Agilent E8247/E8257C PSG CW and Analog Signal Generators

Similar documents
Agilent E8267C PSG Vector Signal Generator

Agilent PNA Series RF Network Analyzers

Agilent E8267C/E8257C/E8247C PSG

Agilent MXG Signal Generators

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent. E8267C PSG Vector Signal Generator E8257C PSG Analog Signal Generator E8247C PSG CW Signal Generator

Agilent MXG Signal Generators

Agilent EPM Series Power Meters

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent E8257D PSG Microwave Analog Signal Generator

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent E4428C and E4438C ESG Signal Generators

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent E4428C and E4438C ESG Signal Generators. Confi guration Guide

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Advanced Test Equipment Rentals ATEC (2832)

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent 83711B and 83712B Synthesized CW Generators

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Agilent E8460A 256-Channel Reed Relay Multiplexer

Agilent 87415A, 87400A Microwave Amplifiers

Agilent Technologies 3000 Series Oscilloscopes

Agilent dc Electronic Loads Models N3300A-N3307A

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

expanding the possibilities

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Agilent PNA Microwave Network Analyzers

Product Note E5100A-2

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Agilent First-generation MXG Signal Generators

Agilent 4-Port PNA-L Network Analyzers

Agilent 8902A Measuring Receiver Product Note

Agilent EPM-P Series Single- and Dual-Channel Power Meters Agilent E9320 Family of Peak and Average Power Sensors

Advanced Test Equipment Rentals ATEC (2832)

Base Station Installation and Maintenance

6 Tips for Successful Logic Analyzer Probing

Agilent E4428C ESG Analog Signal Generator

Agilent 8761A/B Microwave Switches

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

Agilent NFA Noise Figure Analyzer

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

Agilent E4428C and E4438C ESG Signal Generators

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Using an MSO to Debug a PIC18-Based Mixed-Signal Design

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Agilent 8648A/B/C/D Signal Generators

Advanced Test Equipment Rentals ATEC (2832)

Agilent 8902A Measuring Receiver

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for GSM and EDGE Measurements

Advanced Test Equipment Rentals ATEC (2832)

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

Agilent NFA Noise Figure Analyzer

How to Drive the Agilent Technologies Microwave Matrix and Transfer Switch via the E8483A Microwave Switch/Step Attenuator Driver.

Agilent 4285A Precision LCR Meter

8 Hints for Better Spectrum Analysis. Application Note

Agilent E1345A 16-Channel Low-Offset Relay Multiplexer. Data Sheet. Description. Configuration. C-size Adapter

MXG X-Series Signal Generator N5183B Microwave Analog

Keysight Technologies E8257D PSG Microwave Analog Signal Generator. Configuration Guide

Agilent U2000 Series USB Power Sensors. Data Sheet

Meet the new E4438C ESG vector signal generator...

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Keysight Technologies E8257D PSG Microwave Analog Signal Generator. Configuration Guide

System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

Agilent CSA Spectrum Analyzer

Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

Picking the Optimal Oscilloscope for Serial Data Signal Integrity Validation and Debug

Choosing an Oscilloscope with the Right Bandwidth for your Application

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Flexible Signal Conditioning with the Help of the Agilent 81134A Pulse Pattern Generator

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent 87075C Multiport Test Set

Agilent E8247C/E8257C PSG CW and Analog Signal Generators Self Guided Demo. Product Note

EMC Precompliance Systems and Accessories Catalog

Agilent PNA Microwave Network Analyzers

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Agilent PNA Microwave Network Analyzers

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

Keysight Technologies First-Generation MXG Signal Generators

Advanced Test Equipment Rentals ATEC (2832)

Agilent 8752C RF Vector Network Analyzer

Agilent 8510 Network Analyzer Product Note A

Agilent 83554A/83555A/83556A mm-wave Source Modules* Data Sheet

Transcription:

Agilent E8247/E8257C PSG CW and Analog Signal Generators Configuration Guide E8257C PSG analog signal generator

