SPECIFICATI - Single Unit -12-24 -48 DC VOLTAGE 12V 24V 48V RATED CURRENT A A 42A CURRENT RANGE 0 ~ A 0 ~ A 0 ~ 42A RATED POWER 1200W 1920W 2016W RIPPLE NOISE (max.) Note.2 0mVp-p 200mVp-p 300mVp-p OUTPUT VOLTAGE ADJ. RANGE 10.5 ~ V 21 ~ 28V 42 ~ 56V VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% LINE REGULATI ±1.0% ±0.5% ±0.5% REGULATI SETUP, RISE TIME ±1.0% 00ms, 60ms/230VAC at full load ±0.5% ±0.5% HOLD UP TIME (Typ.) 16ms/230VAC at 75% load 10ms/230VAC at full load VOLTAGE RANGE Note.5 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.98/230VAC at full load INPUT EFFICIENCY (Typ.) 86%.5% 92% AC CURRENT (Typ.) 13A/1VAC 7A/230VAC 16A/1VAC 10A/230VAC 16A/1VAC 10A/230VAC INRUSH CURRENT (Typ.) LEAKAGE CURRENT COLD START 50A <1.1mA / 230VAC 105 ~ 125% rated output power OVER Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover PROTECTI.7 ~ 17.5V 29.5 ~ 35V 57.6 ~ 67.2V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down AUXILIARY POWER 5V @ 0.3A, 12V @ 0.8A REMOTE / CTROL By electrical signal or dry contact :short :open REMOTE SENSE Compensate voltage drop on the load wiring up to 0.5V FUNCTI DC OK SIGNAL AC OK SIGNAL OUTPUT VOLTAGE TRIM Adjustment of output voltage, possible between ~ 110% of rated output OVER TEMP WARNING Logic " High" for over temperature warning, refer to function manual, isolated signal FAN FAIL SIGNAL WORKING TEMP. -40 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ % RH non-condensing ENVIRMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT ± 0.03%/ (0 ~ 50 ) VIBRATI 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes File Name:PEC 20-07-21
SAFETY EMC (Note 4) OTHERS NOTE SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATI RESISTANCE EMC EMISSI EMC IMMUNITY MTBF DIMENSI PACKING -12 UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC I/P-O/P, I/P-FG, O/P-FG:M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A ; EN60-3-2,-3 60.1K hrs min. MIL-HDBK-217F (25 ) 295*127*41mm (L*W*H) 2Kg;6pcs/13Kg/1.04CUFT -24-48 Compliance to EN60-4-2,3,4,5,6,8,11, EN60-6-2 (EN50082-2), heavy industry level, criteria A Mechanical Specification (Single Unit) Case No. 974A Unit:mm 41 7.112.5 295 24 61 26.2 3.6 5max. 127 62.4 SVR1 46 DC OK CN501 Air flow direction 1 3 5 7 9 33 11 17 20 23 26 29 12 18 21 24 27 30 13 16 19 22 25 28 31 2 4 6 8 10 32 34 Input / Output Connector Pin No. Assignment(CN501) : Postronic PCIM34W13M400A1 Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment Pin No. Assignment Mating Housing 1,2,3,4 12 DA 17 / 22 NC 27 T-ALARM 32 FG 5,6,7,8 13 DB 18 A1 23 SDA 28 FAN-FAIL 33 AC/L Postronic 9 (signal) 19 A2 24 SCL 29 +5V-AUX 34 AC/N PCIM34W13F400A1 10 (signal) 20 A3 25 30 +12V-AUX 11 16 A0 21 A4 26 31 GND-AUX File Name:PEC 20-07-21
Block Diagram PFC fosc : 110KHz PWM fosc : KHz I/P EMI ACTIVE INRUSH CURRENT LIMITING PFC POWER SWITCHING ORING FET PFC CTROL PWM CTROL O.V.P. DETECTI CIRCUIT ORING FET CTROL TRANSCEIVERS DA/DB DETECTI CIRCUIT MCU O.T.P. AUX POWER FAN MCU 12V/0.8A AUX POWER 5V/0.3A DATA ISOLATI T-Alarm FAN FAIL SDA/SCL / PM BUS Function Description of CN501 Pin No. 1,2,3,4 5,6,7,8 9 10 11 12,13 16,18,19, 20,21 17 22 23 24 25 26 27 28 29 30 Function DA,DB A0,A1,A2, A3,A4 / NC SDA SCL T-ALARM FAN-FAIL +5V-AUX +12V-AUX Description Positive output voltage Negative output voltage. Signal Signal Connection for output voltage trimming. The voltage can be trimmed within its defined range. (Note.1) Differential digital signal for parallel control. (Note.1) Positive