Physiology Lessons for use with the BIOPAC Student Lab

Similar documents
Physiology Lessons for use with the Biopac Student Lab

Lesson 8 EOG 1 Electrooculogram. Lesson 8 EOG 1 Electrooculogram. Page 1. Biopac Science Lab

Experiment HM-2: Electroculogram Activity (EOG)

ECG Analysis using the Offline Averaging Mode

Experiment HP-23: Lie Detection and Facial Recognition using Eye Tracking

COMPOUND ACTION POTENTIAL: NERVE CONDUCTION Using the frog sciatic nerve

40 Hz Event Related Auditory Potential

Physics 253 Fundamental Physics Mechanic, September 9, Lab #2 Plotting with Excel: The Air Slide

Experiment HP-1: Facial Electromyograms (EMG) and Emotion

A graph is an effective way to show a trend in data or relating two variables in an experiment.

Adding Content and Adjusting Layers

Learning Guide. ASR Automated Systems Research Inc. # Douglas Crescent, Langley, BC. V3A 4B6. Fax:

The introduction and background in the previous chapters provided context in

Experiment P55: Light Intensity vs. Position (Light Sensor, Motion Sensor)

MicroLab 500-series Getting Started

Laboratory 1: Motion in One Dimension

SMALL VOLUNTARY MOVEMENTS OF THE EYE*

APPLICATION NOTE. Overview

BIO 365L Neurobiology Laboratory. Training Exercise 1: Introduction to the Computer Software: DataPro

Android User manual. Intel Education Lab Camera by Intellisense CONTENTS

Sonoma State University Department of Engineering Science Spring 2017

CSE Thu 10/22. Nadir Weibel

2 Oscilloscope Familiarization

Human-to-Human Interface

Precalculations Individual Portion Introductory Lab: Basic Operation of Common Laboratory Instruments

Quick Start Guide for the PULSE PROFILING APPLICATION

APPLICATION NOTES. This complete setup is available from BIOPAC as Programmable Stimulation System for E-Prime - STMEPM

Laboratory Project 1B: Electromyogram Circuit

Step 1: Set up the variables AB Design. Use the top cells to label the variables that will be displayed on the X and Y axes of the graph

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 10. Electronic Circuits

Human Finger Twitch Experiment Using Finger Twitch Transducer

LO - Lab #06 - The Amazing Human Eye

Application Note 175 Using the STMISOC Stimulus Isolator

Experiment 8: An AC Circuit

Objectives. Abstract. This PRO Lesson will examine the Fast Fourier Transformation (FFT) as follows:

Name: First-Order Response: RC Networks Objective: To gain experience with first-order response of RC circuits

Physics 131 Lab 1: ONE-DIMENSIONAL MOTION

Faraday's Law. Objective: In today's experiment you will investigate electromagnetic induction and determine the factors that affect it.

Activity P52: LRC Circuit (Voltage Sensor)

Experiment P01: Understanding Motion I Distance and Time (Motion Sensor)

Off-line EEG analysis of BCI experiments with MATLAB V1.07a. Copyright g.tec medical engineering GmbH

Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Objectives:

Experiment HN-12: Nerve Conduction Velocity & Hand Dominance

DRCR.net Image Acquisition Protocol

MACCS ERP Laboratory ERP Training

Experiment P02: Understanding Motion II Velocity and Time (Motion Sensor)

Experiment 15: Diode Lab Part 1

Experiment P10: Acceleration of a Dynamics Cart II (Motion Sensor)

BANTAM INSTRUMENTS SOFTWARE USER S MANUAL MIL-STD-461E PRE-COMPLIANCE MEASUREMENT SYSTEM MODEL EMC-461. Model EMC-461 Software User s Manual

Introduction to Oscilloscopes Instructor s Guide

EENG-201 Experiment # 4: Function Generator, Oscilloscope

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

Lab 3: RC Circuits. Construct circuit 2 in EveryCircuit. Set values for the capacitor and resistor to match those in figure 2 and set the frequency to

Introduction.

Introduction to oscilloscope. and time dependent circuits

Lab 15: Lock in amplifier (Version 1.4)

Experiment 13: LR Circuit

Operating Rausch ScanCam within POSM.

Momentum and Impulse. Objective. Theory. Investigate the relationship between impulse and momentum.

