CD HORIZON REDUCTION MULTI AXIAL SCREW. Spinal System Technical Guide

Similar documents
Optima ZS Spinal Fixation System

Aesculap Spine S 4 Spinal System. Instrumentation Guide

SURGICAL TECHNIQUE. SpineTune THORACO-LUMBAR POSTERIOR OSTEOSYNTHESIS SYSTEM

Vertebral Body Derotation System Guide and Ordering Information

URS Degen. Top loading pedicle screw system for posterior stabilization.

ACLP Anterior Cervical Locking Plate System TECHNIQUE GUIDE

Xia 3 Reference Guide. Version 3-August 2015

Thoracolumbar Solutions. Vitality Spinal Fixation System. Surgical Technique Guide

Surgical Technique. Deformity - Degenerative. Interbody Fusion. Tumour - Trauma. Cervical. Emerging Technology

QUANTUM SPINAL. Presenter: John Perala, Product Manager. August 14, 2006

Pangea Degenerative Spine System. Top Loading Preassembled Pedicle Screw System for Posterior Stabilization of the Thoracolumbar Spine.

S 4. Aesculap. Spinal System. Percutaneous Approach Surgical Technique. Aesculap Spine

Top Loading Pedicle Screw and Hook System for Posterior Stabilization. URS System. Surgical Technique

Surgical Technique ANAX TM OCT. Spinal System

BLACKBIRD Spinal System

Anterior Cervical Plate SURGICAL TECHNIQUE GUIDE. Surgeon Driven Innovation

Technique Guide. Occipito-Cervical Fusion System. Implants and instruments designed to optimize fixation to the occiput.

OPERATIVE TECHNIQUE COVER IMAGE OPTIONAL (DETAIL) IMAGE FIREBIRD NXG. spinal fixation system

MTP Set SURGICAL TECHNIQUE

Occipito-Cervical Fusion System. Implants and instruments designed to optimize fixation to the occiput.

Cervical Solutions. Lineum OCT. Spine System. Surgical Technique Guide

6.5 mm and 7.3 mm Cannulated Screws Technique Guide

POLYAXIAL SPINE SYSTEM

Thoracolumbar Solutions. Polaris. Deformity System. Trivium. Derotation System. Surgical Technique Guide

A M E D S MART SOLUTIONS FAMILY MEMBER

Occipito-Cervical Fusion System

Vectra, Vectra-T and Vectra-One. Anterior cervical plating for spinal fusion.

OPERATIVE TECHNIQUE CENTURION POSTERIOR OCCIPITAL CERVICO-THORACIC (POCT) SYSTEM

Reflex TM Surgical Technique. Anterior Cervical Plate

ACCS Anterior Cervical Compression System TECHNIQUE GUIDE

REXIOUS SPINAL SYSTEM

Interlagos Retractor System Surgical Technique

VECTRA SURGICAL TECHNIQUE. Anterior cervical plate system. This publication is not intended for distribution in the USA.

VLP FOOT Variable Angle Locked Plating System

ISO Plate SURGICAL TECHNIQUE

OCCIPITO-CERVICAL FUSION SYSTEM Implants and instruments designed to optimize fixation to the occiput

Instructions for Use. LCP Locking Compression Plate. Combine without Compromise.

Small Plate and Screw System SURGICAL TECHNIQUE

VECTRA. SURGICAL TECHNIQUE. Anterior cervical plate system. This publication is not intended for distribution in the USA.

Technique Guide. 7.0 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

ORTHOLINK. 2 - Hole Wedge Osteotomy Plate SURGICAL TECHNIQUE

1.5 MM LCP SYSTEM. For treatment of fractures and arthrodeses of canines and felines SURGICAL TECHNIQUE

Distal Fibula Plate SURGICAL TECHNIQUE

FLEX-6300 Handle Installation Guide

LCP Pilon Plate 2.7/3.5

CSLP Variable Angle. For Use with the Cervical Spine Locking Plate System TECHNIQUE GUIDE. Self-drilling Screw. Variable Screw Angulation

TORNIER MAXLOCK EXTREME. Clavicle Plating System SURGICAL TECHNIQUE

RTI TECHNOLOGIES, INC.

Fibula Plating System

Instruments for Removing DePuy Synthes Screws. Screw Removal Set

OPERATIVE TECHNIQUE RIVAL REDUCE FRACTURE PLATING SYSTEM. foot & ankle trauma procedures

Virage OCT Spinal Fixation System

SYnaPSe oct SYSteM. An enhanced set of instruments and implants for posterior stabilization of the upper spine

Maintenance Information

Surgical Technique 1

Lineum OCT Spine System

Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5. Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine

Part of the DePuy Synthes Cannulated Screw System. 3.5 mm Cannulated Screws

Technique Guide. Synapse System. An enhanced set of instruments and implants for posterior stabilization of the cervical and upper thoracic spine.

