Lab #11 Rapid Relaxation Part I... RC and RL Circuits

Similar documents
Lab 7 - Inductors and LR Circuits

Equipment and materials to be checked out from stockroom: ECE 2210 kit, optional, if available. Analog BK precision multimeter or similar.

Physics 310 Lab 2 Circuit Transients and Oscilloscopes

Lab E5: Filters and Complex Impedance

ET1210: Module 5 Inductance and Resonance

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 10. Electronic Circuits

Introduction to oscilloscope. and time dependent circuits

Lab E5: Filters and Complex Impedance

Lab 6 - Inductors and LR Circuits

Physics 120 Lab 1 (2018) - Instruments and DC Circuits

total j = BA, [1] = j [2] total

AC CURRENTS, VOLTAGES, FILTERS, and RESONANCE

Laboratory Exercise 6 THE OSCILLOSCOPE

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

Experiment #2 Half Wave Rectifier

The oscilloscope and RC filters

Physics 323. Experiment # 1 - Oscilloscope and Breadboard

How to Setup and Use an Oscilloscope

UNIVERSITY OF TECHNOLOGY, JAMAICA School of Engineering -

Lab 9 - INTRODUCTION TO AC CURRENTS AND VOLTAGES

ENG 100 Lab #2 Passive First-Order Filter Circuits

INTRODUCTION TO AC FILTERS AND RESONANCE

Physics 334 Notes for Lab 2 Capacitors

11. AC-resistances of capacitor and inductors: Reactances.

Experiment 9 AC Circuits

Lab 8 - INTRODUCTION TO AC CURRENTS AND VOLTAGES

PHY152 Experiment 4: Oscillations in the RC-Circuits (Measurements with an oscilloscope)

Lab #2: Electrical Measurements II AC Circuits and Capacitors, Inductors, Oscillators and Filters

Oscilloscope Measurements

resistor box inductor 3 BNC to banana + V L

Lab 3: AC Low pass filters (version 1.3)

EXPERIMENT 8: LRC CIRCUITS

RC and RL Circuits. Figure 1: Capacitor charging circuit.

Lab 1: Basic RL and RC DC Circuits

Parts to be supplied by the student: Breadboard and wires IRLZ34N N-channel enhancement-mode power MOSFET transistor

Exp. #2-6 : Measurement of the Characteristics of,, and Circuits by Using an Oscilloscope

I. RC circuit Charge and Discharge : Theoretical Results

UNIVERSITY OF TECHNOLOGY, JAMAICA SCHOOL OF ENGENEERING. Electrical Engineering Science. Laboratory Manual

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

Experiment 5 The Oscilloscope

DC and AC Circuits. Objective. Theory. 1. Direct Current (DC) R-C Circuit

B. Equipment. Advanced Lab

Class #7: Experiment L & C Circuits: Filters and Energy Revisited

Lab #5 Steady State Power Analysis

The Digital Oscilloscope and the Breadboard

2 Oscilloscope Familiarization

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

Filters And Waveform Shaping

ELECTRIC CIRCUITS CMPE 253 DEPARTMENT OF COMPUTER ENGINEERING LABORATORY MANUAL ISHIK UNIVERSITY

Physics 309 Lab 3 Bipolar junction transistor

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

Electric Circuit Fall 2017 Lab10. LABORATORY 10 RLC Circuits. Guide. Figure 1: Voltage and current in an AC circuit.

On-Line Students Analog Discovery 2: Arbitrary Waveform Generator (AWG). Two channel oscilloscope

Simple Oscillators. OBJECTIVES To observe some general properties of oscillatory systems. To demonstrate the use of an RLC circuit as a filter.

Ph 3455 The Franck-Hertz Experiment

ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM)

Chapter 1: DC circuit basics

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

EE Laboratory 4 - First Order Circuits *** Due in recitation on the week of June 2-6, 2008 ***

Experiment 1: Instrument Familiarization (8/28/06)

Oscilloscope and Function Generators

Exponential Waveforms

LAB 7: THE OSCILLOSCOPE

ECE 53A: Fundamentals of Electrical Engineering I

Experiment 1: Instrument Familiarization

Physics 310 Lab 4 Transformers, Diodes, & Power Supplies

Sirindhorn International Institute of Technology Thammasat University

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement

#8A RLC Circuits: Free Oscillations

POLYTECHNIC UNIVERSITY Electrical Engineering Department. EE SOPHOMORE LABORATORY Experiment 3 The Oscilloscope

Experiment 8: An AC Circuit

Experiment 9: AC circuits

Laboratory 3 (drawn from lab text by Alciatore)

Bring your textbook to lab.

