Reinforcing Mesh Product Guide

Similar documents
Reinforcing Mesh Product Guide

Introduction of British Standard BS 8666:2005

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

JIS G3465 Seamless Steel Tubes for Drilling

THE WORLD LEADER. Reinforcing Bar Coupler System. For The Construction Industry.

Oil tempered SiCrV-alloyed high tensile valve spring wire Only manudactured in China

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

Securifor Polyester Coated Welded Mesh Panels

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

ARMTEC.COM. Built to last. Custom Precast Solutions For Your Home. Custom Steps Custom Decks Window Wells Stairwells Brackets

TECH FACTS METRIC WELDED WIRE REINFORCEMENT FOR CONCRETE PIPE. Principles of Reinforcement

Premium-6 Hexagonal Wire Netting for general and rural applications

PD 3 Dowel Cradle. Load Transfer System Industrial Slab on Ground

AS Australian Standard STEEL WIRE FOR TENDONS IN PRESTRESSED CONCRETE. This is a free 5 page sample. Access the full version online.

BUILDING STRENGTH REBAR SPLICING HANDBOOK CONCRETE CONSTRUCTION PRODUCTS

FRANK. Technologies for the construction industry. Egcodubel Shear force dowel for low and middle loads

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

Diamond Dowel. Load Transfer System INDUSTRIAL SLAB ON GROUND

ARMTEC.COM. Built to last. Custom Precast Solutions For Your Home. Custom Steps Custom Decks Standard Steps Window Wells Brackets Stairwells

Steeline X-SPAN purlins

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

Erstantie 2, FIN Villähde Tel , Fax

East African Roofing Systems Ltd.

CONCRETE ACCESSORIES BAR-LOCK REBAR COUPLER SYSTEM

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

Scheduling, dimensioning, bending and cutting of steel reinforcement for concrete Specification

Proposed changes on NZS 3404 specified part-turn method of tensioning high strength friction grip (HSFG) property class 8.8 bolts

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2

STRUCTURAL BRACKETS CATALOGUE

TECHNICAL SPECIFICATION FOR G.I. WIRE AND G.I. STAY WIRE

Index Terms: Lathe waste concrete; Shear and bending; Shear strength; Stirrups; Simply supported beams.

ERECTION & CONSTRUCTION

FORTRESS BOTTOM PLATE ANCHORS. Product. Scope. Building Regulations. Appraisal No. 687 [2017]

Renold Roller Chain. The consistent performance of Renold roller chain is ensured by a programme of continuous testing and quality audits.

P r o d u c t D e s c r i p t i o n

Shear force transmission in expansion joints

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

When you need a clearspan of up to 6 metres of longrun steel you need...

SHED PACK Step 1: Choose your shed type.

2.3 SPECIFIC DESIGN DHS PURLINS

(1) Brass, an alloy of copper and zinc, consists of 70% by volume of copper and 30% by volume of zinc.

Table 3 - Standard shapes, their method of measurement and calculation of length Method of. Total length of bar (L) of bending dimensions

STRUCTURAL BRACKETS CATALOGUE

Hyper ArmourMate. Joint Edge Protection INDUSTRIAL SLAB ON GROUND

WHY YOU SHOULD USE TUFFLOOR. components

Oil tempered SiCrV-alloyed high tensile valve spring wire

Bolt Material Types and Grades 1- Bolts made of carbon steel and alloy steel: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 10.9 Nuts made of carbon steel and alloy

Section 914. JOINT AND WATERPROOFING MATERIALS

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

isd dunaferr Product catalogue

Convex Strainers DN PN 80, 100, 200

PEC-TA Cast-in Channels and Bolts. Certified German quality for high-end fixing solutions. Advantages of using PEC Cast-in Channels.

