INSTALLATION AND OPERATION MANUAL

Similar documents
Level and Pressure. Product Information. Vibrating level switches

Level Measurement With REFLEX RADAR

Operating Instructions

LEVEL Switches RFM-500 RAM-403 RRH-300 RLH-300 RNM-401

Installation instructions Dec. 2002

Level Measurement With REFLEX RADAR

Rod probe With coaxial tube reference probe

SET Installation and Operating Instructions. Level switch for two sensors

KFS. Flap-type flow meter. Design and range of application

OPTIWAVE 7300 C Supplementary instructions

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

MEGGITT MOBREY LTD. MOBREY SQUING Vibrating fork liquid level switch. Product data sheet IP202

Electronic relays. Monitoring. Monitoring

Operating Instructions for Level Switch Tuning Fork Principal. Model: NWS

Safety Instructions Nivotester FTC625, FTC325

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Operating Instruction

Installation guide 971 SmartRadar LTi

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Float Switches with Permanent Magnet For Vertical Installation Model RSM

FOR CLEAN WATER AND SEWAGE WATER HYDROSTATIC LEVEL TRANSMITTERS

Design and applications

Inductive sensor slot-type SI2-K08-AP7

SuperMini SonicLaser

Liquid Level Switches

Capacitance Level Switch

Level and Pressure. Product Information. Conductive level detection

Operating Instructions

Level Limit Switch nivotester FTL 325 P

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

INSTRUCTION MANUAL (ATEX / IECEx)

Digital flow transmitter for continuous flow measurement

Page Type Resolution (mm) min. max. Output

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Ultrasonic level meters ULM 70

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Magnetic Inductive Flow Sensor induq

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Level gauges Series LT Level indicator, switch and transmitter for liquids

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

PRetrans Table of contents

Submersible pressure sensor For oils and fuels Model LF-1

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Absolute encoders - SSI EX approval ATEX EEx d IIC T6 Optical single and multiturn encoders 14 bit ST / 12 bit MT

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Submersible pressure sensor For water and wastewater Model LW-1

INLINE flowmeter for continuous flow measurement

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Soliphant T FTM20, FTM21

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

INLINE flowmeter for continuous flow measurement

Level detection in liquid. Conductive. VEGAKON 61 VEGAKON 66 Probes EL 1, 3, 4, 6, 8. Product Information

Sitron Capacitive Level Sensors

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Liquiphant T FTL20H. Technical Information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Current monitor Type C 551

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Level Lance Model 5100

SATRON VB Pressure Transmitter

Target disk flowmeter for liquids and gases

For clean water and sewage water NIVOPRESS N HYDROSTATIC LEVEL TRANSMITTERS LEVEL TRANSMITTERS

Remote Switching Unit nivotester FTL 320

SBEx-2S BINARY SEPARATOR

FMG90 Series Electromagnetic Flow Meter

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Installation guide 854 XTG Level Gauge

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

INSERTION paddle wheel flowmeter for continuous flow measurement

REFLEX RADAR INDICATOR

Valve Island with Electronic I/O

Operating Instruction

Isolators A3/1. Vibration Transducer Supply Unit Series

ITP14. Universal process indicator. User guide

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

OPTIFLUX 5000 Technical Datasheet

Temperature Input Module for Zone 1 Series 9482/32

INLINE flowmeter for continuous flow measurement

Technical Information Nivector FTC968, FTC968Z

Digital flowmeter for continuous flow measurement

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Level Limit Switch nivotester FTL 370, FTL 372

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

CONDUCTIVE LEVEL PROBE

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Ult r a s o n i c le v e l me t e r s ULM 55

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Installation guide 877 FDI Field Display & Interface

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Ult r a s o n i c le v e l me t e r s ULM 70

... for hydraulic and general applications in hazardous areas

Transcription:

Version 2.2 MS1016 MTF SERIES VIBRATING PROBES FOR LIQUIDS AND HYC-PKK-312 SWITCHING ISOLATOR INSTALLATION AND OPERATION MANUAL Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +00 44 (0)1527 406800 Fax: +00 44 (0)1527 406810 Email: sales@hycontrol.com Web: www.hycontrol.com

