Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

Similar documents
Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Pulsed Laser Power Measurement Systems

It s Our Business to be EXACT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z , & ANSI/NCSL Z

OP710. Multichannel Optical Power Meter Instruction Manual. (Also supports the OP710-ANX)

Improved Radiometry for LED Arrays

UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

Power Measurment. Hand-held Design Brings Peak Performance to the Field. Introduction. Features

8480 Series Power Sensor Specifications

OP735. Benchtop Optical Power Meter Instruction Manual

671 Series LASER WAVELENGTH METER. The Power of Precision in Wavelength Measurement. It's Our Business to be Exact! bristol-inst.

# 36. Calibration and Traceability of ILX Lightwave Optical Power Meters

Ensure Optimal Instrument Performance with Genuine Agilent Long-life Deuterium Lamps

Uniform surface Led series SFL-UV

Capabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Advanced Test Equipment Rentals ATEC (2832)

Certificate of Calibration

Advanced Test Equipment Rentals ATEC (2832)

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

How-to guide. Working with a pre-assembled THz system

Calibration of ARM Spectral Shortwave Radiometers

LI-193 Spherical Quantum Sensor

Optical Information. The LDM145 laser diode modules are available with the following lens types.

Nanometers and Picometers: Keys to Success with 5 Terabit/in 2 Patterned Media

Measurements of Infrared Sources with the Missile Defense Transfer Radiometer

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

Spectroradiometer characterisations for traceable solar radiation measurements

PowerPXIe Series. Analog Power Meter ADVANCE SPEC SHEET

S.M. Vaezi-Nejad, M. Cox, J. N. Copner

Certificate of Calibration

Instruction Manual of Luminance and Spectral Radiance Calibrations

Miniature collimator for POF fiber: large aperture Model 011-TU2

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Peter Dack, Vice President Sales & Marketing Radian Research, Inc.

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Sensor Fusion Enables Comprehensive Analysis of Laser Processing in Additive Manufacturing

OPTICAL MEASURING INSTRUMENTS MS9020D GPIB OPTICAL LOSS TEST SET

Certificate of Accreditation

Premier & Acculase Modulatable Laser Diode Modules

GM8036 LASER ANALYZER SWEEP SPECTRUM OPTICAL. Technical Specifications v1.01 March, 2011

Varilite Datasheet. Thread Mountable Laser Diode Module

SEM Magnification Calibration & Verification: Building Confidence in Your Scale Bar

Coherent Laser Measurement and Control Beam Diagnostics

Keysight Technologies Using a Wide-band Tunable Laser for Optical Filter Measurements

Effect of Beam Size on Photodiode Saturation

Premier & Acculase Range Modular Modulatable Lasers

Fiber Optics. Laboratory exercise

Acculase Green PWM. Direct Drive Green Laser Diode Module

LTE. Tester of laser range finders. Integrator Target slider. Transmitter channel. Receiver channel. Target slider Attenuator 2

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Agilent N4373B Lightwave Component Analyzer Testing advanced 40Gb/s components with highest relative and absolute accuracy

Silicon Photodiodes - SXUV Series with Platinum Silicide Front Entrance Windows

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z , & ANSI/NCSL Z

TRANSFER RADIATION THERMOMETER

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Keysight N4373E 43.5/50/67 GHz Single-Mode Fiber Lightwave Component Analyzer for 100G/400G/1T Electro-Optical Test

Absolute distance interferometer in LaserTracer geometry

The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard

Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77. Table of Contents 1

High Illuminance Calibration Facility and Procedures

Certified Reference Material

E/O and O/E Measurements with the 37300C Series VNA

LI-1500 Light Sensor Logger

LP PYRA 06. REV Jan. 2007

iflex-iris Laser Systems Product features include:

CIPM and CCPR What are these organizations and how do they affect my testing results. Maria Nadal Photometry, Surface Color and Appearance NIST

TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY

Keysight Technologies 81980A, 81960A, 81940A, 81989A, 81949A, and 81950A Compact Tunable Laser Sources. Data Sheet

TRACEABLE SOLAR RADIATION MEASUREMENTS

A Global Laser Brand. FireFly Mini

LI-192 Underwater Quantum Sensor

Photonics (OPTI 510R 2017) - Final exam. (May 8, 10:30am-12:30pm, R307)

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Part 1: New spectral stuff going on at NIST. Part 2: TSI Traceability of TRF to NIST

The Report of Gain Performance Characteristics of the Erbium Doped Fiber Amplifier (EDFA)

NOW WITH BROADER TUNING RANGE

P-CUBE-Series High Sensitivity PIN Detector Modules

Agilent 8703A Lightwave Component Analyzer Technical Specifications

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Laser Telemetric System (Metrology)

