ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Similar documents
Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

VITO LT. Global Experience. Locally Applied. A dependable choice.

Enraf SmartRadar Flexline

Installation guide 877 FDI Field Display & Interface

Installation guide 854 XTG Level Gauge

Installation guide 971 SmartRadar LTi

Installation guide 873 SmartRadar Control Unit & Antenna Unit

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

Installation guide 970, 971 and 973 series SmartRadar

Installation guide 970 SmartRadar ATi

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Installation Guide dedicated O-ring for demanding chemicals applications with 854 ATG

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Flow Measurement SITRANS F M

Level Measurement Continuous level measurement Radar transmitters

Micro Motion Fork Viscosity Meters

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Level Measurement Continuous level measurement Radar transmitters

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Rosemount 3101, 3102, and 3105

Coriolis Massflowmeter

Technical Information Proservo NMS5

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

OPTIFLUX 5000 Technical Datasheet

Micro Motion Fork Density Meters

General Specifications

Coriolis Mass Flow Meter Model TM

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Design and applications

ATG SERIES Growco Servo Tank Gauges

Indumax CLS50/CLS50D. Technical Information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

OPTIFLUX 5000 Technical Datasheet

General Specifications

Level gauges Series LT Level indicator, switch and transmitter for liquids

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview

Flow Measurement SITRANS F M

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

DATASHEET F090 - GENERAL PURPOSE INDICATOR

Magnetic Inductive Flowmeter

SMARTLINE LEVEL SLG700

Electro-Magnetic Flowmeters COPA-XE

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

OPTIWAVE 1010 Technical Datasheet

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

TMU. Coriolis Mass Flow Meter. for liquids and gas

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Compact Orifice Flow Meter

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Power supply. Calibration. Surface finishing. Seal. Process connection

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

KFS. Flap-type flow meter. Design and range of application

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

General Specifications

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

Magnetostrictive Level Transmitter

OPTIMASS 1000 Technical Datasheet

Condumax W CLS15 and CLS15D

USM GT400 Ultrasonic Flowmeter

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Coriolis Massflowmeter

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

Analog Universal Module HART for Zone 2 Series 9468/33

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

SITRANS P. Transmitters for level. Introduction 1/42. Application

General Specifications

Smart Displacer Level (Interface) Transmitter DLT100 Series

Full Metal Variable Area Flowmeter and Counter Model BGF

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

Condumax CLS16 and CLS16D

Condumax CLS15 and CLS15D

Radar Level Measurement micropilot FMR 130 for stilling wells

4.00 ULTRASONIC ANALYZER

OPTIFLUX 1000 Technical Datasheet

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

SLAMf Series. Data Sheet. Elastomer Sealed, Digital, Thermal Mass Flow Meters and Controllers. Overview. Product Description.

PiloTREK SZINTTÁVADÓK. Pulse burst radar level transmitters 5 YEARS WARRANTY

EN-2018 MAGNETIC FLOW METERS

Sarasota CM200 Sarasota HME900 Density Converter Electronics

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

SITRANS T measuring instruments for temperature

Series Smart Pressure Transmitter

Transcription:

