Product Bulletin. Belden DataTwist 4800 Cables

Similar documents
New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU

UTP Copper. SFTP Copper. FUTP Copper. Composite. Special Applications Copper. Category 5e. Category 6 Category 5E Category 3. Category 7A Category 7

NETWORK CONNECTIVITY SYSTEMS

Category 6 UTP EuroClass C ca Cables

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

AMP NETCONNECT Category 6 System

DataTwist 5 ScTP Cable

Information technology. Generic cabling systems, General requirements

Detailed Specifications & Technical Data

Four Cat 5e 24 AW G Bonded-Pairs solid bare copper conductors, polyolefin insulation, PVC jacket.

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Category 7 A /Class F A Products

n Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs.

1) The addition of TCL and ELTCTL requirements to Category 6

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

DELTA Test Report. Certification testing of generic cabling products: Unscreened channel, Class E, 4 connector model. Performed for Sterling

Call For Interest PoE- plus. Chris Di Minico MC Communications

Category 6 A F/FTP Euroclass C ca Cables

Detailed Specifications & Technical Data

Install & Go Cat.8 STP Trunk Cable Assembly Description

SECTION BUILDING WIRE AND CABLE

COPPER + LWL RAW CABLES

WIRE&CABLE FILS&CÂBLES S I N C E

Detailed Specifications & Technical Data

Submittal Approval Form

CAT 5e UTP Cable: NETSET BOX [305m], indoor

Composite Data, Audio, Video, Security and Control Cables Banana Peel Jacketless Cables Category 5e

Detailed Specifications & Technical Data

Nexans Industrial Solutions PRODUCT CATALOG

Industrial Data Solutions Industrial Ethernet Cables Category 5e DataTuff Twisted Pair Cables Heavy Duty Sunlight- and Oil-Resistant Jackets

Microwave Coax. w w w. t e m p f l e x. c o m ( ) M i l f o r d R d. S o u t h G r a f t o n, M A

Detailed Specifications & Technical Data

DataTuff Industrial Ethernet Solutions

TSB-67. Transmission Performance Specifications for Field Testing of UTP Cabling Systems

Crestron Wire Product Guide

Cable Solutions FOR THE INDUSTRIAL AUTOMATION MARKET

UTP Cat 5e cable (200 MHz) (PVC sheath)

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Microwave Coax Cable

CABLE.

Detailed Specifications & Technical Data


EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2


Data sheet E-DAT Industry RJ45 plug black Cat.6 Class E A

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)

Workstation Outlets GigaFlex PS6+ Modules Category 6

Contents. Category7 SSTP Solid Indoor Cable - Page 03

Data sheet Patch cord Cat.6 A AWG m yellow

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

Data sheet C6 A modul K 180 jack - Keystone style

Analog Multi-Pair Snake Cable

Data sheet C6 A modul K 90 jack - keystone style

UNIRAIL D RS485 and BUS cables

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

COAX 101. Author: Rob Wessels. Vice President of Engineering

Dielectric Material. Cable Type

MHR-2 Two Conductor Mini High Resolution S-Video Cable

Test Report based on DIN EN ISO/IEC 17025:2005

Amphenol Cable. Features Allows for mass termination Up to 64 conductors

WHITE PAPER INTRODUCTION DC RESISTANCE UNBALANCE TESTING: EASY, LOW-COST INSURANCE FOR YOUR POE SYSTEMS

A Few (Technical) Things You Need To Know About Using Ethernet Cable for Portable Audio

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

ECE 528 Understanding Power Quality

Individually Shielded Cable Characteristics

LTE high-performance coaxial cables (RG replacement)

Modular Plug Connectors Compliant to Enhanced Category 5 Standards

Cable Analysis. Extracting Information from Measured Data. The Performance Leader in Hand-Held Network Tools. Fanny Mlinarsky.

DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/75-RG214 AND M17/75-RG365

Cable Testing TELECOMMUNICATIONS AND NETWORKING

Media. Twisted pair db/km at 1MHz 2 km. Coaxial cable 7 db/km at 10 MHz 1 9 km. Optical fibre 0.2 db/km 100 km

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860)

Chapter 12: Transmission Lines. EET-223: RF Communication Circuits Walter Lara

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860)

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568B. Illustrations P/N I-B1 EAN Product specification. Page 1/

Data sheet C6 A RJ45 field plug pro 360

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Microphone and Musical Instrument Cable Overview

