Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Similar documents
Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

INSTRUCTION MANUAL (ATEX / IECEx)

Relative and absolute pressure transmitter type 528

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

ED701 General Industry Pressure Transmitter

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Relative and absolute pressure transmitter type 528

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Inductive sensor slot-type SI2-K08-AP7

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

SALES SERVICE +358 (0)

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

DPharp Differential Pressure and Pressure Transmitters

Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Relative pressure transmitter type 522 for shipbuilding

Technical Data. General specifications. Rated operating distance s n 3 mm

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

SUNSTAR 传感与控制 TEL: FAX: Relative and absolute pressure transmitter type 528

KFS. Flap-type flow meter. Design and range of application

Design and applications

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Industrial Pressure Transducers

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

SATRON VB Pressure Transmitter

MANUAL HYDROBAR. Manufactured by: Fax: H/US/Hydrobar/ /00 Klay Instruments Page 1

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Pressure transmitter AKS 32 and AKS 33

PRetrans Table of contents

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

OPTIWAVE 7300 C Supplementary instructions

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Loop Powered Indicator

CombiTemp TCR6 Standard RTD temperature sensor

MANUAL HYDROBAR. Manufactured by: 7991 CZ DWINGELOO 7990 AA DWINGELOO The Netherlands

Pressure Transmitter SIL

OEM radar transmitter, for aggressive media level measurement

Positioner with HART Communication Type 3780

PAD - Heavy Duty Differential Pressure Trasmitter

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Installation & Operating Manual. iwap202

OPTITEMP TT 10 C/R Technical Datasheet

Heavy duty pressure controls Type MBC 5000 and MBC 5100

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Resistance thermometer Model TR30, compact design

Trimod Besta Level Switch type I 8 / IE9 8

KMS-2 Exia Magnetostrictive Level Transmitter

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Installation guide 971 SmartRadar LTi

Operating Manual. isolate501

LEO RECORD Ei Intrinsically Safe Digital Manometer with Record Function for use in Hazardous Applications. Accuracy: 0,1 %FS

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Certificate of Conformity

MINI MCR-SL-UI-I-LP-NC

Certificate of Compliance

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

Pharma Temperature Sensor TFP-EX

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

DTR.PCE.PRE-28.02(ENG) APLISENS MANUFACTURE OF PRESSURE TRANSMITTERS AND CONTROL INSTRUMENTS USER S MANUAL

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Ultrasonic level measuring device, non-contact

Rudder or propeller angular position transmitter KINAX WT720

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

... for hydraulic and general applications in hazardous areas

Temperature sensor with integrated transmitter for maritime applications, MBT 5560

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1

Rosemount 520 Level Transmitter. Quick Start Guide , Rev AB July 2016

SITRANS P. Transmitters for level. Introduction 1/42. Application

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Temperature Input Module for Zone 1 Series 9482/32

Pressure transmitter For general industrial applications Model A-10

Introduction. Additional Information. Temperature transmitter for HART protocol. Suitable for all standard requirements. Measurement made easy

Electronic Pressure Switch Type MEP

Annexe to: IECEx SIR U Issue 5 Redapt Engineering Co. Limited Electrical Component: Ranges of Adaptor, Reducers and Stopping Plugs

Power supply. Calibration. Surface finishing. Seal. Process connection

Safety Manual. Omni-ID UHF Tags

High-quality pressure transmitter For general industrial applications Model S-10

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

TQ 401 / EA 401 / IQS 450. Proximity measuring system. IECEx. » From the Vibro-Meter product line» Non-contact measurement system based on

SET Installation and Operating Instructions. Level switch for two sensors

Differential-Hall-Effect based Sensors Ex ia for Detection of Speed and Direction of Rotation in Hazardous Areas Zone 0 or 1 Series A5S1DD3 / A5S1DS3

Transcription:

060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions 6 Electrical connection 6 Maintenance/adjustment Description/Application Application: Pressure measurement in potentially explosive areas. Approval: Ex ia IIC T6...T4 (MBS 42xx series) and Ex ia IIC T4 (MBS 47xx series) in accordance with ATEX directive 2014/34/EU. Function: Pressure transmitters type MBS 4201, MBS 4251, MBS 4701 and MBS 4751 convert the pressure measured to a 4 20 ma current signal. Danfoss 060G9056 060R9345 Danfoss DCS (im) 2017.07 IC.PI.P20.C7.02 520B7682 1