sensing. The signal should be connected to the positive terminal of the load. The and leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Negative sensing. The signal should be connected to the negative terminal of the load. The and leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. PMBus interface address lines. (Note.1) The unit can turn the output on and off by electrical signal or dry contact between / and +5V-AUX. (Note.2) Short () : Power ; Open () : Power ; The maximum input voltage is 5.5V. Not use. Serial Data used in the PMBus interface. (Note.2) Serial Clock used in the PMBus interface. (Note.2) Low () : When the input voltage is 87Vrms. High () : When the input voltage in 75Vrms. The maximum sourcing current is 10mA and only for output. (Note.2) High () : When the Vout % ± 5%. Low () : When Vout % ± 5%. The maximum sourcing current is 10mA and only for output. (Note.2) High () : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm. Low () : When the internal temperature (TSW1 or TSW2 short) under the limit temperature. The maximum sourcing current is 10mA and only for output(note.2) High () : When the internal fan fail. Low () : When the internal fan is normal. The maximum sourcing current is 10mA and only for output(note.2) Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin 31). The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the remote / control. Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin 31). The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by the remote / control. 31 32 33 34 GND-AUX FG AC/L AC/N Auxiliary voltage output GND. The signal return is isolated from the output terminals ( ). AC Ground connection. AC Line connection. AC Neutral connection. Note1: Non-isolated signal, referenced to the output terminals (). Note2: Isolated signal, referenced to GND-AUX. File Name:PEC 20-07-21
Derating Curve Static Characteristics 60 230VAC Input only 75 70 12V (%) 50 40 20 (%) 65 50 40 24V,48V -40-25 -10 0 30 50 60 70 (HORIZTAL) 1 1 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz EFFICIENCY vs (48V Model) DERATING (%) VS INPUT VOLTAGE EFFICIENCY (%) 94 92 88 86 INPUT / VOLTAGE -12-24 -48 >1VAC 1VAC 95% % % VAC % 75% 75% VAC % 65% 65% 84 82 10 20 30 40 50 60 70 Function Manual 1. Remote / Control The PSU can be turned / together or separately by using the "Remote /" function. / +5V-AUX 17 29 SW Between / and +5V-AUX SW Open SW Short Output 2. Voltage Drop Compensation 2.1 Remote Sense The remote sense compensates voltage drop on the load wiring up to 0.5V. Sense lines should be twisted in pairs File Name:PEC 20-07-21
2.2 Local Sense Notice : The, have to be connected to the, terminals locally in order to get the correct output voltage if the remote sensing is not used. 3. Output Voltage Trimming (1)Output voltage can be trimmed between ~110% of its rated value by the following method. (2), also need to be connected on CN501. Signal 11 9 0~5V Add on 0~5V external voltage Vout 110 OUTPUT VOLTAGE(%) 70 60 0 0.5 1.5 3 4.5 5 V EXTERNAL VOLTAGE (DC) 4. Front Panel Indicators Corresponding Signal at Function Pins Function LED Description AC-NG DC-NG T-OK T-ALARM When input voltage 87V When input voltage 75V When output voltage % ± 5% of Vo rated. When output voltage % ± 5% of Vo rated. When the internal temperature (TSW1 TSW2 short) is within safe limit When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm *Signal between function pin and "GND-AUX". * Signal PSU Output File Name:PEC 20-07-21