Superiorr Essex. Suite 150

Standard Lengths of. Code Ft. m

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet C6 A RJ45 field plug pro

Cross-Connect and Distribution Frame Wire 5

High Speed Interconnects

ADVANCED FLAT CABLE SOLUTIONS

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

Understanding and Inspecting THE DIGITAL BUS. by Jim Sparks

AVA5-50FX. Product Classification. Standards And Qualifications. Construction Materials. Dimensions. Electrical Specifications

FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

Audio Design Audio Systems

CAT 6 Data Wiring System Connectors

Copper and Fiber Optic Cables

This is a preview - click here to buy the full publication

Transcription:

Product Bulletin PB 296 Belden DataTwist 4800 Cables DataTwist 4800 UTP Cables provide significant headroom and robust data transmission performance for today s most demanding applications. The cables support the industry s most powerful Category 6 networking solution: Belden IBDN System 4800. Belden s DataTwist 4800 Cables Exceed TIA/EIA Requirements and Offer Significant Headroom Over Category 6 DataTwist 4800 Cable If your business is looking to the future, and investing in best-in-class technologies is part of your IT strategy, you need the performance and reliability delivered by DataTwist 4800 Cables. These enhanced Category 6 cables were conceived to support the most demanding multi-gigabit protocols and networking applications. DataTwist 4800 Cables consist of 4 pairs of 23 AWG insulated copper conductors, incorporating a unique central spline which separates and holds the twisted pairs of the cable firmly in position at a uniform distance from each other. This design provides improved Power Sum Crosstalk performance in comparison to conventional cables where the twisted pairs can nest into each other and change position during manufacturing or handling. The end result is very stable transmission performance that is more resilient to installation variables. Depending on your application requirements, DataTwist 4800 Cables can be specified in either Nonbonded-Pair design or in Belden s exclusive Bonded-Pair construction. All DataTwist 4800 Cables are designed to provide low Insertion Loss (low signal Attenuation). This characteristic enables increased signal power over a higher range of frequencies. This strong signal translates into maximum headroom and more robust transmission for today s applications as well as a capacity for those of tomorrow s networks. The higher signal power of DataTwist 4800 Cables also results in a higher PSACR. With this higher ratio, 4800 Cables are able to provide fewer transmission errors and higher data rate capability. Belden DataTwist 4800 Cables are part of the Belden IBDN 4800 System. The Belden 4800 System provides 300 MHz of channel bandwidth and a data rate of 4.8 Gb/s, giving you a high performance system to support today s demanding network applications as well as the evolving bandwidth hungry applications of tomorrow.

Belden DataTwist 4800 Cables Help Future-Proof the Network The Belden IBDN 4800 Solution delivers unparalleled performance with 300 MHz of channel bandwidth and a maximum data rate of 4.8 Gb/s. Applications DataTwist 4800 Cable is intended to be used for horizontal cable installations of high speed Local Area Networks (LANs) for transmission speeds up to 4.8 Gb/s. Specific applications include: 1000BASE-T Applications (IEEE 802.3ab) Power Over Ethernet Plus 2 pairs, up to 30 Watts or 4 pairs, up to 60 Watts (IEEE 802.3at) Power Over Ethernet 2 pairs, up to 12.95 Watts (IEEE 802.3af) Broadband Video (CATV) & High Speed Internet (DOCSIS) over UTP up to 860 MHz High Temperature performance up to 50 C without length de-rating for 1000BASE-T and 100BASE-TX High Noise Immunity with a Noise Reduction Factor of 0.5 (TIA 569B) VoIP Applications with stringent Bit Error Rate (BER) / Quality of Service (QoS) objectives Features & Benefits Central spline design separates pairs and maintains stable pair position, thus improving NEXT and impedance performance Stable pair position provides built-in resilience to installation stresses Improved attenuation ensures stronger signal power Maximized bandwidth and signal-to-noise margin for mission-critical applications Larger 23 AWG conductors are ideal for PoE and PoE+ applications Descending distance marking for cable length reduces waste Matching tip and ring color code for ease of installation Available in Spool-in-Box packaging for ease of installation, handling and inventory management Available in CMR, CMP and LSZH versions Available in Bonded-Pair or Nonbonded-Pair design Technical Specifications* Physical Characteristics Conductors: 23 AWG solid copper Insulation - Plenum: Bonded-Pair: 100% FEP Nonbonded-Pair: Dual Insulation FEP over a Polyolefin base - Riser and LSZH: Polyolefin Cable Core: Filler, Four twisted pairs, cabled around Belden's patented cross-web or E-spline Jacket with Rip Cord: - Plenum: LSPVC - Riser: PVC - LSZH: Low Smoke Zero Halogen Polymer Alloy - Jacket printed at intervals indicating cable code, AWG, listings (NEC Code), verification, date, manufacturing traceability code - Descending length markings start at highest number and end at 0 Mechanical Characteristics Minimum Recommended Installation Temperature: 5 C (40 F) Temperature Rating: 75 C (167 F) Transmission Characteristics Values up to 600 MHz are minimum guaranteed values (400 MHz for Nonbonded- Pair) Values above 600 MHz are for engineering purposes only (400 MHz for Nonbonded-Pair) DC Resistance @ 20 C: - Bonded-Pair: 8.2 ohms/100 m - Nonbonded-Pair: 6.6 ohms/100 m DC Resistance Unbalance, max.: 3% Mutual Capacitance, nom.: 5.1 nf/100 m Capacitance Unbalance Pair to Ground, max.: 66pF/100 m 2

