1586A Super-DAQ Precision Temperature Scanner. The most accurate and flexible temperature data acquisition system on the market. Fluke-Direct.

Similar documents
Fluke 2638A/05 Hydra Series III 22-Channel Data Acquisition System

Ultra-cool dry-block calibrator with best-in-class stability Technical Data. Improved process control

9190A Ultra-Cool Field Metrology Well. Ultra-cool dry-block calibrator with best-in-class stability

1594A/1595A Super-Thermometers. Recognized worldwide for ease of use and reliable accuracy

5080A Multi-Product Calibrator

Fluke 8845A/8846A Digital Multimeters Extended Specifications

Additel 875 Series Dry Well Calibrators

5790A Automated AC Measurement Standard

5520A. Multi-Product Calibrator. Extended Specifications

Additel 875 Series Dry Well Calibrators

5500A. Multi-Product Calibrator. Extended Specifications 2005

9190A Ultra-Cool Field Metrology Well

NEW! AOIP FD5 Advanced Digital Data Logger

5520A. Multi-Product Calibrator. Extended Specifications 2005

SDM3045X Digital Multimeter. DataSheet

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

High-precision process calibrator Model CED7000

Standard Resistors Precision DC Shunts Digital Thermometers Non-inductive AC Shunts Intelligent Teraohmmeter Precision Decade Standards Precision Air

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

5320A. Multifunction Electrical Tester Calibrator. Extended Specifications

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

2638A. Users Manual. HYDRA Series III Data Acquisition Unit

Fluke 170 Series True-rms Digital Multimeters

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

Keysight 34401A Multimeter

8845A/8846A 6.5 Digit Precision Multimeters

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

DC Resistance Meters 2840 Series

5502A Multi-Product Calibrator. Extended specifications

Fluke 712B and 714B Temperature Calibrators

5522A Multi-Product Calibrator Extended specifications

CALYS 150. Advanced documenting multifunction calibrator thermometer

SDM3045X Digital Multimeter. DataSheet

Portable Multi-Channel Recorder Model DAS240-BAT

CALYS 150. Advanced documenting multifunction calibrator thermometer

An Evaluation of Artifact Calibration in the 5700A Multifunction Calibrator

PRECISION TEMPERATURE SYSTEMS. Compact Modular and Upgradeable Thermometry Measurement Systems

CALYS 150. Advanced documenting multifunction calibrator thermometer

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Chapter 6 Specifications

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

Correlation of Voltage and Temperature Measurement

CALYS 100. Field precision documenting multifunction calibrator

Model 6600A Dual Source High Resistance Bridge

CALYS 75. Field documenting multifunction calibrator

8558A 8 1/2 Digit Multimeter

Multimeter Selection Guide Fluke 8508A & Agilent 3458/HFL

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

Fluke 5820A Oscilloscope Calibrator Specifications

525B Temperature/ Pressure Calibrator Superior accuracy and functionality in an economical benchtop package

high accuracy tester-calibrator PJ 6301

6135A/PMUCAL Phasor Measurement Unit Calibration System

Reflectometer Series:

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 83V and 87V Digital Multimeters

WaveAce 1000 and 2000 Oscilloscopes

N432A Thermistor Power Meter DATA SHEET

SDM3055 Digital Multimeter. DataSheet

Comparisons: DAQ970A to 34970A/34972A

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

MODEL INFORMATION. AccuBridge Model 6010D. Automated Primary Resistance/ Thermometry Bridge

Model 1140A Thermocouple Simulator-Calibrator

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

1587/1577 Insulation Multimeters

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

EX CHANNEL ISOLATED THERMOCOUPLE AND VOLTAGE MEASUREMENT INSTRUMENT

Troubleshooting. process loops. All. Application Note. Loop calibrators. ProcessMeter

Fluke 1587 FC/1577 Insulation Multimeters

by resistance bridges. Read the features common to both units and you ll understand why each is a great buy.

