MS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM

Similar documents
CERTIFIED SENSOR "SANITARY". SPECIFIC FOR THE USE IN ALIMENTARY

FAST SAMPLING CONVERTER

OPTIFLUX 5000 Technical Datasheet

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

OPTIFLUX 5000 Technical Datasheet

Warranty conditions are available on this website: only in English version

( F L O W I Z F A M I L Y )

Ambient Conditions. Operating Conditions. Pressure

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

FLOMID FX Electromagnetic Flowmeter

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

OPTIFLUX 1000 Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Magnetic Inductive Flow Sensor induq

OPTIFLUX 2000 Technical Datasheet

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

Digital flow ELEMENT transmitter for continuous flow measurement

WATERFLUX 3000 Quick Start

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Electromagnetic Flow Transmitter

Digital inductive conductivity transmitter

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Technical Information Smartec CLD18

Digital flow ELEMENT transmitter for continuous flow measurement

ph or ORP Transmitter

Digital flow transmitter for continuous flow measurement

Flow Measurement SITRANS F M

BATCHFLUX 5500 C Technical Datasheet

Condumax CLS15 and CLS15D

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

WATERFLUX 3000 Quick Start

Technical Information Smartec CLD18

Electro-Magnetic Flowmeters COPA-XE

INLINE flowmeter for continuous flow measurement

FLOWIZ ( M L ) Warranty conditions are available on this website: only in English version

FMG90 Series Electromagnetic Flow Meter

The transducer component converts the measured signal and displays the actual value.

Pressure Transmitter SIL

Technical Information Condumax CLS15D/CLS15

Conductivity Transmitter

INLINE flowmeter for continuous flow measurement

FH CMF Coriolis Mass Flow Meters

Condumax CLS21 and CLS21D

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

INLINE flowmeter for continuous flow measurement

Magnetic Inductive Flow Sensor

Digital conductivity transmitter

INSERTION paddle wheel flowmeter for continuous flow measurement

PLATINUM SENSORS FOR MEASURING TEMPERATURES UP TO 400 C 28.11a

Technical Information Smartec CLD18

WATERFLUX 3070 Technical Datasheet

ED701 General Industry Pressure Transmitter

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H

Condumax CLS15 and CLS15D

Condumax W CLS15 and CLS15D

Technical Information Condumax CLS21D/CLS21

Resistance thermometers for process technology

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

FSM4000 Electromagnetic Flowmeter. Measurement made easy. The all-purpose flowmeter for conductive fluids

ABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter

OPTIFLUX 1000 Handbook

Electromagnetic Flowmeter Comet F

Mass Flowmeter CoriolisMaster FCM2000

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution. sitrans f

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Mass Flowmeter CoriolisMaster FCM2000

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

Technical Information Proline Promag 10P

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Magnetic Inductive Flow Sensors VMI Series

Proline Promag 55S. Technical Information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

IFC 100 Technical Datasheet

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Flush pressure transmitter For viscous and solids-containing media Model S-11

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

prosonic T FMU230, FMU231

Advanced instrumentation solutions crafted with highest precision

Condumax CLS21 and CLS21D

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

OPTIFLUX 4000 Handbook

Magnetic Inductive Flow Sensors induq. Series VMI

FSM4000 Electromagnetic Flowmeter. The all-purpose flowmeter for conductive fluids

Technical Information Memosens CLS82D

KFS. Flap-type flow meter. Design and range of application

Design and applications

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Specifications ELECTROMAGNETIC FLOWMETER. LF664/LF620 LF664/LF to 78 (500 to 1950mm) Overall Specifications TIC-LF664K

Magnetic-Inductive flow Meter fmi

MAGNETIC INDUCTIVE FLOW SENSORS

Transcription:

CIAO SENSOR MS 5000 EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM Warranty conditions are available on this website: www.isomag.eu only in English version

INDEX TECHNICAL DATA... 3 OVERALL FEATURES... 3 STANDARD FEATURES... 3 OPTIONAL FEATURES... 3 OVERALL DIMENSIONS... 4 INSTALLATION... 5 INSTALLATION RECOMMENDATION... 6 SEPARATE VERSION... 7 PRESSURE LOSS CALCULATION... 8 (CONES 8 ANGLES)... 8 HOW TO ORDER... 9 The Manufacturer Guarantee Only English Text Page 2 of 9 MS5000_EN_DS018REV04_IS.docx

T E C H N I C A L D A T A OVERALL FEATURES Nominal diameter DN 25 50 80 Minimum conductivity 5 S/cm Humidity Range 0 100% (IP 67) Accuracy See relevant converter data sheet CE Certification Yes STANDARD FEATURES Body material Polyurethane rubber Nominal pressure 600 kpa Process connection Wrapper fixing Version protection rating Compact IP67 Lining material Polyurethane rubber Gasket material FPM Liquid temperature 0 C 50 C Vacuum resistance 20 Kpa a 50 C SS AISI 316L Electrodes material Hastelloy C Titanium OPTIONAL FEATURES (CHECK FOR MORE DETAILS HOW TO ORDER ON LAST PAGE) Gasket material EPDM Version protection rating Separate (max 20m) IP 68 The Manufacturer Guarantee Only English Text Page 3 of 9 MS5000_EN_DS018REV04_IS.docx