TECHNICAL MANUAL. HPM Rebar Anchor Bolt Easy and Fast Bolted Connections

Double Bar Plate Dowels for Saw-Cut Contraction Joints

REBAR SPLICING HANDBOOK PERFORM WITH PRECISION CONCRETE CONSTRUCTION PRODUCTS

DRAFT UGANDA STANDARD

² TL Beton-StB 07 = German technical conditions for construction materials for concrete road pavements

Extract 8.7 When dimensioning an acute angle the tangential lines shown in Figure 4 shall be used. (C) Figure 4 - Dimensioning of an acute angle

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

EXPERIMENTAL AND ANALYTICAL STUDIES ON THE STRENGTHENING OF RC FRAMES

CHAPTER 10 MICHIGAN DESIGN MANUAL BRIDGE DESIGN (SI) SHOP DRAWING REVIEW TYPES OF SHOP DRAWINGS Structural Steel

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in two years.

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

WELDA FASTENING PLATES

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

CARES Technical Approval Report TA1-B 5042

Test Report Security Window Grille. Test Report Number: /3 PAM Number: 3930

FRANK. Technologies for the construction industry. Egcodorn Shear force dowel for expansion joints

TECHNICAL INSTRUCTIONS: FOUNDRY. Page 1 of 8

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

STRUCTURAL ATTACHMENTS

How-To-build guide carport

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

1 SLABBING, RENDERING, FLOATING AND SKIMMING

Standard Specification for High-Strength Steel Bolts, Classes 10.9 and , for Structural Steel Joints [Metric] 1

CLT Cross Laminated Timber

CORRIGENDA TO STEEL CONNECTIONS SERIES 1 AND 2 Version 2

ISO INTERNATIONAL STANDARD. Welding Studs and ceramic ferrules for arc stud welding

Materials. Density, Hooke's law, Young modulus. 174 minutes. 174 marks. Page 1 of 29

Cooke Precast Concrete

Requirements for manufacture of anchors

SHED PACK. Sheds are commonly constructed using portal frames.

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

STEEL PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/

Australian Standard. Precast reinforced concrete box culverts. Part 1: Small culverts (not exceeding 1200 mm width and 900 mm depth) AS 1597.

CWM. Agricultural, Commercial, Industrial Product Brochure.

Suitable for panels up to 12 tonne. No sharp edges. Lighter than comparable capacity systems. So, why the need for change?

Chemical composition. Type 2 as per F568: C ( ); P (max 0.048); S (max 0.058); Mn (min 0.74); B (min );

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

ASLAN 600 GLASS FIBER REINFORCED POLYMER (GFRP) DOWEL BARS FOR LOAD TRANSFER IN CONCRETE SLABS

DRAFT MALAYSIAN STANDARD. Bead wire - Specification. OFFICER/SUPPORT STAFF: (LHL/ija) Descriptors: bead wire, tyres, specification

FURTHER STATIC TENSION TESTS OF BOLTED JOINTS. A B S T RAe T

TOPSPAN 22 / 40 LYSAGHT TOPSPAN 22 / 40. Steel roof and ceiling battens for non cyclonic applications

Contents DIN 50125:

Plate 60 ArmourMate. Joint Edge Protection INDUSTRIAL SLAB ON GROUND. Plate 60 AmourMate. Joint Edge Protection

Transcription:

Reinforcing Mesh Product Guide Reinforcing New Zealand since 1954 Super Ductile 500E & Hard Drawn SOUTH ISLAND