MODEL INFORMATION MODEL 6010D. Automated Primary Resistance/ Thermometry Bridge

FD 5 / 10 / 15. Fast acquisition module with universal synchronized inputs and embedded webserver software

Discover. Blue Box. the. Difference. High Resistance Metrology Products Guide

5075 Precision Digital Multimeter Time Electronics Calibration, Test & Measurement

Agilent Technologies 3000 Series Oscilloscopes

8588A Reference Multimeter

SDM3065X Digital Multimeter. DataSheet

Maximizing your reference multimeter, minimizing measurement uncertainties

HP 34401A Specifications 8

How to Optimize Measurement Speed of Your DAQ

PLANAR R54. Vector Reflectometer KEY FEATURES

Model 6622T Series. DCC Thermometry Bridges 6622T SERIES FEATURES

Fluke and

T3DMM6-5/T3DMM6-5-SC Data Sheet

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

SDM3055 Digital Multimeter. DataSheet

The Fluke 8508A. Reference Multimeter. Reference standard accuracy and stability, in one functionally versatile, easy to use solution

Automated Thermocouple & RTD Calibrator

Compact Signal Calibrator

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

Agilent 34970A Data Acquisition / Switch Unit

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

Transcription:

1586A Super-DAQ Precision Scanner The most accurate and flexible temperature data acquisition system on the market info@

1586A Super-DAQ Precision Scanner The 1586A Super-DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, dc voltage, dc current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab. The 1586A is ideal for applications such as thermal mapping, temperature validation, process sensor calibration, heat-treat furnace testing, process monitoring, quality control testing, and more. These applications are found in various industries including pharmaceutical, biotechnology, food processing, aerospace, and automotive. There are six key features that set the Super-DAQ apart from other products in its class: 1 Best temperature measurement accuracy 2 Flexible configuration for the factory or benchtop 3 Multiple modes of operation 4 Real-time graphing in color 5 Data portability and security 6 Automated sensor calibration info@ 2 Fluke Calibration 1586A Super-DAQ Precision Scanner

1 Best temperature measurement accuracy The 1586A Super-DAQ reads PRTs, thermocouples, and thermistors with best-in-class accuracy: PRTs ± 0.005 C (using the external DAQ-STAQ Multiplexer) Thermocouples: ± 0.5 C (using the High-Capacity Module and internal CJC) Thermistors: ± 0.002 C Current reversal minimizes thermoelectric effects improving PRT/RTD measurement accuracy Automatic internal reference junction compensation improves thermocouple measurement accuracy Accurately measure scalable transducers such as temperature and pressure transmitters using Mx + B gain and offset calculations for each channel sensor characterizations include ITS-90, CVD, Polynomial, PT385, and PT392 Probe library stores up to 100 sensor profiles simplifying setup 6-1/2 digit display resolution for dc voltage, dc current, and resistance 2 Flexible configuration for the factory or benchtop For factory applications such as temperature An Mx + B offset is stored for each channel and validation, the Super-DAQ is configured with an indicator let's you know that an offset has been the internal High-Capacity Module. Connecting applied. thermocouples or RTDs to input terminals can be The Super-DAQ includes 20 math channels and time consuming especially if you're using many 15 different mathematical operations that can be sensors of the same type for one job, and then applied to measured results. Combining calculated switching to a different sensor type for another job. results of multiple math channels lets you compute The internal High-Capacity Module allows you to complex operations such as F 0 calculations. pre-configure multiple input modules and simply For a calibration lab where accuracy is of primary exchange one module for another depending on importance, the Super-DAQ is best configured with your test requirements. Recall a stored test setup to a DAQ-STAQ Multiplexer. The external DAQ-STAQ make the changeover even faster. And if you prefer, features mini-jack thermocouple terminals each you can always measure a variety of different input with its own reference junction sensor and types at the same time in a single High-Capacity patented mini-dwf, gold-plated input terminals, Module, including thermocouples, RTDs, voltage, which accept bare wire, spade lug, or mini-bananaplug probe terminations. Easily connect and resistance, or current. To simplify applications such as temperature disconnect PRTs, thermistors, and thermocouples for uniformity testing, the Align Channels feature benchtop temperature calibration. It can be stacked allows you to automatically zero offsets between on the 1586A to reduce footprint in busy labs. sensors relative to a designated reference channel. Having the flexibility to configure the Super-DAQ for factory or lab use reduces your equipment needs and cost. 1586-2586 High-Capacity Module Universal input channels accepts 2-, 3-, or 4-wire connections to measure temperature, resistance, dc voltage, and dc current for data acquisition applications on the factory floor where channel count and scan speed are important. info@ 1586-2588 DAQ-STAQ Multiplexer Designed for high-accuracy measurements in secondary temperature calibration labs. Easily connect/disconnect thermocouples, PRTs, and thermistors. Fluke Calibration 1586A Super-DAQ Precision Scanner 3

