Series Adjustable Height Tables

Similar documents
Series 7 AdjusTable Height Tables

Series 7 - Adjustable Height Tables

FitWork Walkstation Series 7 AdjusTables

Single Sided Height Adjustable Benching

Height Adjustable Benching End Panel and Utility Pole

FlexFrame - Storage Components and Skins

UPLIFT 2-Leg Height Adjustable Standing Desk

434 Cobi Chair - Seat Shell Replacement

UPLIFT 3-Leg Desk Instructions for. Solid Wood Desktops. pictured: 3-leg desk; solid-wood top, with right hand return TABLE OF CONTENTS

Series 9000 Panel Door; In-Line, Corner and Permanent Wall Application

UPLIFT 2-Leg Height Adjustable Standing Desk - For use with UPLIFT Eco and Eco Curve desktops -

c:scape Shared Tables - Freestanding and Tethered

MY-HITE CORNER ADJUSTABLE TABLE

MY-HITE ADJUSTABLE TABLE

MultiTable Mod-E 2 Electric Standing Desk

UP tables & worksurfaces

Answer Power Beam and Boundary Screen

Assembly Instructions

Mod-E Pro Electric L-Shaped Standing Desk

UPLIFT Height Adjustable Standing Desk 3-Leg (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE

PROFILE Flat Panel Console System Installation Manual

Privacy Wall Glass Selections - Polished Edge Slider Door

TRIUMPH-LX ELECTRIC TABLE BASE

487 Cachet Swivel - Base Chair Replace Front Seat Support or Seat

Opus Standard Corner Trim Unit

imove-f Assembly Manual (Motorized Version-M1/M2)

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

Jenny Legs Assembly Instructions

Linear Hook- on Worksurfaces

IMPULSE G2/PULSE STATIC BRIDGE & RETURN MODULE. Drill. Desk Connecting. Outside by fastening the supplied wood screws from the HK-67 kit through the

488 Brody Disassembly Direction

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

a.k.a. casegoods instructions

Large Case Storage - Counterweights

Topo Freestanding Applications - Private Office

Pathways Privacy Wall Glass Selections - Sliding Door

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

OPower cord meters

Endeavour 3 Leg Adjustable Height Desk. UL Number: E MANUAL FOR ASSEMBLY AND USE

Hover. Installation Instructions. Raised Panel. Version

Assembly Instructions & General Overview

FLT-02 User Manual. Contents. Page 2 Page 3 Page 4 Page 5-7 Page 8

IMPULSE G2/PULSE STATIC BRIDGE & RETURN MODULE. Drill. Desk Connecting. Outside by fastening the supplied wood screws from the HK-67 kit through the

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

110 and 555 Markerboard, Chalkboard and Tackboard Mounting

Premium Whiteboard and Tackboard Mounting

KINEX benching Installation Guide

Wall Mount Assembly and Mounting Guide (55 /84 )

bridges Installation Manual

Workbench Instructions for Assembly

Groupwork Tables. Table of Contents. Page Topic. Page 1 of Rev G

Figure A. Figure B. Figure C. Figure D

Motorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions

STAKS. Crossover Casegoods ASSEMBLY INSTRUCTIONS

TechBench Installation Manual

Jarvis standing desk. Assembly instructions. For assembly assistance, visit fully.com/howtojarvis or call or

ApexDesk Assembly Guide

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

MY-HITE ADJUSTABLE TABLE

Opus Base Unit Assembly

NewHeights Presidente Reception Assembly Instructions Warranty: raproducts.com/warranty

Range height adjustable assembly

APTOS DUOFOIL LEGS DRILL 1/8" DRILL BIT. Rev: Dwg: DUOFOIL LEGS DRILL DUOFOIL LEGS AT A 45 ANGLE TO EDGE OF TOP WITH WIRE CAVITY

Worktop INDEX eight Capacity Unpacking

Laminate Cabinet Installation Instructions

40"- 61" Electric Height Adjustable Desk Frame

TABLE OF CONTENTS REQUIRED TOOLS

SeeMeCNC Guides. Step 2. REV2 Rostock Max v3 Base Assembly. Second edition Rostock Max v3 assembly guide. Written By: JJ Johnson

Wall mounting bracket

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

ShorePort PWC Lift Instructions " x 138" Sandstone ShorePort " x 138" White ShorePort " x 138" Tan ShorePort

JEEP JK ( 5 DOOR ) SLIMLINE II - FULL TRAY EXTREME RACK KIT

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B

media:scape HDVC Wall Mount

TITAN INDUSTRIAL RACK 4-FOOT TALL / 3-SHELF

TITAN INDUSTRIAL RACK 6-FOOT TALL / 4-SHELF

MY-HITE ADJUSTABLE TABLE

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Stainless Steel Bench Stand

LCD DISPLAY MOUNT

Workbench Instructions for Assembly

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved


Arlink 8000 Workstation

Qwik-Fence Installation Instructions

Video Wall Installation Instructions 2W X 3H, 3W X 3H

C-Leg Electric Height Adjustable Tables

Bend-Tech Dragon Assembly Manual

Side Winder R o u t e r L i f t.