Fletcher Reinforcing supplies the reinforcing steel and mesh that provides the strength to New Zealand s buildings and infrastructure. Mesh is available from national Building Merchants or our branch network to construction sites and builders throughout New Zealand. Fletcher Reinforcing offer a range of New Zealand manufactured mesh. The range covers both Super Ductile mesh in grade 500E wire and a proven range of hard drawn mesh in the sizes required by builders and contractors throughout New Zealand. The Department of Building & Housing now states the reinforcing requirements for concrete slabs-on-ground of buildings built in accordance with NZS 3604: 2011, have a minimum of 2.27 kg/m2 of Grade 500E reinforcing mesh fabric which conforms with AS/NZS4671:2001. Grade 500E (seismic) as per AS/NZS 4671:2001 ield stress (MPa) >500 <600 Elongation >10% Tensile Ratio % >1.15 <1.40 Weight per m2 complies with NZS 3604:2011 (min 2.27kg/m2) Weld Shear Strength >5.9 kn Hard drawn mesh: Fletcher Reinforcing offers a range of mesh sheet sizes and centres to meet the needs of typical New Zealand applications. Our range covers standard sheet sizes of 4.65m x 1.97m through to our larger economical sheets which are 6.15m x 2.42m. Centres are either 150 x150mm or the step through option of 300 x 300mm.

New Zealand Standards Standards New Zealand controls the preparation and publishing of all Standard Specifications and Codes of Practice in New Zealand. They are developed by expert committees using a consensus-based process that facilitates public input. The relevant Standards listed below, specify the mechanical properties of the steel wire used for concrete reinforcement, the fabrication of the welded fabric and the methods of application in respect to concrete reinforcement. Visit www.standards.co.nz for more information. AS/NZS4671:2001 Specification for Welded Fabric of Drawn Steel Wire for Concrete Reinforcement The pitch (a) of longitudinal bars and transverse bars shall not be less than 50 mm. The pitch shall be measured as shown below. The tolerance of the pitch shall not be more than +/-0.075 times the specified value. NZS3101:2006 Code of Practice for The Design of Concrete Structures This Standard lays out the development length and lap-splice requirements for plain wire mesh and deformed wire mesh, and is the basis of any pertinent calculations or recommendations given in this Product Guide.

Hard Drawn Mesh Equivalents Standard Equivalent Centres Wire Ø Width Nett (m 2 ) Fletcher Reinforcing Item 668 150 4.0 4650 1970 7.525 668L 665 150 5.3 4650 1970 7.525 665L 663 150 6.3 4650 1970 7.525 663L 662 150 7.1 661 150 7.5 Equivalents are based on the nominal sectional area of steel per metre width *Note: Additional meshes are available as a special order. Minimum order quantities will apply. Please contact your local Fletcher Reinforcing Branch for further details Super Ductile 500E Mesh Equivalents Equivalent Centres Wire Ø Width Nett Cover (m 2 ) Fletcher Reinforcing Item 665 200 6.1 5050 2050 8.64 SE62Res 665 200 6.1 5050 2020 8.6 SE62 664 300 7.0 6400 2370 13.6 SE72 662 300 8.0 6400 2370 13.6 SE82 661 200 9.0 6410 2380 13.6 SE92 What does SE62 mean? AS/NZS 4671:2001 designates letters to be used to identify welded mesh products: S = Square (shape of grid centres) E = Seismic grade (Earthquake) 6 = 6mm wire 2 = 200mm centres Equivalents are based on the nominal sectional area of steel per metre width

Description Hard drawn wire mesh 485 Mpa Wire Diameter Centres Cross Section (mm 2 /m) Mass per m 2 (kg/m 2 ) Industry Equivalents 668L 4.0 150 83.8 1.315 668 Description Super Ductile wire mesh Min: 500 MPa Max: 600MPa Wire Diameter Centres (m 2 ) Cross Section (mm 2 /m) Mass per m 2 (kg/m 2 ) 665L 5.3 150 147.1 2.309 665 SE62Res 6.1 200 146.1 2.294 665 SE62 6.1 200 146.1 2.294 665 SE73DE 7.5 300 147.3 2.312 664 663L 6.3 150 207.8 3.263 663 663 662 661 Equivalents are based on the nominal sectional area of steel per metre width *Note: Additional meshes are available as a special order. Minimum order quantities will apply. Please contact your local Fletcher Reinforcing Branch for further details