3 Multiple modes of operation The Super-DAQ can operate in four modes that let you scan, monitor, measure, or function as a digital multimeter from a single instrument. Sequentially scan through channels based on a user defined test. Depending on your application, select a fast, medium, or slow scan rate. With scan speeds as fast as 10 channels per second, you can collect data on all 40 channels in less than four seconds. Easily capture time-stamped measurements and correlate related events. Scans can be initiated through six different trigger types to include: external trigger, time interval, remote SCPI command, alarm trigger, manual trigger, and an automated test trigger. Monitor any single channel during a scan, without interrupting the scan. Measure and record data on a single channel without pre-configuring a test file. In DMM mode, use the front panel channel like a familiar benchtop digital multimeter to quickly measure dc voltage, dc current, or 2-wire and 4-wire resistance. Function keys are backlit so that you always know the mode of operation and recording status. Scan, monitor, measure, and DMM function keys on the front panel. 4 Real-time graphing in color Most data acquisition systems only let you view data on one channel. But now, the Super-DAQ lets you view real-time data for all channels in table format or chart up to four channels in color at the same time. You can quickly see the current process state ata-glance, or easily verify that your channels have been connected and configured properly. You can zoom in or out to see data of interest and monitor trends. A history mode lets you scroll through collected data within a scan file all without a PC and expensive software. Switch between chart view and table view to see measurement data and statistics, including average, standard deviation, minimum, maximum, peak-topeak, and rate of change. Not only does the Super-DAQ include a rich graphical display, but you can also select between nine different languages including English, Chinese, French, German, Japanese, Korean, Portuguese, Spanish, or Russian. Each channel can be assigned two independent alarms which indicate when either an upper (HI) or lower (LO) range has been exceeded. If an alarm trips, the out-of-range condition is indicated on the display. Alarms can also be assigned to any of the six TTL outputs for control of external devices. The 1586A Super-DAQ graphing real time data from four input channels. info@ 4 Fluke Calibration 1586A Super-DAQ Precision Scanner

5 Data portability and security The Super-DAQ includes 20 MB of internal memory that can store over 75,000 time-stamped readings. Data and setup files can be easily moved to a PC for analysis using a USB flashdrive or over a network using the LAN interface connection. The Super-DAQ also includes two levels of data security to prevent unauthorized users from tampering with or forging test data or setup files. This security feature is especially important to industries that are regulated by government agencies where data traceability is required. Easily transfer Super-DAQ data and setup files using a USB flash drive. 6 Automated sensor calibration With the Automated Test feature, you can automate sensor calibration without a PC and software. When connected to a Fluke Calibration drywell or fluid bath via the RS-232 interface, the Super-DAQ takes control of the temperature source and runs your calibration automatically. You simply program the number of setpoint temperatures and their values, select a scan sequence (linear, alternate, up/down), assign a reference channel, and set the required stability band. The Super-DAQ monitors the temperature source's stability via the reference channel, collects the data once stabilized, and then advances to the next setpoint temperature. After you configure and start the test, you can walk away to work on other things. The Super-DAQ just made your day a whole lot easier! info@ 1586A configured with a DAQ-STAQ and 9190A Ultra-Cool Field Metrology Well for automated sensor calibration. Fluke Calibration 1586A Super-DAQ Precision Scanner 5

