Horticultural Lighting Test Report

Similar documents
Photometric Test Report

Horticultural Lighting Test Report

Photometric Test Report

Photometric Test Report

Photometric Test Report

Photometric Test Report

NVLAP LAB CODE:

NVLAP LAB CODE:

NVLAP LAB CODE:

NVLAP LAB CODE:

Photometric Test Report

NVLAP LAB CODE:

Photometric Test Report

POST TOP FIXTURE C40T

Photometric Test Report

Photometric Indoor Test Report

Photometric Test Report

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Checked X.CAO

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

Checked X.CAO

LM Test Report

AcuVivid CV Series. sirs-e.com. Flexible White LED Strips

LM Test Report

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

LM Test Report

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

LM Test Report

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test. for LED. Cabinet

REVOLUTION LIGHTING TECHNOLOGIES INC

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

IES LM MEASUREMENT AND TEST REPORT. Test Model: SRLED-RTUS24-4K. Jeanne Han/Safety Manager

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

Cat# LED Wall-PACK

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE:

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

QPL ID # PLG2YNJ831VZ

752 North State St, #208, Westerville, OH Photosynthetically active radiation (PAR) & Electrical measurement

Test Sample Description Catalog Number: Description:

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Dimming: PWM/TIME/0-5V/0-10V. RoHS

Test Sample Description Catalog Number: Description:

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

RoHS QPL ID # PLC6V1PABNUJS

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

Morris Products 53 Carey Road, Queensbury, NY 12804

RoHS. Model: VAC 50/60HZ.83A Max 100W

Transcription:

Horticultural Lighting Test Report Relevant Standards IES LM-79-2008 ANSI C78.377-2011, ANSI C82.77-2002 CIE 13.3-1995, CIE 15-2004, IES TM-30-15 Prepared For Smart Grow Technologies 69319 Panoramic Dr Sisters, OR 97759 United States Catalog Number GOLDENi Order Number 11645806 Test Number 11645806.01 Test Date 2017-03-02 Prepared By Approved By Javier Caban, Technician Tiffany Hamm, Project Handler The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Test Number 11645806.01 - Page 1 of 4

Luminaire Description: Lamp: Mounting: Green aluminum housing 1980 white LEDs Surface Ceiling Luminaire Radiant Flux: Luminous Flux: Luminaire Efficacy: CCT: CRI (Ra): Chromaticity (x): Chromaticity (y): Chromaticity (u): Chromaticity (v): Duv: Summary of Results 316800 mw 101000 lm 144.6 lm/w 3666 K 84.9 0.3930 0.3765 0.2335 0.3356-0.0041 Test Conditions Test Temperature: Voltage: Current: Power: Power Factor: 25.7 48.00 14.55 698.6 1.000 C VDC A W Testing was performed in a 3-meter integrating sphere using the 4π geometry method. Absorption correction was employed for this measurement. Test Number 11645806.01 - Page 2 of 4

Spectral Flux[μmol/sec/nm] Yellow Green Cyan Infrared Blue Violet Red UVA Orange Horticultural Lighting - Integrating Sphere Integrating Sphere Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 25.7 C 48.00 VDC 14.55 A 698.6 W 1.000 N/A N/A Summary of Results Radiant Flux 316.80 Watts Radiant Efficiency: 45.3 % Luminous Flux: 101000 Lumens Luminous Efficacy: 144.57 lm/w PPF (400-700nm): 1445.24 μmol/sec PPF Efficacy: 2.0688 μmol/sec/w PBAR Flux(350-800nm): 1498.78 μmol/sec PBAR Efficacy: 2.1454 μmol/sec/w Lumens to μmol/sec conversion factor: 0.014309 μmol/sec/lm 10.00 9.00 Wavelength Range Photon Flux Wavelength Photon Flux [nm] [μmol/sec] Range [nm] [μmol/sec] 350-360 0.593683 590-600 91.843824 360-370 0.671240 600-610 92.753781 370-380 0.745226 610-620 89.220549 380-390 0.870049 620-630 81.882510 390-400 1.111737 630-640 71.912689 400-410 1.576782 640-650 60.719768 410-420 3.005229 650-660 49.654012 420-430 7.646103 660-670 39.504750 430-440 20.200239 670-680 30.749995 440-450 47.279063 680-690 23.548344 450-460 55.916903 690-700 17.819471 460-470 33.714559 700-710 13.366527 470-480 24.026418 710-720 9.973490 480-490 24.757384 720-730 7.419604 490-500 31.581321 730-740 5.492697 500-510 38.855827 740-750 4.072458 510-520 44.056191 750-760 3.030616 520-530 48.155148 760-770 2.259220 530-540 52.728277 770-780 1.690353 540-550 58.257819 780-790 1.276138 550-560 64.771719 790-800 0.968467 560-570 72.148860 570-580 79.891557 580-590 87.056384 Flux vs Wavelength 8.00 7.00 6.00 5.00 4.00 3.00 2.00 1.00 0.00 350 400 450 500 550 600 650 700 750 800 850 Wavelength [nm] Test Number 11645806.01 - Page 3 of 4