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Technical Specifications Data Communication Honeywell Bi-phase mark (Pos 2 = E and I) 1200 / 2400 bps > 1,500 V Full galvanic separation via isolating transformers Standard Honeywell fieldbus (Serial, ASCII, GPU protocol) Common mode rejection > 150 db Two wires, twisted pair, Rmax = 200 Ω / line, Cmax = 1 μf; Cable length: 10 km (6 mi) or more *6 RS-232C GPU protocol (Pos 2 = R) Serial ASCII GPU protocol 3-wire RS-232; max cable length: 15 m (50 ft) RS-485 GPU protocol (Pos 2 = S) Serial ASCII GPU protocol 3-wire EIA-485; max cable length: 1200 m (4000 ft) RS-232C Std. Modbus (Pos 2 = V) Std Modbus (refer to protocol manual for details) 3-wire RS-232; max cable length: 15 m (50 ft) RS-485 Std. Modbus (Pos 2 = W) Std Modbus (refer to protocol manual for details) 3-wire EIA-485; max cable length: 1200 m (4000 ft) Foundation Fieldbus (Pos 2 = O) 31.25 kbps > 1500 V FF (refer to protocol manual for details) Refer FF specifications Communication with TSI (Pos 2 = I) 2-wire, intrinsically safe (Rmax = 5Ω (loop) / line, Cmax = 1.27μF) Communication with Portable Honeywell Terminal Infra-red, serial Options Alarm relay outputs 2 x SPDT, galvanically isolated, Vmax = 50 V ac or 30 V dc, Imax = 3 A; Pos 16 = W Density measurement With density PROMS (Pos 15 = D) and density displacer (Pos 22 = E or F) Analog level output 4-20 ma (accuracy ± 0.1% full scale); Pos 4 = V, W, X or Y Temperature input and HART devices Spot RTD; 3 wire; Pos 4 = B, U or Y; VITO probes for average temperature and/or water measurement, HART devices; Pos 4 = C, J, W, X or Y Cable entries Adapters available to fit other sizes cable glands Continued... Notes: HART is a registered trademark of the HART Communications Foundation. Foundation Fieldbus is a trademark of the Fieldbus Foundation. * 1 Under reference conditions * 2 Minimum product density between layers: 100 kg/m3 (6.25 lb/ft3) * 3 (optional) with a density displacer and calibrated for density measurement * 4 With VITO temperature probe or spot (Pt100) * 5 Servo ATG can be used in safety rated loops using alarm relays and/or analog output. Please refer to Safety Manual. * 6 Distances of more than 10 km possible depending on amount of field instruments and cabling topology. * 7 In extreme environments the accuracy could be affected depending on the thermal expansion coefficient of the wetted parts.

Technical Specifications (continued) Measuring Specifications Measuring range Standard 27 m (88 ft) Pos 12 = 2, A, B, C or D Extended 37 m (121 ft) Pos 12 = 3, K, L, M or N; 35 m (115 ft) (with measuring wire up to 150 m (492 ft)) Pos 12 = 9; For longer ranges, please contact factory Measuring accuracy level (27 m / 88 ft): < ± 0.4 mm (± 0.016 ) *1 ; (37 m / 121 ft): < ± 0.7 mm (± 0.028 ) *1 Measuring accuracy interface < ± 2 mm (± 0.08 ) *2 Measuring accuracy servo density < ± 3 kg/m 3 (± 0.19 lb/ft 3 ) Measuring accuracy temperature *1, *4 < ± 0.1 C (± 0.18 F) Sensitivity 0.1 mm (± 0.004 ) *1 Repeatability 0.1 mm (± 0.004 ) *1 Mechanical Flange See Identification Code Pos 8-10 Dimensions See Dimensional Drawing Weight Medium pressure version 16 kg (35 lb) Chemical version 21 kg (46 lb) High pressure version 26 kg (57 lb) Cable entries 4 x ¾ NPT threaded (2* I.S. + 2* non-i.s.) Process Operating pressure M and C versions Up to 6 bar / 0.6 MPa (90 psi); Pos 8 H version Up to 40 bar / 4 MPa (600 psi) (up to 25 bar / 2.5 MPa in acc. to PED); Pos 8 Temperature Max. process temperature +200 C (+392 F), drum housing has to be kept below +65 C (+149 F) *7 Min. process temperature -200 C (-328 F), drum housing has to be kept above -40 C (-40 F) *7 Process Wetted Materials Drum compartment Cast aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3; Pos 8 = M Stainless steel ASTM A351, CF-8M, G-X6 CrNiMo 18 10 (1.4408); Pos 8 = H or C Measuring drum, drum shaft Stainless steel (1.4401) EN10088 AISI 316 Measuring wire See Identification Code ; Pos 12 Magnet cap Stainless steel (1.4401) EN10088 AISI 316 O-rings Drum cover Silicone/FEP; others FPN (Viton ); Special O-ring (Perlas ) available for demanding chemical applications (such as Ammonia), part nr. S0854969 Enclosure Materials Servo comp. and cover All types cast aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3 Finish aluminum parts Conforms to MIL-DTL-5541F Environmental Safety Ambient temperature -40 C to +65 C (-40 F to +149 F) Storage temperature -50 C to +70 C (-58 F to +158 F) Protection class IP66 / IP67 according to EN 60529 (NEMA 4X) Safety Explosion proof II 1/2 G Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb or Ex d [ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb; acc. to ATEX KEMA Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb or Ex d [ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb; acc. to IECEx KEMA II 1/2 G Ex de [ia Ga] IIB T6 Ga/Gb, acc. to Kosha certificate; Class I, Division 1, Group C & D; acc. to FM Class I, Group C & D acc. to CSA certificate Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb or Ex d [ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb; acc. to INMETRO TÜV Consult factory for other approvals and updates Electrical Power supply 110/130/220 V ac (-20% to +10%), 230 V ac (±15%), 65 V ac (-20% to +10%), also suitable for 240 V ac (-20% to +10%) if Pos 14 = K Frequency variations 50/60 Hz (±10%) Power rating 25 VAmax, Imax = 2 A (startup current) Functional Safety Configuration TÜV certified for SIL 2 (single configuration) and SIL 3 (redundant configuration)

