KEY WORDS: conductive, clothing, live, line, maintenance, high, voltage

Similar documents
EXPERIMENTAL ISSUES OF OVERVOLTAGE COORDINATION

Technical Committee106 Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure

LOW-FREQUENCY MAGNETIC FIELDS IN SECONDARY SUBSTATIONS

ELF ELECTRIC AND MAGNETIC FIELDS MEASUREMENTS IN GREECE

ELECTROMAGNETIC POLLUTION INSIDE HIGH VOLTAGE SUBSTATION

Analytical Design Optimization of 765 kv Transmission Line Based on Electric and Magnetic Fields for Different Line Configurations

Investigation of skin effect on coaxial cables

Investigation on the Performance of Different Lightning Protection System Designs

Technical Note 2. Standards-compliant test of non-ionizing electromagnetic radiation on radar equipment

3 THE REVIEW OF DISSERTATION

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

High Voltage Testing. Team 5: Justin Bauer, Matt Clary, Zongheng Pu, DeAndre Dawson, Adam McHale

Analysis of lightning performance of 132KV transmission line by application of surge arresters

Analogue Demo Multimeter ADM

Environmental Exposures to ELF Georg Neubauer

SCANTER 5000 and 6000 Radar Series

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

Class: RPT Doc. no: RE Rev: A Date: Approved by: JCP

Diagnostic testing of cast resin transformers

2620 Modular Measurement and Control System

Transformer Basics AN05-10ST. Application Note. innovation in wire wound magnetic technology. January 09 Rev 1

Influence of interface cables termination impedance on radiated emission measurement

Precautionary Principle in Health Protection Policies regarding Electromagnetic Fields (EMF)

The Lightning Event. White Paper

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

Environmental & Interference Effects of HVDC Converters & Lines

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

VACUUM INTERRUPTER APPLICATION NOTES Filename: VIAN X-Rays and Vacuum Interrupters Revision: 0 PAGE 1

Electromagnetic Compatibility ( EMC )

Overview of the ATLAS Electromagnetic Compatibility Policy

via cable Route of signal interferences Shielding against radiation

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

Internal Model of X2Y Chip Technology

Industrial and Commercial Power Systems Topic 7 EARTHING

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

DESIGN OF A 45 CIRCUIT DUCT BANK

Bridgeport Magnetics Design Guide

Broadband Current Probe Series Operation Manual

Research Activities Plan. Appendix K Magnetic Fields from Submarine Cables

INTRODUCTION well below

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Radiated emission is one of the most important part of. Research on the Effectiveness of Absorbing Clamp Measurement Method.

Appendix 6-F: Electric and Magnetic Field Study Report

Examination of Organ Flue Pipe Resonator Eigenfrequencies by Means of the Boundary Element Method

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

ENGLISH TRANSLATION GUIDELINES FOR THE USE OF WIRELESS POWER TRANSMISSION/TRANSFER TECHNOLOGIES TECHNICAL REPORT. BWF TR-01 Edition 2.

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

Model EARTH RESISTANCE CLAMP USERS MANUAL EARTH RESISTANCE C L A M P : CAT II. 1mA 20A AL : ~ 600V

Fig.1. Railway signal system

Electrical Severity Measurement Tool Revision 4

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Experiment 12: Microwaves

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

INTERNATIONAL STANDARD NORME INTERNATIONALE

AC/DC CLAMP METER USER S MANUAL

Coherence and time-frequency analysis of impulse voltage and current measurements

Wireless System Collocation Presents New Issues For Worker Protection

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Earthing of Electrical Devices and Safety

Investi ations Into the Use of Temperature Detectors as # tator Winding Partial Discharge Detectors

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

How OSHA s New Transient Overvoltage Requirements Affect Work Practices. B.A. YEUNG, H. BRANCO Leidos Engineering, LLC USA

MAGNETIC FIELD COMPUTATION DUE TO HIGH VOLTAGE POWER LINES USING EasyMAG

THE RUSSIAN STANDARDS AND THE OPINION ABOUT INTERNATIONAL HARMONIZATION OF ELECTROMAGNETIC STANDARDS

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 04, 2014 ISSN (online):