Lab #7: Transient Response of a 1 st Order RC Circuit

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

Chapter 1: DC circuit basics

Sound Wave Measurements using an Oscilloscope and Waveform Generator

ECE212H1F University of Toronto 2017 EXPERIMENT #4 FIRST AND SECOND ORDER CIRCUITS ECE212H1F

10: AMPLIFIERS. Circuit Connections in the Laboratory. Op-Amp. I. Introduction

Purpose: 1) to investigate the electrical properties of a diode; and 2) to use a diode to construct an AC to DC converter.

Lab #2: Electrical Measurements II AC Circuits and Capacitors, Inductors, Oscillators and Filters

Physics 364, Fall 2014, reading due your answers to by 11pm on Sunday

Experiment 2: Transients and Oscillations in RLC Circuits

Physics Electronics Temple University, Fall C. J. Martoff, Instructor

Faculty of Engineering, Thammasat University

E-200D ALIGNMENT. See the end of the procedure for the location of the calibration points. EQUIPMENT REQUIRED

Resonance in Circuits

EE2210 Laboratory Project 1 Fall 2013 Function Generator and Oscilloscope

AC CIRCUITS. Part 1: Inductance of a Coil. THEORY: If the current in a resistor R, a capacitor C, and/or an inductor L is given by:

Lab 10 - INTRODUCTION TO AC FILTERS AND RESONANCE

10 Electromagnetic Interactions

Lab Equipment EECS 311 Fall 2009

Virtual Lab 1: Introduction to Instrumentation

Laboratory Project 1a: Power-Indicator LED's

University of Utah Electrical Engineering Department ECE 2100 Experiment No. 2 Linear Operational Amplifier Circuits II

AC Circuits. "Look for knowledge not in books but in things themselves." W. Gilbert ( )

PHYS 235: Homework Problems

Lab 4: Transmission Line

Basic Electronics Learning by doing Prof. T.S. Natarajan Department of Physics Indian Institute of Technology, Madras

Transcription:

Rev. D. Day 10/18/06; 7/15/10 HEFW PH262 Page 1 of 6 Lab #11 Rapid Relaxation Part I... RC and RL Circuits INTRODUCTION Exponential behavior in electrical circuits is frequently referred to as "relaxation", particularly for circuits which make use of some exponential property for control of timing, eg. a "relaxation oscillator" makes use of the exponential charging of an RC circuit to control some repetitive process such as the flashing of warning lights at construction sites. In an earlier experiment, the exponential behavior of a resistor-capacitor combination was investigated by making time measurements with a stopwatch, using fairly large values of both R and C in order to get a sufficiently slow variation. In this connection, it should be recalled that the time constant for an RC circuit is given by the product RC, and hence can be increased by increasing either of these quantities. In a resistance-inductance combination, on the other hand, the time constant is given by the ratio L/R. Attempts to obtain L values large enough to allow direct measurement of exponential behavior by the stopwatch technique are therefore likely to fail because of the simultaneous increase in resistance that will occur as more windings are added to the inductor. (It is possible to obtain very long RL time constants by using superconducting technology to greatly reduce the resistance, but that is somewhat beyond the scope of this lab.) In this experiment, the ability to display rapidly varying electrical signals on an oscilloscope will be used to allow the investigation of rapid exponential behavior of both RC and RL circuits. These procedures will then be extended to investigate the relaxation behavior of a series circuit containing all three components -- R, L, and C. The graph in Figure 1 shows an exponential function starting at a vertical coordinate of 8 and decaying to zero. If we assume the horizontal axis to represent time, the half-life can be measured as the time required to fall from 8 to 4 on the vertical scale, which is 2 divisions on this axis. It is extremely important to note that it takes this same amount of time to get from any vertical value on the graph to a point which is 1/2 of the starting value. From 6 to 3, 4 to 2, 2 to 1, 1 to 1/2 all require 2 horizontal divisions. Thus, in order to measure half-life, any starting point will do, but it is absolutely necessary to be able to see enough of the curve to locate the asymptote in order to establish the zero level. The phrase "zero level" above is in quotes because of the possibility that the circuit under investigation might be asymptotically approaching some constant value other than zero. For example, it has been previously shown that when an RC circuit is initially connected to a battery, the charge on the capacitor will grow toward its equilibrium value with an exponential time constant identical to that which governs its decay, ie. the product RC. In this experiment both growing and decaying signals will be investigated, and it will be discovered that all such signals within the same circuit share the same half-life.

