attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Similar documents
:... resolution is about 1.4 μm, assumed an excitation wavelength of 633 nm and a numerical aperture of 0.65 at 633 nm.

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Microscopic Structures

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Evaluation of Confocal Microscopy. for Measurement of the Roughness of Deuterium Ice. Ryan Menezes. Webster Schroeder High School.

Kit for building your own THz Time-Domain Spectrometer

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Microscopy: Fundamental Principles and Practical Approaches

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Sensors and Metrology - 2 Optical Microscopy and Overlay Measurements

3D light microscopy techniques

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

Microscopy. Matti Hotokka Department of Physical Chemistry Åbo Akademi University

Microscope anatomy, image formation and resolution

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

Introduction of New Products

Bringing Answers to the Surface

Bandpass Edge Dichroic Notch & More

Instructions for the Experiment

Supplementary Information. Stochastic Optical Reconstruction Microscopy Imaging of Microtubule Arrays in Intact Arabidopsis thaliana Seedling Roots

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

Katarina Logg, Kristofer Bodvard, Mikael Käll. Dept. of Applied Physics. 12 September Optical Microscopy. Supervisor s signature:...

Optical Microscopy and Imaging ( Part 2 )

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D

Variable microinspection system. system125

SUPPLEMENTARY INFORMATION

Improving the Collection Efficiency of Raman Scattering

Exp No.(8) Fourier optics Optical filtering

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal

Multi-kW high-brightness fiber coupled diode laser based on two dimensional stacked tailored diode bars

DIMENSIONAL MEASUREMENT OF MICRO LENS ARRAY WITH 3D PROFILOMETRY

Reflecting optical system to increase signal intensity. in confocal microscopy

Light Microscopy. Upon completion of this lecture, the student should be able to:

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Effects of spherical aberrations on micro welding of glass using ultra short laser pulses

Nanoimprint lithography with a focused laser beam for the fabrication of micro-/nano-hybrid patterns

REAL TIME THICKNESS MEASUREMENT OF A MOVING WIRE

Transmission electron Microscopy

Systems Biology. Optical Train, Köhler Illumination

CHAPTER TWO METALLOGRAPHY & MICROSCOPY

Transmission Electron Microscopy 9. The Instrument. Outline

Fast Laser Raman Microscope RAMAN

Analytical analysis of modulated signal in apertureless scanning near-field optical microscopy C. H. Chuang and Y. L. Lo *

TECHSPEC COMPACT FIXED FOCAL LENGTH LENS

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Tissue Preparation ORGANISM IMAGE TISSUE PREPARATION. 1) Fixation: halts cell metabolism, preserves cell/tissue structure

SENSOR+TEST Conference SENSOR 2009 Proceedings II

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

A broadband achromatic metalens for focusing and imaging in the visible

Supplementary Materials

Microscopy Techniques that make it easy to see things this small.

Applications of Optics

attocube systems explore your nanoworld

Add CLUE to your SEM. High-efficiency CL signal-collection. Designed for your SEM and application. Maintains original SEM functionality

5. Lithography. 1. photolithography intro: overall, clean room 2. principle 3. tools 4. pattern transfer 5. resolution 6. next-gen

Zero Focal Shift in High Numerical Aperture Focusing of a Gaussian Laser Beam through Multiple Dielectric Interfaces. Ali Mahmoudi

Hybrid Integration Technology of Silicon Optical Waveguide and Electronic Circuit

Sensitive measurement of partial coherence using a pinhole array

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Dynamic Phase-Shifting Microscopy Tracks Living Cells

Education in Microscopy and Digital Imaging

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Aberrations and adaptive optics for biomedical microscopes

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Fast Laser Raman Microscope RAMAN

Radial Polarization Converter With LC Driver USER MANUAL

Very short introduction to light microscopy and digital imaging

RECENTLY, using near-field scanning optical

Instruction manual and data sheet ipca h

Figure 3.4 Approximate size of various types of cells. ~10 um. Red Blood Cells = mm 1500 um. Width of penny Pearson Education, Inc.