Installation Guide. Suitable for: OEM Integration OEM Installation Retro Fit Installation

Activity P07: Acceleration of a Cart (Acceleration Sensor, Motion Sensor)

Surface Potential Surveys Training Manual DA Meter Version

Anna Gresham School of Landscape Design. CAD for Beginners. CAD 3: Using the Drawing Tools and Blocks

Part I. Circuits & Ohm s Law

the human chapter 1 Traffic lights the human User-centred Design Light Vision part 1 (modified extract for AISD 2005) Information i/o

PHY152 Experiment 4: Oscillations in the RC-Circuits (Measurements with an oscilloscope)

Detrum GAVIN-8C Transmitter

The oscilloscope and RC filters

Excel Lab 2: Plots of Data Sets

PHYSICS 326 LAB # 1: The Oscilloscope and Signal Generators 1/6

Sound Waves and Beats

CHM 109 Excel Refresher Exercise adapted from Dr. C. Bender s exercise

EXPERIMENT 5 Bioelectric Measurements

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

P202/219 Laboratory IUPUI Physics Department THIN LENSES

Activity P56: Transistor Lab 2 Current Gain: The NPN Emitter-Follower Amplifier (Power Output, Voltage Sensor)

MASSACHUSETTS INSTITUTE OF TECHNOLOGY /6.071 Introduction to Electronics, Signals and Measurement Spring 2006

1. INTRODUCTION: 2. EOG: system, handicapped people, wheelchair.

2-Axis Force Platform PS-2142

Overview of Teaching Motion using MEMS Accelerometers

DC and AC Circuits. Objective. Theory. 1. Direct Current (DC) R-C Circuit

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

Conversational CAM Manual

Getting started with. Getting started with VELOCITY SERIES.

SPECTRALIS Training Guide

Experiment P41: Induction Magnet through a Coil (Photogate, Voltage Sensor)

Computer Tools for Data Acquisition

Lab 0: Orientation. 1 Introduction: Oscilloscope. Refer to Appendix E for photos of the apparatus

A3 Pro INSTRUCTION MANUAL. Oct 25, 2017 Revision IMPORTANT NOTES

Subdivision Cross Sections and Quantities

UNIVERSITY OF CALIFORNIA, SANTA BARBARA Department of Electrical and Computer Engineering. ECE 2A & 2B Laboratory Equipment Information

Tutorial 2: Setting up the Drawing Environment

Practicing with Ableton: Click Tracks and Reference Tracks

Existing and Design Profiles

An Example Cognitive Architecture: EPIC

Set-up. Equipment required: Your issued Laptop MATLAB ( if you don t already have it on your laptop)

Sound Wave Measurements using an Oscilloscope and Waveform Generator

Laboratory 2: Graphing

Experiment A8 Electronics III Procedure

Transcription:

Physiology Lessons for use with the BIOPAC Student Lab ELECTROOCULOGRAM (EOG) The Influence of Auditory Rhythm on Visual Attention PC under Windows 98SE, Me, 2000 Pro or Macintosh 8.6 9.1 Revised 3/11/2013 D. W. Pittman, Ph.D. Wofford College Modified from: J.C. Uyehara, Ph.D. Biologist BIOPAC Systems, Inc. William McMullen Vice President BIOPAC Systems, Inc. Vertical Horizontal 42 Aero Camino, Goleta, CA 93117 (805) 685-0066, Fax (805) 685-0067 Email: info@biopac.com Web Site: http://www.biopac.com