Keysight Technologies 8160xx Family of Tunable Laser Sources. Data Sheet

Laser Beam Analysis Using Image Processing

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

DIGITAL VARIABLE ATTENUATOR

LINEARPYROMETER LP4. Technical Documentation KE November TN

CCT/10-13 MeP-K direct methods. Section 3.2: Absolute (spectral-band) radiometry (radiation thermometry)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Agilent 71400C Lightwave Signal Analyzer Product Overview. Calibrated measurements of high-speed modulation, RIN, and laser linewidth

YOUNGS MODULUS BY UNIFORM & NON UNIFORM BENDING OF A BEAM

1) Solar simulator with I-V measurement setup and software

Effects of Incident Optical Power on the Effective Reverse Bias Voltage of Photodiodes This Lab Fact demonstrates how the effective reverse bias

CU-LASP Test Facilities! and Instrument Calibration Capabilities"

Radiometric Measurement Traceability Paths for Photovoltaic Calibrations. Howard W. Yoon Physical Measurement Laboratory NIST

DIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS

Chameleon Spectroradiometer

Industrial quality control HASO for ensuring the quality of NIR optical components

Transcription:

Keysight Technologies Optical Power Meter Head Special Calibrations Brochure

Introduction The test and measurement equipment you select and maintain in your production and qualification setups is one of the most important parts of ensuring the quality, reliability and performance of your end product. The specified accuracy of your instrument, which gives you confidence in the measurements they produce, can only be analyzed and certified by proper calibration. Calibration of your test and measurement equipment ensures that you can trust your measurement results and have confidence in your own precision. Furthermore nearly all existing quality assurance standards, norms and procedures such as ISO/IEC 9001 or ISO/IEC 17025 require a periodic quality assessment for your test and measurement equipment. Following these standards requires you to regularly monitor your instruments by performing calibrations. Optical power meters are designed to measure optical power in a specified wavelength range as accurately as possible. Due to the fact that this capability largely depends on the quality of the calibration process, it is important to carefully select your calibration provider. Keysight Technologies, as the original equipment manufacturer for several types of optical power meters, is able to verify all specified parameters and to perform adjustments that bring out-of-specification instruments back into specification. In this way you can receive calibration services for your optical power meters that meet or even exceed your expectations on level of quality for your test and measurement systems and your end products. With the special calibration options C01, C85 and C05 Keysight offers calibration services for its optical power meter heads for lowest measurement uncertainties as metrology grade reference standards.

03 Keysight Optical Power Meter Head Brochure Keysight s Optical Power Meter Heads As an industry leader in optical power measurements, Keysight s offers a number of superior solutions that guarantee highest performance for your various applications. The 81623B, 81624B and 81626B optical power meter heads provide a 5 mm diameter photodetector area. The simple geometry and high quality detectors allows the heads to offer the highest accuracy measurements. Various connector interfaces for popular fiber connector types or bare fibers can be plugged to the front panel optical input. The optical power meter heads feature firmware-correction of range discontinuities for best linearity, variable averaging time, data logging, and min-max and stability applications. The detectors of the optical power meter heads are temperature stabilized. The spectral responsivity data (Figure 1) is stored in the head, in steps of 2 nm. Figure 1: Sample spectral responsivity of different detector types (normalized)

04 Keysight Optical Power Meter Head Brochure Special Calibration Options Calibration Options C01 and C85 Keysight s optical power meter heads, 81623B, 81624B and 81626B, are highly precise tools to accurately measure optical power. The accuracy of these versatile instruments can be further increased by an additional detector selection and special calibration performed in the factory s Optical Metrology Laboratory. The result is an optical power meter head that is calibrated with lowest measurement uncertainties and has tighter specifications. The specially calibrated optical power meters are most attractive for high accuracy calibration purposes. The calibration options include the following package of measurements: Responsivity versus wavelength Linearity over the specified measurement range Spatial homogeneity over the detector s active area Calibration Option C05 For 81624B optical power meter heads, the special calibration option C05 is available, which comprises a C01 selection/calibration and a calibration of the spectral responsivity directly at the Physikalisch-Technische Bundesanstalt (PTB), the German national metrology institute. The responsivity calibration is based on tunable laser sources around 1310 nm and 1550 nm. The optical power is transferred to the optical power meter via single mode fiber. This calibration is done against a standard traced to the PTB primary standard. The special calibration option C05 comes with a C01 calibration report and a calibration certificate from the PTB in English language, listing the relative responsivity deviation at the calibration wavelengths. Special Calibration Option C05 Wavelength 1300 nm, 1310 nm, 1320 nm and 1540 nm, 1550 nm, 1560 nm Power level 10 μw ( 20 dbm) Beam geometry Single mode fiber on head connector adaptor Keysight 81000xA Measurement uncertainty ±0.8 % Certificate PTB certificate in English language, listing the relative responsivity deviation at the calibration wavelengths. Table 1. Special Calibration Option C05