accuracy, 1586A with High-Capacity Module 1 PRTs and Thermistors (4-wire) PRT/RTD (100 Ω nominal) Thermistor (10 KΩ nominal) Thermocouples Range 200 C to 1200 C (depending on the sensor) 200 C to 400 C (depending on the sensor) Range Resolution Accuracy 0.001 C 0.008 C at -200 C 0.008 C at 0 C 0.018 C at 300 C 0.0001 C 0.002 C at 0 C 0.009 C at 50 C 0.024 C at 100 C Resolution Accuracy (int CJC) Thermocouple Type K 270 C to 1372 C 0.01 C 0.62 C at 0 C 0.64 C at 1000 C Thermocouple Type T 270 C to 400 C 0.01 C 0.65 C at 0 C 0.47 C at 200 C Thermocouple Type S 50 C to 1768 C 0.01 C 0.76 C at 300 C 0.60 C at 1200 C Resistance Accuracy 0.003 % or 0.003 Ω (0 to 400 Ω) 0.004 % + 0.5 Ω (600 Ω to 35 kω) Accuracy (ext CJC) 0.15 C at 0 C 0.20 C at 1000 C 0.15 C at 0 C 0.12 C at 200 C 0.67 C at 300 C 0.54 C at 1200 C Excitation Current 1 ma with current reversal 10 μa Voltage Accuracy accuracy, 1586A with DAQ-STAQ Multiplexer 1 PRTs and Thermistors (4-wire) Range PRT/RTD (100 Ω nominal) 200 C to 1200 C (depending on the sensor) Thermistor (10 KΩ nominal) Thermocouples 200 C to 400 C (depending on the sensor) Range Resolution Accuracy 0.001 C 0.005 C at -200 C 0.005 C at 0 C 0.012 C at 300 C 0.0001 C 0.002 C at 0 C 0.009 C at 50 C 0.024 C at 100 C Resolution Accuracy (int CJC) Thermocouple Type K 270 C to 1372 C 0.01 C 0.29 C at 0 C 0.32 C at 1000 C Thermocouple Type T 270 C to 400 C 0.01 C 0.30 C at 0 C 0.23 C at 200 C Thermocouple Type S 50 C to 1768 C 0.01 C 0.68 C at 300 C 0.55 C at 1200 C Resistance Accuracy Excitation Current 0.002 % or 0.008 Ω 1 ma with current reversal 0.004 % + 0.5 Ω 10 μa Accuracy (ext CJC) 0.15 C at 0 C 0.20 C at 1000 C 0.15 C at 0 C 0.12 C at 200 C 0.67 C at 300 C 0.54 C at 1200 C Voltage Accuracy 1 Accuracy specifications apply using medium sample rate (1 second per channel). Please consult the 1586A Super-DAQ Extended Specifications for additional specifications at slow (4 seconds per channel), fast (0.1 seconds per channel) sample rates and for other thermocouple types (R, J, N, E, B, C, D, G, L M, U, W). DC Voltage (medium or slow sample rate) Range Accuracy Channel 1 Ch. X01 - x20 2 Fast Sample Rate Resolution Input Impedance ± 100 mv 0.0037 % + 0.0035 % add 2 μv add 0.0008 % of range 0.1 μv 10 GΩ [1] ± 50 V 0.0038 % + 0.0012 % - add 0.0008 % of range 1 mv 10 MΩ ± 1 % 2 Ch. x01 - x20 refers to slot number and channels 1-20 for either module type. DC Current (medium or slow sample rate) Range Accuracy Fast Sample Rate Resolution Burden Voltage ± 100 μa 0.015 % + 0.0035 % add 0.0008 % of range 0.1 na < 1 mv ± 10 ma 0.015 % + 0.0035 % add 0.0008 % of range 10 na < 1 mv ± 100 ma 0.015 % + 0.0035 % add 0.0008 % of range 100 na < 1 mv info@ 6 Fluke Calibration 1586A Super-DAQ Precision Scanner