Agilent Microwave PSG CW/Analog signal generators options Step 1. Choose type of signal generator with frequency range (Mandatory) E8247C-520 PSG CW Provides an 250 khz to 20 GHz unmodulated continuous wave signal (can be used as a LO substitute) E8257C-520 PSG analog Provides flexible 250 khz to 20 GHz analog modulation E8247C-540 PSG CW Provides an 250 khz to 40 GHz unmodulated continuous wave signal (can be used as a LO substitute) E8257C-540 PSG analog Provides flexible 250 khz to 40 GHz analog modulation Dynamic range Step 2. Choose a step attenuator option 1E1 (Not mandatory) E8247C-1E1 Adds output step User s application attenuator down to requires power 135 dbm level below 20 dbm (standard) E8257C-1E1 Adds output step User s application attenuator down to requires power 135 dbm level below 20 dbm (standard) Highest output power Step 3. Choose high output power - option 1EA (Not mandatory) E8247C-1EA High RF Provides +20 dbm output power RF output power at 20 GHz (typically +25 dbm) which eliminates the need for external amplifiers E8257C-1EA High RF Provides +20 dbm output power RF output power at 20 GHz (typically +25 dbm) which eliminates the need for external amplifiers 2

Lowest phase noise Step 4. Choose enhanced phase noise option UNR (Not mandatory) E8247C-UNR Enhanced phase User s application noise performance requires low close-in phase noise (i.e. 106 dbm (typical) at 1 khz offset from 10 GHz carrier) approximately 24 db improvement over standard E8257C-UNR Enhanced phase User s application noise performance requires low close-in phase noise (i.e. 106 dbm (typical) at 1 khz offset from 10 GHz carrier) approximately 24 db improvement over standard Narrow pulse modulation Step 5. Choose narrow pulse modulation - option 1E6 (Not mandatory) E8257C-1E6 Provides narrow Allows narrow pulse modulation pulses with fast >500 MHz rise & fall times of 10 ns from 500 MHz to the maximum frequency of the instrument Stimulus response capability with scalar network analyzer Step 6. Choose ramp sweep option 007 (Not mandatory) E8247C-007 Provides ramp User s application sweep, scalar requires stimulus interface, Z-axis response and blanking, and utilizes 8757D markers scalar network analyzer E8257C-007 Provides ramp User s application sweep, scalar requires stimulus interface, Z-axis response and blanking, and markers utilizes 8757D scalar network analyzer 3

Accessory options Choose accessories or instrument connector configuration (Not mandatory) Note: Standard 20 GHz models have a 3.5 mm (m) RF output connector on the front panel. Standard 40 GHz models have a 2.4 mm (m) RF output connector on the front panel. E8247C-1ED Type-N (f) connector E8247C-540 E8257C-1ED Type-N (f) connector E8257C-540 E8247C-1EM Move all connectors to rear panel E8257C-1EM Move all connectors to rear panel E8247C-1CM Rack mount kit E8257C-1CM Rack mount kit E8247C-1CN Front handle kit E8257C-1CN Front handle kit E8247C-1CP Rack mount kit with front handle kit E8257C-1CP Rack mount kit with front handle kit 83554A Millimeter-wave Banded solution E8247C-1EA or R-band 26.5 to 40 GHz 83555A Millimeter-wave Banded solution E8247C-1EA or Q-band 33 to 50 GHz 83556A Millimeter-wave Banded solution E8247C-1EA or U-band 40 to 60 GHz 83557A Millimeter-wave Banded solution E8247C-1EA or V-band 50 to 75 GHz 83558A Millimeter-wave Banded solution E8247C-1EA or W-band 75 to 110 GHz 8120-8806 Master/slave interface cable 4