Seismic Grade Reinforcing Mesh Product Description: 5.05m x 2.02m 200 x 200 Grid R6.1 Line Wire, R6.1 Cross Wire SE62 Res SI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 6.1 R 200 5050 11 25 25 146.1 0.2294 12.77 Cross Wire 6.1 R 200 2020 26 10 10 146.1 0.2294 12.07 GROSS SHEET WEIGHT (Kg): 24.84 MASS PER SQ METER (Kg/m 2 ): 2.294 GROSS SHEET AREA (m 2 ) 10.201 NETT COVER (m 2 ) 8.64 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 25 ESTIMATED CUBIC (m 3 ) 0.0933 BUNDLE WEIGHT (Tonnes): 0.6211 Elongation % ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 7.3 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001

Seismic Grade Reinforcing Mesh Product Description: 6.05m x 2.42m 200 x 200 Grid R6.1 Line Wire, R6.1 Cross Wire SE62 SI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 6.1 R 200 6050 13 25 25 146.1 0.2294 18.08 Cross Wire 6.1 R 200 2420 31 10 10 146.1 0.2294 17.25 GROSS SHEET WEIGHT (Kg): 35.33 MASS PER SQ METER (Kg/m 2 ): 2.294 GROSS SHEET AREA (m 2 ) 14.641 NETT COVER (m 2 ) 12.76 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 2.3221 BUNDLE WEIGHT (Tonnes): 0.8833 Elongation % ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 7.3 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001

Seismic Grade Reinforcing Mesh Product Description: 6.425m x 2.37m 200 x 200 Grid R7.0 Line Wire, R7.0 Cross Wire SE72DE SI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 1 7.0 R 200 6425 10 37 37 192.4 0.3021 19.44 Longitudinal Wire 2 5.50 R 75 6425 4 37 37 0.1865 4.81 Cross Wire 7.0 R 200 2370 34 10 10 192.4 0.3021 24.38 GROSS SHEET WEIGHT (Kg): 48.63 MASS PER SQ METER (Kg/m 2 ): 3.021 GROSS SHEET AREA (m 2 ) 15.227 NETT COVER (m 2 ) 13.642 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 0.1599 BUNDLE WEIGHT (Tonnes): 1.2158 Elongation % ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 9.6 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001

Seismic Grade Reinforcing Mesh Product Description: 5.025m x 2.27m 300 x 300 Grid R7.5 Line Wire, R7.5 Cross Wire SE73DE SI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 1 7.05 R 300 5000 6 37 37 147.3 0.3468 10.47 Longitudinal Wire 2 5.50 R 75 5000 4 37 37 0.1865 3.76 Cross Wire 7.05 R 300 2270 19 10 10 147.3 0.3468 14.98 GROSS SHEET WEIGHT (Kg): 29.21 MASS PER SQ METER (Kg/m 2 ): 2.312 GROSS SHEET AREA (m 2 ) 11.407 NETT COVER (m 2 ) 10.082 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 0.1283 BUNDLE WEIGHT (Tonnes): 0.7302 Elongation % ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 9.6 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001

Seismic Grade Reinforcing Mesh Product Description: 6.425m x 2.37m 200 x 200 Grid R8.0 Line Wire, R8.0 Cross Wire SE82DE SI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 1 8.0 R 200 6425 10 37 37 251.3 0.3946 25.38 Longitudinal Wire 2 5.5 R 75 6425 4 37 37 0.1865 4.81 Cross Wire 8.0 R 200 2370 34 10 10 251.3 0.3946 31.84 GROSS SHEET WEIGHT (Kg): 62.03 MASS PER SQ METER (Kg/m 2 ): 3.946 GROSS SHEET AREA (m 2 ) 15.227 NETT COVER (m 2 ) 13.642 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 0.1827 BUNDLE WEIGHT (Tonnes): 1.5507 Elongation % ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 12.5 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001