Rev. 7/15/10 HEFW Lab #11 Rapid Relaxation, Part I RC and RL Circuits Page 2 of 6 THEORY For a complete theoretical treatment you should consult your textbook. The following is a brief summary of the essential points. The (V, I, t) and (V, Q, t) dependencies for the three types of circuit components are shown below. V R RI dq R Q V C ; C I dv C C V L di L 2 d Q L 2 In most physics textbooks, the preferred variable is the set (V, Q, t). Unfortunately, most of the rest of the world uses the set (V, I, t) since V and I and t are readily measured with DMM s or oscilloscopes. In this lab we are going to investigate both an RC and an RL circuit driven by a square wave source. THE METHOD This discussion will be presented specifically for the RC circuit, and the variations that are needed for the RL case will be mentioned at the end. Rather than the batteries and switches customarily shown in textbook illustrations of RC circuits, a square wave generator will be used in order to accomplish the alternation between charging and discharging rapidly enough to provide a continuous signal for display on the oscilloscope. A square wave "instantaneously" switches back and forth, at a steady frequency, between a plus voltage and zero voltage (or ground). When connected in series with an RC pair, this changing voltage has the effect of trying to instantaneously reverse the charge on the capacitor at this same frequency but, since the charge can move only as fast as allowed by the resistor, it can't keep up with the square wave. The voltage across the capacitor will therefore resemble Figure 2, showing exponential behavior first in one direction and then in the other. (B) (A) (B) (A) 1. RC Circuit Theory (A) If V s = 0 (square wave at zero value) then dv C / + V/R C = 0 and V C (t) = V o e -t/rc Remember that the initial condition is V C (t=0)=v 0, due to the previous charge cycle. (B) If V s = V o (square wave at V o value) then dv C / + V/R C = V o /R C and V C (t) = V o [1-e -t/rc ] Recall that the initial condition for the capacitor voltage is V C (t = 0) = 0, due to the previous discharge cycle.

Rev. 7/15/10 HEFW Lab #11 Rapid Relaxation, Part I RC and RL Circuits Page 3 of 6 (C) Sketch of both solutions 2. RL Circuit Theory KVL -V s + V L +V R = 0 V L +V R = V s L(dI/) + IR = V s so di/ + (R/L)I = V s /L (A) When V s = 0 then I(t) = I o e -(R/L)t (B) When V s = V o then I(t) = I o [1-e -(R/L)t ] But with an oscilloscope you measure V(t), not I(t). So multiply both sides of the I(t) equations by R and: (C) Sketch of both solutions V R (t) = V o e -(R/L)t (discharge) V R (t) = V o [1-e -(R/L)t ] (charge) Just like part (C) in section 1 above, except you are looking at V S (t) and V R (t). EQUIPMENT... Scope Probes Special purpose cables, called probes, are used when connecting an oscilloscope into an operating circuit. These cables have the obvious function of providing clip-on connections small enough to hook onto the component under study without interfering with other circuit elements. They also do a few other things that are not so immediately evident. As with any measuring device, one of the principal concerns in scope measurements is to avoid changing the signal being measured in the act of measuring it. Since scopes are frequently used to examine rapidly changing signals of complicated form, some care must be taken so that the resistive and reactive properties of the connecting cables do not distort the shape of the signal. A good probe contains compensating circuitry to exactly cancel the effects of that particular length of that particular type of co-ax cable. This circuitry may be located near the tip of the probe or, for smaller diameter probe cables, in a small box at the scope end. An additional function of probe compensation is to avoid reflections of the signal which could produce "ghosts" on the display.

Rev. 7/15/10 HEFW Lab #11 Rapid Relaxation, Part I RC and RL Circuits Page 4 of 6 Whenever a probe is initially connected to a scope, it is important to check this compensation. Most scopes have a small test point on the front panel at which a very precise square wave is provided for probe calibration. Touch the probe tip to this point and get a display of this signal. Then adjust the probe as needed to make the corners of the wave sharp and square. The probes are adjusted by a small screwdriver through the small hole on the box at the scope end of the cable. Normally you will not need to adjust the probe with the o scope and probes currently in use. It is also very important to note that all of the probes available in the physics lab attenuate (reduce) the signal being measured by a factor of ten. Thus, whenever a probe is in use, the Volts/div knobs on the scope should be read at the index that is marked "x10 probe".... Ground connections Remember that the outer shells of all the co-ax (BNC) connectors on the scope are internally connected together, and are connected to ground through the third wire in the power cable. It is therefore very important to take care that only one point gets grounded in the circuit being measured. Any time that two separate points get grounded everything between these points is "shorted" through ground... just as if a wire were connected across them. Thus there are two rules to be observed: 1. Only one probe should ever have a ground "pigtail" installed at the tip. 2. This ground should always be connected to the circuit at the low or ground side of the generator. GENERAL PROCEDURE for Half-Life Measurements A. Get a stable scope display of the desired signal. (Hint: make sure the trigger source is set on INT (internal trigger) and is using the signal from the Channel being measured) B. Adjust the sweep rate (time/div) so that several cycles are seen, and adjust the vertical amp (Volts/div) to approximately fill the screen. Your display should now look more or less like Figure 2 (either A or B depending upon what signal is being measured.) C. If your display does not clearly show the asymptotic part of the exponential, ie. if it looks more triangular than exponential, then your square wave frequency is set too fast. This simply shows that the polarity (square wave) changes are taking place much too quickly for the circuit to keep up. Reduce the generator frequency until the horizontal asymptote can be seen. Likewise, if the asymptote seems to go on forever the generator speed should be increased in order to get about 2 charge/discharge cycles on the screen. D. Now use your head (think!) and adjust the display (horizontal and vertical) to give you a charge or discharge pattern that fills the o scope screen as completely as possible. As per the experiment instructions on the next page, make sure that you are using both Channel 1 and Channel 2. You should be able to make a reasonably accurate measurement of the ½ life for either the charge curve or the discharge curve. If you are very clever, you will soon figure out a way of adjusting the time base (sec/cm horizontal) to stretch the display out, thereby enabling you to make a much more accurate measurement of the ½ life.