To add options to a product, use the following ordering scheme: Model: E82x7C, where x = 4 or 5 Example model options: Option E8247C-520 Option E8257C-520 Manuals Choose manuals (Not mandatory) Standard products ship with electronic (CD-ROM) manuals. The CD-ROM includes a user s guide, programming and calibration guides, Intuilink and other product literature. E82x7C-ABA English manual set (hardcopy no CD) E82x7C-ABD German localized supplemental user s guide (hardcopy no CD) E82x7C-ABF French localized supplemental user s guide (hardcopy no CD) E82x7C-ABJ Japanese localized supplemental user s guide (hardcopy no CD) E82x7C-ABA Korean localized supplemental user s guide (hardcopy no CD) E82x7C-CD1 CD-ROM documentation includes PDF files of user s guide, calibration guide, service quide, SCPI command reference guide, error messages, key reference guide, and additional product literature) E82x7C-OBW Adds the service manual (assembly level) E82x7C-UK6 Commercial calibration certificate with test data Choose documentation (Not mandatory) If you want to order the PSG s documentation separately Selection Documentation Title part number E8251-90259 Service Guide E8251-90251 User s Documentation on CD-ROM E8251-90252 Installation Guide E8251-90253 User s Guide E8251-90254 Key and Data Field Reference E8251-90255 Programming Guide E8251-90256 SCPI Command Reference E8251-90257 Error Messages 5

Warranty, service and calibration options Choose a warranty plan (not mandatory) Standard 1-year return-to-agilent warranty and service 3 years Extended return-to-agilent warranty and service 5 years Extended return-to-agilent warranty and service Choose a calibration plan 1 (not mandatory) There is no calibration plan standard with the E8267C. For a calibration plan, specify 3 or 5 years for one of the appropriate plans below when ordering. For more information on the plans, please visit www.agilent.com/find/services_upfront_options. N/A Agilent Calibration Upfront Plan N/A Agilent Calibration Plus Upfront Plan N/A Z540 Calibration Upfront Plan There are no factory or service center upgradeable options for E8247C and E8257C signal generators. Customer installable upgrade options Upgrade kit will be sent to the customer for installation. Service center can install upgrade kits for an additional cost. Please consult your local Agilent representative for further information. Selection Upgradeable Description options E8247CK-1EA High output power E8257CK-1EA High output power E8247CK-007 High output power E8257CK-007 High output power 6 1. Options not available in all countries.

Related Agilent literature PSG Signal Generator Brochure Literature number 5989-1324EN Agilent E8247/57C PSG CW and Analog Signal Generator Data Sheet Literature number 5988-7454EN Agilent E8267C PSG Vector Signal Generator Data Sheet Literature number 5988-6632EN Agilent E8267C PSG Vector Signal Generator Configuration Guide Literature number 5988-7541EN PSG Series Product Note: Millimeter Head Literature number 5988-2567EN PSG Two-tone and Multi-tone Application Note Application Note 1410 Literature number 5988-7689EN For further information about renting, leasing and/or financing Agilent s latest technology, visit http://buyalternatives.tm.agilent.com/ When you are looking for an accessory, you need to find it fast. Agilent Technologies has designed this site to help you quickly find the accessory that is just right for your job: www.agilent.com/find/mta Free Agilent software: Latest software and drivers for the PSG Upgrade your PSG with the latest software enhancements PSG/ESG Download assistant software Download waveforms directly from the MATLAB environment into the signal generator for playback Agilent IntuiLink connectivity software Connectivity software solution that links test and measurement instrument data to PC applications The above free software can be found by selecting the Software, Firmware, & Drivers embedded link located on each of the PSG E8267C, PSG E8257C or PSG E8247C (where applicable). For more information visit: www.agilent.com/find/psg 7

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent T&M Software and Connectivity Agilent s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit www.agilent.com/find/connectivity for more information. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Product specifications and descriptions in this document subject to change without notice. Phone or Fax Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080)769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com Contacts revised: 1/12/05 MATLAB is a U.S. registered trademark of The Math Works, Inc. Agilent Technologies, Inc. 2002, 2004, 2005 Printed in USA, March 1, 2005 5988-7879EN