Horticultural Lighting - Definition of Terms Radiant Flux: The measured radiant power of the test item in units of watts from 350nm to 850 nm. Luminous Flux: The measured radiant power of the test item in units of lumens from 380nm to 780 nm. PPF (400-700nm): Photosynthetic Photon Flux - Flux from 400 to 700 nm expressed in units of μmol/sec This wavelength range has been identified as important to photosynthetic processes. PBAR Flux(350-800nm): Plant Biologically Active Radiation Flux - Flux from 350 to 800 nm expressed in units of μmol/sec. Plants have photopigments other than chlorophyll that are sensitive to a wider range of wavelengths than chlorophyll. Radiant Efficiency: The ratio of light flux in watts to electrical input power in watts expressed in percent. Luminous Efficacy: The ratio of light flux in lumens to electrical input power in watts expressed in lm/w. PPF Efficacy: The ratio of photosynthetic photon flux to electrical input power in watts expressed in μmol/sec/w. PBAR Efficacy: The ratio of photon flux in the wavelength range 350 to 800 nm to electrical input power in watts expressed in μmol/sec/w. PPFD: Photosynthetic Photon Flux Density - Flux per unit area expressed in μmol/sec/m 2. Lumens to μmol/sec conversion factor: Multiply flux in lumens by this factor to convert to PPF in units of μmol/sec. This conversion factor can also be used to convert illuminance in lux to photosynthetic photon flux density (PPFD). To convert from footcandles to PPFD first convert the illuminance in fc to lux by multiplying by 10.7639 lux/fc and then use the lumens to μmol/sec conversion factor. Note: This factor applies to the measured spectral distribution only and cannot be applied to other light sources. Test Number 11645806.01 - Page 4 of 4

Model tested: GOLDENi Test Height: 10in Horticultural Lighting - PPFD [μmol/sec/m 2 ] 59.9 76.3 86.0 82.2 120.1 90.2 86.6 80.5 39.1 2ft 147.8 209.1 235.7 248.1 253.4 247.4 224.0 195.5 119.8 1.5 370.2 556.6 624.9 663.0 644.1 626.7 574.3 480.5 304.3 1 652.0 1003.9 1135.7 1169.6 1188.5 1176.4 1080.0 911.1 544.3 0.5 765.6 1182.9 1325.3 1366.8 1368.2 1352.3 1295.2 1116.9 675.0 0 683.4 1074.8 1199.1 1233.3 1230.7 1206.2 1139.0 966.4 603.5 0.5 386.8 644.2 732.7 768.1 756.7 719.5 691.4 574.2 350.1 1 175.0 237.6 264.8 294.2 294.2 264.5 260.6 225.9 158.2 1.5 65.5 89.2 108.7 119.9 126.7 129.5 119.4 95.4 69.2 2ft 2ft 1.5 1 0.5 0 0.5 1 1.5 2ft Maximum PPFD: 1368.2 μmol/sec/m 2 Minimum PPFD: Average PPFD: Uniformity (min/max): Power: 39.1 553.3 0.03 729.4 μmol/sec/m 2 μmol/sec/m 2 W Relative Spectral Power Distribution of Center Measurement Wavelength Bands PPF% Radiometric Flux% UV 250 400 NA 0.4% Violet/Blue 400 500 17.3% 20.4% Green/Yellow 500 580 31.9% 31.8% Orange/Red 580 700 50.8% 44.2% Far Red 700 780 NA 2.6% IR 780 850 NA 0.6% Test Number 11645806.01 - Page 5 of 5