05 Keysight Optical Power Meter Head Brochure The factory s Optical Metrology Laboratory offers special calibrations, both for new power meters and power meters sent back for recalibration. Special recalibrations according to options C01 and C85 are carried out by the factory s Optical Metrology Laboratory. Please note that standard point-type recalibrations are handled by the Keysight s service centers. Calibration Methods and Equipment Responsivity versus Wavelength Keysight s Optical Metrology Laboratory uses a system based on a white-light source and monochromator filtering for the responsivity calibration of optical power meter heads according to special calibration options C01 and C85. The monochromator system consists of an electronically stabilized halogen lamp and a double monochromator for the selection of the wavelength. The spectral width is approximately 4 nm. At the output of the monochromator a lens system creates an almost parallel open beam with a numerical aperture <0.1. The collimated beam of approximately 3 mm is used to excite the center of the detector s active area. Figure 2: Spectral responsivity calibration at Keysight During calibration, the test meter is compared to the applicable higher-level standard indicated in the traceability chain. This is done by sequential stimulation of both meters with the monochromator output. During the entire procedure, an optic-electronic feedback system ensures the stability of the lamp output. Customers optical power meter heads are (re-) adjusted for zero deviation by writing appropriate correction factors, determined in 2 nm steps over the full wavelength range, into the non-volatile memory of the optical heads. The system interpolates for other wavelengths.

06 Keysight Optical Power Meter Head Brochure Linearity over the Specified Measurement Range Generally, two effects lead to nonlinearity of optical power meter heads. First, the in-range nonlinearity is observed as the difference between the change of displayed power level and the change of input power level, without changing the power meter range. Second, the ranging nonlinearity is observed as the change of displayed power level when switching from one power meter range to the next range without changing the input power level. The measurement of the nonlinearity of the optical power meter heads is accomplished by a self-calibrating superposition method. The radiation is generated by appropriate laser sources. The two laser sources for each wavelength are connected to respective optical attenuators whose outputs are combined with an optical coupler and applied to the device under test, where the power is measured. Figure 3: Linearity verification at Keysight At the beginning, the powers of the two laser sources are adjusted to previously calculated target values with the help of the two optical attenuators. Now, the power of the first laser source (P 1 ) is measured separately. Then the power of the first laser is switched off and the power of the second laser source (P 2 ), which is approximately the same, is measured separately, too. Then the sum of the two powers is measured, (P 1 +P 2 ) measured. The non-linearity is calculated from the ratio of (P 1 +P 2 ) measured to the expected sum, (P 1 +P 2 ) calculated. These steps are repeated from the lowest to the highest specified power level by doubling the power each time. The method is self-calibrating by Keysight s definition and doesn t need traceability to a national laboratory.

07 Keysight Optical Power Meter Head Brochure Spatial Homogeneity over the Detector s Active Area The optical power meter's photodetector has an active area of 5.0 mm diameter. Ideally, the responsivity of the detector would be constant over the entire active area. This would make optical power measurements independent on the diameter and position of the irradiated area. Substantial deviations from these ideal characteristics are often observed. Testing for non-uniformity is performed by scanning the detector with a homogeneous optical beam. The grid spacing is 0.25 mm, and the total number of measurement points is 21 x 21. The center of the diode s active area acts as reference point with 100 % responsivity (per definition). All measurement points within the specification area are compared against the test limit. Figure 4: Homogeneity verification at Keysight Uncertainty and Traceability Uncertainty The method of characterizing and accumulating uncertainties is based on the IEC 61315 standard Calibration of fiber-optic power meters. This takes into account the random and systematic uncertainties of all optical power meters and all transfer processes in the calibration chain according to ISO/IEC Guide 98-3 standard Guide to the expression of uncertainty in measurement (GUM). The special calibration options C01 and C85 for the optical power meter heads 81623B, 81624B and 81626B provide a significant improvement to this uncertainty. The special calibration options are compliant to the ISO/IEC 17025 standard, General requirements for the competence of testing and calibration laboratories.