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

ISO INTERNATIONAL STANDARD

Workplace safety for demagnetizer operators

Novel Simulation Method to Quantify Induced Voltage & Current between Parallel or Partially Parallel Proximity AC Transmission Circuits

Manual Unihan UPWL6024

Shielding Effect of High Frequency Power Transformers for DC/DC Converters used in Solar PV Systems

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Electrical Measurement Safety. Sponsored By:

MW3105 DIGITAL CLAMP MULTIMETER

USER MANUAL MHS-2500I. Please take time to read these instructions before starting to use the scale. Version /17

Electromagnetic Compatibility

STJ-300 Single-Axis Magnetic Sensor Dual In-line Package

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

The active areas are represented by purple ellipses, and the bond pads are shown in gold. All dimensions in microns.

FISCHER CUSTOM COMMUNICATIONS, INC.

EAS Electrical Appliance Serviceperson Answer Schedule

First Draft Language

Understanding Noise Cut Transformers

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

TEST REPORT... 1 CONTENT...

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Immunity Testing for the CE Mark

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Test and Measurement for EMC

OIML R 130 RECOMMENDATION. Edition 2001 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Octave-band and one-third-octave-band filters

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Lightning transient analysis in wind turbine blades

The Role of the Grounding System in Electronics Lightning Protection

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

HIGH VOLTAGE Insulation Coordination

ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1. Chapter 8: Cable Modeling

Transcription:

BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS BUDAPEST, HUNGARY 23 April 2015 CURRENT ISSUES REGARDING TO THE INSPECTION OF CONDUCTIVE CLOTHING Author/s: GÁBOR GÖCSEI, BÁLINT NÉMETH Company or institution: BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS Position: GÁBOR GÖCSEI (assistant lecturer), BÁLINT NÉMETH (lecturer, Head of High Voltage Laboratory) KEY WORDS: conductive, clothing, live, line, maintenance, high, voltage COMPANY S DATA Address: Egry József u. 18. Zip Code: 1111 Phone: +36 1 463 3236 Fax: +36 1 463 3231 E-Mail: gocsei.gabor@vet.bme.hu SUMMARY There are different standards and regulations to inspect the efficiency of conductive clothing. IEC s 60895 is widely used and has a complete set of tests including resistance measurement, screening and shielding efficiency inspection, etc. In some cases arrangement of the measurements is not strict enough. In the High Voltage Laboratory of Budapest University of Technology and Economics a suggested modification of the current arrangement of screening efficiency measurement has been developed. Application of new techniques as a part of the next version of the standard is under consideration by IEC s committee. Based on our laboratory measurements during high voltage liveline maintenance high electric fields often above the current limits defined by International Commission on Non- Ionizing Radiation Protection (ICNIRP) may occur. Without any face mesh, face of the worker might be endangered by their harmful effects and critical strength of them often cannot been determined by the current ways of inspection. Suggested arrangement is safer, more efficient and demonstrates real circumstances better than the actual one. During the approach of the conductor or working at the potential of the phase conductor electric field distribution has been calculated and simulated on a 3D model. Critical size of the Faraday-holes as a function of voltage level has also been determined. Suggested modifications are expected to increase the safety of the inspection, so the liveline work. To protect the workers and to guarantee their maximal level of safety always has to be a first priority during any kind of live-line related regulation. The aim of this paper is to prove that suggested inspections are more realistic and effective than the actual set of test based on the results of simulations and measurements.