Input Impedance: Input Impedance Bonded-Pair Nonbonded-Pair 100±12 1-20 MHz 100±15 20-250 MHz 1-200 MHz 100±20 250-350 MHz 100±22 350-600 MHz 200-400 MHz Nominal Velocity of Propagation (NVP): - Plenum: 70% @ 10 MHz - Riser: 68% @ 10 MHz Propagation Delay (Skew): 30 ns/100 m Qualifications Category 6 requirements per TIA/EIA-568-B.2-1, ISO/IEC 11801 ed 2.1 (2008) Class E resistance unbalance results in the cabling infrastructure being less susceptible to electromagnetic and radio frequency interference (EMI/RFI) in noisy environments. Belden s ultra-robust Bonded-Pair cables can provide additional peace of mind, especially when deployed in: Mission-critical data centers Frequently changing networking environments where constant moves, adds and changes are routine Environments where electromagnetic and radio frequency interference (EMI/RFI) create noise and signal transmission problems High frequency applications in which return loss can affect signal integrity Nonbonded-pair Bonded-Pair Riser: ITS/ETL Certified as CMR, and listed as NEC Type CMR per UL Standard 444 Plenum: ITS/ETL Certified as CMP, and listed as NEC Type CMP per UL Standard 444 LSZH: ISO/IEC 332-1, 754-2 and 1034-2 * Values are the same for Bonded-Pair and Nonbonded-Pair Cables, unless specifically noted. Select Bonded-Pair or Nonbonded-Pair Construction In stable networking environments, Belden s standard DataTwist 4800 Cables will perform reliably to exceed TIA/EIA Category 6 standards. When the application calls for a more robust solution, Belden Bonded-Pair DataTwist 4800 Cables will provide superior integrity and electrical performance from the reel to real life through all the stresses of installation and post-installation maintenance. Belden calls this unique capability Installable Performance. Installed and manipulated nonbonded-pairs (left) have a tendency to gap, varying the centricity of the two conductors. Belden Bonded-Pairs (right) do not gap so the physical integrity of the pair is maintained. Visit www.belden.com to learn more about Belden s Bonded-Pair construction and its unique benefits. Belden provides the option of ordering DataTwist 4800 Cables in either Bonded-Pair or in Nonbonded-Pair constructions. The choice will depend on the type of signals supported, the critical nature of the information transmitted, and the stability of the networking environment. Belden s Bonded-Pair Cables feature a patented design in which the individual conductors are securely bonded along their longitudinal axis to guarantee uniform spacing within each twisted pair a key factor in maintaining consistently high electrical performance. Because Belden s Bonded-Pair Cables have better centricity and symmetry, they provide improved return loss and balance performance. Superior transverse conversion loss (TCL), capacitance unbalance and Key Physical Attributes DataTwist 4800 Bonded-Pair Cable 4-pair, 23 AWG Bonded-Pair Nominal O.D. Min. Bend Radius Weight (Cable Only) CMR (7851A) 5.766 x 8.001 mm 6.35 mm 46.47 kg/km (0.227 x 0.315 in.) (0.25 in.) (31.3 lb/kft) CMP (7852A) 5.537 x 7.366 mm 6.35 mm 50.18 kg/km (0.218 x 0.290 in.) (0.25 in.) (33.8 lb/kft) LSZH (7851NH) 6.121 x 8.357 mm 6.35 mm 46.47 kg/km (0.241 x 0.329 in.) (0.25 in.) (31.3 lb/kft) Key Physical Attributes DataTwist 4800 Nonbonded-Pair Cable 4-pair, 23 AWG Nonbonded-Pair Nominal O.D. Min. Bend Radius Weight (Cable Only) CMR (4812) 6.22 mm 24.88 mm 50.47 kg/km (0.245 in.) (0.98 in.) (34.0 lb/kft) CMP (4813) 6.09 mm 23.37 mm 54.93 kg/km (0.240 in.) (0.92 in.) (37.0 lb/kft) 4824 LSZH version available upon request 3