INDEX Topic Page 1. PRODUCT OVERVIEW 3 2. TECHNICAL DATA 3 3. ORDER CODE 4 4. RESPONSE TIME 4 5. DIMENSIONS 5 6. TEMPERATURE DIAGRAMS 5 7. INSTALLATION 6 8. WIRING 7 9. ADJUSTMENT AND OPERATION 9 10. EX-APPROVED MODELS AND PFA-COATED 9 PROBES 11. MAINTENANCE & STORAGE 10 12. HYC-PKK-312 SWITCHING ISOLATOR 10 OVERVIEW 13. ISOLATOR DIMENSIONS 10 14. ISOLATOR TECHNICAL DATA 11 15. ISOLATOR WIRING, INSTALLATION AND 11 SET-UP 16. ISOLATOR PROGRAMMING 13 17. APPENDIX 1: ATEX SAFETY GUIDELINES 15 2

1. PRODUCT OVERVIEW Hycontrol's MTF Series Vibrating Probes are ruggedly-designed switch sensors that are used for detection of liquid levels throughout the process industries, and can be customised for many applications, including corrosive, hazardous or hygienic environments. By using the probes as high or low fail safe switch overfilling of tanks and dry run of pumps can be prevented. 2. TECHNICAL DATA General data: SPECIFICATION 3 MTF SERIES Medium pressure 40bar, PP flange: 6 bar see Temperature diagrams Probe length 0.69m - 3m Material of wetted parts DIN 1.4571, PFA coating Temperature Medium -40 C to +130 C see Temperature Classification diagrams and table ranges Ambient --40 C to +70 C Maximum pressure 40 bar (with PP flange 6 bar) See Derating diagrams Probe length 69 to 3000 mm Liquid density 0.7 kg/dm 3 Maximum medium viscosity 10000 mm 2 /s (cst) Response Immersed 0.5 sec time When free 1 sec See Response Time diagram Output mode indicator Bi-colour LED Operation test Output can be changed by test magnet Two-wire DC version (normal and Ex): 2-wire DC TYPE HYCMTF-***E****** HYCMTF-***G******Ex HYCMTF-***J****** HYCMTF-***K******Ex HYCMTF-***F****** HYCMTF-***H******Ex Electric connections Connector 3 m cable (2 x 0.5 mm 2 ) Ingress Protection IP 65 IP 67 IP 68 Output DC current change: When free: 9 ± 1 ma; When immersed: 14 ± 1 ma Consumption < 0,5 W Power supply (U) 15 29 V DC Setting operation mode By switch on the remote switching unit (Low fail-safe, High fail-safe) Electrical protection Class III. Ex protection mark of PFA & 316 versions II 1G Ex ia IIC T6...T4 Ga Ex protection mark of highly polished version II 1G Ex ia IIB T6...T4 Ga Intrinsically safe data U < 29 V, I < 100 ma P<1,4 W, Ceq < 7 nf Leq 0 For temperature classes see temperature classification table (page 8). Two-wire AC version: TYPE 2-wire AC HYCMTF-***A****** HYCMTF-***B****** Electric connections (wire cross section) Connector Integral cable (4 x 0.75 mm 2 ) max length 30 m Mechanical protection IP 65 IP 68 High/low mode setting Connection within connector Wire selectable Output 2-wire AC, for serial connection Supply voltage 20 255 V AC, 50/60 Hz Consumption Depending on load Voltage drop in switched-on state < 10.5 V Electrical protection Class I max. continuous 350 ma AC 13 Current load min. continuous 10 ma / 255 V, 25 ma / 24 V max. impulse 1.5 A / 40 ms Residual current (in switched off state) < 6 ma

Three-wire DC version: TYPE 3-wire DC HYCMTF-***C****** HYCMTF-***L****** HYCMTF-***D****** Electric connections (wire cross section) Connector Integral cable (5 x 0.5 mm 2 ) max length 30m Mechanical protection IP 65 IP 67 IP 68 High/low mode setting Switch selectable Connection within connector Wire selectable Output PNP/NPN transistor switch Field selectable, galvanically isolated PNP/NPN transistor switch Output protection Reverse polarity, overcurrent and short-circuit protection Supply voltage 12 55 V DC Consumption < 0.6 W Voltage drop in switched-on state < 4.5 V Electrical protection Class III max. continuous Imax = 350 ma DC / Umax = 55 V DC Current load min. continuous - max. impulse - Residual current (in switched off state) < 100 µa 3. ORDER CODE 4. RESPONSE TIME Diagram (right) shows response time upon probe getting free in medium viscosity. Response time [S] 35 30 25 20 vertical position 15 10 horizontal position 5 0 0 2000 4000 6000 8000 10000 4 viscosity [cst]