RANGE DIGITAL HANDSET OPERATION. 1. Panel. 2. Initialization Procedure. 3. Move Up & Down. 4. Set Memory Positions. 5. Move to the Memorized Positions

Parts Included: T-Feet Assembly

installation guide Footer & Base Plate Assembly KINEX Installation Guide SINGLE RUN

NewHeights Series 4 Bonita ET 3-Leg Workstation Warranty: raproducts.com/warranty

TRUE TECHNICAL SERVICE MANUAL - ALL MODELS. DOORS/DRAWERS/LIDS

Product must be installed as shown using the screws and brackets provided. Use of incorrect hardware could result in damage to the product.

Mirage Installation Manual

FLEXRISE2 VERSION. 2 LEG / 2 MOTOR ELECTRIC TABLE BASE (36 to 72 ) **PATENT PENDING**

WEIGHT ADJUSTABLE ESPREE. Model 2ESP-WA-C48- Model 2ESP-WA-C60- 2ESP-WA Rev B 8/17 ASSEMBLY AND OPERATION

ACCESS COVER INSTALLATION INSTRUCTIONS (Kit #601 for 2006 Honda Ridgeline)

Series Assembly Instructions

Transcription:

Series 7.2 - Adjustable Height Tables Tools required: Power Drill #2 SQUARE DRIVE BIT If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for immediate action by people who want to help you. (Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.247.2500) Or visit our website: www.steelcase.com 2015 Steelcase Inc. Grand Rapids, MI 49501 U.S.A. Printed in U.S.A. Page 1 of 20

When using an electrical furnishing, basic precautions should always be followed, including the following: Read all instructions before using (this furnishing). IMPORTANT SAFETY INSTRUCTIONS DANGER - To reduce the risk of electric shock: 1. Always unplug this furnishing from the electrical outlet before cleaning. WARNING - To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Unplug from outlet before putting on or taking off parts. 2. Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons. 3. Use this table only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. 4. Never operate this table if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. 5. Keep the cord away from heated surfaces. 6. Never drop or insert any object into any opening. 7. Do not use outdoors. 8. Do not operate where aerosil (spray) products are being used or where oxygen is being administered. 9. For loading always put heavier items at the bottom and not near the top in order to help prevent the possibility of the furnishing tipping over. SAVE THESE INSTRUCTIONS The power socket/outlet shall be installed near the equipment and shall be easily accessible. It is the responsibility of the user to purchase and use a line filter (style number A7FILTER) to supply power to the Chevron 7.2 Table control box. This must be installed to meet EMC certification requirements. Page 2 of 20

TABLE OF CONTENTS: PAGE(S): Lets Get Started!... 4 Attaching Stretchers... 5 Mounting Legs to Worksurface... 6 & 7 Attaching Control Box & Wire Managers... 8 & 9 Connecting & Routing Cables... 10 & 11 Attaching the Controller... 12 & 13 Finishing the Leg Installation... 14 Finishing the Table Assembly... 15 & 16 Guidelines on Moving the Table... 17 Wiring Guide... 18 Appendix A: 2-Piece Worksurface Assembly... 19 & 20 Overview of Assembly Process 1) Determine the table configuration. 2) Assemble 2-piece worksurface (if applicable). 3) Assemble and attach stretchers. 4) Attach legs to worksurface (with worksurface upside-down). 5) Attach control box and wire managers. 6) Connect and route cables. 7) Attach the contoller. 8) Check for binding and finish leg attachment. 9) Flip table upright and test function. 10) Level and clean it up. 11) PLEASE LEAVE THESE INSTRUCTIONS, AND THE USER GUIDE, IN AN OBVIOUS PLACE FOR THE END USER AFTER ASSEMBLY. Page 3 of 20

Let's Get Started! 1 Prepare a large open space to assemble the table. Sweep the floor! Screws and small parts can damage the worksurface. 3 Assembling a 90 o corner table with a 2-piece worksurface? Jump to Appendix 'A' now. Put down a CLEAN shipping blanket to protect the worksurface. 3 1 2 Unpack the worksurface and place on the shipping blanket upside-down. REMEMBER - You're looking at the UNDERSIDE of the worksurface. Are you sure which side is left or right? 2 Page 4 of 20