3.5 mm Cannulated Screw Technique Guide

OPERATIVE TECHNIQUE RIVAL VIEW PLATING SYSTEM. foot & ankle reconstruction procedures

INSTALLATION INSTRUCTIONS

D. Greg Anderson, MD Thomas Jefferson University Hospital Philadelphia, PA

Technique Guide. 4.5 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

MaxTorque. surgical technique. Cannulated Screw System. Foot & Ankle. OrthoHelix Technology

TRULY POLYAXIAL, SOLID AND POWERFUL

Surgical Technique. Anterior Cervical Plating System

Technique Guide. 2.4/2.7 mm Locking Tarsal Plates. Talus Plate, Navicular Plate and Cuboid Plate.

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

SpeedTip Self-Drilling Screws 1.5 / 2.0

Aviator Anterior Cervical Plating System Surgical Technique

MODEL SK61732 COMPRESSOR SERVICE KIT

Lag Screw Device TECHNIQUE GUIDE. Indicated for symphyseal fracture fixation of the mandible. Instruments and implants approved by the AO Foundation

VBOSS. Surgical Technique. Vertebral Body Support System

Integra. Capture Screw System SURGICAL TECHNIQUE

7.0 mm Cannulated Screws

VBOSS Surgical Technique

Lateral Mass Fixation Surgical Technique. and Product Catalog. Distribution For EU Only

Patent pending. Product Manual

Synapse System. An enhanced set of instruments and implants for posterior stabilization of the upper spine.

For Minimally Invasive Application of Cerclage Wires. Cerclage Passer. Surgical Technique

2.4 mm and 3.0 mm Headless Compression Screws

Assembly Instructions 10 X 10 Aluminum Frame Building

4.0 CANNULATED SCREW SYSTEM

Technique Guide. LCP Pilon Plate 2.7/3.5

MTP Fusion Surgical Technique

POLYAXIAL SPINE SYSTEM SURGICAL TECHNIQUE

Cannulated Screws Ø 3.5 mm / 4.5 mm

HCS 2.4/3.0. The countersinkable compression screw.

OsteoBridge IKA Intramedullary Knee Arthrodesis Fixation System. From the «BioBall Company» OsteoBridge Family

Technique Guide. Synapse System. An enhanced set of implants and instruments for posterior stabilization of the cervical and upper thoracic spine.

WRIST SYSTEM. ARIX Volar Distal Radius Locking Plate System

Ascent. Posterior Occipital Cervico-Thoracic (POCT) System

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

NISSAN NV200 CHEVY CITY EXPRESS WALL LINER KIT INSTALLATION INSTRUCTIONS

FENDER FLARE INSTALLATION

Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and fractures of the foot.

DISTAL RADIUS PLATES 3.5 mm / ANGULARLY STABLE. Distal radius plates 3,5 mm / angularly stable. Locking bone screws. Cortical bone screw

MEDIALMAX System SURGICAL TECHNIQUE

Axis Mounting System Instructions

Transcription:

CD HORIZON REDUCTION MULTI AXIAL SCREW Spinal System Technical Guide

T E C H N I C A L G U I D E CD HORIZON REDUCTION MULTI AXIAL SCREW Spinal System The following describes reduction of a spondylolisthesis at L5-S1 using CD HORIZON Reduction Multi Axial Screws. Step 1 CONSTRUCT ASSEMBLY With the pedicles prepared, insert standard multi axial screws at L4 and S1, and reduction multi axial screws at L5 (Figure 1). Reduction screws may be used at all levels to facilitate seating the rod. Position the rod ensuring that the desired final lordosis or contour has been created in the rod bend. The rod should sit fully in the saddle of the L4 and S1 screws, while remaining high in the saddle of the L5 screws. Insert the set screws in the L4 and S1 implants and provisionally tighten them to secure the rod using the appropriate set screw driver (Figure 2). Figure 1 Figure 2 Provisional Driver TORX 25 Shaft Reduction Multi Axial Screw Driver Ring Counter Torque Rod Reducer Sleeve Available in 7 and 14mm Rod Reducer Extended Rocker Reduction Screw Tab Breaker

Step 2 SPONDYLOLISTHESIS REDUCTION Method 1: Reduce with Set Screw Insert the reduction set screw into the reduction implant head, place the ring counter torque over the implant head and maintain throughout the reduction procedure. Advance the set screw in the bone screw. This will pull the implant to the rod, translating the vertebral body of L5 posteriorly and, therefore, reducing the Figure 3 spondylolisthesis (Figure 3). Method 2: Reduce with Extended Rocker The extended rocker can be used to seat the rod and provide incremental reduction. Grasp the extended head of the implant and rock down applying pressure to the rod (Figure 4). Figure 4 Method 3: Reduce with Rod Reducer The rod reducer can also be used in conjunction with the rod reducer sleeves to reduce the rod into the extended head. The 7 and 14mm rod reducer sleeves provide the ability to incrementally reduce the rod into the implant (Figures 5a and 5b). Figure 5a When the rod is fully seated in the bottom of the implant head, the reduction is complete. Bilateral reduction may be attained by simultaneously driving the set screws at L5 on both sides. Figure 5b