2.0 A 25 70 MS 5000 O V E R A L L D I M E N S I O N S 100 18 L DN 70 PIPE Ø DIMENSIONS mm 25 (1") 50 (2") 80 (3") A 80 124 154 L 135 160 190 PIPE Ø (ISO) 33.7 60.3 88.9 The Manufacturer Guarantee Only English Text Page 4 of 9 MS5000_EN_DS018REV04_IS.docx

I N S T A L L A T I O N DN L (mm) L (inches) 25 92 3.62 50 108 4.25 80 138 5.43 L FIXING THE SCREWS * Lock the pipe to a fixed support Verify the flow direction Assemble the sensor to the pipe Tighten the wrapper to avoid possible leakages Connect the instrument to ground by the screw attachment on sensor LOCK THE PIPE * The Manufacturer Guarantee Only English Text Page 5 of 9 MS5000_EN_DS018REV04_IS.docx

I N S T A L L A T I O N R E C O M M E N D A T I O N In vertical installations an ascending flow is preferable. For vertical installations with descending flow direction contact the manufacturer. For installations in long pipe lines, please use anti vibration joints GIUNTI ANTIVIBRANTI CONDOTTE LUNGHE Avoid the functioning with partially empty pipe, during the functioning the pipe must be either completely full of liquid or completely empty Install the sensor away from bends and hydraulic accessories 3 X DN 2 X DN The Manufacturer Guarantee Only English Text Page 6 of 9 MS5000_EN_DS018REV04_IS.docx

CONDUCTIVITY (µs/cm) MS 5000 S E P A R A T E V E R S I O N LOCK THE PIPE * 200 150 100 ML110 ML210/ML211/ML212 50 5 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 CABLES LENGHT (m) Notes: It is recommended to install the connection cables away from, or protect against sources of electromagnetic noise. The minimum conductivity of the liquid medium to ensure correct functionality of the empty pipe detection is 20 µs/cm The Manufacturer Guarantee Only English Text Page 7 of 9 MS5000_EN_DS018REV04_IS.docx

P R E S S U R E L O S S C A L C U L A T I O N ( C O N E S 8 A N G L E S ) d D 8 8 Where: p 0.10 0.20 d D 2 1 2 d D 4 2 u 2 p = Pressure loss in [Pa] = Fluid density [kg/m 3 ] typical value d = sensor diameter [m] 3 1000[ kg/ m D = pipe diameter (greater than sensor diameter) [m] u = Mean flow velocity in sensor diameter [m/s] ] Calculation examples p [mbar] u d/d 1 [m/s] 2 [m/s] 3 [m/s] 4 [m/s] 5 [m/s] 6 [m/s] 7 [m/s] 8 [m/s] 0.5 1.1 4.3 9.6 17.0 26.6 38.3 52.1 68.0 0.6 0.9 3.6 8.2 14.6 22.7 32.7 44.6 58.2 0.7 0.8 3.0 6.8 12.2 19.0 27.4 37.2 48.6 0.8 0.6 2.5 5.7 10.1 15.7 22.7 30.9 40.3 0.9 0.5 2.1 4.8 8.6 13.4 19.3 26.3 34.3 Note : 3 1000[ kg/ m ] as goodness approximation of water density in common use. Inner diameter of sensor is used for d, express in meters. Indeed pressure loss equation is dimensionally correct in [Pa]. The equation results in table are show in [mbar]. The Manufacturer Guarantee Only English Text Page 8 of 9 MS5000_EN_DS018REV04_IS.docx

H O W T O O R D E R Example code MS 5000 Nominal Diameter / Lining / Liquid temperature / Measuring range C25 DN25 (1"), measuring range 0...0,73/0...18 m3/h C25 C50 DN50 (2"), measuring range 0...2,92/0...72 m3/h C80 DN80 (3"), measuring range 0...7,50/0...184 m3/h Gasket material ( internal tightness ) A A Without gasket Number and electrodes material 2 n. 3 measure electrodes in AISI316 2 4 n. 3 (2 measure + 1 for ground) electrodes in Hastelloy C 5 n. 3 (2 measure + 1 for ground) electrodes in Titanium Version / Classe di protezione sensore A A Compact execution, IP67 protection rate, liquid maximum temperature 50 C Separate execution, maximum length 20m, remember to added the cables cost, protection rate B IP68 (standing immersion with 1,5 m of head water) M Compact execution, IP67 protection rate, with the possibility to turn the converter of 90 MS5000-C25-A2A (Complete code example for order) The manufacturer reserves the right to make design improvements without notice. Production / stock 35044 Montagnana PD Via Piemonte, 2