrahigh Speed Impulse Radio THz Wireless Communications

Yellow nanosecond sum-frequency generating optical. parametric oscillator using periodically poled LiNbO 3

System Level Design of a Continuous-Time Delta-Sigma Modulator for Portable Ultrasound Scanners

Fiber-optic Michelson Interferometer Sensor Fabricated by Femtosecond Lasers

Modifications of the coherence radar for in vivo profilometry in dermatology

J-KAREN-P Session 1, 10:00 10:

A Practical FPGA-Based LUT-Predistortion Technology For Switch-Mode Power Amplifier Linearization Cerasani, Umberto; Le Moullec, Yannick; Tong, Tian

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

Investigation of a Hybrid Winding Concept for Toroidal Inductors using 3D Finite Element Modeling

Testing with Femtosecond Pulses

Optimizing Inductor Winding Geometry for Lowest DC-Resistance using LiveLink between COMSOL and MATLAB

The Danish Test Facilities Megavind Offspring

A 2GHz, 17% tuning range quadrature CMOS VCO with high figure of merit and 0.6 phase error

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

A 7-13 GHz low-noise tuned optical front-end amplifier for heterodyne transmission system application

Investigating Enhancement Mode Gallium Nitride Power FETs in High Voltage, High Frequency Soft Switching Converters

Design and Measurement of a 2.45 Ghz On-Body Antenna Optimized for Hearing Instrument Applications

Silica-waveguide thermooptic phase shifter with low power consumption and low lateral heat diffusion

How to build an Er:fiber femtosecond laser

All-Optical Signal Processing and Optical Regeneration

Theory and Applications of Frequency Domain Laser Ultrasonics

SUPPLEMENTARY INFORMATION

Transcription:

Downloaded from orbit.dtu.dk on: Oct 05, 2018 A comparative study of noise in supercontinuum light sources for ultra-high resolution optical coherence tomography Maria J., Sanjuan-Ferrer,; Bravo Gonzalo, Ivan; Bondu, Magalie; Engelsholm, Rasmus Dybbro; Feuchter, Thomas; Moselund, Peter M.; Leick, Lasse; Bang, Ole; Podoleanu, Adrian Published in: Proceedings of SPIE Link to article, DOI: 10.1117/12.2251500 Publication date: 2017 Document Version Publisher's PDF, also known as Version of record Link back to DTU Orbit Citation (APA): Maria J., S-F., Bravo Gonzalo, I., Bondu, M., Engelsholm, R. D., Feuchter, T., Moselund, P. M.,... Podoleanu, A. (2017). A comparative study of noise in supercontinuum light sources for ultra-high resolution optical coherence tomography. In Proceedings of SPIE (Vol. 10056). [100560O] SPIE - International Society for Optical Engineering. (Proceedings of SPIE, the International Society for Optical Engineering, Vol. 10056). DOI: 10.1117/12.2251500 General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

