USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Similar documents
User s Guide. Model MA A AC Mini Clamp-on Meter

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

User Guide. AC/DC Mini Clamp Meter. Model

400Amp True RMS AC Clamp Meter + NCV

200Amp AC Clamp Meter + NCV Model MA250

400Amp True RMS AC/DC Clamp Meter Model EX613

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

R/C SMD Tweezers Multimeter Model RC200

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. Digital AC/DC Clamp Meter Model 38394

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

User Guide. Digital AC/DC Clamp Meter Model 38394

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

Compact MultiMeters + Voltage Detector

True RMS AC / DC Power Clamp Meter Model

USER'S MANUAL DMR-6700

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Autoranging Multimeter Extech EX503

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

AC Clamp Meter + Phase Rotation Tester

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

MS2030 CAT III 600 V A V AUTO RS232

ET-3888 True RMS Clamp Meter. User Manual

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Digital Clamp Meter. User Manual

AC/DC CLAMP METER USER S MANUAL

MODEL: D03128 CLAMP METER

Pen-type DIGITAL MULTITESTER

User Manual 4 wire Earth Resistance Tester Model GRT300

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

OPERATOR S INSTRUCTION MANUAL

NOTE: Fully read and understand this manual before using this Digital Multimeter.

OPERATING INSTRUCTION

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Multifunction Digital

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Operating Instructions 22070T True RMS AC/DC CLAMP METER Instrucciones de uso. Pinza amperimétrica de CA/CC de RMS verdadera

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Digital Clamp Meter Model: &

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Pen Multimeter. Model

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

User Manual Digital Multimeter

Not for Reproduction

Mini Clamp Meter Model:

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

AMM-1022 Digital Multimeter USER`S MANUAL

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

CONTENTS MS2033A. 1.Introduction Safety Information...01

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Model: &

2000 A DCA/ACA CLAMP + DMM,

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Digital Multimeter, Pen Type

Model DIGITAL MULTIMETER

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

Dawson DDM190. Digital Multimeter User s Manual

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

DIGITAL MULTIMETER AUTORANGING

Digital Clamp Meter (TRMS) Model : 2727

DIGITAL CLAMP METER Use s Manual

User Manual Digital Clamp Multimeter. model no.: MSR-C600

ATK Clamp Meter

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

Sales: Technical: Fax:

DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

AC FLEXIBLE CURRENT PROBE CA 3000

Digital Multimeter with Backlight

Transcription:

USER MANUAL Model MA150 200A AC Mini Clamp-on Meter Additional User Manual Translations available at www.extech.com

Introduction Thank you for selecting the Extech MA150 AC Mini Clamp Meter. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version and translations of this User Manual, Product Updates, Product Registration, and Customer Support. Meter Description 1. Current sense jaw 2. Non-contact AC voltage indicator light 3. Flashlight button 4. Rotary function switch 5. MAX hold and Backlight key 6. LCD display 7. Clamp trigger 8. MODE key 9. COM input jack 10. V Ω input jack 9 10 Safety Information! Caution! Refer to the explanation in this Manual Double Insulation This meter has been designed to be safe in use, but the operator must use caution in its operation. The rules listed below should be carefully followed for safe operation. 1. NEVER apply voltage or current to the meter that exceeds the specified maximum: 2. USE EXTREME CAUTION when working with voltages greater than 60VDC or 25VAC rms. These voltages are considerd a shock hazard. 3. NEVER operate the meter unless the back cover and the battery/fuse door are in place and fastened securely. Function AC Current AC/DC Voltage Resistance, Diode, Continuity Test Input Limits Maximum Input 200A 600V AC/DC 600V AC/DC 2

Operation AC Current Measurements 1) Set the Function switch to the 200A AC range. 2) Press the jaw trigger and clamp around, fully enclosing a single conductor. Do not allow a gap between the two halves of the jaw. Refer to the diagram at right for the correct way to enclose a single conductor. 3) Read the ACA value on the LCD. AC/DC Voltage Measurements 1) Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal. 2) Set the function switch to the V position. 3) Select AC or DC with the MODE button. 4) Connect the test leads in parallel to the circuit under test. 5) Read the voltage measurement on the LCD display. Yes No Resistance and Continuity Measurements 1) Insert the black test lead into the negative COM terminal and the red test lead into the positive V Ω terminal. 2) Set the function switch to the Ω position. 3) Use the MODE button to select resistance. The MΩ icon will appear in the display. 4) Touch the test leads across the circuit or component under test. It is best to disconnect one side of the device under test so the rest of the circuit will not interfere with the resistance reading. 5) For Resistance tests, read the resistance on the LCD display 6) For Continuity, use the MODE button to select continuity ))). The display icons will change when the MODE button is pressed. 7) If the resistance is <120 Ω the meter s beeper will sound. Diode Test 1) Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V Ω jack. 2) Set the function switch to the Ω position. 3) Press the MODE button to indicate on the display. 4) Touch the test probes to the diode under test. Forward voltage will typically indicate 0.400 to 0.700V. Reverse voltage will indicate OL. Shorted devices will indicate near 0V and an open device will indicate OL in both polarities. 3

