MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Similar documents
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

EVALUATION REPORT GAF Materials Corporation 1361 Alps Road, Building 7-3 Wayne, NJ 07470

NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

ROOFING APPLICATION STANDARD (RAS) No. 130

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

Turada Hardwood Shingles and Shakes Installation instructions

SG-30 A P P L I C A T I O N I N S T R U C T I O N S. Directions For Application

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

FLORIDA PRODUCT APPROVAL 5VCRIMP FLORIDA PRODUCT APPROVAL NO R2. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

Hip & Ridge Shingles Installation Instructions

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: IKO INDUSTRIES LIMITED

DIRECTIONS FOR APPLICATION

A P P L I C A T I O N I N S T R U C T I O N S

DIRECTIONS FOR APPLICATION

CREEK Technical Services, LLC

DIRECTIONS FOR APPLICATION

Timberline and Sovereign Expanded Fastener Placement Area

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER:

Hatteras Shingles. CertainTeed Shingle Applicator s Manual. YOUR OBJECTIVE: To learn the correct procedures for installing Hatteras shingles

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF EVALUATION SUBJECT:

ES Report GAF-Elk Shingle Roof Covering Systems ESR-1475

1.04 QUALITY ASSURANCE

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: GAF 1 CAMPUS DRIVE PARSIPPANY, NEW JERSEY 07054

TECHNICAL BULLETIN NEW ICC ES EVALUATION REPORT

Cambridge English Application Instructions

Capstone Application Instructions

HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

eco-shake INSTALLATION INSTRUCTION

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

CBUCK Engineering. for. Florida Product Approval # FL R1

Application instructions

WOODSTART STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI BUILT STARTER STRIP

RESIDENTIAL ROOFS ADDENDUM NUMBER ONE. August 28, 2017

TEST PROCEDURE FOR DYNAMIC PULL-OFF PERFORMANCE OF ROOFING FASTENER HEADS OR FASTENERS WITH BEARING PLATES

B. Related Sections: The following Sections contain requirements that relate to this Section:

StormMaster Slate General Instructions 1.) GENERAL INSTRUCTIONS 2.) ROOF DECK VENTILATION 3.) ROOF DECK

9Upgrades to Windproof Your Roof

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

3-Tab Shingle Instructions DURA-SEAL 20 DURA-SEAL 25

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY


PROJECT INSTRUCTIONS Roofing

ASPHALT T E C H N O L O G I E S

TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES

SECTION ASPHALT SHINGLES

SECTION ASPHALT SHINGLES

PREMIUM LAMINATED ASPHALT SHINGLES Frederick, MD

Florida Building Code Online

ENDUREED VIVA SERIES Specifications

dd dimension & create distinction with heritage vintage shingles.

Laminated Shingles. Landmark Series and Landmark TL. CertainTeed Shingle Applicator s Manual

ROOFING City of Grand Rapids Building Safety Division

SECTION ASPHALT SHINGLES

Improving the Wind Resistance of Roof Systems: Asphalt Shingle Roofs

Asphalt Shingle Installation at Roof Edges, Intersections and Valleys

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

F-WAVE REVIA SYNTHETIC ROOFING SHINGLES

HERITAGE LAMINATED ASPHALT SHINGLES Tuscaloosa, AL

Timberline Majestic 30 High Definition Shingles Brochure. Updated: 6/09

GlassMaster General Instructions - Ardmore, OK & Hampton, GA <br /> Atlas Roofing

Timberline Natural Shadow Brochure

PRODUCT EVALUATION Effective July 1, 2009 RC-204

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF TILES REPORT HOLDER:

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.