Identification Supply voltage 3316 6430 Nordborg Denmark PRESSURE TRANSMITTER MBS 4701-2011-1AB08 060G4307 Code number Output signal Range P e : 0...10 bar 0...1 Mpa PB/MWP : 2 MPa/20 bar SUPPLY : 10...28 V d.c. OUTPUT : 4...20 ma +SUPPLY : PIN 1 -COMMON : PIN 2 0539 II 1G DEMKO 01 ATEX 127938X Ex ia IIC T4 Ga IECEx ULD 12.0005X Ui : 28V For : Ii : 100 ma Ambient Pi : 0,7 W temperature Li : 8 µh See: Ci : 50 nf user instruction 02803111 Made in China 111 = WWY Production - week/year (WW/Y) Electrical connection 02803 = Serial no. Type no. (Indicates transmitter specification - see key below) Type no. MBS 4201- MBS 4251- MBS 4701- MBS 4751-1 Measuring range 0 1 bar... 0 1.6 bar... 0 2.5 bar... 0 4 bar... 0 6 bar... 0 10 bar... 0 16 bar... 0 25 bar... 0 40 bar... 0 60 bar... 0 100 bar... 0 160 bar... 0 250 bar... 0 400 bar... 0 600 bar... Max. 600 bar... 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 XX Pressure connection G B 0 4... DIN 3852-E-G1/4, Gasket: DIN 3869-14-NBR A B 0 8... G1/2A (EN 837) A C 0 4... 1/4-18 NPT A C 0 8... 1/2-14 NPT F A 0 8... ISO 6149-2, M14x1.5-6g, O-ring 11.3x2.2, NBR D A 0 5... M10 x 1 female with flange connection 1 ) 1 ) Only MBS 4201 and MBS 4251 Electrical connection 1... Plug, DIN 43650, Pg9 3... 2 m cable 1 ) 7... Plug, DIN 72585-A1-3.2-Sn 4... 5 m PVC cable 1 ) 5... 10 m PVC cable 1 ) C... 6 m ETFE cable 1 ) D... 12 m ETFE cable 1 ) 1 ) Only MBS 4201 and MBS 4251 Output signal 1... 4 20 ma Pressure reference 1... Gauge 2... Absolute 2 520B7682 IC.PI.P20.C7.02 Danfoss DCS (im) 2017.07

Specifications Output current Supply voltage 4 20 ma 10 28 V Safety specifications Electrical Max. supply voltage Ui 28 V Max. Input current Ii 100 ma Max. Input power Pi 0.7 W Internal capacity Ci 50 nf Internal inductance Li 8 μh Adjustable Type (MBS47x1-xxxx-1xxxx, MBS47x1-xxxx-7xxxx): Ambient temperature T4-40 100 C Media temperature T4-40 125 C Plug Type, non-adjustable (MBS42x1-xxxx-1xxxx;; MBS42x1-xxxx-7xxxx): T4-40 100 C Ambient temperature Media temperature T5-40 75 C T6-40 50 C T4-40 125 C T5-40 95 C T6-40 50 C Fixed Cable Types, non-adjustable, MBS 42x1-xxxx-Yxxxx (Y =3, 4, 5, C, D are indicative cable lengths, max. 12 m) 3, 4, 5 PVC cable C,D. ETFE cable T4-40 80 C -40 95 C Ambient temperature (fixed installations) Ambient temperature (cables flexed during installation or operation) Media temperature T5-40 75 C -40 75 C T6-40 50 C -40 50 C T4-5 70 C -5 70 C T5-5 70 C -5 70 C T6-5 50 C -5 50 C T4-40 125 C -40 125 C T5-40 95 C -40 95 C T6-40 50 C -40 50 C Pressure specification Measuring range bar 0 1 0 1.6 0 2.5 0 4 0 6 0 10 0 16 0 25 0 40 0 60 0 100 0 160 0 250 0 400 0 600 Overload (Static) bar 6 12 24 24 60 60 150 150 300 360 600 1200 1500 1500 1500 Burst pressure bar 100 100 100 100 100 100 150 150 400 800 1200 1200 2000 2000 2000 Danfoss DCS (im) 2017.07 IC.PI.P20.C7.02 520B7682 3