Introduction Live-line maintenance is widely applied nowadays because of its technical and economic benefits. At high voltage levels barehand method is a common way of working in a special conductive clothing acting as a Faraday cage to shield extra-low frequency electric field around the workers. Without any face protection electric field may exceed the current exposure limits (defined by ICNIRP as 10 kv/m [1], [2]) during high voltage live-line maintenance inside the conductive clothing. It have to be guaranteed that electric field strength remains below the applicable limits at any point inside the clothing and at any time during the work. Electric field distribution on the face without any face mesh: approach of phase conductor During the approach of the phase conductor, potential of the conductive clothing floats. In this case, electric field strength increases in front of the face of the worker as the distance between the clothing and the phase conductor decreases. Figure 1 shows the values of electric field strength inside the clothing. Each value is an average of calculated electric field evaluated in 10 000 points by finite element method on a 3D CAD model and each curve is approximated by a 3 rd degree polynomial function. As it can be seen from Figure 1, above 110 kv electric field strength becomes higher than the limit, even in the distance of 60 cm (23.62 ). Fig. 1. Maximal electric field strength as a function of distance from phase conductor. Electric field distribution on the face without any face mesh: energized clothing After the connection of the potential clamp to the phase conductor, the conductive clothing becomes energized; the electric potential of the clothing and the phase conductor will be equal. In this case, electric field strength decreases in front of the face of the worker as the distance between the clothing and the phase conductor decreases: the root cause is a basic physical law: between same potentials electric field is shielded by the conductive parts as electrodes. As in case of Figure 1, electric field was evaluated in 10 000 points by finite element method on a 3D CAD model and each curve is approximated by a 3rd degree polynomial function. Figure 2 shows the values of electric field strength inside the clothing. As it can be seen from Figure 2, electric field strength is higher than the limit in all cases - even in the minimum distance and at the lowest voltage level applied.

Inspection of screening efficiency Fig. 2. Maximal electric field strength as a function of distance from phase conductor. Inspection of different face mesh designs Electric field strength as a function of the radius of the openings on the face mesh (approximated as circles) can be seen in Figure 3. Results are obtained from finite element calculations and are validated by laboratory measurements at the voltage range of 75-220 kv. Current arrangement of IEC 60895 ed2.0 does not demonstrate the highest electric field which can be occurred during real working conditions. A new arrangement based on the Hungarian Csikós test method - which was widely used between 1970 and 2000 in the territory of the Hungarian TSO - is suggested to: make the process of the inspection safer: it is neither safe nor easy to handle measuring devices which are energized simulate real (even worst-case) conditions: in the current arrangement critical electric field is mostly shielded by the same electric potential of the protective parts and the phase conductor; in real working environment much worse conditions may occur (e.g. around the towers or insulators, where grounded structures are relatively close to the energized parts - including the conductive clothing worn by the worker - or between the conductors of different phases) increase the accuracy of the test: in the current arrangement it is not easy to recognize the difference between the different types of conductive clothing. Fig. 3. Electric field strength as a function of mesh opening radius. As it can be seen at the voltage level of 1200 kv above a Faraday-hole radius of 1.75 cm (0,69 ) electric field strength becomes higher than the current limit. In case of the minimal inspected voltage (75 kv) above a hole radius of 4 cm (1.57 ) electric field strength exceeds the critical value (10 kv/m). Electric field and capacitive currents have been measured in different arrangements to validate the results of calculations and simulations [3]-[7]. The current procedure shall be carried out at the phase-toearth voltage corresponding to the maximum nominal AC voltage at which the clothing can be used. The screening efficiency shall be determined by (1). I1 V = I + I 1 2 (1)