An Optical Characteristic Testing System for the Infrared Fiber in a Transmission Bandwidth 9-11μm

Chapter 1. Basic Electron Optics (Lecture 2)

You won t be able to measure the incident power precisely. The readout of the power would be lower than the real incident power.

MicroSpot FOCUSING OBJECTIVES

Rates of excitation, emission, ISC

SUPRA Optix 3D Optical Profiler

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

LSM 510 META in Chang Gung University

Coherent Laser Measurement and Control Beam Diagnostics

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

plasmonic nanoblock pair

Supplementary Information for. Surface Waves. Angelo Angelini, Elsie Barakat, Peter Munzert, Luca Boarino, Natascia De Leo,

NanoFocus Inc. Next Generation Scanning Probe Technology. Tel : Fax:

Technical Explanation for Displacement Sensors and Measurement Sensors

Low Voltage Electron Microscope

INTERFEROMETER VI-direct

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

LVEM 25. Low Voltage Electron Mictoscope. fast compact powerful

Fiber Optics. Laboratory exercise

MSE 595T Transmission Electron Microscopy. Laboratory III TEM Imaging - I

The DCS-120 Confocal Scanning FLIM System

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

Transcription:

APPLICATION NOTE M01 attocfm I for Surface Quality Inspection Confocal microscopes work by scanning a tiny light spot on a sample and by measuring the scattered light in the illuminated volume. First, the resolution obtained is better in comparison with the microscope operated conventionally, since a pinhole removes the out-of-focus information. Second, by scanning many thin sections through a sample, one can build up a very clean three-dimensional image of the sample. Finally, the non-contact method prevents from destruction or degradation of the sample. Because confocal microscopy is a three-dimensional, high-resolution, and non-destructive tool, it is ideal for high resolution defect analysis and topography profiles (examples are shown in the pictures on the right). Fig. 1: Confocal picture of GaAs-substrate: Inspection of a cleaved surface; the size of the image is 20 x 20 microns. The highly modular and flexible attocfm I features fully adjustable excitation and collection ports enabling easy handling and filtering of the excitation and collection signal for raman spectroscopy. The attocfmiopens up new possibilities in quantitative surface characterization in the micron / sub-micron range. Fig. 2: Confocal picture of a chess board grating (SiO 2 on Si) with a period of 2 microns, recorded in reflection mode. The sample has some defects on the surface structure. Fig. 4: Complete attocfm system and the head. Fig. 3: The aluminum on glass grating is damaged at certain locations. Left: size 30 x 30 microns; right: size 45 x 45 microns. attocfm I ANPxyz100/LT attoscan attoview highly modular and flexible inertial positioner for big loads high precision piezoelectric data viewing software

APPLICATION NOTE M03 3D - Imaging with attocfm II The confocal imaging system achieves out-of-focus rejection by two strategies: By illuminating a single point of the specimen with a focused beam, so that illumination intensity drops off rapidly above and below the plane of focus. By the use of a blocking pinhole in the conjugate plane of the previous plane of focus in order to eliminate the degrading out-of-focus information. By scanning many thin sections through your sample, you can build up a very clean three-dimensional image of the sample. Confocal imaging can offer another advantage in favourable situations (small pinhole size, bright specimen): the resolution obtained is better than the resolution obtained with any microscope operated conventionally. In practice, the best horizontal resolution of a is (at λ=630 nm illumination) about 200 nm, and the best vertical resolution is less than 500 nm. Fig. 1: Confocal picture of a chess board with 2 microns of period recorded in reflection mode. Fig. 3: The attocfm II microscope sensor head. Fig. 2: Confocal picture of a tweezers structure; the tweezers are freely suspended. The size of the image is 30x30 microns recorded in reflection mode. The 200 nm wide structures are resolved with an excitation laser source of 630 nm! (C. Meyer et al., IEEE Nano 2004). attocfm II ANPxyz100/LT attoscan attoview highly stable and compact inertial positioner for big loads high precision piezoelectric data viewing software