Attaching Stretchers STRETCHER 4 Layout the left and right stretcher assembly and the center connector with the dovetails pointing down. Loosely install the center connector to the left and right stretcher using two (2) 1/4-20 type F flat head screws with phillips #3 drive...do not tighten. (Left and right is determined when the table is standing on the base and is viewed from the front.) NOTE: A clean, abrasion free surface will be necessary for table assembly. DOVETAIL STRETCHER LEFT LIFTING COLUMN RIGHT LIFTING COLUMN 5 Layout the left, right (and center if applicable) lifting columns, place the stretcher into each dovetail, connect loosely. Left & right is determined from the end-users point of view. TOP VIEW LIFTING COLUMN STRETCHER DOVETAIL 6 Once each lifting column has been engaged, lightly tap each connection point with a rubber mallet 1/8-1/4 inch at a time, until completely seated. Do not completely install one lifting column at a time...they must be installed incrementally. RIGHT LIFTING COLUMN CENTER LIFTING COLUMN STRETCHER LEFT LIFTING COLUMN Page 5 of 20

Mounting Legs to Worksurfaces For 2-Leg Tables: 7 With the top still upside down on the floor, turn the base over (flipping is a 2 person job), and align the attachment plates to the pre-drilled holes in the top. MOTOR HOUSING IS ALWAYS AT FRONT OF LEG Loosely install one fastener in each of the pre-drilled pilot holes. Don't install all fasteners until the unit has been operated through one cycle (Step 14). Mounting Plate Worksurface Pilot Holes = PILOT HOLE = NO PILOT HOLE PROVIDED SQUARE DRIVE SCREW Page 6 of 20

Mounting Legs to Worksurfaces (cont.) For 3-Leg Tables: 7 With the top still upside down on the floor, turn the base over (flipping is a 2 person job), and align the attachment plates to the pre-drilled holes in the top. For 3-leg tables, align the center lifting column first. Center each pre-drilled hole in the top to the slot in the attachment plate. Loosely install one fastener in each of the pre-drilled pilot holes. Once the center lifting column is secured, align the left and right lifting columns in a similar fashion by moving the plate so that all pre-drilled holes are visible. Don't install all fasteners until the unit has been operated through one cycle (Step 14). NOTE: Do not force the left or right lifting columns to perfectly fit the attachment mounting holes. This can cause binding during articulation. SQUARE DRIVE SCREW Page 7 of 20

Attaching Control Box & Wire Managers 8 Install control box in the predetermined location, using pre-drilled holes. CONTROL BOX 9 Install the wire managers to the underside of the worksurface. Be sure to allow space for wires to bend gently without getting kinked, and space for accessories to clamp onto the back edge of the worksurface. WIRE MANAGER Page 8 of 20

Attaching Control Box & Wire Managers (cont.) 10 For 3-leg tables, place one wire manager on each side of the table. Install the wire managers to the underside of the worksurface as shown. Be sure to allow space for wires to bend gently without getting kinked, and space for accessories to clamp onto the back edges of the worksurface. WIRE MANAGER Page 9 of 20

Connecting & Routing Cables For 2-Leg Tables: 11 Connect the cables to each lifting column and connect the terminal end to the control box. Route these cables in the wire management cableway provided. Refer to the Wiring Guide for more information on page 18. For optimal wire management, connect lifting columns to the closest port on the control box. PORT #1 PORT #2 Page 10 of 20

Connecting & Routing Cables (cont.) For 3-Leg Tables: 11 Connect the cables to each of the three lifting columns and connect the terminal end to the control box. Route these cables in the wire management cableway provided. (2000mm cables to the left and right lifting columns & 1000mm cable to the center lifting column.) Refer to the Wiring Guide for more information on page 18. For optimal wire management, connect lifting columns to the closest port on the control box. PORT #1 PORT #2 PORT #3 Page 11 of 20

Attaching the Controller 12 Install the controller to the underside of the worksurface on the side preferred by the user. (We recommend it be placed toward the outside of the table to avoid interference in the workspace.) Push Button Stick-On Controller NOTE: Push button stick-on controller installation is shown here. However, the controller cannot be installed until the worksurface is flipped over. Once step 16 is performed, the controller may then be installed. NOTE: Remove paper backing from contoller before installation. Standard Controller Digital Desk Panel Controller Page 12 of 20

Attaching the Controller (cont.) PAPER BACKING 13 Install the wire keepers for the control wire. Peel off paper backing and stick to worksurface. Place wire into each wire keeper. WIRE KEEPER CONTROL WIRE Page 13 of 20

Finishing the Leg Installation SQUARE DRIVE SCREW 14 Plug unit in and check for binding, by running the table base all the way through its range of motion and back again, then lower to bottom and unplug unit. Install the remaining fasteners in each of the remaining holes and tighten ALL screws securely. Do not over tighten. CONTROL BOX PLUG SQUARE DRIVE SCREW NOTE: Leg removed from illustration for clarity. Page 14 of 20