08 Keysight Optical Power Meter Head Brochure Traceability Direct traceability to the Physikalisch-Technische Bundesanstalt (PTB), the German national metrology institute, has been established and is maintained. International traceability is given by round-robin comparisons of the PTB with other national laboratories, such as NIST (US), NPL (UK) and JMI (Japan), on a regular basis. Keysight s traceability chain for spectral responsivity is shown in Figure 5. Level 0: The calibration chain starts at the Physikalisch-Technische Bundesanstalt (PTB), the German national metrology institute. PTB uses thermopile radiometers, because of their flat wavelength dependence and low reflectance. Level 1: PTB regularly calibrates Keysight s reference standards for optical power. Special calibration option C05 offers direct calibration at PTB. Keysight s reference standards for optical power are electrically calibrated pyroelectric radiometer (ECPR) or photodetector-based optical power meter. Level 2: Photodetector-based Metrology Laboratory working standards. Level 3: Photodetector-based working standards used: - for special calibrations in the Keysight s optical MetLab - in production for the calibration of commercial power meters - as working standards for Keysight s service organization Level 4: Photodetector-based commercial power meters. The working standards and Keysight s commercial power meters are based on Ge and InGaAs photodetectors. Figure 5: Keysight s traceability chain for optical power

09 Keysight Optical Power Meter Head Brochure Measurement Results Optical Power Meter Head Special Calibrations For product specifications Keysight s optical power meter family with the special calibration options please refer to the corresponding data sheet (http://literature.cdn.keysight.com/litweb/pdf/5988-1569en.pdf). Best Measurement Capability Scope of Factory s Optical Metrology Laboratory Keysight s Optical Metrology Laboratory is certified according to ISO/IEC 17025 standard General requirements for the competence of testing and calibration laboratories. The laboratory is regularly internally audited with criteria specified in the Business Management System which includes requirements as stated in ISO/IEC 17025 and ISO 9001. In Table 2, the best measurement capabilities of Keysight s Optical Metrology Laboratory are listed. The Calibration and Measurement Capabilities (CMCs) presented in this scope represent the smallest uncertainties that can be reached for the given parameter for which the Metrology Laboratory is internally certified. The assigned uncertainties during calibration will be such as to properly demonstrate the performance of the equipment and may be greater than the CMCs stated in this Schedule.

010 Keysight Optical Power Meter Head Brochure Measured Quantity, Instrument or Gauge Range Spectral responsivity: Calibration and Measurement Capability (CMC) Expressed as an Expanded Uncertainty (k = 2) Remarks Specific values: 600 nm to 1020 nm 2.20% Using Si based Working-Standard. 10 nm step width; Under reference conditions as specified in the corresponding data sheet. Non-linearity: Specific values: 800 nm to 1000 nm 2.10% Using Ge based Working-Standard. 10 nm step width; Under reference conditions as specified in the corresponding data sheet. 1000 nm to 1650 nm 1.70% Using Ge based Working-Standard. 10 nm step width; Under reference conditions as specified in the corresponding data sheet. 970 nm to 1630 nm 1.50% Using InGaAs based Working-Standard. 10 nm step width; Under reference conditions as specified in the corresponding data sheet. 950 nm to 1630 nm 2.50% Using high power InGaAs based Working-Standard. 10 nm step width; Under reference conditions as specified in the corresponding data sheet. 850 nm Sensor homogeneity: -47 dbm to 3 dbm 0.02% At a ref. power level of 10 μw (-20 dbm); Step size 3 db; Divergent beam from SM fiber with NA = 0.1; At (23±5) C. 1300 nm -70 dbm to 10 dbm 0.02% At a ref. power level of 10 μw (-20 dbm); Step size 3 db; Divergent beam from SM fiber with NA = 0.1; At (23±5) C. 1550 nm -70 dbm to 10 dbm 0.02% At a ref. power level of 10 μw (-20 dbm); Step size 3 db; Divergent beam from SM 10 dbm to 20 dbm 0.40% fiber with NA = 0.1; At (23±5) C; For input power >10 mw using adaptor 81000AF. 20 dbm to 27 dbm 0.70% Specific values: 850 nm 0.25% At an optical input power level of 10 μw; Using a focused beam with Ø 0.5 mm; For spot center within a concentric circle of Ø 3.5 mm; Step size 0.25 mm. 1300 nm 0.25% At an optical input power level of 10 μw; Using a focused beam with Ø 0.5 mm; For spot center within a concentric circle of Ø 3.5 mm; Step size 0.25 mm. 1550 nm 0.25% At an optical input power level of 10 μw; Using a focused beam with Ø 0.5 mm; For spot center within a concentric circle of Ø 3.5 mm; Step size 0.25 mm. Table 2. Best Measurement Capability Scope of Factory s Optical Metrology Laboratory This information is subject to change without notice. Keysight Technologies, 2013-2017 Published in USA, December 5, 2017 5988-7520EN www.keysight.com