APPLICATION NOTE 10G Vibrations of the system The vibrations of the complete system including the cryostat and the were recorded at different temperatures and with the cooler on and off. Figure 1 (top) illustrates the vibrations as a function of time recorded at 4 K with the cooler on. The corresponding vibration spectrum recorded under the same conditions is shown in Figure 1 (bottom). The vibrations corresponding to the operating frequency of the cooler were typically below 10 nm. Performing the same experiment at 300 K showed vibrations in the range of 25-30 nm (data not shown). The vibrations as a function of the time recorded at 4 K with the cooler switched off are shown in Figure 2 (top). In this case, the vibrations corresponding to the operating frequency were determined to be below 5 nm. Figure 2 (bottom) illustrates the vibration spectrum recorded under the same conditions. Confocal imaging The attocfm II is an ultra-compact which is highly stable at low temperatures, high magnetic fields and in high vaccum. A laser beam is coupled into one arm of a 50/50 single mode optical fiber coupler. The fiber end of the second arm is placed in a ceramic ferrule, to guarantee an accurate position with respect to the objective and to minimize optical aberrations. This single mode fiber illuminates the sample and is used as the blocking pinhole aperture when collecting the scattered light from the sample. The mechanical parts are highly stable against thermal drift and the design is optimized to minimize light losses as well as to collect the maximum amount of light scattered by the illuminated point on the sample. Figure 1: Vibrations (top) and vibration spectrum (bottom) of the complete system ( inside the cryostat) recorded at 4 K with the cooler on. The images in Figure 3 were recorded with the attocfmii in reflection mode. The illumination wavelength was chosen to be 1330 nm. As a sample, a SiO 2 on Si grating with a period of 4 µm and a chess board with a period of 2 µm was used. The image on the left was recorded at 300 K with the cooler on. The sample features are clearly resolved despite the higher vibrations at this temperature. The other two images were recorded at low temperature (4 K) with the cooler running (middle) and switched off (right). Due to the low vibrations of the cryostat and the highly stable microscope, absolutely stable measurements over several hours were enabled. Furthermore, fast cycle times and easy, cryogen- free handling add to the simplicity of this complete low temperature confocal microscopy system. 300 K cooler on Figure 2: Vibrations (top) and vibration spectrum (bottom) of the complete system ( inside the cryostat) recorded at 4 K with the cooler off. 4 K cooler on 4 K cooler off Figure 3: (left) CFM image of a SiO 2 on Si sample recorded at 300 K with the cooler on. The grating has a period of 4 µm and the chess board a period of 2 µm. The step scan range is 30 x 30 µm. (middle) CFM image of a SiO 2 on Si chess board sample recorded at 4 K with the cooler on. The chess board has a period of 2 µm. The step scan range is 10 x 10 µm. (right) CFM image of a SiO 2 on Si chess board sample recorded at 4 K with the cooler off. The chess board has a period of 2 µm. The step scan range is 10 x 10 µm. 2005 VeriCold Technologies GmbH attocube systems AG, Viktualienmarkt 3, D-80331 München, Germany, www.attocube.com, Tel. +49 (0)89 2420 8888, Fax. +49 (0)89 2420 8890 VeriCold Technologies GmbH, Bahnhofstr. 21, D - 85737 Ismaning, www.vericold.com, Tel. +49 (0)89 9699 8560, Fax-: +49 (0)89 9699 8569