I. INTRODUCTION One of the most important functions your eyes can perform is to fix or lock on specific objects. When you fix on an object, you position your eyes so that the image of the object is projected onto your retina at the area of greatest acuity, the fovea. Muscular control of your eyes works to keep the image on your fovea, regardless of whether the object is stationary or moving. There are two primary mechanisms used to fixate on objects in your visual field, defined as the field of view, without moving your head: 1. Voluntary fixation mechanism Voluntary fixation allows you to direct your visual attention and lock onto the selected object. 2. Involuntary fixation mechanism Involuntary fixation allows you to keep a selected object in your visual field once it has been found. In voluntary types of eye movements, you can fixate on another person from across a crowded room. Voluntary fixation involves a conscious effort to move the eyes. This mechanism is used to initially select objects in your visual field, and once selected, your brain hands off the task to involuntary fixation. Even when you fixate on a stationary object, your eyes are not still but exhibit tiny, involuntary movements. There are three types of involuntary movements: tremors, slow drifts, and flicking: Ø Tremors a series of small tremors of the eyes at about 30-80 Hz (cycles/sec). Ø Slow drifts involuntary movements that result in drifting movements of the eyes. This drift means that even if an object is stationary, the image drifts across the fovea. Ø Flicking movements As the image drifts to the edge of the fovea, the third involuntary mechanism causes a reflex flicking of the eyeball so that the image is once again projected onto the fovea. The drifting movements and flicking movements will be in opposite directions. If the drifting movement is to the left, the flicking movement will be to the right, although it may not be 180 opposite of the drifting movement. When you wish to follow a moving object, you use large slow movements or tracking movements. So, as you watch Humphrey Bogart walk away during the final scene of Casablanca, your eyes are following an apparently smooth motion and tracking an object in your visual field. Although you have voluntarily directed your eyes to Humphrey Bogart, tracking movements are involuntary. Another set of motions is used when you read or when objects are streaming past you, e.g., when you watch the world go by while riding in a train. Rather than a smooth tracking motion, reading usually involves voluntary, larger movements, known as saccades, or fixating on a series of points in rapid succession. When this happens, your eye jumps from point to point at a rate of about three jumps per second. During the jumps or saccades, the brain suppresses visual images, so you don t see the transitional images between the fixation points. Typically, the eye will spend about 10% of the time moving from fixation point to fixation point, with the other 90% of the time fixating on words, although there is much variation. Eye movement can be recorded as an electrooculogram, a recording of changes in voltage that occur with eye position. Electrically, the eye is a spherical battery, with the positive terminal in front at the cornea, and the negative terminal behind at the retina of the eyeball. The potential between the front and back of the eyeball is about 0.4-1.0 mv. By placing electrodes on either side of the eye, you can measure eye movement up to ±70, where 0 is in front and ±90 is directly lateral or vertical to the eyes. The electrodes measure the changes in potential as the cornea moves nearer or further from the recording electrodes. When the eye is looking straight ahead, it is about the same distance from either electrode, so the signal is essentially zero. When the front of the eyeball, the cornea, is closer to the positive electrode, that electrode records a positive difference in voltage.

II. EXPERIMENTAL OBJECTIVES 1) Measure the reaction time of saccadic eye movements to a visual stimulus when an auditory rhythm is either in synch with the visual stimulus, precedes the visual stimulus, or follows the visual stimulus. 2) Compare the effects of the time intervals (+/-21 or +/-500 ms) for early onset or delay onset of the visual stimulus. III. MATERIALS Ø BIOPAC electrode lead set (SS2L), Qty-2 Ø BIOPAC disposable vinyl electrodes (EL503), 6 electrodes per subject Ø BIOPAC electrode gel (GEL1) and abrasive pad (ELPAD) or Ø Skin cleanser or alcohol prep Ø BIOPAC acquisition unit (MP36) Ø Stimulus sets: Each set contains 36 trials with 12 trials having synchronous tone and visual stimulus, 12 trials visual system moves before the tone, and 12 trials visual stimulus moves after the tone. Within each group of 12 trials, there are three trials for movement to each of the four corners of the screen: Upper Left (UL), Lower Left (LL), Lower Right (LR), and Upper Right (UR). One stimulus set has a time interval of 21 ms during the before and after trials. The second stimulus set has a time interval of 500 ms during the before and after trials.

IV. EXPERIMENTAL METHODS Overview Ø As you complete the Experimental Methods (Set Up, Calibration, and Recording) and the Analysis, you may need to use the following tools and/or display options. The window display shown below is only a reference sample it does not represent any lesson specific data. The sample screen shows 3 channels of data and four channel measurement boxes, but your screen display may vary between lessons and at different points within the same lesson. channel boxes (Data analysis mode only) channel measurement boxes (channel # ) measurement type result) marker marker tools marker label vertical scales channel labels vertical (amplitude) scroll bar horizontal (time) scroll bar horizontal scale selection tool I-Beam cursor zoom tool Ø The symbols explained below are used throughout Experimental Methods and Analysis. Key to Symbols & If you encounter a problem or need further explanation of a concept, refer to the Orientation Chapter for more details. 4 The data collected in the step needs to be recorded in the Data Report (in the section indicated by the alpha character). You can record the data individually by hand or choose Edit > Journal > Paste measurements to paste the data to your journal for future reference. Most markers and labels are automatic. Markers appear at the top of the window as inverted triangles. This symbol is used to indicate that you need to insert a marker and key in a marker label similar to the text in quotes. You can insert and label the marker during or after acquisition by pressing F9. Ø Each section is presented in a two-column format, as described below. FAST TRACK STEPS This side of the lesson (left, shaded column) is the FAST TRACK through the lesson, which contains a basic explanation of each step. DETAILED EXPLANATION OF STEPS This side of the lesson contains more detailed information to clarify the steps and/or concepts in the FAST TRACK, and may include reference diagrams, illustrations, and screen shots.