125... 3000 18 ~ 103 5. DIMENSIONS ~110 69 ø40 SW=41 BSP / NPT 1" ~110 125...3000 ø 4 0 S W = 4 1 B S P / N P T 1 " 0.2...3m ~110 18 15 ø 4 0 s = 4 1 s = 5 5 R P H - 1 1 2 B S P 1 1 / 2 " Short version Standard version Sliding sleeve version 40 ~ 110 R_D R_E DN40 DN50 RD 65x1/6 RD 78x1/6 1 1 /2 " / 2 " Flange version Triclamp version Pipe coupling version 6. TEMPERATURE DIAGRAMS T [ C] A 70 55 45 35 IL350 ma I L 100 ma I L 1 ma -40 95 105 115 130 T [ C] M -40 Pressure [p T ] as a function of temperature [T M ] for all versions (except PP flanged version) p [bar] T 6 5 Temperature limits of DC versions, [IL] load current T [ C] A 70 55 1-20 0 0 50 90 T [ C] M -40-40 115 130 T [ C] M Pressure [p T ] as a function of temperature [T M ] for PP flanged version Temperature limits of AC versions, [T A ] ambient temperature [T M ] medium temperature 5

7. INSTALLATION Take care to avoid damaging the unit when handling. MARK For positioning the forks, use the marking on the hexagonal neck as reference. Use a TEFLON (PTFE) tape to seal the thread and position the forks as required. The MTF Series probes can be mounted in many possible positions, as illustrated to the right. They should always be mounted safely away from fill points and any agitators. In applications featuring liquids with low viscosity (when material easily comes off the forks) any of the mountings shown to the right are possible. In high viscosity applications (when the material is likely to stick to the forks) we recommend utilising horizontal (side) mounting. Mounting threaded version Switching point, switch differential: Critical distances (x min = 5mm) Mounting in pipe forks must be parallel to the direction of flow Please note the switching point as well as the switch differential depends slightly on both liquid density and mounting position. (Values are for water at 25 C) 6

8. WIRING WARNING: DO NOT POWER UP THE DEVICE (A) WITHOUT A LOAD CONNECTED IN SERIES WITH THE UNIT AND (B) WITHOUT GROUNDING IT! Two-wire AC version with connector: 2 3 R N 3 R 1 2 N L 1 1 L 1 Low level limit switch High level limit switch Terminal block cover can be rotated in 90 steps to ensure appropriate cable positioning. Two-wire AC version with cable: brown blue black green/yellow R N L 1 brown blue black green/yellow R L 1 N Junction box Low level limit switch Junction box High level limit switch This version is equipped with a 4-wire cable. Only one of the black and brown wires is used, dependent on the operating mode (High or Low). Provide also a terminal block connection for the unused wire. Three-wire DC version with connector: LED 3 2 4 1 "M" - Operation mode M H L LED H= High - level limit switch 3 In case of overload caused by short circuit on 3- L= Low - level limit switch 2 1 wire DC models, transistor will switch on and off, and LED will start to blink. Three-wire DC version with connector in relay application (PNP / NPN): PNP wiring PNP Low level limit switch PNP High level limit switch NPN wiring NPN Low level limit switch NPN High level limit switch Terminal block cover can be rotated in 90 steps to ensure appropriate cable positioning. 7

Three-wire DC version with connector in PLC application with PNP wiring: + Three-wire DC version with cable: 24V DC PLC IN COM brown white black blue R + - brown white black blue R - + Junction box PNP wiring / Low level limit switch (relay applications) Junction box PNP wiring / High level limit switch (relay applications) NPN wiring / Low level limit switch (relay applications) NPN wiring / High level limit switch (relay applications) brown white black blue Junction box + 24VDC - IN COM PLC PNP wiring / Low level limit switch (PLC applications) brown white black blue Junction box + 24VDC - IN COM PLC PNP wiring / High level limit switch (PLC applications) Two-wire DC versions (normal or Ex) with connector: 2 1 3 1 Two-wire DC version (normal or Ex) with cable: brown blue 8