Identification Code Pos 1 Type of Gauge U No W&M approval required, with drum calibration report *6, *7 X W&M type approved up to 27 m (88 ft) with OIML R85 calibration report and sealing facilities (only if Pos 22 = A, B or E) *5, *6, *7 P W&M type approved up to 37 m (121 ft) with OIML R85 calibration report and sealing facilities (only if Pos 22 = A, B or E) Pos 2 Data Transmission E Honeyweell Fieldbus Bi-phase Mark (BPM) GPU protocol I Bi-phase Mark (BPM) + I.S. output for tank side indicator 977 R RS-232C GPU protocol (only when Pos 4 = B, C, J, U or Z) S RS-485 GPU protocol (only when Pos 4 = B, C, J, U or Z) V RS-232C standard Modbus (only when Pos 4 = B, C, J, U or Z) W RS-485 standard Modbus (only when Pos 4 = B, C, J, U or Z) O Foundation Fieldbus + BPM Pos 3 Display A 2 lines x 16 characters LCD Pos 4 I/O Options Z No I/O options B Spot temp. convertor Pt-100 (Ex ia) C VITO temp. and/or water sensor J VITO temp. and/or water sensor + HART device(s) U Spot temp. convertor Pt-100 (Ex ia) + HART device(s) V 4-20 ma level output W 4-20 ma level output + VITO temp. and/or water probe X 4-20 ma level output + VITO temp. probe Y 4-20 ma level output + Spot temp. convertor Pt-100 (Ex ia) + VITO temp. and/or water probe + HART device(s) Pos 5, 6, 7 Product Designation 8 5 4 Servo Gauge ATG Pos 8, 9, 10 Pressure, Drum Compartment & Flange M 2 1 2 Class 150 FF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 µm), AL *1 M 2 2 DN50, PN 6, Flanges acc. EN 1092-4, (Ra=3.2-12.5 µm), AL *1 C 1 1 2 Class 150 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 µm), AISI 316 *1 C 1 2 DN50, PN 6, Flanges acc. EN 1092-1, (Ra=3.2-12.5 µm), AISI 316 *1 C 1 3 2 Class 150 FF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 µm), AISI 316 *1 H 5 2 2 Class 300 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 µm), AISI 316 *2 H 5 3 DN50, PN 40, Flanges acc. EN 1092-1, (Ra=3.2-12.5 µm), AISI 316 *2 Pos 11 Safety Approvals A ATEX / IECEx Global C CSA Canada F FM USA I INMETRO Brazil K Kosha Korea Pos 12 Measuring Range & Wire Material 2 27 m (88 ft) AISI 316 A 27 m (88 ft) Hastelloy C22 B 27 m (88 ft) Tantalum C 27 m (88 ft) Invar D 27 m (88 ft) Pt / Ir (80% / 20%) only available in US 3 37 m (121 ft) AISI 316 K 37 m (121 ft) Hastelloy C22 L 37 m (121 ft) Tantalum M 37 m (121 ft) Invar N 37 m (121 ft) Pt / Ir (80% / 20%) only available in US 9 150 m (492 ft) AISI 316 *3 Continued...