APPLICATION NOTE M13 Confocal Microscopy in Combination with a Solid Immersion Lense for Enhanced Resolution Confocal microscopy provides several advantages over conventional wide field optical microscopy including elimination of image degrading out-of-focus information and the ability to acquire serial optical images in successive thin sections from thick specimen. Confocal microscopy relies on wo strategies: a) Illumination of a single point of the specimen at a time with a focused beam so that the illumination intensity drops rapidly above and below the plane of focus and b) using a blocking pinhole aperture in a conjugate focal plane to the specimen eliminating degrading out-of-focus information. Solid immersion microscopy, where light is focused inside a high refractive-index lens close to a sample, offers a method for achieving resolution well below the diffraction limit in air. Combining these techniques, major improvement of resolution and light throughput are achieved in addition to offering a very simple experimental setup compared to other high resolution optical techniques, e.g. scanning near-field optical microscopy (SNOM). In the confocal setup, the solid immersion lens is applied directly on the surface of the investigated sample, which was a SiO 2 on Si chess board with two microns in period. A schematic drawing of the experimental setup is shown in Figure 1. The attocfm II was used first to acquire an image of a sample without the solid immersion lens, and second, to acquire an image with the solid immersion lens. The purpose is to determine the increase in the resolution. The wavelength used was 635 nm. The diffraction limited confocal objective had a numerical aperture of 0.55, thus leading to a lateral resolution of 700 nm. Figure 2 shows the image and a line cut recorded without the solid immersion lens. The micrometer sized structures are clearly resolved. Figure 3 shows the image acquired using the solid immersion lens. The measured resolution was about 160 nm. This ultra-high resolution is also attributed to the confocal setup using a pinhole that leads to an additional enhancement of the resolution. Figure 2: 3D-view and line cut of the image acquired with the attocfm II. The sample is a chess board with 2 microns in period. Figure 1: Schematic drawing of the attocfm II setup including the solid immersion lens. Figure 3: 3D-view and line cut of the image acquired with the attocfm II in combination with the solid immersion lens. attocfm II ANPxyz100 attoscan attoview highly stable confocal microscope inertial positioner for big loadsanhigh precision piezoelectric data viewing and editing software

nanotooling Solutions for extreme Environments APPLICATION NOTE PS03 Compact integrated into the attouhvchamber. Based on the design of the attocube s low temperature compatible attocfm I a setup has been integrated into the attouhvchamber. The tests show superior performance of the optical microscope while enabling an easy optical access for sensitive applications such as Bose-Einstein Condensates, the detailed characterization of waveguides. The measurements have been performed using a standard confocal head together with a special lens setup for the attouhvchamber. The optical beam from the confocal setup was guided into the UHV chamber though an optical broadband window. A laser with a 635 nm wavelength and a UHV compatible objective with the following properties have been used: focal length of 1.56 mm and an NA of 0.68 which results in a theoretical spot size of ~ 600 nm and resolution of at best ~ 450 nm. The confocal head and the objective were stationary, while the sample was mounted on an ANPxyz101 positioner set for coarse alignment in combination with an for scanning purposes. The sample was a standard chess board structure with ~ 60 nm high SiO 2 structures on Si substrate with 2 µm periodicity. The whole setup was at room temperature and UHV conditions, with the pressure less than 1E-9 mbar. Fig. 1: Image of the chess-board grating with 2 µm periodicity. Red corresponds to high, black to low intensity. From the graph, one can see that the spot is very good circular. In Figure 1 the result of the measurement is shown. The image shows clearly the periodicity of the grating at good contrast. Additionally, the image shows that the circular spot size of the setup has no distortions or aberrations. In summary, it has been shown that the attouhv chamber can be easily combined with the confocal attocfm I setup with no compromises on the quality of the measurement. Fig. 2: Image of the chess-board grating with 2 µm periodicity.??????????????????????????????????????????????????????????????????????????????????????????????????? attouhvchamber attocfm I ANPxyz101/UHV ANC150 miniaturized UHV chamber inertial positioners attocube systems AG, Königinstrasse 11 A (Rgb), D-80539 München, Germany, www.attocube.com, Tel. +49 (0)89 2877 809-0, Fax. +49 (0)89 2877 809-19. attocube systems AG 2001-2009 All rights reserved.