9. ADJUSTMENT AND OPERATION Check connection of the wires and position of the mode of operation switch (if applicable). After connection and power up the tuning fork will be operational. See table below for a guide to the operations of the MTF Series probe (except two-wire DC Version): POWER SUPPLY FORK MODE DISPLAY (LED) OUTPUT HIGH RED OFF I min Utáp ON Immersed LOW HIGH GREEN GREEN ON I N I N U táp U táp NONE Free Free or immersed LOW HIGH or LOW RED NOT LIT OFF I min Utáp U táp Operation of the two-wire DC version): FORK DISPLAY (LED) OUTPUT Immersed RED 14 1 ma Free GREEN 9 1 ma The operation of the switching circuit on an installed device can be easily checked with a test magnet. Moving the test magnet in front of the marking on the cover of the housing of the device will make the circuit switch and the LED will change colour. 10. EX-APPROVED MODELS AND PFA-COATED PROBES For information on Ex-approved models HYCMTF- G Ex, HYCMTF- H Ex and HYCMTF- K Ex please refer to Appendix 1: ATEX Safety Guidelines. PFA-coated probes (HYCMTF- C ): For PFA-coated probes to avoid the danger of electrostatic charge accumulation, the measured medium should be an electrostatic conductor, with an electrical resistivity of 10 4. Speed of the filling and emptying process should be chosen properly according to the measured medium. 9

90 11. MAINTENANCE AND STORAGE The Hycontrol MTF Series switches do not require maintenance on a regular basis. In some instances, however, the vibrating section may need to be cleaned from the deposited material. This must be carried out carefully. Store at an ambient temperature of between -25 C to +60 C. Relative humidity: max. 98%. 12. HYC-PKK-312 SWITCHING ISOLATOR OVERVIEW The HYC-PKK-312- series switching isolators are 4-20mA current-controlled devices which switch at a set current depending on the limit, switching difference or window comparator modes selected by programming. They are suitable for powering Hycontrol s HYCMTF Series two-wire (4-20mA) vibrating level probes. Fault condition monitoring can be switched on or off and the relay can be energised or de-energised when detecting failure as required. Failure may be represented by discontinuity of cable/lower value fault current or short circuit/upper value fault current. The HYC-PKK-312-8Ex unit is pre-set to monitor current levels of the DC powered, two-wire Ex ia HYCMTF probe both in dampened and vibrating modes as well as to control relay output. This isolator must be used in Ex ia applications. Isolator should be mounted on a DIN EN 60715 rail. 13. ISOLATOR DIMENSIONS 1 9,5 10 2 6,5 2 1,5 58 36 10

14. ISOLATOR TECHNICAL DATA HYC-PKK-312-1 2 3 4 8Ex Power / Ex 230vAC 110vAC 24vAC 24vAC/DC 24vDC ATEX EExia IIC Consumption <2.7VA <2.5W <2.5 VA <2.5W Switching level Two values in the range of 1 22mA 10.5mA; 12.5mA IS maximum values - Uₒ<28.4V; Iₒ<80mA; Pₒ<0,6W; Lₒ<4mH; Cₒ<50nF Output load capability Uₒ = 30V IMAX = 70mA UOUT min = 16V Uₒ = 24V IMAX = 80mA UOUT min = 23V Protection class Class II Class III Ambient temperature -25 C +55 C (-13 F +131 F) Nominal input current range 1 22 ma Accuracy of switch / threshold level ± 0.1mA Discontinuity threshold 3.7mA Short circuit threshold 22mA Input impedance 10 Ω Input overload capability Maximum 100mA (permanent) Damping 0,1s; 1s; 2s; 5s selectable Relay output 1 piece SPDT Relay rating 250vAC, 8A, AC1 Relay insulation strength 4000V 50Hz Relay electrical / mechanical lifetime 10⁵ / 2 x 10⁶ switching Electrical connection Maximum 2.5mm² twisted / 4mm² single cable Ingress protection IP20 Mass 0.21kg - 15. ISOLATOR WIRING, INSTALLATION AND SET-UP U t á p 7 8 9 1 0 11 12 1 2 3 4 5 6 Ex Ex After 3 seconds from power up the unit begins to work with the signals as outlined below: WORKING STATUS LED Indication Interpretation Green Relay energised R=1 (SELECT) Red Relay de-energised R=0 Simultaneous red blinking of Memory failure, both led Relay state sustained FAIL No cable fault / No fault current. (STEP) Green No cable monitoring Red Cable fault, or fault current Above: Ex wiring for HYC-PKK-312-8Ex The state of the relay in accordance with the operation mode and depending on the input current will be as shown on the left hand diagram that follows on the next page. Operation with delayed switching is demonstrated on the right hand diagram. 11