Resistance (medium or slow sample rate, 4-wire resistance) 3 Range Accuracy Fast Sample Rate Resolution Source Current 100 Ω 0.004 % + 0.0035 % add 0.001 % of range 0.1 mω 1 ma 10 kω 0.004 % + 0.001 % add 0.001 % of range 10 mω 100 μa 10 MΩ 0.015 % + 0.001 % add 0.01 % of range 1 kω 0.1 μa 3 For 2-wire resistance add 0.02 Ω internal resistance if using Channel 1, or 1.5 Ω if using channels x01 - x20, and add external lead wire resistance. General specifications Channel capacity Total analog channels 45 Sample rate Display resolution Input Module options Internal High-Capacity Module configuration External DAQ-STAQ Multiplexer configuration Math channels Triggers Voltage/resistance channels 41 Current channels 5 Digital I/O Totalizer 1 Alarm outputs 6 Trigger input 1 1 (8-bit TTL) Fast: 10 channels per second (0.1 seconds per channel) Medium: 1 channel per second (1 second per channel) Slow: 4 seconds per channel 6 1/2 digits 2 rear panel slots ( x designates slot 1 or slot 2 below). Can be configured for 2 High-Capacity Modules, 2 DAQ-STAQ Multiplexers, or one of each 20 channels per module (x01 - x20) 2 dedicated current channels (x21 - x22) (3- and 4-wire connections require 2 channels) 10 PRT/thermistor channels (maximum) 20 mini-jack thermocouple channels (maximum) 20 channels Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum Interval, external (trigger input), alarm, remote (bus), manual, automated test Memory Scan data RAM 75,000 readings with timestamp Standard interfaces Mains voltage Mains frequency Input protection Internal memory 20 MB USB host, USB device, Ethernet 10/100 LAN, RS-232 temperature source control for automated temperature data collection from Fluke Calibration drywells and baths 100 V setting: 90, to 100 V; 120 V setting: 108, to 132 V; 220 V setting: 198, to 242 V; 240 V setting: 216, to 264 V 47 Hz to 440 Hz 50 V all functions, terminals and ranges Dimensions Height x Width x Depth 150 mm x 245 mm x 385 mm (5.9 in x 9.6 in x 15.2 in) Conformity Weight Shipping Weight CE, CSA, IEC 61010 3rd edition 6 kg (13.2 lb) typical configuration 9.5 kg (20.9 lb) typical configuration info@ Fluke Calibration 1586A Super-DAQ Precision Scanner 7

Ordering information Models Description Super-DAQ and High-Capacity Module 1586A/1HC Super-DAQ, 1 High-Capacity Module 1586A/1HC /C Super-DAQ, 1 High-Capacity Module, 1586A/2HC Super-DAQ, 2 High-Capacity Modules 1586A/2HC /C Super-DAQ, 2 High-Capacity Modules, Super-DAQ and DAQ-STAQ Multiplexer 1586A/1DS Super-DAQ, 1 DAQ-STAQ Multiplexer 1586A/1DS /C Super-DAQ, 1 DAQ-STAQ Multiplexer, 1586A/2DS Super-DAQ, 2 DAQ-STAQ Multiplexers 1586A/2DS /C Super-DAQ, 2 DAQ-STAQ Multiplexers, Super-DAQ, High-Capacity Module, and DAQ-STAQ Multiplexer 1586A/DS-HC Super-DAQ, 1 High-Capacity Module, 1 DAQ-STAQ Multiplexer 1586A/DSHC /C Super-DAQ, 1 High-Capacity Module, 1 DAQ-STAQ Multiplexer, Accessories 1586-2586 High-Capacity Module without Relay Card 1586-2586-KIT High-Capacity Module with Relay Card 1586-2588 DAQ-STAQ Multiplexer 1586-2588-KIT DAQ-STAQ Multiplexer, Adapter Card, Interface Cable 1586-2588-CBL DAQ-STAQ Multiplexer Interface Cable Y1586S Rack Mount Kit, Single (Half Rack) Y1586D Rack Mount Kit, Dual (Full Rack) 1586-CASE Super-DAQ Carrying Case (Mainframe and Internal Modules) 1586/DS-CASE Super-DAQ/DAQ-STAQ Multiplexer Carrying Case (Mainframe and External Module) 1586A/1HC 1586A/1DS 1586A/1DS-HC Fluke Calibration. Precision, performance, confidence. Fluke Calibration PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands info@ For more information call: In the U.S.A. (877) 355-3225 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.flukecal.com 2013 Fluke Calibration. Specifications subject to change without notice. Printed in U.S.A. 10/2013 6000791B_EN Pub-ID 12126-eng Modification of this document is not permitted without written permission from Fluke Calibration.