Technical Specifications (continued) Key Electrical Attributes DataTwist 4800 Bonded-Pair Cable Frequency (MHz) Max. Insertion Loss (db/100 m) Min. PSNEXT (db) Min. PSACR (db) Min. PSACRF (db) Min. Return Loss (db)* THE BONDED-PAIR ADVANTAGE Min. Balance TCL (db)* Min. Balance ELTCTL (db)* TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden 1 2.0 1.9 72.3 80.3 70.3 78.5 64.8 70.8 20.0 20.0 40.0 45.0 35.0 40.0 4 3.8 3.6 63.3 71.3 59.5 67.7 52.8 58.8 23.0 23.0 40.0 45.0 23.0 28.0 8 5.3 5.1 58.8 66.8 53.5 61.7 46.7 52.7 24.5 24.5 40.0 45.0 16.9 21.9 10 6.0 5.7 57.3 65.3 51.3 59.6 44.8 50.8 25.0 25.0 40.0 45.0 15.0 20.0 16 7.6 7.2 54.2 62.3 46.6 55.0 40.7 46.7 25.0 25.0 38.0 43.0 10.9 15.9 20 8.5 8.1 52.8 60.8 44.3 52.7 38.8 44.8 25.0 25.0 37.0 42.0 9.0 14.0 25 9.5 9.1 51.3 59.3 41.8 50.3 36.8 42.8 24.3 25.0 36.0 41.0 7.0 12.0 31.25 10.7 10.2 49.9 57.9 39.2 47.7 34.9 40.9 23.6 25.0 35.1 40.1 - - 62.5 15.4 14.7 45.4 53.4 30.0 38.7 28.9 34.9 21.5 25.0 32.0 37.0 - - 100 19.8 18.9 42.3 50.3 22.5 31.4 24.8 30.8 20.1 25.0 30.0 35.0 - - 200 29.0 27.5 37.8 45.8 8.8 18.3 18.8 24.8 18.0 21.6 27.0 32.0 - - 250 32.8 31.2 36.3 44.3 3.5 13.2 16.8 22.8 17.3 20.5 26.0 31.0 - - 300-34.5-41.2-8.6-21.3-20.1 - - - - 350-37.7-40.2-4.5-19.9-19.8 - - - - 400-40.6-39.3-0.6-18.8-19.5 - - - - 450-43.5-38.5-0.0-17.7-18.9 - - - - 500-46.2-37.8 - - - 16.8-18.4 - - - - 550-48.8-37.2 - - - 16.0-18.0 - - - - 600-51.4-36.6 - - - 15.2-17.6 - - - - 650-53.9-36.1 - - - 14.5-17.2 - - - - 750-58.6-35.2 - - - 13.3-16.5 - - - - 860-63.6-34.3 - - - 12.1-15.8 - - - - Values above 600 MHz for engineering purposes only. * Belden s Bonded-Pair Cables provide improved return loss and balance performance. Key Electrical Attributes DataTwist 4800 Nonbonded-Pair Cable Frequency (MHz) Max. Insertion Loss (db/100 m) Min. PSNEXT (db) Min. PSACR (db) Min. PSACRF (db) Min. Return Loss (db) Min. Balance TCL (db) Min. Balance ELTCTL (db) TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden TIA Belden 1 2.0 1.8 72.3 78.3 70.3 76.5 64.8 71.8 20.0 20.0 40.0 40.0 35.0 35.0 4 3.8 3.4 63.3 69.3 59.5 65.9 52.8 59.8 23.0 23.0 40.0 40.0 23.0 23.0 8 5.3 4.8 58.8 64.8 53.4 60.0 46.7 53.7 24.5 24.5 40.0 40.0 16.9 16.9 10 6.0 5.3 57.3 63.3 51.3 58.0 44.8 51.8 25.0 25.0 40.0 40.0 15.0 15.0 16 7.6 6.8 54.2 60.2 46.7 53.5 40.7 47.7 25.0 25.0 38.0 38.0 10.9 10.9 20 8.5 7.6 52.8 58.8 44.3 51.2 38.8 45.8 25.0 25.0 37.0 37.0 9.0 9.0 25 9.5 8.5 51.3 57.3 41.8 48.8 36.8 43.8 24.3 24.6 36.0 36.0 7.0 7.0 31.25 10.7 9.6 49.9 55.9 39.2 46.3 34.9 41.9 23.6 24.2 35.1 35.1 - - 62.5 15.4 13.8 45.4 51.4 30.0 37.6 28.9 35.9 21.5 22.9 32.0 32.0 - - 100 19.8 17.8 42.3 48.3 22.5 30.5 24.8 31.8 20.1 22.1 30.0 30.0 - - 200 29.0 26.2 37.8 43.8 8.8 17.6 18.8 25.8 18.0 20.9 27.0 27.0 - - 250 32.8 29.7 36.3 42.3 3.5 12.6 16.8 23.8 17.3 20.4 26.0 26.0 - - 300-33.0-41.1-8.2-22.3-19.6 - - - - 350-36.0-40.1-4.1-20.9-19.3 - - - - 400-39.0-39.3-0.3-19.8-19.0 - - - - 450-41.8-38.5 - - - 18.7-18.4 - - - - 500-44.5-37.8 - - - 17.8-17.9 - - - - 550-47.1-37.2 - - - 17.0-17.5 - - - - 600-49.6-36.6 - - - 16.2-17.1 - - - - 650-52.1-36.1 - - - 15.5-16.7 - - - - 750-56.8-35.2 - - - 14.3-16.0 - - - - 860-61.8-34.3 - - - 13.1-15.3 - - - - Values above 400 MHz for engineering purposes only. 4