Non-Contact AC Voltage Detection WARNING: Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation 1) AC Voltage detection operates on any of the three Function switch positions. 2) Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet. 3) If AC voltage is present, the detector light will illuminate. NOTE: The conductors in electrical cord sets are often twisted. For best results, slowly slide the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor. NOTE: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly turn the detector light on. This is normal operation MAX Hold To hold the highest reading on the LCD, short press the MAX key. The meter reading will not change as readings change, rather it will only display the highest reading encountered since the MAX hold button was pressed. Press the MAX hold button again to return the meter to normal operation. Backlight Press and hold the MAX key for more than one second to turn the backlight on. This will also activate the MAX Hold function. To release the MAX Hold function and return the meter to normal operation, short press the MAX key. The backlight will automatically turn off after 15 seconds. To manually turn off the backlight, press and hold the MAX key for more than 1 second. Flashlight Press and hold the top button to turn the flashlight on. Release the button to turn the flashlight off. 4

Specifications General Specifications Display 2000 count Digit LCD with white LED backlight Polarity Minus sign (-) indicates negative polarity Jaw opening 18mm (0.7 ) Current sensor Hall effect sensor type AC Current Bandwidth 50/60Hz AC Voltage Bandwidth 50/400Hz Overload indication OL displayed on the LCD Display rate 2 readings/second, nominal Battery Two 1.5V AAA batteries Low Battery indication BATT displayed on the LCD Auto Power off approx. 15 minutes Operating conditions 0 to 30 º C (32 to 86 º F) 90%RH; 30 to 40 º C (86 to 104 º F) 75%RH; 40 to 50 º C (104 to 122 º F) 45%RH Storage conditions -30 to 60 º C (-14 to 140 º F); < 90% Relative Humidity Altitude Operate at less than 3000 meters Weight 176g (6.2 oz.) including battery Dimensions 164 x 65 x 32mm (6.5 x 2.6 x 1.3 ) (HWD) Standards For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995): EN61010-1 (1995) Overvoltage Category III 300V and Category II 600V, Pollution Degree 2. CC 5

Range Specifications Function Range Resolution Accuracy (of reading) AC Current 200.0A 0.1A ± (2.5% rdg + 10 digits) DC Voltage 200.0mV 0.1mV ±(0.5% rdg + 5 digits) 2.000V 1mV 20.00V 10mV ±(1.2% rdg + 3 digits) 200.0V 0.1V 600V 1V ±(1.5% rdg + 3 digits) AC Voltage 2.000V 1mV 20.00V 10mV ±(1.5% rdg + 3 digits) 200.0V 0.1V 600V 1V ±(2.0% rdg + 4 digits) Resistance 200.0Ω 0.1Ω ±(1.0% rdg + 4 digits) 2.000kΩ 1Ω 20.00kΩ 10Ω ±(1.5% rdg + 2 digits) 200.0kΩ 100Ω 2.000MΩ 1kΩ ±(2.0% rdg + 3 digits) 20.00MΩ 10kΩ ±(3.0% rdg + 5 digits) Non-Contact AC Voltage Diode Test Continuity 100VAC to 600VAC 50/60Hz Test current: 0.3mA typical; Open circuit voltage: 1.5VDC typical Threshold <120Ω Test current <1mA 6

Maintenance WARNING: To avoid electrical shock, remove the test leads, disconnect the meter from any circuit and turn OFF the meter before opening the case. Do not operate with an open case. Battery Replacement 1) When the low battery symbol appears on the LCD the batteries must be replaced. 2) Power down and remove the Phillips head screw that secures the battery compartment at the back of the meter. 3) Open the battery compartment and replace the two 1.5V AAA batteries observing correct polarity. Re-assemble the meter before use. Safety: Please dispose of batteries responsibly; never dispose of batteries in a fire, batteries may explode or leak. If the meter is not to be used for 60 days or more, remove the battery and store separately. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end-oflife devices to a designated collection point for the disposal of electrical and electronic equipment. Copyright 2013 2017 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www.extech.com 7