The conductive suit pass the test, if the screening efficiency (V) is above 99%. By measuring this way, conductive clothing without any face protection can pass the test (value of current I1 is high). As it can be seen from the direct electric field strength measurement results, during normal working conditions without any face mesh electric field strength might be higher than the limits, so this arrangement is not suitable to inspect the screening efficiency of a conductive clothing effectively. Laboratory measurements The current regulations do not contain any exact details about the placement of the energized conductor; during the test a high voltage wire has been placed to the height of the head in a distance of 30 cm (11.81 ) from the face of the mannequin. The test voltage level was 111.5 kv and the distance between the ground and the live parts was 1.12 meters (44.09 ). During the first experiment the face screen of the suit was folded, so the whole surface of the face was protected by the face mesh. With a leakage current I1 of 1412 µa and I2 of 13 µa, efficiency V is 99.08% in this case, which is above 99 percent, so the suit has passed the test. In the second case leakage current without face mesh has been measured, so the face was completely unprotected. In this case current I1 was 1445 µa and I2 was 14 µa, so the efficiency V is 99.04%. As it can be seen from the results, the leakage current was almost the same with and without the face mesh. Arrangement of measurement is shown in Figure 4. Fig. 4. Electric field measurement in laboratory environment. Simulation results The arrangement of this test has been simulated by finite element method (FEM) on a 3D model with a standardized human body by IEC 62233 [8]. Figure 4 shows the results of the simulation for the electric field distribution in the current arrangement for screening efficiency inspection of IEC 60895 (7.2. paragraph) [9]: an energized conductor is placed in front of the mannequin at the same potential than the conductor, isolated from the ground. Leakage currents to be measured are induced by electric field between the energized electrodes and the ground, so distribution has a significant effect on the results. As it can be seen in Figure 5, the electric field is very low near the face; it is shielded by the same potential of the conductor and the mannequin inside the conductive clothing. This arrangement simulates the best case from the aspect of electric field distribution instead of the worst-case scenario.

Fig. 6. Effect on the results of surroundings in the current arrangement. Fig. 5. Electric field distribution in the current arrangement. Another issue with this arrangement is that the strength of the electric field strongly depends on the distance from the grounded parts in the surroundings of the arrangement, so the measurement cannot be repeated easily. The measurement has been repeated with a different electrode arrangement (a few, and after that significantly more grounded structures in the vicinity of the arrangement, further than the minimal distance calculated from the standard). Figure 6 shows the difference between the results of the two experimental measurements. As it can be seen from the results of the simulation, grounded parts in the surroundings of the measurement have significant effects on the strength and distribution of electric field. The standard only determines the minimal distance from the nearest grounded part as a function of applied voltage. Electric field distribution - and value of leakage currents might be easily modified by some grounded structures in the vicinity of the arrangement. This makes this way of measurement hard to repeat. Suggested way of measurement Both theoretical (FEM simulations) and practical (laboratory measurements) investigations have proved that the current arrangement of IEC 60895 for the inspection of screening efficiency is not effective enough. Based on the results the High Voltage Laboratory of Budapest University of Technology and Economics suggests some modifications in the way of this measurement. The main disadvantages of current way of measurement: there is no significant difference in the results between acceptable and not acceptable clothing (even not acceptable clothing may pass the test because of the shielded area by the arrangement in front of the face, which is critical from the aspect of Faraday-holes ) instruments are energized; it is not safe and not easy to read them correctly the position of the energized conductor is not determined clearly it is hard to repeat the measurement because of the significant effect of grounded structures on the results in the vicinity of the arrangement.

The main difference from the current way of inspection is that the mannequin (with a conductive surface in conductive clothing) shall be placed into inhomogeneous electric field. The body and the clothing shall be grounded through micro-ammeters. A high voltage conductor shall be placed at height of the horizontal midline of the head, in front of the mannequin. The distance between the conductor and the mannequin shall be determined by the valid standard for the evaluation of minimal arcing distance. The test shall be carried out at the maximal design AC (phase-to-earth) voltage of the clothing. Suggested mannequin-to conductor-distances shall be calculated from IEC 61472 ed3.0 [10]. Efficiency V shall be above 99%. FEM simulation results of electric field distribution in the suggested arrangement as a function of grounded structures in the vicinity of the measurement are shown in Figure 7. As it can be seen from the results, in this case the environment does not affect the electric field distribution - neither the value of leakage currents - significantly. The highest electric field strength occurs in front of the face, similarly than during real working conditions during approaching the conductor. After the simulations, results have been validated by laboratory tests: a conductive clothing with and without face mesh at a voltage level of 111.5 kv has been inspected in the suggested arrangement. At this voltage level the minimal arcing distance is 0.5 m (19.69 ) by IEC 61472 ed3.0. Table 3 summarizes the results in the suggested arrangement. TABLE I. RESULTS IN THE SUGGESTED ARRANGEMENT Conductive clothing Conductive clothing without with face mesh face mesh I body I clothing [µa] [µa] V [%] I body I clothing [µa] [µa] V [%] 0.5 360 99.86 6.6 350 98.12 Fig. 7. Effect of surroundings on the results in the suggested arrangement. As it can be seen from the results of Table 3, efficiency of conductive clothing with face mesh became much higher than the other conductive clothing without any face protection which has failed the test. Results are clear and there are significant differences between the values of screening efficiencies both in case of acceptable and not acceptable results. Validation of new arrangement suggestion in laboratory environment As a part of a laboratory experiment a mannequin (with a conductive surface) in conductive clothing has been placed in a distance of 30 cm (11.81 ) from an energized high voltage conductor. The potential of the clothing and the conductor were the same during the test. Electric field has been measured between the face and the face mesh with EPRI/Enertech EMDEX II field measurement system and free body type E-probe in x, y and z directions [11] at the voltage levels of 25, 50, 69.3, 75 and 100 kv. Electric field norm is shown in the figures. In the first case the face of the mannequin was