Safety Instructions DIN 43650, Pg 9 DIN 72585-A1-3.2-Sn Materials of electrical connections Glass filled polyamid, PA 6.6 Glass filled polyester, PBT PVC cable or ETFE Protection IP65 IP67 / IP69K IP67 Safety instructions All national safety regulations must be complied with in connection with installation, start-up and operation of Danfoss pressure transmitters type MBS 4201, MBS 4251, MBS 4701 and MBS 4751. Furthermore, the requirements of the Declaration of Conformity and national regulations for installation in explosion areas apply. Disregarding such regulations involves a risk of serious personal injury or extensive material damage. Work in connection with the pressure transmitters mentioned must be performed only by suitably qualified persons. Basic safety and health requirements are fulfilled through compliance with: EN60079-0: 2012, IEC60079-0: 6th edition, EN60079-11: 2012, IEC60079-11: 6th edition, EN60079-26: 2007, IEC60079-26: 2nd edition. Special Ex protection instructions: In the event of damage to enclosure or diaphragm, the pressure transmitter must be replaced. The end user must ensure the installation is made in accordance to IEC/EN60079-25 and IEC/EN60079-14. WARNING Potential Electrostatic Charging Hazard. The transmitter must only be installed in surroundings with low wind speed, and where rubbing on the plug is unlikely. Cleaning with a damp cloth is recommended. To avoid build -up of electrostatic discharge it must be ensured the pressure connection of the pressure transmitter is having a reliable connection to earth with an impedance no exceeding 1 Gohm. The MBS transmitters do not provide isolation meeting the dielectric strength requirements of IEC/EN60079-11. MBS transmitters contain 10 nf capacitance from any input terminal to earth. Special conditions for safe use in accordance to the ATEX/IECEx certificate: For installations in which both the Ci and Li of the connected apparatus exceeds 1% of Co and Lo parameters (excluding the cable), then 50% of Co and Lo parameters are applicable and shall not be exceeded. Special precautions are necessary to reduce the risk due to electro-static discharge. The transmitter must only be installed in surroundings with low wind speed, and where rubbing the plug is unlikely. Cleaning with a damp cloth is recommended. The installation shall ensure that the resistance to earth of metallic parts of the equipment enclosure is less than 1 GOhm. The equipment does not provide 500 V isolation to earth as required by IEC/EN60079-11: clause 6.3.12. Installations of the pressure connection across boundary walls requiring Category 1G equipment and a less hazardous area must be gas tight as required by IEC/EN60079-26. Gaskets and seals used at the pressure connection must be suitable for use with the process medium. Special instruction when adjusting MBS 47xx series: If possible only adjust the MBS in non-hazardous area or take precaution to avoid electrostatic discharge and ensure the earthen of the transmitter housing is maintained. The transmitter must always be supplied from an intrinsic safety barrier. Demands on the medium: Parts in contact with the medium are made of stainless steel, EN 1088-1 1.4404 (AISI 316L). The user is responsible for a careful analysis of all process parameters when materials have to be specified and for ensuring the process medium is neutral to stainless steel as some media can be corrosive. The end user must ensure that the process connection is gas tight (as required by IEC/EN60079-26) which may require the use of a suitable gasket/seal in combination with the process connection to obtain a gas-tight connection. Gaskets and seals used at the pressure connection, including those supplied with the transmitters, must be determined as being suitable for use with the process medium and process pressure/temperature before use and alternative gasket material chosen if necessary. The end user must ensure the transmitter pressure connection is tightened with the correct torque as required for the specific thread type. In case of problems please contact: Danfoss A/S DK-6430 Nordborg Denmark You find the EC-Type Examination Certificate at: www.ia.danfoss.com/atexcertificate 4 520B7682 IC.PI.P20.C7.02 Danfoss DCS (im) 2017.07

Installation/dimensions MBS 4201 MBS 4251 MBS 4701 MBS 4751 MBS 4201 MBS 4251 Danfoss 060G9055 41 ø33.5 35 87 2 x ø5.4 15 DIN3852-E-G1/4 Gasket: DIN 3869-14-NBR G1/2 A (EN 837) 1/4 18 NPT 1/2-14 NPT ISO 6149-2 M14 x 1.5-6g incl. O-ring NBR 20 30.7 Flange connection M10 x 1 Dimensioned sketch - Example Danfoss DCS (im) 2017.07 IC.PI.P20.C7.02 520B7682 5

Electrical connection DIN 43650 Pin 1 Pin 2 DIN 72585 Pin 1 Pin 2 MBS4201 MBS4251 MBS4701 MBS4751 PVC cable Black 1 Black 2 ETFE cable Black Blue Cables must be specified for a minimum test voltage of 500 VAC between conductor/earth, conductor/screen and screen/earth. In addition, the total capacity and inductivity of the installation (transmitter + cable) must be taken into consideration. In Zone 0 an intrinsically safe type Ex ia circuit must be used and national regulations for Zone 0 must be complied with. The pressure transmitter must only be used in Zone 0 at atmospheric pressure between 0.8 and 1.1 bar and at ambient temperatures between -20 and 50 C. Maintenance/Adjustment Zero adjustment 0 1 to 0 10 bar -5 20% FS 0 16 to 0 40 bar -5 10% FS 0 60 to 0 600 bar -2.5 2.5 FS Span adjustment -5 5% FS See table Danfoss pressure transmitters type MBS 4201, MBS 4251, MBS 4701 and MBS 4751 are maintenance free. Zero point and span (measurement area) adjustment is possible on MBS 4701 and MBS 4751. Adjustment procedure (see drawing): Loosen screw at top of the DIN 43650 plug. Remove plug. Unscrew the black milled nut from the pressure transmitter and remove the DIN 43650 insert from the transmitter. Install the plug on the DIN 43650 insert and connect the current measuring instrument. Adjust the zero point on the potentiometer below the hole marked ZERO. Adjust the span (measuring range) on the potentiometer below the hole marked SPAN (precise pressure reference must be used). Do not remove the silicone during adjustment. Be sure that the potentiometer is covered with silicone after adjustment 6 520B7682 IC.PI.P20.C7.02 Danfoss DCS (im) 2017.07