A. SET UP FAST TRACK Set Up 1. Turn the NEURO6 computer ON and log in as Admin / Psychology1 2. Make sure the BIOPAC unit #2 is OFF before attaching the electrodes. Detailed Explanation of Set Up Steps The desktop should appear on the monitor. If it does not appear, ask the laboratory instructor for assistance. 3. Plug the electrode leads (SS2L) in as follows: Horizontal lead CH 1 Vertical lead CH 2 IMPORTANT Each student is to serve as both the subject and the experimenter in the EOG lab. READ THE ENTIRE INSTRUCTION FOR EACH SECTION BEFORE STARTING THAT SECTION. Horizontal lead plugs into CHannel 1 BIOPAC MP30 unit Vertical lead plugs into CHannel 2 4. Turn the MP30 Unit #2 ON. & Electrode lead sets (SS2L) Fig. 10.1 5. Place 6 electrodes on the Subject as shown in Fig. 10.2. IMPORTANT For accurate recordings, attach the electrodes so they are horizontally and vertically aligned so that the dashed lines on Fig. 10.2 would intersect in the center of your eye s pupil. Right side Left side Set Up continues Fig. 10.2 Proper electrode placement Use the alcohol pads to clean the skin around the eye

6. Attach the vertical electrode lead set (SS2L) from Channel 2 to the electrodes, following Fig. 10.3. where the electrodes will be placed. Let the skin dry before attaching the electrodes. Attach one electrode above the right eye and one below, such that they are aligned vertically. Attach one electrode to the right of the right eye and one to the left of the left eye, such that they are aligned horizontally. The other two electrodes are for ground, and it is not critical that they are aligned. For optimal electrode adhesion, the electrodes should be placed on the skin at least 5 minutes before the start of the Calibration procedure. Note: Because these electrodes are attached near the eye, be very careful when using alcohol to clean the skin. Follow Fig. 10.3 to ensure that you connect each colored cable to the proper electrode. It is recommended that the electrode leads run behind the ears, as shown, to give proper cable strain relief. Vertical BLACK lead (Ground) RED lead WHITE lead Right side Left side 7. Attach the horizontal electrode lead set (SS2L) from Channel 1 to the electrodes, following Fig. 10.4. Setup continues Lead Placement for Channel 2 (Vertical) Fig. 10.3 Follow Fig. 10.4 to ensure that you connect each colored cable to the proper electrode. It is recommended that the electrode leads run behind the ears, as shown, to give proper cable strain relief.

BLACK lead (Ground) RED lead WHITE lead Horizontal Right side Left side 8. Have the Subject adjust the seating position such that his/her chin rests on the box with his/her nose 12 from screen center. 9. Note the distance from the eyes to the center of the computer screen (it should be 12 ). Lead Placement for Channel 1 (Horizontal) Fig. 10.4 The Subject should be positioned such that his/her chin is resting on the box that they are straddling in the chair. The nose should be 12 inches from the screen of the computer screen. It is very important to not move your head during the recording phases. Supporting the head to minimize movement is recommended. Connect the electrode cable clip (where the cable meets the three individual colored wires) to a convenient location (can be on the Subject s clothes). This will relieve cable strain. The Subject should not be in contact with nearby metal objects (faucets, pipes, etc.), and should remove any wrist or ankle bracelets. Note the distance from the eyes to the center of the computer screen (it should be 12 inches. 10. Start the BIOPAC PROGRAM Use the green BIOPAC BSL 4.0 MP36 icon. 11. Choose Create / Record New Experiment 12. Choose Open graph template from disk and select A-EOG- TEMPLATE.gtl 13. Click OK. Find the A-EOG-TEMPLATE.gtl file on the desktop and open it. This ends the Set Up procedure. END OF SET UP