A comparative study of noise in supercontinuum light sources for ultra-high resolution Optical Coherence Tomography M. Maria* a, b, I. B. Gonzalo c, M. Bondu a, b, R. D. Engelsholm c, T. Feuchter a, P. M. Moselund a, L. Leick a, O. Bang c and A. Podoleanu b a NKT Photonics A/S, Blokken 84, DK-3460 Birkerod, Denmark b Applied Optics Group, School of Physical Sciences, University of Kent, Canterbury CT2 7NH, United Kingdom c DTU Fotonik, Danmarks Tekniske Universitet, Ørsteds Plads 343, DK-2800 Kongens Lyngby, Denmark Keywords: Optical Coherence Tomography, Supercontinuum, Noise. 1. INTRODUCTION Supercontinuum (SC) light is a well-established technology, which finds applications in several domains ranging from chemistry to material science and imaging systems [1-2]. More specifically, its ultra-wide optical bandwidth and high average power make it an ideal tool for Optical Coherence Tomography (OCT). Over the last 5 years, numerous examples have demonstrated its high potential [3-4] in this context. However, SC light sources present pulse-to-pulse intensity variation that can limit the performance of any OCT system [5] by degrading their signal to noise ratio (SNR). To this goal, we have studied and compared the noise of several SC light sources and evaluated how their noise properties affect the performance of Ultra-High Resolution OCT (UHR-OCT) at 1300 nm. We have measured several SC light sources with different parameters (pulse length, energy, seed repetition rate, etc.). We illustrate the different noise measurements and their impact on a state of the art UHR-OCT system producing images of skin. The sensitivity of the system was higher than 95 db, with an axial resolution below 4µm. 2. SETUP Fig. 1(a) describes the UHR-OCT system used in this study. It consists in a Michelson interferometer illuminated by an ultra-broadband optical source SC combined with a broadband filter (Super K Gauss NKT Photonics A/S) providing an optical bandwidth of several hundred nm around a central wavelength of 1270 nm at different repetition rate. The interferometer itself contains a broadband directional coupler splitting the light towards both, a reference and a sample arm respectively. The sample arm consists of a reflective collimator (C1), a pair of galvo-scanners (XY) and a scanning lens (OBJ) with a 10 magnification and a focal length of 18 mm (Thorlabs LSM 02). The reference arm is made of a reflective collimator (C1), a block of glass matching the dispersion of the scanning lens (Thorlabs LSM 02DC), a neutral density filter and a flat mirror (FM). The detection is performed by an ultra-broadband spectrometer with a bandwidth of 400 nm centered at 1270 nm (Wasatch Photonics - Cobra 1300). It employs an InGaAs camera operated at a line rate of 40 khz (Goodrich GL2048L). Fig.1(b) describes the typical design used for SC generation. Light from a seed laser at 1060 nm is amplified through fiber based amplification in order to reach typical power of few watts. Then, the light is injected into a highly non-linear fiber (HNLF), generally a photonics crystal fiber (PCF), in order to generate a supercontinuum of wavelengths from ~ 500 nm to 2.4 μm. An example of spectrum from a SC is presented in Fig. 1(c). As a comparison, we propose to investigate the use of different SC sources for UHR-OCT at a central wavelength of 1300 nm. Table 1 presents the seed laser parameters used to generate 3 different SCs which are then used to illuminate the UHR-OCT setup. Two SCs are based on a seed pulse of 7 ps and a repetition rate of 80 or 320 MHz, a third SC is based on a longer seed pulse of 27 ps but with a lower repetition rate of 20 MHz. Design and Quality for Biomedical Technologies X, edited by Ramesh Raghavachari, Rongguang Liang, Proc. of SPIE Vol. 10056, 100560O 2017 SPIE CCC code: 1605-7422/17/$18 doi: 10.1117/12.2251500 Proc. of SPIE Vol. 10056 100560O-1

Supercontinu light source Supercontinuum light source Ultra- Broadband Spectrometer 180 160 140 120 - Seed Laser 100-80 - 0 400 600 800 I000 1200 1400 1600 1800 2000 220o 2400 w.vwi.vu Inm] Fig. 1: System description: (a) Schematic of the UHR-OCT system with DC: directional coupler, C1: collimators, PC: polarization controller, XY scanner a pair of galvo-scanners, OBJ: objective, Disp.C: dispersion compensation block, ND Filter: neutral density filter, M1: flat mirror. (b) Typical SC design. (c) Example of SC output spectrum. 40 20 Supercontinuum ID Seed Pulse Length (ps) Seed Repetition Rate ( MHz) Super K Extreme 7 80 Super K Extreme 7 320 SC 27 20 Table. 1: SC s seed laser parameter for comparison. 3. RESULTS The first measurement presented is the sensitivity observed when using the 3 SC sources previously described. The sensitivity is obtained by measuring the signal to noise ratio obtained when a neutral density filter and a flat mirror are used in the sample arm of the UHR-OCT set-up. In order to describe the system specifications under similar conditions to those used in imaging, a power of 4 mw is used in the sample arm and in order to avoid the saturation of the camera due to the reflection of the mirror in the sample arm, a neutral density filter is used with an optical density of 2 (OD=2). Fig. 2(a-c) shows the sensitivity decays with depth for the 3 SC sources. All three SCs present a sensitivity higher than 85 db for a depth up to 1 mm. However, it is noticeable that the larger the repetition rate, the higher the sensitivity. This may be explained based on the fact that by increasing the repetition rate, the relative intensity noise from the optical source is Proc. of SPIE Vol. 10056 100560O-2