I IN I 1 I 2 INPUT CURRENT RELAY STATE in working mode R = 1 t Tripping point current value Limit 1 Limit 2 Switching difference Window RELAY STATE in working mode R = 0 Limit 1 Limit 2 Switching difference Window RELAY ENERGISED < Switching delay Adjusted switching delay CAUTION! If the current value is between the two trip points when the unit is powered up and it is programmed for switching differential, the relay will always remain de-energised irrespective of the relay operation mode (R=1 or R=0) programmed before. Depending on the actual task, programming of the unit s Operation Mode may be needed. The 24v AC/DC Ex unit can be used without any programming for the powering and remote switching function of the Hycontrol HYCMTF two-wire DC vibrating level probe. Please note that the trip point current values (10.5mA and 12.5mA) and the switching differential operating mode cannot be changed. Setting possibilities for 24v AC/DC Ex model: Relay operating mode (Default: R = 1) Monitoring of cable discontinuity (Default: NONE) Monitoring of cable short circuit (Default: NONE) Damping (Default: 0.1 s) Return to default Setting possibilities for all other isolator models: Selection of comparison type (Default: Switching difference) Teaching current value (Default: 10.5 ma and 12.5 ma) Relay operating mode (Default: R=1) Monitoring of cable discontinuity (Default: NONE) Monitoring of cable short circuit (Default: NONE) Damping (Default: 0.1 s) Return to default 12

16. ISOLATOR PROGRAMMING Programming involves setting of operating mode and learning of the input current. Programming / viewing operating mode: Enter programming mode by pressing and holding the A key for 5 seconds until the PROGRAM LED lights up. Then, short-press the A key to sequence through the different STEP LED colour states until the LED colour matches the table column colour for the setting you require. Use short presses of the B key to sequence through the different SELECT LED colour states until you see the desired colour for the table row you require. Refer to the programming / viewing operating mode table below. Repeat this sequence until all settings have been completed and exit programming mode by pressing key A (for approximately 5 seconds) until the PROGRAM LED goes off. Automatic quitting of PROGRAM mode: During programming the unit will continue to operate as previously programmed. On exiting the PROGRAM mode the new program will take effect. If the unit is left in programming mode, it will automatically quit the programming mode after approximately 30 seconds. As the PROGRAM mode has not been properly exited, the incomplete program will be cancelled. PROGRAMMING / VIEWING OPERATING MODE Enter programming mode: press key A (for about 5 seconds) until the PROGRAM LED lights up STEP LED states with corresponding adjustment column, accessed by a short press of key A GREEN GREEN BLINKING RED RED BLINKING OFF Relay operation mode Comparator operation mode R = 1 Limit value 1. R = 0 Limit value 2. Cable short circuit */ monitoring lower current ON: relay should be activated ON: relay should be released Cable discontinuity */ monitoring upper current ON: relay should be activated ON: relay should be released Switching delay SELECT LED states with corresponding adjustment row, accessed by a short press of key B 0.1 s GREEN 1 s GREEN BLINKING -- Switch. difference NO NO 2 s RED -- Window -- -- 5 s RED BLINKING Quit programming mode: press key A (for about 5 seconds) until the PROGRAM LED goes off. Cable monitoring can only be applied with Ex-certified 2-wire units. Relay test: Proper operation of the relay can be tested by pressing key B for about 5 seconds. This will cause the state of the relay and colour of the LED (e.g. from green to red) to change. Releasing the key will allow the relay and LED to return to the previous position. Return to default: Programming will be returned to default if keys A and B are pressed before / during power up. 13