T E C H N I C A L G U I D E CD HORIZON REDUCTION MULTI AXIAL SCREW Spinal System Step 3 FINAL TIGHTENING Once the rod is completely reduced and all the set screws fully advanced and provisionally tightened, the set screws in the standard multi axial screws at L4 and S1 may be broken off. To break off the extended portion of the reduction multi axial screws, slide the tab breaker over each extended tab of the implant head and apply pressure to the tab breaker away from the rod. Figure 6a Figure 6b Figure 6c The ring counter-torque should be maintained over the implant head during this step. After this is completed, the reduction set screw may be broken off using the final set screw driver with the standard counter torque in place. If the soft tissue prevents the lateral tab from being broken off laterally, first break off the medial tab medially (Figure 6a), then break off the set screw using the ring counter torque (Figure 6b), then break off the lateral tab medially (Figure 6c). Final Construct If the tabs do not bend and break off easily, ensure that the set screw is fully advanced. If the set screw is not fully advanced, its threads will offer resistance and prevent the tabs from being broken off.

T E C H N I C A L G U I D E CD HORIZON REDUCTION MULTI AXIAL SCREW Spinal System PRODUCT ORDERING INFORMATION REDUCTION MULTI AXIAL SCREW IMPLANTS & SET SCREWS M10 SS M10 Ti M8 SS M8 Ti DESCRIPTION 9682530 9692530 8682530 8692530 5.5mm x 30mm 9682535 9692535 8682535 8692535 5.5mm x 35mm 9682540 9692540 8682540 8692540 5.5mm x 40mm 9682545 9692545 8682545 8692545 5.5mm x 45mm 9682550 9692550 8682550 8692550 5.5mm x 50mm 9682630 9692630 8682630 8692630 6.5mm x 30mm 9682635 9692635 8682635 8692635 6.5mm x 35mm 9682640 9692640 8682640 8692640 6.5mm x 40mm 9682645 9692645 8682645 8692645 6.5mm x 45mm 9682650 9692650 8682650 8692650 6.5mm x 50mm 9682655 9692655 8682655 8692655 6.5mm x 55mm 9682730 9692730 8682730 8692730 7.5mm x 30mm 9682735 9692735 8682735 8692735 7.5mm x 35mm 9682740 9692740 8682740 8692740 7.5mm x 40mm 9682745 9692745 8682745 8692745 7.5mm x 45mm 9682750 9692750 8682750 8692750 7.5mm x 50mm 9682755 9692755 8682755 8692755 7.5mm x 55mm 9680853 9690853 8680853 8690853 Reduction Set Screw INSTRUMENTS M10 SS M10 Ti M8 SS M8 Ti DESCRIPTION 9682050 9682050 8682050 8682050 Reduction Multi Axial Screw Driver 815-518 815-518 TORX 25 Set Screw Driver (M8) 84687E 84687E Provisional Set Screw Driver (M10) 9682048 9682048 8682048 8682048 Tab Breaker 9682049 9682049 8682049 8682049 Ring Counter Torque 8150500 8150500 8150500 8150500 Extended Rocker 9680957 9680957 858-957 858-957 Rod Reducer 9682907 9682907 8682907 8682907 7mm Rod Reducer Sleeve 9682914 9682914 8682914 8682914 14mm Rod Reducer Sleeve CASES & TRAYS M10 SS M10 Ti M8 SS M8 Ti DESCRIPTION 185-064 185-064 185-064 185-064 Outer Base Lid 9682001 9692001 8682001 8692001 Outer Base 8682002 8692002 8682002 8692002 Instrument Tray 9682006 9692006 8682006 8692006 Implant Base 9682007 9692007 8682008 8692008 Implant Base Lid 9682003 9692003 8682003 8692003 5.5mm Screw Module 9682004 9692004 8682004 8692004 6.5/7.5mm Screw Module 9682005 9692005 8682005 8692005 Set Screw Module

For product availability, and/or more information on any MEDTRONIC SOFAMOR DANEK USA, INC. products, contact your MEDTRONIC SOFAMOR DANEK USA, INC. Sales Associate, or call MEDTRONIC SOFAMOR DANEK USA, INC. Customer Service toll free: 800-933-2635. MEDTRONIC SOFAMOR DANEK USA, INC. 1800 Pyramid Place Memphis, TN 38132 (901) 396-3133 (800) 876-3133 Customer Service: (800) 933-2635 www.sofamordanek.com See package insert for labeling limitations. 2002 MEDTRONIC SOFAMOR DANEK USA, INC. All Rights Reserved. LITRMASST02