Code Compliance Research Report CCRR-0155

Timberline ArmorShield II Brochure

AIA Specification. Section Slate Shingles PART 1 GENERAL

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES SECTION: METAL ROOF PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ASPHALT SHINGLES REPORT HOLDER: CERTAINTEED CORPORATION EVALUATION SUBJECT:

Polytegola N. Bitumen Roof shingles. Application guide

DECRA Shingle Installation Guidelines

3-Tab Shingle Installation Instructions

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

WOODGATE LAMINATED ASPHALT SHINGLES

Laminate Shingle Installation Instructions

Engineering Services Program

LAMINATED SHINGLES CERTAINTEED SHINGLE APPLICATOR S MANUAL SUPPLEMENT

GAF-Elk Timberline ArmorShield II High Definition Roofing Shingles Product Information. Updated: 3/08

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019

4. Metal roof jacks at penetrations and attachments

tamko.com PREMIUM LAMINATED ASPHALT SHINGLES Beauty that Performs.

OAKRIDGE R SUPER TM Shingles Installation Instructions

RED DIAMOND SHINGLES Roof Installation Introduction:

C e r t a i n T e e d S h i n g l e A p p l i c a t o r s M a n u a l. and Carriage House STEEP. Slope Application. (over 21/12)

L A M I N A T E D A S P H A L T

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Slate Shingle Specifications

Application instructions

STORMMASTER SHAKE GENERAL INSTRUCTIONS

Brava Old World Slate Installation Guide

Paraguard Roof Perimeter Systems ANSI/SPRI ES-1 Test Reports UL. Classified Products

StormMaster Shake GENERAL INSTRUCTIONS For Spanish Instructions Click Here (Para las Instrucciones Españolas Haga Clic Aquí)

OWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1

Transcription:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Seal-A-Ridge Ridge Cap Shingles and GAF Timbertex Premium Ridge Cap Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 14-0603.01 and consists of pages 1 through 9. The submitted documentation was reviewed by Hamley Pacheco, P.E. Page 1 of 9

ROOFING ASSEMBLY APPROVAL Category: Sub-Category: Materials Deck Type: SCOPE Roofing Asphalt Shingles 3-Tab Perforated Wood This approves GAF Seal-A-Ridge Ridge Cap Shingle and GAF Timbertex Premium Ridge Cap Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Specifications GAF Seal-A-Ridge Ridge Cap Shingle Manufacturing Location #1 GAF Timbertex Premium Ridge Cap Shingle Manufacturing Location #2 PRODUCTS MANUFACTURED BY OTHERS Product Loctite PL Roof & Flashing Sealant Product Description 12 x 36 TAS 110 Pre fabricated hip and ridge asphalt shingle with two perforations at 12 o.c. along the 36 length of shingle. 12 x 36 TAS 110 Prefabricated hip and ridge fiberglass reinforced asphalt shingle with perforations at 12 o.c. along the 36 length of the shingle. Product Description Size Manufacturer Adhesive Various Henkel Corp. MANUFACTURING LOCATION 1. Mobile, AL. 2. Mt. Vernon, IN. Page 2 of 9

EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. ASTM D3462 11CA45079 03/21/12 ASTM D3462 12CA30878 02/01/13 TAS 107 11CA45079 03/21/12 TAS 107 12CA38083 02/26/13 Fire Classification TFWZ.R21 09/16/16 PRI Construction Materials TAS 100 GAF-380-02-01 11/06/12 Technologies LLC TAS 100 GAF-381-02-01 11/15/12 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. GAF Seal-A-Ridge and GAF Timbertex Premium Ridge Cap Shingles shall be limited for use as hip and ridge cap shingles only. 3. Shall not be installed on roof mean heights in excess of 33 ft. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. INSTALLATION 1. GAF Seal-A-Ridge Ridge Cap Shingle and GAF Timbertex Premium Ridge Cap Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Nailing for GAF Seal-A-Ridge Ridge Cap Shingle shall be in compliance with Detail A attached. Exposure and course layout for GAF Seal-A-Ridge Ridge Cap Shingle Ridge Cap Shingles shall be in compliance with Detail A. 5. Nailing for GAF Timbertex Premium Ridge Cap Shingles shall be in compliance with Detail B attached. Exposure and course layout for GAF Timbertex Ridge Cap Shingles shall be in compliance with Detail B. 6. A Miami Dade Approved ASTM C 920 Polyurethane Roof Sealant must be used in the application of GAF Seal-A-Ridge Ridge Cap Shingles as specified in Detail A. 7. Henkel Corp. PL Roof & Flashing Sealant must be used in the application of GAF Timbertex Premium Ridge Cap Shingles as specified in Detail B. Page 3 of 9