Identification Code (continued) Pos 13 Purge Connection No purge connection L 1/4 BSP entry Pos 14 Main Supply A 220 V 50/60 Hz C 110 V 50/60 Hz K 230 V 50/60 Hz R 130 V 50/60 Hz S 65 V 50/60 Hz Pos 15 Density Measurement * No density option D With Density PROMS *4 (Pos 22 = E, F or Z) Pos 16 Hardware Alarms Z No hardware alarms W 2 hardware alarms (SPDT, NO/NC) Pos 17 Separator / Pos 18 Tag Plate Z No tag plate T Tag Plate (Material: CuNi alloy) Pos 19, 20 and 21 Not used Pos 22 Displacer Z None A U815C/223/CT/110 carbon filled Hostaflon PTFE, weight 223 g; diameter 110 mm B U815C/223/CT/90 carbon filled Hostaflon PTFE, weight 223 g; diameter 90 mm C U815C/223/CT/45 carbon filled Hostaflon PTFE, weight 223 g; diameter 45 mm D U815C/223/CT/25 carbon filled Hostaflon PTFE, weight 223 g; diameter 25 mm E U815C/260/S/90 AISI 316; weight 260 g; max pressure 20 barg; diameter 90 mm F U815C/260/S/45 AISI 316; weight 260 g; max pressure 20 barg; diameter 45 mm Pos 23 SIL Compliance S SIL3 /2 Compliance (only if Pos. 4=V,W,X, Y AND/OR Pos. 16 =W) Z No SIL compliance U E A Z 8 5 4 M 2 1 A 2 * A D W / Z A S Typical Identification Code A 8 5 4 / Your Identification Code Notes: Blue positions: Normal delivery Orange positions: For lead time please consult factory or contact your local sales office *1 Maximum operating pressure is 600 kpa *2 Maximum operating pressure is 4 MPa *3 Measuring range is limited to 35 m for ±1 mm accuracy *4 Density displacer required (Pos. 22 = E or F) *5 Contact factory for longer measuring ranges *6 For witnessed verification specify authority. For more information please contact factory. Additional costs not included. *7 Displacer diameter should be selected on basis of (legal) accuracy requirements, operational density range and installation conditions.

From the company that pioneered development of modern tank gauges, Honeywell s 854 Automatic Tank Gauge has become an industry standard all over the world. The gauge is multi-functional: besides liquid level, it integrates density and (free) water interface level measurement with the highest accuracy available in the marketplace. Reliable, versatile and accurate, it meets all international standards, and with its Servo Auto Test feature you can use it in overfill protection loops to prevent spillage. A unique, simple software add-on can be loaded on any servo 854 to add diagnostics and allow it to be used in SIL rated loops. With these diagnostics, the safety proof-test interval can be extended to 5 years. Together with a design featuring minimum moving parts and a modular construction for easy maintenance, it helps you drive down operational costs. Global Experience. Locally Applied. Dimensional Drawing 82 mm (3 1/4 ) 436 mm (17 3/16 ) 352 mm (13 7/8 ) 2 cable entries 3/4 NPT for non i.s. wiring. 2 cable entries 3/4 NPT for i.s. wiring. 233 mm (9 3/16 ) Hoisting eye infra-red coupling B 100 mm (4 ) free space for IR connection 44 mm (1 3/4 ) 200 mm (7 7/8 ) (space needed to remove cover) Position of measuring wire with displacer in top position. Ref. to the instr. code Pos. 9, 10 for the flanges available. M and C versions H versions B 427 mm (1613/16 ) 449 mm (1711/16 ) All technical specifications are subject to change without notice. For More Information To learn more about Honeywell s Enraf solutions, visit www.honeywellenraf.com or contact your Honeywell account manager. Honeywell Process Solutions 1250 West Sam Houston Parkway South Houston, TX 77042 Email: enraf-us@honeywell.com Delftechpark 39 2628 XJ Delft, The Netherlands Email: enraf-nl@honeywell.com 17 Changi Business Park Central 1 Singapore 486073 Email: enraf-sg@honeywell.com www.honeywellprocess.com BR-17-51-ENG June 2018 2018 Honeywell International Inc.