Rev. 7/15/10 HEFW Lab #11 Rapid Relaxation, Part I RC and RL Circuits Page 5 of 6 THE EXPERIMENT Throughout these experiments, it must be kept in mind that R represents the total series resistance in the circuit. This includes the internal resistances of the generator, of the inductor, and of all connecting wires, as well as any component resistor(s) that may be installed. The connecting wires make a very tiny contribution to the total and may safely be ignored. The inductor, on the other hand, contains many turns of very fine wire, and thus has a substantial resistance. Measure it!! (Hint:...ohmmeter). There are several techniques for determining the internal resistance of a generator, all closely related to those used in the earlier experiment on the Load-Line of a battery. The generators available in the physics lab have resistances of 50 ohms on all scales, Sine or Square. 1. Connect the RC circuit as shown below, with initial values of R = 5.6 k and C = 0.1µF. Measure the halflife for V C and compare with the expected value. Your oscilloscope has 2 input channels, 1 and 2. In normal circumstances, you should always use both, one for the input signal to your circuit and the other for the output signal. That way you can see the input and the output and you can easily compare them by having both on the screen at the same time. Generally you should trigger the oscilloscope on CH 1 since the input signal is more likely to be consistent and easy to trigger with. Notice that the signal generator and both channels of the O scope must have a common ground since they are connected through the shield of the co-axial cable and/or the 3 rd wire on the power plug. 2. Repeat for enough different RC combinations to convince yourself that you understand the method. 3. Replace the resistor with a variable resistor, and describe the behavior of the exponential as the resistance is varied. Does this make sense to you? Can you use a half-life measurement to determine the resistance of a particular setting on the variable resistor? TRY IT! Check your result by using the ohmmeter. 4. Reconnect the circuit so you can measure the half-life for V R and confirm that you get the same value. This requires some thought about the ground location. (Hint Look at the RL circuit in section 5 below.) Hints: You might naively think that you simply connect CH 2 across R to measure V R. But there are problems! If you connect CH 2 ground to the left (+) side of R, you are grounding the + side of the signal generator, thereby possibly damaging it. If you connect CH 2 ground to the right (-) side of R, then the capacitor is grounded top and bottom (shorted) so it is effectively removed from the circuit. So what can you do? - Think about interchanging R and C in the circuit. Then go ahead and make your measurements for V R. (Of course, you can t make simultaneous measurements of V C now.)

Rev. 7/15/10 HEFW Lab #11 Rapid Relaxation, Part I RC and RL Circuits Page 6 of 6 5. Now examine at least one RL circuit (R = 1k and L ~20mH are reasonable values). Compare the measured half-life with the theoretically expected value. 6. Examine the shapes of the exponential voltage signals across both the resistor and the inductor. Give a qualitative explanation for these shapes in a manner similar to that presented above (in the METHOD section) for the RC circuit. Do these two voltages in fact add up to a square wave as demanded by Kirchoff's rule? Explain your answer! 7. There is a clever way of avoiding the ground problem for the RC and RL circuits which allows you to look with the o scope at both V R and V C at the same time (or V R and V L ).* Build a circuit as shown. Make sure that both R s are nearly identical in value and the same for the capacitors or inductors. Connect CH1 across V C or V L and connect CH 2 across V R. You can now study V R and V C or V L at the same time. Sketch the two responses (V R and V C, or V R and V L ). [Make sure that you are using the same vertical amplitude (V/cm) setting for both channels.] Now find the setting (switch) on the o scope that allows you to see CH 1 plus CH2. (Add CH1 and CH 2.) If you are set up properly, you should see a square wave. Why? Explain! Does this observation agree with your sketches of V R and V C or V R and V L? *A clever student suggested this some years ago.