LABELING Shingles shall be permanently labeled with the manufacturer s name and/or logo, city and state of manufacturing facility, and the following statement: Miami-Dade County Product Control Approved or with the Miami-Dade County Product Control Seal as seen below: BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. Page 4 of 9

DETAIL A GAF Seal-A-Ridge Ridge Cap Shingles Application Instructions: (1) Step One Separate each piece of GAF Seal-A-Ridge Ridge Cap Shingles into three individual ridge cap shingle pieces at perforations (see Figure 1). Figure 1 6 5 /8 Exposure (169 mm approx.) (2) Step Two Begin laying full ridge cap shingle with a 6-2/3 exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind (see Figure 2). Figure 2 Page 5 of 9

(3) Step Three Apply ridge cap using 2 nails per piece 7 to 7-5/8 back from the exposed end and 1 to 2 up from the edge (see Figure 2 for location of nails). Use only corrosion resistant zinc coated steel or aluminum, 10-12 gauge, barbed, deformed or rings shank roofing nails with heads 3/8 (9.5mm) to 7/16 (12mm) in diameter. Nails should be long enough to penetrate at least 3/4 (19mm) into wood decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. Special Application Section: For Cold Weather Application In cold weather, warm GAF Seal-A-Ridge Ridge Cap Shingles before bending. When self-sealing is delayed due to cold weather, apply quarter-sized dabs of an approved asphalt plastic cement (must conform to ASTM D4586 Type I or Type II) between ridge cap pieces and press firmly to insure good contact between pieces. For High-Wind Zones In high wind areas or for maximum wind resistance, apply a ¼ wide bead of a Miami Dade Approved ACTM C 920 Polyurethane Sealant to each ridge cap shingle parallel to the ridge ¾ 1 from the shingle edge. (see Figure 3). Figure 3 Page 6 of 9

DETAIL B GAF Timbertex Premium Ridge Cap Shingles Application Instructions: (1) Step One Separate each piece of GAF Timbertex Premium Ridge Cap Shingles into three individual ridge cap shingle pieces at perforations (see Figure 1). Figure 1 (2) Step Two Prepare the starter course. For this step, take a 12" x 12" (305mm x 305mm) ridge cap piece and cut along the line between exposure and headlap (see Figure 2). Figure 2 Page 7 of 9

(3) Step Three Place the 4" x 12" (102mm x 305mm) starter cap across the ridge starting at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. Note: For cold weather application or for high wind zones see special application section below. (4) Step Four Begin laying full ridge cap shingle pieces 12" x 12" (305mm x 305mm) as shown (see Figure 2). Apply with an 8 exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. (5) Step Five Apply ridge cap using 2 nails per piece 9 back from the exposed end and 1 up from the edge (see Figure 3 for location of nails). Use only zinc coated steel or aluminum, 10-12 gauge, barbed, deformed or smooth shank roofing nails with heads 3/8 (9.5mm) to 7/16 (12mm) in diameter. Nails should be long enough to penetrate at least 3/4 (19mm) into wood decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. Figure 3 Page 8 of 9

Special Application Section: For Cold Weather Application In cold weather, warm GAF Timbertex Premium Ridge Cap Shingles before bending. When self-sealing is delayed due to cold weather, apply quarter-sized dabs of an approved asphalt plastic cement (must conform to ASTM D4586 Type I or Type II) between ridge cap pieces and press firmly to insure good contact between pieces. For High-Wind Zones In high wind areas or for maximum wind resistance, apply a ¼ wide bead of Henkel Corp. Loctite PL Roof & Flashing Sealant to each ridge cap shingle ¾ -1 from the shingle edge, parallel to the ridge (see Figure 4). Note: Excessive application of tab adhesive can cause blistering of ridge cap shingle. Figure 4 END OF THIS ACCEPTANCE Page 9 of 9