reduced. The overall drop of sensitivity over the depth range is mainly due to the spectrometer itself and not to the source, this effect can be seen in Fig. 2(c) where the drop profiles of sensitivity with depth is similar to the two SC sources. 110 100 W 80 "51 70 m 0 60 00 40 30 no a) tdo b) 93 9 80 7D r%z a0 50-40 0 200 400 600 800 1000 1200 1400 1800 1800 2000 Depth [pm] W 0 200 400 600 BOO 1000 1200 1400 1600 1900 2000 Depth [pm] 110 100 90 100 c) d) 95 + ç+ - Super K R80MHZ -I-Super K Externe.RDiOMHe Super K-R20MHz á_ BO 5 70 9? (0 60 Fo" 90' e t as N 50 30o 200 400 600 800 1000 1200 14W 1600 1800 2000 Depth [pm] 75 5W 1000 Depth [Pre) Fig.2: Sensitivity measurements of the three SC sources: (a) Sensitivity peak for Super K Extreme R = 320 MHz. (b) Sensitivity peak for Super K Extreme R = 80 MHz. (c) Sensitivity peak for the SC with R = 20 MHz. (d) Sensitivity curves for all SC. The sensitivity profiles in Fig. 2(d) impact the quality of images differently, as can be noticed on the images shown in Fig. 3 and Fig. 4, of B-scans measured from a volunteer skin and finger nail. An optical power of 4 mw is applied on the sample. The sets of images have been recorded at times separated by several hours. This is explaining why the images do no display exact the same part of tissue. The images obtained using the higher repetition rate SC exhibit a darker background in comparison with the images produced with the lower repetition rate SC source. The background noise affects the contrast and hence, the overall image quality. 1500 Proc. of SPIE Vol. 10056 100560O-3

a) b) Fig. 3: OCT B-scans of human skin taken in-vivo from a volunteer s finger. (a) Super K Extreme R = 320 MHz. (b) Supercontinuum R = 20 MHz. Proc. of SPIE Vol. 10056 100560O-4

a) b) Fig. 4: OCT B-scans of human nail taken in-vivo from a volunteer s finger. (a) Super K Extreme R = 320 MHz. (b) Supercontinuum R = 20 MHz. 4. CONCLUSION In conclusion, we have investigated the effect of the laser seed pulse repetition rate on the noise of a SC for UHR- OCT at 1300 nm. Differences up to 5 db on the OCT sensitivity are observed when the repetition rate is varied from 20 MHz to 320 MHz. Images of human skin and finger nail are acquired in-vivo and present a clear difference in background darkness which confirm the sensitivity differences. Proc. of SPIE Vol. 10056 100560O-5

5. ACKNOWLEDGMENTS MM, TF, PM, LL and AP acknowledge support from the European Industrial Doctorate UBAPHODESA, FP7-PEOPLE- 2013-ITN 607627. IB, RE and OB acknowledge the support of the Innovationsfonden SHAPEOCT. AP acknowledge the support of ERC (http://erc.europa.eu) COGATIMABIO 249889. AP is also supported by the NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and the UCL Institute of Ophthalmology and the Royal Society Wolfson Research Merit Award. 6. REFERENCES 1. S. Liukaityte, M. Lequime, M. Zerrad, T. Begou, and C. Amra, Broadband spectral transmittance measurements of complex thin-film filters with optical densities of up to 12, Opt. Express. 40 (14), 3225-3228 (2015). 2. F. LaRocca, D. Nankivil, S. Farsiu, and J. A. Izatt, True color scanning laser ophthalmoscopy and optical coherence tomography handheld probe,, Biomed. Opt. Express. 5 (9), 3204-3216 (2014). 3. X. Shu, M. Bondu, B. Dong, A. Podoleanu, L. Leick, and H. F. Zhang, Single all-fiber-based nanosecond-pulsed supercontinuum source for multispectral photoacoustic microscopy and optical coherence tomography, Opt. Letters. 41 (12), 2743-2746 (2016). 4. S. Chen; X. Shu; J. Yi; A. Fawzi; H. F. Zhang, Dual-band optical coherence tomography using a single supercontinuum laser source, J. Biomed. Opt. 21 (6), 066013 (2016).5. K. L. Corwin, N. R. Newbury, J. M. Dudley, S. Coen, S. A. Diddams, K. Weber, and R. S. Windeler, Fundamental Noise Limitations to Supercontinuum Generation in Microstructure Fiber, Phys. Rev. Lett. 90, 113904 (2003). Proc. of SPIE Vol. 10056 100560O-6