GND Learning current value of trip point: Learning input currents is the saving of the different I IN current values for switching point 1 and switching point 2. The necessary currents can either be provided by the application or if that is not possible by using one of the two circuits shown below: +U OUT I IN GND 1 2 3 4 5 6 +U OUT I IN 1 2 3 4 5 6 R = 50 k A - + I = 1... 2 2 m A A + - CURRENT GENERATOR To enter learning mode, keys A and B should be pressed simultaneously for about 5 seconds until the PROGRAM LED starts blinking. Release either key B or A and the momentary current value will be assigned to switching point 1 or 2. Releasing the other key will complete learning, and the PROGRAM LED will switch off. The second current value can be learned without quitting learning mode, the key already released should be pressed again (for about 5 seconds) and the other key released. LEARNING Position of key A Position of key B STEP LED PROGR. LED SELECT LED Entering learning mode Learning current value for point 1 KEEP PRESSED > 5 s OFF KEEP PRESSED RELEASE OFF Blinking OFF GREEN if SUCCESSFUL RED blinking if FAILED Quitting learning mode RELEASE According to WORKING STATUS OFF According to WORKING STATUS Entering learning mode KEEP PRESSED > 5 s OFF OFF Learning current value for point 2 RELEASE KEEP PRESSED GREEN if SUCCESSFUL RED blinking if FAILED Blinking OFF Quitting learning mode RELEASE According to WORKING STATUS OFF According to WORKING STATUS 14

APPENDIX 1: ATEX SAFETY GUIDELINES ATEX Safety guidelines for the use of the MTF series vibrating probes. General: Vibrating probes HYCMTF- G Ex, HYCMTF- H Ex and HYCMTF- K Ex are designated as ATEX instruments according to ATEX directive 2014/34/EU and should only be powered by intrinsically safe [Ex ia IIC or IIB] certified and approved devices. See Ex markings and maximum surface temperature data for group, category and temperature classification data. Marking of approved instrument according to directive 2014/34/EU: Example of a vibrating probe ATEX Ex ia nameplate Guidance for installation, setup and maintenance Installation, setup and maintenance must be in accordance with the applicable codes of practice and harmonised standards for Ex ia (intrinsically safe) equipment and by qualified technical personnel only. User repairs are not permitted; in case of faults return the unit to Hycontrol. The vibrating probe must only be operated in an intrinsically safe circuit. Conditions of safe operation ATEX II 1G Ex ia IIC T6...T4 Ga and II 1G Ex ia IIB T6...T4 Ga approved vibrating probes should be powered by intrinsically safe [Ex ia IIC or IIB] certified and approved devices (refer to switching isolator / barrier HYC-PKK-312-8Ex information on following page). These units should only be cleaned with a damp cloth. A junction box may be used with the two-wire DC cable Ex version (Std. length = 3m) (HYCMTF- H Ex). The junction box shall meet the appropriate protection requirements. The instrument has built-in overvoltage protection, so the outer grounding of the electrical housing shall be connected to the steel silo wall with a minimal 4mm 2 cross section, shielded copper cable outside the Zone 0 within the distance of 1m from the boundary of the Zone 0. PFA-coated probes For PFA-coated probes (HYCMTF- C ) to avoid the danger of electrostatic charge accumulation, the measured medium should be an electrostatic conductor, with an electrical resistivity of 10 4 Ω. Speed of the filling and emptying process should be chosen properly according to the measured medium. 15

Ex markings TYPE 2-wire DC HYCMTF- A AND HYCMTF- B 2-wire DC HYCMTF- C Ex marking (ATEX) II 1 G Ex ia IIC T6 T4 Ga II 1 G Ex ia IIB T6 T4 Ga Intrinsically safe data (Ex ia IIB and Ex ia IIC) U < 29 V, I < 100 ma, P < 1.4 W, Ci < 7 nf, Li = 0 mh Maximum surface temperature data for hazardous atmospheres: Switching isolator / Barrier HYC-PKK-312-8Ex Example of switching isolator HYC-PKK-312-8Ex ATEX [Ex ia Ga] nameplate Ex markings TYPE Ex marking (ATEX) Intrinsically safe data HYC-PKK-312-8Ex II (1) G [Ex ia Ga] IIC U o < 28.4 V; I o < 80 ma; P o < 0.6 W; L o < 4 mh; C o < 50 nf Wiring HYC-PKK-312-8Ex 2016 Hycontrol Ltd. 16