Seismic Grade Reinforcing Mesh Product Description: 6.435m x 2.38m 200 x 200 Grid R9.0 Line Wire, R9.0 Cross Wire SE92DE SI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 1 9.0 R 200 6435 10 37 37 318.1 0.4994 32.17 Longitudinal Wire 2 6.1 R 80 6435 4 37 37 0.2294 5.92 Cross Wire 9.0 R 200 2380 34 10 10 318.1 0.4994 40.45 GROSS SHEET WEIGHT (Kg): 78.54 MASS PER SQ METER (Kg/m 2 ): 4.994 GROSS SHEET AREA (m 2 ) 15.315 NETT COVER (m 2 ) 13.58 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 0.2068 BUNDLE WEIGHT (Tonnes): 1.9635 Elongation % ield Strength Tensile Ratio Weld Shear Min Max Min Max Strength 10 % 500MPa 600MPa 1.15 1.4 > 12.5 Product is fully tested for Grade 500E compliance as per AS/NZS 4671:2001

Seismic Grade Reinforcing Mesh Product Description: 4.65m x 1.97m 150 x 150 Grid D4.0 Line Wire, D4.0 Cross Wire 668L SI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 4.0 D 150 4650 14 75 75 83.8 0.0986 6.42 Cross Wire 4.0 D 150 1970 31 10 10 83.8 0.0986 6.02 GROSS SHEET WEIGHT (Kg): 12.44 MASS PER SQ METER (Kg/m 2 ): 1.315 GROSS SHEET AREA (m 2 ) 9.161 NETT COVER (m 2 ) 7.525 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 0.0550 BUNDLE WEIGHT (Tonnes): 0.3110 Wire Diam Elongation % 0.2% Proof Stress Min Max Ratio Rm / Re < 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%

Hard Drawn Reinforcing Mesh Product Description: 4.65m x 1.97m 150 x 150 Grid D5.3 Line Wire, D5.3 Cross Wire 665L SI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 5.3 D 150 4650 14 75 75 147.1 0.1732 11.28 Cross Wire 5.3 D 150 1970 31 10 10 147.1 0.1732 10.58 GROSS SHEET WEIGHT (Kg): 21.85 MASS PER SQ METER (Kg/m 2 ): 2.309 GROSS SHEET AREA (m 2 ) 9.161 NETT COVER (m 2 ) 7.525 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 0.0728 BUNDLE WEIGHT (Tonnes): 0.5463 Wire Diam Elongation % 0.2% Proof Stress Ratio Min Max Rm / Re < 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%

Hard Drawn Reinforcing Mesh Product Description: 4.65m x 1.97m 150 x 150 Grid D6.3 Line Wire, D6.3 Cross Wire 663L SI Overhangs mm 2 /m Wire kg/m Weight Longitudinal Wire 6.3 D 150 4650 14 75 75 207.8 0.2447 15.93 Cross Wire 6.3 D 150 1970 31 10 10 207.8 0.2447 14.94 GROSS SHEET WEIGHT (Kg): 30.87 MASS PER SQ METER (Kg/m 2 ): 3.263 GROSS SHEET AREA (m 2 ) 9.161 NETT COVER (m 2 ) 7.525 Ratio STACK & TURNED (/N): No. OF SHEETS / BUNDLE: 2 25 ESTIMATED CUBIC (m 3 ) 0.0866 BUNDLE WEIGHT (Tonnes): 0.7719 Wire Diam Elongation % 0.2% Proof Stress Ratio Min Max Rm / Re < 5.0mm 1.5% 485MPa 1.03% 5.0mm 1.5% 485MPa 750MPa 1.03%

Notes

Overview The Fletcher Reinforcing Smart Phone App is designed to offer you immediate access to the information you need about our ranges of Super Ductile and Hard Drawn meshes. This Guide will outline how to access this information quickly and easily. Downloading Available for both the Apple iphone and all Android phones, the free download can be accessed through the Apple App Store and the Android Market. Just search for Fletcher Reinforcing Alternatively, scan this QR Code from your phone to be taken to the appropriate download: Current Devices The App is currently available for: iphone Android phones ipad (not optimised) V05.00.0218