Ordering Information DataTwist 4800 Bonded-Pair, 4-pair, 23 AWG, CMR, Category 6 DataTwist 4800 Cables are available in plenum, riser and LSZH versions. 7851A F6HA1000 Gray 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7851A 002A1000 Red 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7851A 003A1000 Orange 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7851A 004A1000 Yellow 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7851A 005A1000 Green 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7851A 006A1000 Blue 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7851A 009A1000 White 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7851A 010A1000 Black 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7851A F6H1000 Gray 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7851A 0021000 Red 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7851A 0031000 Orange 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7851A 0041000 Yellow 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7851A 0051000 Green 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7851A 0061000 Blue 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7851A 0091000 White 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7851A 0101000 Black 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) DataTwist 4800 Bonded-Pair, 4-pair, 23 AWG, CMP, Category 6 7852A 004A1000 Yellow 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7852A 005A1000 Green 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7852A D15A1000 Blue 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7852A 008A1000 Gray 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7852A 009A1000 White 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7852A 0021000 Red 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7852A 0041000 Yellow 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7852A 0051000 Green 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7852A D151000 Blue 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7852A 0081000 Gray 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7852A 0091000 White 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) 7852A 0101000 Black 305 m (1000 ft) Spool 27 spools/pallet 8235 m (27000 ft) DataTwist 4800 Bonded-Pair, 4-pair, 23 AWG, LSZH, Category 6 7851NH E4XA1000 Gray 305 m (1000 ft) Spool-in-Box 18 boxes/pallet 5490 m (18000 ft) 7851NH E4X1000 Gray 305 m (1000 ft) Spool 24 spools/pallet 7320 m (24000 ft) 5

Ordering Information (continued) DataTwist 4800 Nonbonded-Pair, 4-pair, 23 AWG, CMR, Category 6 4812 006A1000 Blue 305 m (1000 ft) Spool-in-Box 22 boxes/pallet 6710 m (22000 ft) 4812 009A1000 White 305 m (1000 ft) Spool-in-Box 22 boxes/pallet 6710 m (22000 ft) 4812 0021000 Red 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4812 0041000 Yellow 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4812 0051000 Green 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4812 0061000 Blue 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4812 0081000 Gray 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4812 0091000 White 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4812 0062500 Blue 762 m (2500 ft) Spool 15 spools/pallet 11438 m (37500 ft) DataTwist 4800 Nonbonded-Pair, 4-pair, 23 AWG, CMP, Category 6 4813 D15A1000 Blue 305 m (1000 ft) Spool-in-Box 22 boxes/pallet 6710 m (22000 ft) 4813 009A1000 White 305 m (1000 ft) Spool-in-Box 22 boxes/pallet 6710 m (22000 ft) 4813 0041000 Yellow 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4813 0051000 Green 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4813 0081000 Gray 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4813 0091000 White 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4813 0101000 Black 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4813 D151000 Blue 305 m (1000 ft) Spool 36 spools/pallet 10980 m (36000 ft) 4813 0092500 White 762 m (2500 ft) Spool 18 spools/pallet 13716 m (45000 ft) 4824 LSZH version available upon request. To learn more about Belden IBDN copper-based structured cabling systems, call 1.800.BELDEN.1 or visit our Website at www.belden.com. Belden Technical Support 1.800.BELDEN.1 www.belden.com PB296 Copyright 2010, Belden Inc.