Finishing the Table Assembly 15 Carefully turn the table over (2 person operation). NOTE: Do NOT use either lifting column as a brace when turning the table over, as thismay cause binding. The top must be lifted free, rotated, and set down carefully. 17 Connect power cord to power supply. CAUTION: Be sure to create a 'drip loop' in the power cord before making the connection to a live wall socket, to prevent electric shock if liquids spill on power cord. 16 After the table is in place, install the 120v plug into the control box. Secure the cord to the control box using the molded-in clip. Plug the cord into an outlet. 18 Route all cables through wire managers. Keep all cables clear of moving parts! CONTROL BOX PLUG MOLDED CLIP Page 15 of 20

Finishing the Table Assembly (cont.) 19 Before use, the table must be completely leveled, front-to-back and side-to-side using the height adjustable glides. Failure to do this could cause the lifting columns to bind. 20 Before articulation, you must synchronize the lifting columns as outlined below. NOTE: Mounting of CPU and CPU holders: Maximum height for the 2 units cannot exceed 20-1/2". Synchronizing the Lifting Columns Prior to initial use of the height adjustment function you must "synchronize the system". Press the Down arrow until the worksurface comes to a stop at the lowest position. Release the Down arrow. Press and hold the down arrow for approximately 5 seconds while the table synchronizes itself. The surface will quickly lower itself approximately 5mm then rise approximately 5mm and finally settle back to its lowest position. Standard Controller Digital Desk Panel Controller GLIDE After performing this function, the movement of all lifting columns is synchronized by software inside the control box. In the unlikely event that an error occurs, reset the control unit by pressing the Up and Down buttons at the same time for 5 seconds. Then repeat the synchronizing sequence as previously outlined above. Push Button Stick-On Controller Page 16 of 20

Guidelines on Moving the Table 1 2 3 4 When possible, the table should be moved in a horizontal (flat) position. If the table must be moved vertically (i.e. standing on a pallet), care must be taken to ensure no side pressure is placed on any of the lifting columns as it is tipped into position, during transport, and when tipped off the pallet at the new location. Before in use in the location, the table must again be completely leveled side-to-side and front-to-back. Failure to do so may cause binding of the lifting columns and failure to operate properly. After moving, the lifting columns must be re-synchronized by holding 'down' arrow on the Controller while the lifting columns seek to level themselves. CENTER LIFTING COLUMN DRAW BOLTS RIGHT STRETCHER LEFT STRETCHER V-BRACKETS RIGHT LIFTING COLUMN LEFT LIFTING COLUMN WIRE MANAGEMENT CABLEWAY WORKSURFACE TOP CONTROLLER (can be positioned on left or right side) Page 17 of 20

Wiring Guide 1 2 3 4 When connecting cables as stated in Step 8, use this guide as a reference. Connect the cables from the Lifting Columns to the cables provided. The other end should be connected to the Control Box. Repeat this for each leg. Connect the end of the Controller cable into the Control Box. Follow Steps 9-11 to complete the wiring installation. Never attach wires to the legs or stretcher in any way. 5 Once you have completed the wiring, use the Wire Managers to hold all the cables and minimize possible entanglements. NOTE: Vertical wire management solutions are also available from Details. Contact your local dealer or Steelcase.com for more information. RIGHT LIFTING COLUMN FOOT GLIDES CONTROL BOX LEFT LIFTING COLUMN ATTACHMENT PLATE CONTROLLER Page 18 of 20

Appendix A: 2-Piece Worksurface Assembly 1 1 Position top pieces upside down on the assembly surface and align with wood spline (or biscuits) provided. Optional Biscuits SPLINE DRAW BOLTS SCREWS V-CHANNELS 2 Install draw bolts and tighten with 5/16" or 7/16" open end wrench. Attach two (2) v-channels using sixteen (16) screws per channel. 2 Page 19 of 20

Appendix A: 2-Piece Worksurface Assembly (cont.) Special Notes on 2-Piece Worksurfaces Overhangs: The extension portion of 2-piece worksurfaces may not completely overhang the supporting leg! One leg must always be fully mounted to the extension portion. CORRECT! Planar Alignment: The spline or biscuits between the primary and extension portions act to keep the worksurface halves aligned on the top surface. If these parts fit loosely, shim them using pieces of paper as shown. CORRECT! WRONG! THIS CONDITION IS NOT ALLOWED! PRIMARY HALF PRIMARY HALF EXTENSION HALF EXTENSION HALF PLANAR MIS-ALIGNMENT SLOT FOLDED SHEETS OF PAPER TO SHIM SPLINE IMPROVED ALIGNMENT Page 20 of 20