B. CALIBRATION The Calibration procedure establishes the hardware s internal parameters (such as gain, offset, and scaling) and is critical for optimum performance. Pay close attention to the Calibration procedure. FAST TRACK Calibration 1. Make sure the Subject is seated in the same position as directed in Set Up Step 8. Detailed Explanation of Steps Note: It is very important that the Subject does not move his/her head during the calibration procedure. 2. Click on Start the AEOG-21 or AEOG- 500 stimulus program on the desktop. 3. When prompted, enter your assigned subject number choose stimulus 1 or 2 if this is your first (AEOG-21) or second (AEOG-500) stimulus set. 4. Both Experimenter and Subject should read the instructions on the first slide. When done reading the general instructions, click any key to advance to the calibration instructions. 5. Read the calibration instructions and then start the BIOPAC recording and press any key to begin the calibration. 6. Calibration will begin immediately. The Subject should follow the dot on the screen with eyes only. After the calibration press STOP on the BIOPAC recording. Each partner should alternate which stimulus set is run first. Then create a new BIOPAC file for the second stimulus set second. If the prompt box does not appear you may have to find it on the Windows programs bar and click on it. In this experiment, you will fixate your eyes on the black dot in the center of the screen. There will be a series of tones and then the dot will move to one of the four corners of the screen. There are 36 trials. Follow the movement of the dot with your eyes but DO NOT MOVE your head. The subject will press the space bar to start each trial. The experimenter should enter a marker (PRESS F9 key) at the start of each trial and when the dot moves. The experimenter should type number of the trial into the marker window for each movement of the dot (1, 2, 3, 4,..., 36). Please start the BIOPAC recording now and press any key to begin the calibration. In the calibration procedure, you will fixate your eyes on the black dot in the center of the screen. The dot will move to the left, center, right, center, top, center, bottom, center. Follow the movement of the dot with your eyes but DO NOT MOVE your head. Make sure that BIOPAC is recording and press any key to begin the calibration. The Subject should follow the dot around the screen with eyes only and should not move his /her head and should try not to blink during the recording sessions. This procedure will continue for about 10 seconds and will stop automatically. The Experimenter should press stop on the BIOPAC program and check the calibration data according to step #7 below. 7. Check the calibration data: At the end of the 10-sec calibration recording, the screen should resemble Fig. 10.6. Ø If similar, proceed to Data Recording. Ø If different, Redo the calibration.

Calibration continues END OF CALIBRATION Fig. 10.6 There should be fluctuation in the data for each channel. If your data resembles Fig. 10.6, proceed to the Data Recording section. If your data do not look correct then you need to check all recording connections and restart the programs. See Dr. Steinmetz or the lab TAs if you continue to have problems. 8. Run through the 10 trial practice. 9. Begin the experiment. The experimenter should press START on the BIOPAC recording enter a marker (F9) and label it Start EOG-21 or EOG-500 10. The subject should press any key to begin the experiment. Make sure that the experimenter starts the BIOPAC recording before advancing to start the experiment. 11. Press the space bar to start each trial. Keep eyes focused on the dot in the center and follow it when it moves. Go at your own comfortable pace. Try not to blink during the trials. 12. The subject should press any key to begin the experiment. There will be 36 trials. Go at your own pace and try not to blink during a trial. 13. STOP the BIOPAC recording and save the file as SubjectName-50 or SubjectName-250 depending on the stimulus set tested. The experiment will end after 36 trials. The BIOPAC file will NOT automatically save. YOU MUST SAVE YOUR DATA. Take a short break and then repeat for the remaining program AEOG-21 OR 500 using a new BIOPAC file. Start over with Instructions step #1. END OF EXPERIMENT

EOG LAB DATA ANALYSIS INSTRUCTIONS Scroll over to your first stimuli of the data set. Your screen should look something like this: Click once on the x-axis time scale and change the Time Scale to 1 seconds/div. See the box to the left as an example.

Scroll over to locate your first stimulus in the data window. It should look like the below screen shot: Using the select cursor, start at the onset of the marker for the visual stimulus and measure the delta T to the onset of the horizontal saccade (red data line). In this case it is 0.188 seconds (see below). Record this value in the correct cell of the data analysis sheet based on the visual stimulus location marker (in this case UL or upper left) and tone trial marker (in this case before).

You will end up recording 3 trials for each stimulus location for each tone trial option: synch, before, and after for a total of 36 data points. Here is an example of an after LL trial. NOTE: you always measure from the onset of the visual stimulus location marker and NOT from the tone marker.

Repeat this process for the 250 ms stimulus set being careful to note which values belong to the 50 ms set and which values are measuring the 250 ms set. Once you have recorded your values, please save your excel file and copy and paste your values into the correct GOOGLE docs file making sure to put your 50 ms data into the Group 50 ms file and your 250 ms data into the Group 250 ms file. All data must be collected, analyzed, and added to the Google Docs Group Data sheet by the deadline specified on the course lab website.