unprotected. Figure 8 summarizes the results of electric field strength measurement as a function of voltage. As it can be seen from the chart, values are much above the limits at all voltage levels. In the second case, a face mesh has been folded in the front of the face. Electric field strength has been measured at the same voltage levels than in the first case (Figure 9). References [1] International Commission On Non ionizing Radiation Protection, ICNIRP Statement, General Approach to Protection Against Non Ionizing Radiation Protection, Health Physics 82(4):540 548, 2002 [2] International Commission On Non ionizing Radiation Protection, ICNIRP Guidelines for Limiting Exposure to Time Varying Electric and Magnetic Fields (1 Hz 100 KHz), Health Physics 99(6):818 836, 2010 [3] G. Göcsei, B. Németh, Z. A. Tamus, I. Kiss, Face Protection Investigation Against Electric Field On Live Line Workers, Keynote, 2012 IEEE International Symposium of Electrical Insulation, San Juan, USA, pp. 535-539, ISBN: 978-1-4673-0486-3 Fig. 8. Electric field strength in a distance of 30 cm from the conductor (without face mesh). [4] Göcsei G., Németh B., Kiss I., Berta I., Shielding efficiency of conductive clothing in magnetic field, Journal Of Electrostatics 71:(3) pp. 392-395, DOI: 10.1016/j.elstat.2013.01.001 [5] Gábor Göcsei, Bálint Németh, Dániel Tarcsa, Extra low frequency electric and magnetic fields during live-line maintenance, IEEE Electrical Insulation Conference, Ottawa, Canada, Computer Society Press, pp. 100-104, ISBN: 978-1-4673-4739-6 Fig. 9. Electric field strength in a distance of 30 cm from the conductor (with face mesh). As it can be seen the face mesh has increased the screening efficiency significantly; the electric field remained below the limit at all voltage levels. According to the results, face screen is a very important piece of the conductive clothing, which significantly reduces the electric field in the vicinity of the face; it shall be applied on every class of conductive clothing. [6] G. Göcsei, B. Németh, I. Kiss, I. Berta, Health effects of magnetic fields during live-line maintenance, International Conference on Live Maintenance (ICOLIM) 2014, Budapest, Hungary, Paper 235, pp. 6, ISBN: 978-1-4799-5993-8 [7] G. Göcsei, B. Németh, Á. Tamus, I. Kiss, J. Meixner, Shielding efficiency of conductive clothing during live-line maintenance, International Conference on Live Maintenance (ICOLIM) 2014, Budapest, Hungary, Paper 306, pp. 5, ISBN: 978-1-4799-5993-8

[8] IEC 62233 ed1.0, Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure, International Electrotechnical Commission, 2005 [9] IEC 60895 ed2.0, Live working - Conductive clothing for use at nominal voltage up to 800 kv a.c. and +/- 600 kv d.c., International Electrotechnical Commission, 2002 [10] IEC 61472 ed3.0, Live working - Minimum approach distances for a.c. systems in the voltage range 72,5 kv to 800 kv - A method of calculation, International Electrotechnical Commission, 2013 [11] http://www.enertech.net/html/eprobe.html, date of visit: 16 April, 2015